Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-at
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Agilent Varian Helium Leak Detectors On Sale Adixen 2021C2 Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

MKS Granville Phillips 350 UHV Ultra High Vacuum Hot Cathode Ion Gauge Controller, 1 Line Display. PN: 350501-0-T1
In Stock
18


MKS Granville Phillips 350 Bayard-Alpert UHV Ion Gauge Controller with 1 Line Display, Operates a Series 274 nude Bayard-Alpert type ionization gauge in a compact half-rack design. MKS Granville Phillips Part Number: 350501-0-T1. MKS Granville Phillips UHV 350 Ion Gauge Controller with One Line Digital Display. The 350 Bayard-Alpert UHV Gauge Controller operates a Series 274 nude Bayard-Alpert type ionization gauge in a compact half-rack design. The hot cathode ion gauge measures high vacuum pressure from 10-3 to 10-11 Torr. Cables, ion gauge tubes are available but sold separately. For a complete instruction manual of the MKS Granville Phillips 350 scroll down to DOWNLOADS and download the .pdf. Features of the MKS Granville Phillips 350 Controller Include: 1 line direct digital readout in Torr Electron bombardment degas Front panel filament selection for dual filament gauges Remote Input/Output for filament selection and degas Two channel process control module circuit card (optional) found on this website RS-232 computer interface module circuit card (optional) found on this website PC/RS-232/RS-485 module circuit card (optional) found on this website

Condition: New



Part Number: P104940



Price: €2,377.11




Currency: Euro (Euro)

MKS Granville Phillips 274, Iridium Filament, Bayard-Alpert , 3/4 in. Pyrex Port, Glass Ion Vacuum Gauge. PN: 274002
In Stock
6


MKS Granville Phillips Iridium Filament Glass Ion Gauge Tube, Bayard-Alpert Style, 3/4 inch Pyrex inlet Port, Vacuum Pressure Gauge. MKS Granville Phillips Part Number: 274002 These MKS Granville Phillips 274 Iridium glass ion gauge tubes have a 3/4 inch OD vacuum connection Pyrex Glass port and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104328



Price: €293.41




Currency: Euro (Euro)

MKS Granville Phillips 274, Glass Tubulated Test Gauge with Single Thoria-coated Iridium Filament. PN: 274031
In Stock
1


MKS Granville Phillips 274, Glass Tubulated Test Gauge with Single Thoria-coated Iridium Filament. MKS Granville Phillips Part Number: 274031 This MKS Granville Phillips Iridium glass ion gauge tube is a test gauge vacuum simulator, pumped down and pinched off at 1 X 10-5 or lower. The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104501



Price: €465.23




Currency: Euro (Euro)

MKS Granville Phillips 274, Iridium Filament, Bayard-Alpert , 3/4 in. Kovar Metal, Glass Ion Vacuum Gauge. PN: 274003
In Stock
15


MKS Granville Phillips Iridium Filament Glass Ion Gauge Tube, Bayard-Alpert Style, 3/4 inch Port, Vacuum Pressure Gauge. MKS Granville Phillips Part Number: 274003 These MKS Granville Phillips Iridium glass ion gauge tubes have a 3/4 inch Kovar Metal Inlet OD vacuum connection port and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104329



Price: €320.96




Currency: Euro (Euro)

MKS Granville Phillips 274, Iridium Filament, Bayard-Alpert, 1 in. Kovar Metal, Glass Ion Vacuum Gauge. PN: 274006
In Stock
8


MKS Granville Phillips Iridium Filament Glass Ion Gauge Tube, Bayard-Alpert Style, 1 inch Port, Vacuum Pressure Gauge. MKS Granville Phillips Part Number: 274006 These MKS Granville Phillips Iridium glass ion gauge tubes have a 1 inch Kovar Metal Inlet OD vacuum connection port and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104331



Price: €672.37




Currency: Euro (Euro)

