Agilent Varian Helium Leak Detectors On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3
40% OFF

Agilent Varian Turbo-V 1001 Turbomolecular Vacuum Pump, ISO-200K Inlet Flange, Pumping Speed 950 L/S, PN: 9698931

Condition:
  New
Part Number:
  P106002
Warranty:
  Agilent Warranty

Out of Stock   

$28,710.00

On Sale: $17,226.00

Agilent Varian Turbo-V 1001 Turbomolecular Vacuum Pump, ISO-200K Inlet Flange, Pumping Speed 950 L/S, PN: 9698931 17226
Currency: US Dollar (USD)

Description

Agilent Varian Turbo-V 1001 Turbomolecular Vacuum Pump, ISO-200K Inlet Flange, Pumping Speed 950 L/S.
Cooling Kit Required, Agilent Varian Part Number 9698931.

These Agilent Varian Turbo-V 1001 turbomolecular high-vacuum pumps have an ISO-200K inlet flange, an ultimate pressure of 1x10-8 Torr (which is limited by outgassing from the rubber O-ring seal in the intake ISO centering ring), and have an Agilent Varian part number 9698931. The Conflat version, with all metal-sealed conflat intake gasket, are true ultra-high vacuum pumps having an ultimate pressure as low as 1x10-10 Torr when used correctly. The Turbo-V 1001 turbo pumps have a maximize performance at minimum cost and size, with a pumping speed of 950 l/s of nitrogen (N2). We recommend a primary pump size as small as 14 CFM (e.g., IDP-15 dry scroll or DS402 rotary vane vacuum pumps) which can be used to operate the Turbo V 1001 in all its pumping profiles. The Turbo-V 1001 are compound pumps which include the MacroTorr drag stage technology to achieve the high-compression ratios for light gases and maximize the throughput of the pump.

By definition, the Navigator version of the Turbo-V 1001 has the turbo pump controller locally mounted below the turbo pump, the Navigator controller part number is 9698978. However, when the Turbo-V 1001 is powered instead by its rack-mount controller, it is not called a Navigator, it is simply called a Turbo V 1001 turbo pump. The rack-mount controller has Agilent part number X3501-64003. Agilent Varian Turbo-V 1001 Navigators (with below pump mounted controller) are often integrated into many analytical instrumentation applications, including Electron Microscopy (SEM, TEM), Focused Ion-beam Systems (FIB) and Surface Analysis Modern focused-beam systems such as SEM’s, TEM’s and FIB’s utilize columns that project electrons or ions onto microscopic samples for detailed analysis. These Agilent Varian Turbo-V 1001 Navigator turbo pumps are a key component in modern focused-beam systems because they offer fast, oil-free air evacuation of large sample chambers (oil-free operation is a key requirement of many modern analysis applications such as semiconductor manufacturing).

Agilent Varian Turbo-V 1001 Features:
  • High compression ratios for light gases enabling operation at low base pressure
  • Hydrocarbon free for clean vacuum system
  • Remote controller allows operation from 100 m away
  • Installation in any position allows easy integration
  • Maintenance-free bearings for zero operating cost
  • Ready for wireless control via Vacuum Link app for pump operation on the go
  • Radiation and magnetic field-proof design
  • No embedded electronics allows operation in demanding magnetic field and radiation environments
  • Low electromagnetic emission guarantees no interferences with application process
  • Low vibration and noise levels for zero impact on the system

Agilent Varian Turbo-V 1001 Specifications:
  • Ambient Operating Temperature: +5 to +35 °C
  • Ambient Storage Temperature: -20 to +70 °C
  • Base Pressure: 1x10-8 Torr (limited by ISO O-ring seal)
  • Compression Ratio H2: 1 x 10^6
  • FlangeType: Conflat CF 10 Inch
  • Foreline Flange Size: KF 40 NW
  • Maximum Gas Throughput - Ar, Water Cooling: 7.5 mbar L/s; 444 sccm
  • Maximum Gas Throughput - N2, Water Cooling: 10 mbar L/s; 592 sccm
  • Noise Level: 45 dB(A)
  • Nominal Rotation Speed: 38 KRPM
  • Operating Position: Any
  • Pumping Speed - H2: 900 L/s (ISO-200 Inlet flange)
  • Pumping Speed - He: 870 L/s (ISO-200 Inlet flange)
  • Pumping Speed - N2: 950 L/s (ISO-200 Inlet flange)
  • Recommended Forepump Capacity: 15 m³/h
  • Start Up Time: < 4 min
  • Weight: 21.2 kg