× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3
40% OFF

Edwards nEXT240D Turbo Vacuum Pump with Conflat CF 6.0 in. DN100 CF Inlet Flange 240 l/s Pumping Speed Air or Water Cooled. PN: B81200200

Condition:
  New
Part Number:
  P106239
Warranty:
  Edwards Warranty

Available Now   1  

$15,938.17

On Sale: $9,562.91

Edwards nEXT240D Turbo Vacuum Pump with Conflat CF 6.0 in. DN100 CF Inlet Flange 240 l/s Pumping Speed Air or Water Cooled. PN: B81200200 9562.91
Expecting   1
Anticipated Arrival   1 on 2025-02-21
Currency: US Dollar (USD)

Description

Edwards nEXT240D Turbo Vacuum Pump with Conflat CF 6.0" DN100 CF Inlet, 240 l/s Pumping Speed, Air or Water Cooled.
Edwards Part Number: B81200200.

Edwards nEXT240D turbomolecular high vacuum pumps with a DN100 CF, Conflat CF 6.0 inch inlet flange have a pumping speed of 240 liters per second (l/s) and an ultimate pressure of 5 x 10-10 mbar (3.7 x 10-10 Torr). This nEXT240D pump has an ISO KF-25 exhaust foreline flange. Optional inlet screens (coarse or fine) are available. The nEXT240D series turbo pumps require 24 to 48 VDC input power at a maximum of 200 Watts (normal operation is typically less than 160 Watts). A permanently attached DB15 combination power and control cable is standard on the pump. All nEXT240D turbo pumps have a compact onboard controller with RS232 and RS485 interfaces, five status LED's, and a 3-pin Phoenix connector socket to control either an air-cooling fan or solenoid vent valve. All that is needed is a suitable power supply and start/stop logic. For laboratory use we recommend the 200 Watt Edwards Turbo Instrument Controller (TIC) or the Turbo Active Gauge (TAG) which can both act as a power supply and remote controller for the smaller sized nEXT pumps. We also offer a variety of optional accessories, including the TIC and TAG, forced air and water cooling kits, along with solenoid operated vent valves. This nEXT240D turbo pump has Edwards part number B81200200.

Edwards nEXT240D Turbo Pump Specifications:
  • Part Number: B81200200
  • Inlet Flange: DN100 CF, CF 6.0 in.
  • Base Pressure: 5 x 10-10 mbar (3.7 x 10-10 Torr)
  • Operating Speed: 60,000 RPM
  • Operating Position: From horizontal to vertical (inlet up)
  • Pumping Speed: 240 l/s
  • Cooling: Forced Air or Water
  • Exhaust Flange: KF-25
  • Operating Voltage: 24-48 VDC
  • Maximum Power: 200 Watts (typical operation < 160 Watts)
  • Power and Communication: DB15 serial RS232/RS485 interface
  • One accessory port
  • Recommended Roughing Pump: nXDS10i or RV12
The nEXT turbo pumps have a rotor designed to optimize pump performance while maintaining high levels of reliability. The "D" variant of nEXT turbo pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures, and have superior pumping speed and compression across all gas species. In addition to enhanced performance, all nEXT turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decrease downtime. nEXT D turbo pumps benefit from a compact onboard controller which has drive electronics for controlling pump operation and standby speed, and operating solenoid vent valves (TAV5, TAV6) and air-cooling units (via the 24 VDC accessory port). The integral controller has a DB15 interface for RS232 and RS485 serial communications and for supplying pump power. The controller also has five indicator LED's which signal the general status, operation, and service status of the pump. The optional TIC turbo instrument controller, or TAG turbo and active gauge controller can both power and control the pump.

Edwards nEXT pumps with a CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat flanged nEXT240D pumps can be baked up to 120 °C when the turbo is water cooled. Heater bands for the Conflat pumps are sold separately.

For vacuum system integration applications, the nEXT240D pump can be powered by a suitable user supplied 24 to 48 VDC power source. For laboratory applications we recommend the 200 Watt Edwards TIC turbo instrument controller or the TAG turbo & active gauge controller, either of which can both supply power and control the pump. The TIC series of controllers are bench top or rack mountable remote user interface/power sources, which communicate with the Edwards nEXT series pumps through RS232/RS485 and provide full monitoring and control of the turbo pump, and optionally for one or more vacuum gauge instruments. When an Edwards relay box is added, it becomes the control interface between the TIC controller and the mains backing pump, turbo pump flange heater band, and a backing line isolation valve. The TAG turbo and active gauge controller can power nEXT240D turbo pumps and a vacuum gauge, and its large LED display can show pump speed or vacuum pressure.

The pump instruction manual and Edwards nEXT pump product brochures are available in the downloads section.

Typical Turbo Pump Applications include:
  • General clean pumping applications
  • Scanning Electron Microscopes - SEM
  • Beam lines and high energy physics
  • Mass Spectrometry
  • Electron Microscopy
  • Sample Preparation
  • Research and Development
  • High Energy Physics
  • Industrial
  • Semiconductor
  • Coatings
  • Surface Science Instruments

Brochure

Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 2.5586