MKS Granville Phillips 274, Single Iridium Filament, Bayard-Alpert , KF25, NW25, 3/4 in, Glass Ion Gauge. PN: 274032
In Stock
2


MKS Granville Phillips 274, Single Thoria Coated, Iridium Filament, Bayard-Alpert , KF25, ISO NW25, 3/4 in, Glass Ion Gauge. MKS Granville Phillips Part Number: 274032 These MKS Granville Phillips Iridium glass ion gauge tubes have a KF25 ISO NW25 Inlet, and a 3/4 inch vacuum connection port with an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104509



Price: €564.11




Currency: Euro (Euro)

MKS Granville Phillips 274, Iridium Filament, Bayard-Alpert , 15 mm OD inlet, Pyrex Glass Ion Gauge. PN: 274036
In Stock
3


MKS Granville Phillips 274, Thoria Coated Iridium Filament, Bayard-Alpert, 15 mm OD inlet, Pyrex Glass Ion Gauge. MKS Granville Phillips Part Number: 274036 These MKS Granville Phillips Iridium glass ion gauge tubes have a 15 mm OD inlet, vacuum connection port with an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104508



Price: €267.07




Currency: Euro (Euro)

MKS Granville Phillips 274, Single Iridium Filament, Bayard-Alpert, 2.75 in. CF, 3/4 in, Glass Ion Gauge. PN: 274007
In Stock
5
Expecting 5
Anticipated Arrival 5 on 2025-01-20


MKS Granville Phillips 274 Single Thoria Coated, Iridium (IR) Filament Glass Ion Gauge Tube, Bayard-Alpert Style, 2.75 inch CF Conflat, 3/4 inch OD Port, Vacuum Pressure Gauge. MKS Granville Phillips Part Number: 274007 These MKS Granville Phillips Iridium glass ion gauge tubes have a 2.75 inch CF Conflat Inlet, and a 3/4 inch vacuum connection port with an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104498



Price: €474.96




Currency: Euro (Euro)

MKS Granville Phillips 274, Single Iridium Filament, Bayard-Alpert , 2.75 in. CF, 1 in, Glass Ion Gauge. PN: 274008
In Stock
3


MKS Granville Phillips 274 Single Thoria Coated, Iridium (IR) Filament Glass Ion Gauge Tube, Bayard-Alpert Style, 2.75 inch CF Conflat, 1 inch OD Port, Vacuum Pressure Gauge. MKS Granville Phillips Part Number: 274008 These MKS Granville Phillips Iridium glass ion gauge tubes have a 2.75 inch CF Conflat Inlet, and a 1 inch vacuum connection port with an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The MKS Granville Phillips thoria coated iridium (IR) filament configuration can be used in any clean application, but is particularly practical in potentially oxygen rich environments. All IR filaments have a thoria coating, which increases electron emission to approximately the same level as tungsten filaments. Iridium filaments, however, can be strongly degraded by metallic or organic contaminants, resulting in poor accuracy (filaments are easily poisoned by oil back-streaming from diffusion or mechanical vacuum pumps). Thoria coated IR is very resistant to oxidation, and can even tolerate brief exposure to atmosphere during operation and will not damage or shorten the filament life. Iridium ion gauge tubes can be typically identified by the single white "hair-pin" shaped filaments and have four external leads at the plug end. This MKS Granville Phillips gauge tube works with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104499



Price: €499.28




Currency: Euro (Euro)

MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 1 in. Pyrex, Glass Ion Pressure Gauge Tube. PN: 274015
In Stock
1


MKS Granville Phillips 274, Dual Tungsten Filaments, Bayard-Alpert, 1 in. Pyrex, Glass Ion Pressure Gauge Tube. MKS Granville Phillips Part Number: 274015 These dual tungsten glass ion gauge tubes have a 1 inch Pyrex port vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy.Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104505



Price: €293.61




Currency: Euro (Euro)

MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 3/4 in. Kovar Metal, Glass Ion Gauge Tube. PN: 274013
In Stock
1
Expecting 5
Anticipated Arrival 5 on 2025-01-20


MKS Granville Phillips 274, Dual Tungsten Filaments, Bayard-Alpert, 3/4 in. Kovar Metal, Glass Ion Pressure Gauge Tube. MKS Granville Phillips Part Number: 274013 These dual tungsten glass ion gauge tubes have a 3/4 inch Kovar Metal port vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy.Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104503



Price: €286.91




Currency: Euro (Euro)

MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 1 in. Kovar Metal, Glass Ion Gauge Tube. PN: 274016
In Stock
2


MKS Granville Phillips 274, Dual Tungsten Filaments, Bayard-Alpert, 1 in. Kovar Metal, Glass Ion Pressure Gauge Tube. MKS Granville Phillips Part Number: 274016 These dual tungsten glass ion gauge tubes have a 1 inch Kovar Metal port vacuum connection and an operating range from 1x10-3 to 2x10-10. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy.Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104504



Price: €304.97




Currency: Euro (Euro)

MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 15 mm OD Pyrex, Glass Ion Pressure Gauge Tube. PN: 274037
In Stock
1


MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 15 mm OD Pyrex, Glass Ion Pressure Gauge Tube. MKS Granville Phillips Part Number: 274037 These dual tungsten glass ion gauge tubes have a 15 mm Pyrex port vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy.Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104510



Price: €250.72




Currency: Euro (Euro)

MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 3/4 in. OD, 2 .75 in. CF Conflat, Ion Gauge. PN: 274017
In Stock
2


MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 3/4 in. OD, 2 .75 in. CF Conflat, Glass Ion Gauge Tube. MKS Granville Phillips Part Number: 274017 These dual tungsten glass ion gauge tubes have a 3/4 inch OD, 2.75 CF Conflat port vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy.Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104506



Price: €408.78




Currency: Euro (Euro)

MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 1 in. OD, 2 .75 in. CF Conflat, Ion Gauge. PN: 274018
In Stock
21


MKS Granville Phillips 274, Dual Tungsten, Bayard-Alpert, 1 in. OD, 2 .75 in. CF Conflat, Glass Ion Gauge Tube. MKS Granville Phillips Part Number: 274018 These dual tungsten glass ion gauge tubes have a 1 inch OD, 2.75 CF Conflat port vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy.Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by MKS Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With:MKS Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104507



Price: €439.29




Currency: Euro (Euro)

MKS Granville Phillips 307 Cable for Tubulated Glass Ion Gauges, Remote Power Supply Mounting 10ft. PN: 307030
In Stock
3


MKS Granville Phillips 307Cable for Tubulated Glass Ion Gauges, Remote Power Supply Mounting, 10 ft (3 meters). MKS Granville Phillips Part Number: 307030 These Granville Phillips 307 ion gauge cables are design for tubulated glass ion gauges. These cables can be used when remote mounting of the 307 power supply. These cables are 10 ft (3 meters) long.

Condition: New



Part Number: P104886



Price: €517.27




Currency: Euro (Euro)

MKS Granville Phillips Ion Gauge Tube Cable Connects 307 Ion Gauge Controller to Glass Ion Gauge Tube, 10ft. Long. PN: 307042
In Stock
31


MKS Granville Phillips Ion Gauge Tube Cable Connects 307 Ion Gauge Controller to Glass Ion Gauge Tube, 10ft. Long. MKS Granville Phillips Part Number: 307042 These MKS Granville Phillips 307 & 330 ion gauge controller cables connect the MKS Granville Phillips 307 or 330 controller to a single glass tube ion guage. These cable are 10ft long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.

