Agilent Varian VacIon 150 StarCell Ion Pump w/ 120 VAC Heaters, 125 l/s Pumping Speed. PN: 9191541
Agilent Varian VacIon 150 StarCell Ion Pump With 120 VAC Heaters Installed, 125 l/s pumping speed, Magnets, and 6 In. CF Intake.
Agilent Varian Part Number 9191541


The Agilent Varian VacIon Plus series of ion pumps are top of the line due to their high-performance in creating Ultra High Vacuum (UHV), their cleanliness, ability to pump different gases, long operating life, ability to read vacuum pressure, and maintenance-free & vibration-free operation. Here we offer the Agilent Varian VacIon Plus 150 StarCell ion pump with 120 VAC heaters installed, and 6 inches conflat intake flange. The VacIon Plus 150 StarCell has an ultimate pressure below 10-11 Torr, maximum baking temperature of up to 350 degrees C, and a 125 l/s pumping speed. A complete technical data and application brochure for the Agilent Varian VacIon Plus 150 StarCell high-vacuum ion pump can be downloaded in PDF format below. This Agilent Varian VacIon Plus 150 StarCell ion pump with magnets and 120 VAC heaters installed has Agilent Varian part number 9191541.

  • Ion Pumps Operation


Vacuum pumps in general operate on the basis of maintaining a lower gas density within themselves than exists in the environment they are pumping. This results in a net gas migration into the pump due to the random motion of the molecules under molecular flow conditions. Once in the pumps, few escape and they are either displaced or captured, depending on the type of pump. Rather than being a displacement pump that actually moves molecules of gas through it to the atmosphere, the ion pump instead captures and stores them. As a result, at some point in time the pump must be reconditioned or replaced. This is generally required only after many years of use.
more info

  • VacIon Plus Overview


Pumping Speed
The most common parameter used to express the capability of a pump to remove molecules from a given volume is pumping speed. It is usually measured in liters per second and expresses the volume of gas (at a given pressure) removed per time unit. In an ion pump the net pumping effect results from the sum of different phenomena:
more info



  • Agilent Varian Quality Manufacturing


Cleanliness
To reach very low pressures (i.e. 10-11 mbar) in any system, both the chamber and pump outgassing must be minimized. If not cleaned properly, the ion pump itself can be a source of gas at UHV. In order to ensure cleanliness VacIon Plus Pumps are factory processed at high temperature in ultraclean vacuum for a thorough outgassing of the body and all internal components. The cleanliness of the ion pump element is even more critical, due to the continuous cathode bombardment. Any gas trapped on the surface or in the bulk of the cathode will eventually be released.
more info




Product: Agilent Varian VacIon 150 StarCell Ion Pump w/ 120 VAC Heaters, 125 l/s Pumping Speed. PN: 9191541
Condition:      New
Warranty:     Varian Warranty
Part Number: P105775
Sale Price: $6,720.95       Regular Price: $8,568.00