Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-us
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent Varian Helium Leak Detectors On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Adixen 2021C2 Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Agilent TriScroll Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC TVAC Test Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
The Hastings HFM-210 mass Flowmeter and HFC-212 flow controller are designed to accurately measure and control mass flow over the range of 10 sccm to 30 slm, without corrections or compensations for gas pressure and temperature with an accuracy of better than ±1% FS. Hastings mass flow instruments do not require any periodic maintenance under normal operating conditions with clean gases. No damage will occur from the use of moderate overpressures (~500 psi/3.45MPa) or overflows. Instruments are normally calibrated with the appropriate standard calibration gas (nitrogen) then a correction factor is used to adjust the output for the intended gas. The HFM-210/HFC-212 series is inherently linear (no linearization circuitry is employed). Should recalibration in the field be desired (a calibration standard is required), the customer needs to simply set the zero and span points. There will be no appreciable linearity change of the instrument when the flowing gas is changed.

More information about these The HFM-200/HFC-202 is Teledyne Hastings flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM for its very stable performance with varying ambient conditions. A wide choice of elastomer seals makes this flow controller compatible with most gases. The HFM-200 / HFC-202 meters and controllers have flow ranges from 0-10 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full-scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available. The HFM-200/HFC-202 can support the following variety of applications: Air Sampling, Industrial Furnaces, Gas Blending, R&D Process Flows, Analytical Instrumentation, Catalyst Characterization. The all metal HFM-300/HFC-302 is Teledyne Hastings metal sealed, fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen by OEM for its fast response under a wide range of conditions. The HFM-300 / HFC-302 meters and controllers have flow ranges from 0-5 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full-scale range is specified by the end user. A NIST traceable calibration certificate is standard. Corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available. The HFM-300/HFC-302 can support the following variety of applications: Leak Testing, Flame Spray, Gas Blending, R&D Process Flows.
92.42
Teledyne Hastings VCR 1/4, Low Flow Products , Low Flow Products ,  PN  HFC-212 ,  Option  HFC-212-F03
×

Load

Description

Print Version   
Teledyne Hastings VCR 1/4, This is an Option for Low Flow Products , Low Flow Products ,  PN  HFC-212
This is Option HFC-212-F03 Only, a Component for System HFC-212. Call (505) 872-0037 for Quotation.


These Teledyne Hastings VCR 1/4 are an Option for HFC-212 only, for Low Flow Products   having system part number HFC-212, are new, and come with full Teledyne Hastings warranty. The Hastings HFM-210 mass Flowmeter and HFC-212 flow controller are designed to accurately measure and control mass flow over the range of 10 sccm to 30 slm, without corrections or compensations for gas pressure and temperature with an accuracy of better than ±1% FS. Hastings mass flow instruments do not require any periodic maintenance under normal operating conditions with clean gases. No damage will occur from the use of moderate overpressures (~500 psi/3.45MPa) or overflows. Instruments are normally calibrated with the appropriate standard calibration gas (nitrogen) then a correction factor is used to adjust the output for the intended gas. The HFM-210/HFC-212 series is inherently linear (no linearization circuitry is employed). Should recalibration in the field be desired (a calibration standard is required), the customer needs to simply set the zero and span points. There will be no appreciable linearity change of the instrument when the flowing gas is changed.

More information about these The HFM-200/HFC-202 is Teledyne Hastings flexible, general purpose series of mass flow meters and controllers. Featuring reliability and stability, the 200 Series is chosen by OEM for its very stable performance with varying ambient conditions. A wide choice of elastomer seals makes this flow controller compatible with most gases. The HFM-200 / HFC-202 meters and controllers have flow ranges from 0-10 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full-scale range is specified by the end user. A NIST traceable calibration certificate is standard. Many corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available. The HFM-200/HFC-202 can support the following variety of applications: Air Sampling, Industrial Furnaces, Gas Blending, R&D Process Flows, Analytical Instrumentation, Catalyst Characterization. The all metal HFM-300/HFC-302 is Teledyne Hastings metal sealed, fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen by OEM for its fast response under a wide range of conditions. The HFM-300 / HFC-302 meters and controllers have flow ranges from 0-5 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full-scale range is specified by the end user. A NIST traceable calibration certificate is standard. Corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available. The HFM-300/HFC-302 can support the following variety of applications: Leak Testing, Flame Spray, Gas Blending, R&D Process Flows.Teledyne Hastings VCR 1/4  can be found by downloading the pdf catalog and documents below. Simply open the pdf catalog below, run the pdf search (ctrl F) and search for the Teledyne Hastings part number HFC-212. Please call (505) 872-0037 to receive a quote or for more information.

Price

Product: Teledyne Hastings VCR 1/4, Low Flow Products , Low Flow Products ,  PN  HFC-212

Condition: New
Warranty: Teledyne Hastings Warranty
Part Number: HFC-212
Sale Price: $92.42

Currency US Dollar (USD)

QTY:   

Manuals



AVAILABLE DOWNLOADS:
  Teledyne Hastings HFM-200 HFC-202 Brochure.pdf (1.2 MB)
  Teledyne Hastings HFM-200 HFC-202 Manual.pdf (0.63 MB)
  Teledyne Hastings HFM-200 LFE Brochure.pdf (0.38 MB)
  Teledyne Hastings HFM-201 HFC-203 Brochure.pdf (1.44 MB)
  Teledyne Hastings HFM-201/205 HFC-203/207 Manual.pdf (0.62 MB)
  Teledyne Hastings HFM-205, HFC-207 Brochure.pdf (0.34 MB)
  Teledyne Hastings HFM-300 HFC-302 Brochure.pdf (0.2 MB)
  Teledyne Hastings HFM-300 HFC-302 Manual.pdf (1.07 MB)
  Teledyne Hastings HFM-301 HFC-303 Brochure.pdf (0.29 MB)
  Teledyne Hastings HFM-301/305 HFC-303/307 Manual.pdf (1.2 MB)
  Teledyne Hastings HFM-305 HFC-307 Brochure.pdf (0.22 MB)
  Teledyne Hastings THCD-100 Manual.pdf (2.04 MB)
  Teledyne Hastings THCD-100 Power Supply Brochure.pdf (2.67 MB)
  Teledyne Hastings THCD-400 Brochure.pdf (3.72 MB)
  Teledyne Hastings THCD-400 Power Supply Manual.pdf (1.7 MB)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com