Condition: New



Part Number: P102689



Price: €304.76




Currency: Euro (Euro)

MKS Granville Phillips 307 Cable for Tubulated Glass Ion Gauges, Remote Power Supply Mounting 25ft. PN: 307031
In Stock
1


MKS Granville Phillips 307 Cable for Tubulated Glass Ion Gauges, Remote Power Supply Mounting, 25 ft . MKS Granville Phillips Part Number: 307031 These MKS Granville Phillips 307 ion gauge cables are 25 ft. long and are design for tubulated glass ion gauges. These cables can be used when remote mounting of the 307 power supply.

Condition: New



Part Number: P1011071



Price: €518.42




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, KF40 NW40, Single Thoria Coated Iridium, Pin Guard. PN: 274053
In Stock
1


MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge, KF40 NW40 Flange, Pin Guard with Connector Locking Ring, Electron Bombardment Degas or Resistance Heated Degas (controller dependent). MKS Granville Phillips Part Number: 274053 The MKS Graville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Thoria-Coated Iridium Filament, KF40 NW40, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.The Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104518



Price: €964.72




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, KF40 NW40, Dual Thoria Coated Iridium, Pin Guard. PN: 274058
In Stock
9
Expecting 2
Anticipated Arrival 2 on 2025-01-24


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, KF40 NW40, Dual Thoria Coated Iridium, Pin Guard. MKS Granville Phillips Part Number: 274058 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, 1×10-3 to 2×10-11 Torr Pressure Range, Thoria-Coated Iridium Filament, KF40 NW40 Flange, Maximum Bakeout Temperature: 450 °C.The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11 Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104520



Price: €1,118.42




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Single Thoria Coated Iridium, Pin Guard. PN: 274043
In Stock
14


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Single Thoria Coated Iridium, Pin Guard, Bombardment Degas or Resistance Heated Degas (controller dependent) MKS Granville Phillips Part Number: 274043 The MKS Graville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Thoria-Coated Iridium Filament, 2.75 in. CF Flange, Pin Guard with Connector Locking Ring, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C. The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11 Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104516



Price: €971.78




Currency: Euro (Euro)

MKS Granville Phillips 274 Hot Cathode Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Dual Thoria Coated Iridium, Electron Bombardment Degas, Pin Guard. PN: 274023
In Stock
6


MKS Granville Phillips 274 Hot Cathode Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Dual Thoria Coated Iridium, Electron Bombardment Degas, Pin Guard. MKS Granville Phillips Part Number: 274023 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Thoria-Coated Iridium Filament, 2.75 ConFlat Flange, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104512



Price: €1,022.26




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Single Thoria Coated Iridium. PN: 274028
Out of Stock
Expecting 1
Anticipated Arrival 1 on 2025-03-21


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Single Thoria Coated Iridium, Electron Bombardment Degas or Resistance Heated Degas (controller dependent). MKS Granville Phillips Part Number: 274028 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, single Thoria-Coated Iridium Filament, 2.75 CF Flange, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The MKS Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104513



Price: €949.02




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Dual Thoria Coated Iridium, Pin Guard. PN: 274042
In Stock
2


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF, Dual Thoria Coated Iridium, Pin Guard. MKS Granville Phillips Part Number: 274042 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, dual Thoria-Coated Iridium Filament, 2.75 CF Flange, Pin Guard Connector with Locking Ring, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C. The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The MKS Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104515



Price: €1,097.32




Currency: Euro (Euro)

MKS Granville Phillips 274, Replacement for Dual Thoria Coated Iridium Filament, Bayard-Alpert, Nude Gauge. PN: 274025
In Stock
2


MKS Granville Phillips 274 Replacement for Dual Thoria Coated Iridium Filament, Bayard-Alpert Style, Nude Gauges. MKS Granville Phillips Part Number: 274025 This is a Ion Gauge Replacement Dual Thoria Coated Iridium Filament Kit for the MKS Granville Phillips 274 Nude Dual Thoria Coated Iridium Filament Ion Gauges (electron bombardment degas only). This is a Filament Kit ONLY, allen wrench included. Ion Nude Gauges and Controllers sold separately on this website. Fits the Following MKS Granville Phillips 274 Series Dual Thoria Coated Iridium Filament Nude Ion Gauges:• NW40 KF40 flange, pin guard locking strain relief, PN: 274058• 2.75 inch CF Conflat (NW35CF) non-rotatable, PN: 274023• 2.75 inch CF Conflat (NW35CF) non-rotatable, pin guard locking strain relief, PN: 274042

