Skip to main content
× Home Services Products Catalogs Downloads Tech Support About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
cart
 
Login Icon
login
Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Agilent Varian Helium Leak Detectors On Sale Edwards nXR Multi Stage Roots Pumps On Sale

Keyword       Ideal Vacuum Part Number       Manufacturer Part Number

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC TVAC Test Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
Product Image 1
Product Image 2
Product Image 3

Condition:
  New
Part Number:
  P105358
Warranty:
  Full Manufacturer's Warranty

Available Now:  1   Edwards TAV5 Purge Vent-Valve Kit Normally Open (N/O), 24 VDC, with 3m Long Unterminated Wire for any nEXT Turbo Pump with BSPP (G) 1/8 in. Fitting. PN: B58066010 865.36
Expecting:   1
Anticipated Arrival:  1 on 2024-04-19


Sale: $865.36


×

Load

Print Version

Edwards TAV5 Purge Vent-Valve Kit Normally Open (N/O), 24 VDC, with 3m Long Unterminated Wire for any nEXT Turbo Pump with BSPP (G) 1/8 in. Fitting. PN: B58066010


Edwards TAV5 Purge Vent-Valve Normally Open (N/O), 24 VDC, with 3m Long Unterminated Wire for any nEXT Turbo Pump with BSPP (G) 1/8 in. Fitting.
Edwards Part Number: B58066010

This Edwards TAV5 venting valve can be installed in any nEXT85D, 240D, 300D, 400D, 730D, 930D, or 1230H series turbo pump. This is a normally open (N/O) valve and operates at 24 VDC. This TAV5 solenoid valve comes with a 3 meter long power cable with unterminated (bare wire) end, and has a BSPP (G) 1/8" fitting for connection into the pump's vent port. This valve can be powered by the pump's accessory port (nEXT85D, nEXT730D, nEXT930D, or nEXT1230H) or the connector socket (nEXT240D, nEXT300D, or nEXT400D), a TIC Controller, or a separate 24 VDC power supply. For use with an 85D, 730D, 930D or 1230H nEXT turbo pump, the accessory extension cable is required (part number P1012520), which has an accessory connector on one end and is unterminated on the other. For 240D, 300D, and 400D pump's, the valve's unterminated power wire is connected to the pump's (24 VDC) Phoenix connector socket (the mating phoenix plug is supplied with the pump). This normally open valve can be used as a power failure venting valve. When a power failure occurs, this valve closes and vents the pump and the forevacuum line and thus keeps oil vapor from diffusing back from the forevacuum line.

TAV5 vent valves have an 0.5mm diameter orifice and are suitable for venting small vacuum systems of <5 liters (for larger system volumes, use the TAV6 venting valve with an orifice of 1.0mm, part number P106355). The TAV5 vent valve can replace the manual vent valve that is furnished with the turbo pump, or be fitted into any other suitable port on the vacuum system upstream of the turbomolecular pump. This valve is supplied with a 3 meter long unterminated cable, a sintered bronze inlet-filter, a riffled hose connector for attaching to a dry nitrogen supply, and a DN10NW adapter for optional direct connection to the vacuum system. This TAV5 normally open (NO) solenoid venting valve has Edwards part number B58066010.

This TAV5 normally open venting valve with bare wire cable is suitable for use on these turbo pumps:
  • nEXT85D
  • nEXT240D
  • nEXT300D
  • nEXT400D
  • nEXT730D
  • nEXT930D
  • nEXT1230H



Press ESC to Close


    The TAV5 Vent-Valve Can be Used:
  • In place of the manual vent valve on the EXT or nEXT series turbo pumps
  • Solenoid valve connected to a convenient flange on your vacuum system

OPTION No. OPTIONS / DESCRIPTION OF VENT FUNCTION
0 Vent valve opens fully below 50% full rotational speed for either Stop command or Fail. (This is the factory default setting.)
1 Controlled venting from 100% to 50% full rotational speed; vent valve opens fully below 50% for either Stop command or Fail.
2 Vent valve fully opens immediately Stop command is received; vent valve opens fully below 50% full rotational speed if Fail.
3 Vent valve fully opens immediately Stop command is received; controlled venting from 100% to 50% full rotational speed if Fail then vent valve opens fully below 50%.
4 Vent valve fully opens immediately if Fail; vent valve opens fully below 50% full rotational speed if Stop.
5 Vent valve fully opens immediately if Fail; controlled venting from 100% to 50% full rotational speed if Stop command received then vent valve opens fully below 50%.
6.7 Vent valve fully opens immediately for either Stop command or Fail.



PDF Logo Edwards nEXT Turbomolecular Pumps Entire Range Brochure.pdf

PDF Logo Edwards nEXT 55D 85D Turbo Pumps Instruction Manual.pdf

PDF Logo Edwards nEXT 240D 300D 400D Turbomolecular Pumps Instruction Manual.pdf

PDF Logo Edwards nEXT 240D 300D 400D Turbo Pump Accessories Instruction Manual.pdf

PDF Logo Edwards nEXT 730D 930D 1230H Turbo Pumps Instruction Manual.pdf

PDF Logo Edwards TIC Turbo Instrument Controller Instruction Manual.pdf

PDF Logo Edwards TAG Turbo and Active Gauge Controller Instruction Manual.pdf



You may wish to consider the following products:

Ideal Vacuum Logo Water Mark
CONTACT US
Ideal Vacuum Products, LLC
5910 Midway Park Blvd NE,
Albuquerque, NM 87109-5805

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2