Condition: New



Part Number: P104522



Price: €377.70




Currency: Euro (Euro)

MKS Granville Phillips 274, Replacement for Single Thoria Coated Iridium Filament, Bayard-Alpert, Nude Gauge. PN: 274029
In Stock
2


MKS Granville Phillips 274 Replacement for Single Thoria Coated Iridium Filament, Bayard-Alpert Style, Nude Gauges, MKS Granville Phillips Part Number: 274029 This is a Ion Gauge Replacement Single Thoria Coated Iridium Filament Kit for the MKS Granville Phillips 274 Nude Single Thoria Coated Iridium Filament Ion Gauges (resistive or electron bombardment degas). This is a Filament Kit ONLY, allen wrench included. Ion Nude Gauges and Controllers sold separately on this website. Fits the Following MKS Granville Phillips 274 Series Single Thoria Coated Iridium Filament Nude Ion Gauges:• NW40 KF40 flange, pin guard locking strain relief, PN: 274053• 2.75 inch CF Conflat (NW35CF) non-rotatable, PN: 274028• 2.75 inch CF Conflat (NW35CF) non-rotatable, pin guard locking strain relief, PN: 274043

Condition: New



Part Number: P104523



Price: €322.58




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, KF40 NW40 Flange, Dual Tungsten Filament. PN: 274050
In Stock
1


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, KF40 NW40 Flange, Dual Tungsten Filament. MKS Granville Phillips Part Number: 274050 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Dual Tungsten Filament, KF40 NW40 Flange, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The MKS Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104517



Price: €873.83




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF Flange, Dual Tungsten. PN: 274022
In Stock
9


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF Flange, Dual Tungsten. MKS Granville Phillips Part Number: 274022 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Dual Tungsten Filament, Electron Bombardment Degas, 2.75 CF Flange, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11 Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The MKS Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104511



Price: €858.28




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, KF40 NW40, Dual Tungsten Filament, Pin Guard. PN: 274057
In Stock
1


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, KF40 NW40, Dual Tungsten Filament, Pin Guard. MKS Granville Phillips Part Number: 274057 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Dual Tungsten Filament, KF40 NW40 Flange, Pin Guard Connector with Locking Ring, 1×10-3to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-12 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11 Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The MKS Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104519



Price: €972.74




Currency: Euro (Euro)

MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF Flange, Dual Tungsten, Pin Guard. PN: 274041
In Stock
1


MKS Granville Phillips 274 Nude Bayard-Alpert Ion Gauge, 2.75 in. CF Flange, Dual Tungsten, Pin Guard. MKS Granville Phillips Part Number: 274041 The MKS Granville Phillips 274 Nude Bayard-Alpert Ionization Gauge is a rugged, open gauge with broad-range operating pressure abilities, Dual Tungsten Filament, 2.75 ConFlat Flange with locking ring and pin guard connector, 1×10-3 to 2×10-11 Torr Pressure Range, Maximum Bakeout Temperature: 450 °C.The MKS Granville Phillips 274 Ionization Gauge, with an x-ray limit of 2x10-11 Torr, provides reliable pressure measurement from 1 mTorr down to 2x10-10 Torr, with reduced performance at pressures lower than 2x10-10 Torr. The MKS Granville Phillips 274 utilizes an extremely thin collector which lowers its x-ray limit to 5x10-10 Torr. As a result, it can measure pressure from 1m Torr down to 5x10-11Torr, with reduced performance at pressures lower than 5x10-11 Torr. Properly mounted nude gauges, where the grid structure protrudes into the vacuum chamber, offer the lowest error in terms of the local vacuum pressure being the same as the chamber pressure. The MKS Granville Phillips gauge is easily interfaced with the Varian’s Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool. Typically Works With:MKS Granville Phillips Models: 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments Models: 290, 919, 929Perkin Elmer Model: DGC3 Varian Agilent Models: 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 571 Tube K2471301, XGS-600 Veeco Models: RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002

Condition: New



Part Number: P104514



Price: €1,072.84




Currency: Euro (Euro)

MKS Granville Phillips 274, Replacement Filament for Dual Tungsten Filament, Bayard-Alpert Style, Nude Gauge. PN: 274024
In Stock
1


MKS Granville Phillips 274 Replacement Filament for Dual Tungsten Filament, Bayard-Alpert Style, Nude Gauges, MKS Granville Phillips Part Number: 274024 This is a Ion Gauge Replacement Tungsten Filament Kit for the MKS Granville Phillips 274 Nude dual tungsten Ion Gauges (electron bombardment degas only). This is a Filament Kit ONLY, allen wrench included. Ion Nude Gauges and Controllers sold separately on this website. Fits the Following MKS Granville Phillips 274 Series Dual Tungsten Filament Nude Ion Gauges:• NW40 KF40 flange, PN: 274050• NW40 KF40 flange, pin guard locking strain relief, PN: 274057• 2.75 inch CF Conflat (NW35CF) non-rotatable, PN: 274022• 2.75 inch CF Conflat (NW35CF) non-rotatable, pin guard locking strain relief, PN: 274041

Condition: New



Part Number: P104521



Price: €338.79




Currency: Euro (Euro)

MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 10ft Long. PN: 350004
In Stock
3


MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 10ft Long. MKS Granville Phillips Part Number: 350004 These MKS Granville Phillips 350 ultra-high vacuum (UHV) ion gauge controller cables connect the MKS Granville Phillips 350 controller to a single nude ion guage. These cables are 10ft long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.

Condition: New



Part Number: P102688



Price: €358.49




Currency: Euro (Euro)

MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, Pin Guard, 10ft. PN: 350004-C
Out of Stock
Expecting 1
Anticipated Arrival 1 on 2025-01-20


MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 10ft. Long with Pin Guard/Locking Strain Relief. MKS Granville Phillips Part Number: 350005-C These MKS Granville Phillips 350 ultra-high vacuum (UHV) ion gauge controller cables connect the MKS Granville Phillips 350 controller to a single nude ion guage. This cable has a Pin Guard Locking Relief Connector. These cables are 10 ft long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.

Condition: New



Part Number: P104944



Price: €484.69




Currency: Euro (Euro)

MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, Pin Guard, 25ft. PN: 350005-C
In Stock
1


MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 25ft. Long with Pin Guard/Locking Strain Relief. MKS Granville Phillips Part Number: 350005-C These MKS Granville Phillips 350 ultra-high vacuum (UHV) ion gauge controller cables connect the MKS Granville Phillips 350 controller to a single nude ion guage. This cable has a Pin Guard Locking Relief Connector. These cable are 25 ft. long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.

Condition: New



Part Number: P104945



Price: €748.91




Currency: Euro (Euro)

Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 25 ft Long, 350005
In Stock
1


Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 25 ft Long. MKS Granville Phillips Part Number: 350005 These MKS Granville Phillips 350 ultra-high vacuum (UHV) ion gauge controller cables connect the MKS Granville Phillips 350 controller to a single nude ion guage. These cable are 25 ft long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.

Condition: New



Part Number: P104946



Price: €759.46




Currency: Euro (Euro)

MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 50 ft Long, PN: 350006
Out of Stock


MKS Granville Phillips 350 UHV Ion Gauge Controller Cable, Nude Gauge, 50 ft Long. MKS Granville Phillips Part Number: 350006 These MKS Granville Phillips 350 ultra-high vacuum (UHV) ion gauge controller cables connect the MKS Granville Phillips 350 controller to a single nude ion guage. These cable are 50 ft long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.

Condition: New



Part Number: P104947



Price: €919.42




Currency: Euro (Euro)

MKS Granville Phillips 350 RS-232 Computer Interface module for 350 Vacuum Gauge Controller. PN: 350003
In Stock
3


MKS Granville Phillips 350 RS-232 Computer Interface module board for MKS Granville Phillips 350 Vacuum Gauge Controller. MKS Granville Phillips Part Number: 350003 This is a RS-232 computer interface card module board for field installation in MKS Granville Phillips Series 350 vacuum gauge controllers with 1 line digital display. The RS-232 interface module for the controller allows data output to, and ion gauge control by, a host computer. Output is either by a command-response mechanism or by a talk-only mode which is invoked via a switch on the RS-232 board. A variety of baud rates and byte framing options are available, as well as switches to force the handshake lines to an “always true” condition. See Chapter 5, Page 47 of .pdf manual for instructions on use of the RS-232 Module. This is the RS-232 Computer Interface Card Module ONLY, MKS Granville Phillips 350 Controller, Cables and Accessories sold separately on this website. The MKS Granville Phillips 350 Vacuum Gauge Controller Instruction Manual can be downloaded below at DOWNLOADS:

Condition: New



Part Number: P104941



Price: €778.63




Currency: Euro (Euro)

MKS Granville Phillips 350 RS-232/RS-485 Computer Module for GP 350 Vacuum Gauge Controller. PN: 350027
In Stock
4


MKS Granville Phillips 350 PC RS-232/RS-485 Interface Card Module for MKS Granville Phillips 350 Controller. RS-232 or RS-485 switchable interface with 4 setpoint relays. MKS Granville Phillips Part Number: 350027 This is a PC RS-232 or RS-485 switchable Computer Interface Card Module with 4 setpoint relays for field installation on MKS Granville Phillips Series 350 Controllers with 3 Line Digital Displays. The PC/RS-232/RS-485 interface for the controller allows data output to, and gauge control by, a host computer. Output is by a command-response mechanism. Process control features of this module provide the controller with 4 single-pole, double-throw relays that may be controlled either by 4 digital front panel LED indicator setpoints or by the built-in manual override switches. See Chapter 6, Page 55 of .pdf manual for instructions on use of the RS-232/RS-485 Module. This is the RS-232/RS-485 Computer Interface Card Module ONLY, MKS Granville Phillips 350 Controller, Cables and Accessories sold separately on this website. The MKS Granville Phillips 350 Vacuum Gauge Controller Instruction Manual can be downloaded below at DOWNLOADS:

Condition: New



Part Number: P104942



Price: €1,004.60




Currency: Euro (Euro)

MKS Granville Phillips 350 Two Channel Process Control Card for 350 Vacuum Gauge Controller. PN: 350002
In Stock
3


MKS Granville Phillips 350 Two Channel Process Control Interface Module for MKS Granville Phillips 350 Controller (for field installation in MKS Granville Phillips Series 350 Controllers with 1 Line Digital Display). MKS Granville Phillips Part Number: 350002 This is a two channel process control interface moudule for field installation in the MKS Granville Phillips 350 Controller with 1 line digital display, it has two set point relays for ion gauge. The process control module provides the controller with single-pole, double-throw relays that may be controlled either by 2 digital setpoints or by the built-in manual override switches. See Chapter 4, Page 41 of .pdf manual for instructions on use of the Process Control Module. This is the Process Control Interface Card Module ONLY, MKS Granville Phillips 350 Controller, Cables and Accessories sold separately on this website. The MKS Granville Phillips 350 Vacuum Gauge Controller Instruction Manual can be downloaded below at DOWNLOADS:

Condition: New



Part Number: P104943



Price: €679.67




Currency: Euro (Euro)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com