Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-be
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Adixen 2021C2 Pumps On Sale Edwards nEXT300D TStations On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Agilent Varian VHS-10 Diffusion Pump Std. Cold Cap, 208V, 10 in. ASA, 16 in. OD, 4400W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 208 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 208 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 208 VAC, standard cold cap and has Agilent Varian part number F0426307. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106836



Price: €13,751.07


Regular Price: €15,278.97




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 208V, 10 in. ASA, 16 in. OD, 5100W
Out of Stock
Anticipated Arrival 1 on 2025-02-10


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 208 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. Agilent Varian VHS-10 Diffusion Pump: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 208 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 208 VAC, standard cold cap and has Agilent Varian part number F0426327. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106917



Price: €13,228.62


Regular Price: €15,032.52




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 208V, 10 in. ASA, 16 in. OD, 4400W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 208 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 208 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 208 VAC, extended cold cap and has Agilent Varian part number F0426317. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106906



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 208V, 10 in. ASA, 16 in. OD, 5100W
Out of Stock
Anticipated Arrival 1 on 2025-02-10


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 208 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 208 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 208 VAC, extended cold cap and has Agilent Varian part number F0426337. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106920



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Std. Cold Cap, 240V, 10 in. ASA, 16 in. OD, 4400W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 240 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 240 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 240 VAC, standard cold cap and has Agilent Varian part number F0426308. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106904



Price: €13,228.62


Regular Price: €15,032.52




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 240V, 10 in. ASA, 16 in. OD, 5100W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 240 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 240 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 240 VAC, standard cold cap and has Agilent Varian part number F0426328. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106903



Price: €13,228.62


Regular Price: €15,032.52




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 240V, 10 in. ASA, 16 in. OD, 4400W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 240 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 240 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 240 VAC, extended cold cap and has Agilent Varian part number F0426318. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106907



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 240V, 10 in. ASA, 16 in. OD, 5100W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 240 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 240 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 240 VAC, extended cold cap and has Agilent Varian part number F0426338. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106921



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 380V, 10 in. ASA, 16 in. OD, 4400W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 380 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 380 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 380 VAC, standard cold cap and has Agilent Varian part number F0426326. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106905



Price: €13,215.33


Regular Price: €15,017.42




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 380V, 10 in. ASA, 16 in. OD, 5100W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 380 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 380 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 380 VAC, standard cold cap and has Agilent Varian part number F0426346. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106918



Price: €13,228.62


Regular Price: €15,032.52




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 380V, 10 in. ASA, 16 in. OD, 4400W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 380 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 380 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 380 VAC, extended cold cap and has Agilent Varian part number F0426336. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106908



Price: €13,249.38


Regular Price: €15,056.10




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 380V, 10 in. ASA, 16 in. OD, 5100W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 380 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 380 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 380 VAC, extended cold cap and has Agilent Varian part number F0426356. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106922



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 480V, 10 in. ASA, 16 in. OD, 5100W
Out of Stock
Anticipated Arrival 1 on 2025-01-25


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 480 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 480 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 480 VAC, standard cold cap and has Agilent Varian part number F0426399. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106919



Price: €13,215.33


Regular Price: €15,017.42




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 480V, 10 in. ASA, 16 in. OD, 5100W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 480 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 480 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 480 VAC, extended cold cap and has Agilent Varian part number F0426339. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106923



Price: €13,249.38


Regular Price: €15,056.10




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 480V, 10 in. ASA, 16 in. OD, 4400W.
Out of Stock
Anticipated Arrival 1 on 2025-01-25


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Standard Cold Cap, 480 VAC 2200 Watt (2) Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 480 VAC 3 ph (4400W) with two 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 380 VAC, extended cold cap and has Agilent Varian part number F0426319. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P1012054



Price: €13,215.33


Regular Price: €15,017.42




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 480V, 10 in. ASA, 16 in. OD, 4400W
In Stock
1


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, 10 inch ASA Inlet Flange, 16 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 480 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: 10 Inch ASA Inlet Flange (16 Inch OD Flange, 12 Smooth Bolt Holes, 1" Diameter Holes) 2 inch ASA 6 inch OD Outlet Foreline Flange Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 480 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ASA 10 inch inlet flange, operate on 3-phase 380 VAC, extended cold cap and has Agilent Varian part number F0426319. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106909



Price: €15,828.60


Regular Price: €15,056.10




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 208V, ISO 320K, 14.5 inch OD 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 208 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 208 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 208 VAC, standard cold cap and has Agilent Varian part number L5920307. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106910



Price: €13,228.62


Regular Price: €15,032.52




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 208V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 208 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 208 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 208 VAC, standard cold cap and has Agilent Varian part number L5920327. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106924



Price: €13,296.02


Regular Price: €15,828.60




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Ext. Cold Cap, 208V, ISO 320K, 14.5 inch OD, 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 208 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 208 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 208 VAC, extended cold cap and has Agilent Varian part number L5920317. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106913



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 208V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 208 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 208 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 208 VAC, extended cold cap and has Agilent Varian part number L5920337. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106928



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Std. Cold Cap, 240V, ISO 320K, 14.5 inch OD, 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 240 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 240 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 240 VAC, standard cold cap and has Agilent Varian part number L5920308. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106911



Price: €13,228.62


Regular Price: €15,032.52




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 240V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 240 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 240 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 240 VAC, standard cold cap and has Agilent Varian part number L5920328. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106925



Price: €13,296.02


Regular Price: €15,828.60




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Ext. Cold Cap, 240V, ISO 320K, 14.5 inch OD, 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 240 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 240 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 240 VAC, extended cold cap and has Agilent Varian part number L5920318. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106914



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 240V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 240 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 240 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 240 VAC, extended cold cap and has Agilent Varian part number L5920338. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106929



Price: €13,487.19


Regular Price: €15,867.29




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Std. Cold Cap, 380V, ISO 320K, 14.5 inch OD, 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 380 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 380 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 380 VAC, standard cold cap and has Agilent Varian part number L5920326. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106912



Price: €13,215.33


Regular Price: €15,017.42




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 380V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 380 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 380 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 380 VAC, standard cold cap and has Agilent Varian part number L5920346. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106926



Price: €13,296.02


Regular Price: €15,828.60




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Ext. Cold Cap, 380V, ISO 320K, 14.5 inch OD, 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 380 VAC 2200 Watt Heaters, Agilent. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 380 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 380 VAC, extended cold cap and has Agilent Varian part number L5920336. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106915



Price: €13,249.38


Regular Price: €15,056.10




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 380V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock
Anticipated Arrival 1 on 2025-01-25


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 380 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 380 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 380 VAC, extended cold cap and has Agilent Varian part number L5920356. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106930



Price: €13,262.66


Regular Price: €15,071.21




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Std. Cold Cap, 480V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 480 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 480 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 480 VAC, standard cold cap and has Agilent Varian part number L5920329. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106927



Price: €13,283.34


Regular Price: €15,813.50




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Ext. Cold Cap, 480V, ISO 320K, 14.5 inch OD, 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 480 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 4200 l/s with extended cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 480 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 480 VAC, extended cold cap and has Agilent Varian part number L5920319. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106916



Price: €13,249.38


Regular Price: €15,056.10




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Std. Cold Cap, 480V, ISO 320K, 14.5 inch OD, 4400W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 5300 l/s Standard Cold Cap, (2) 480 VAC 2200 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Standard Cold Cap Recommended Roughing Backing Pump: 30 CFM 5300 l/s Maximum Pumping Speed Air 480 VAC 3 ph (4400W) with (2) 2200 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 480 VAC, standard cold cap and has Agilent Varian part number L5920309. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P102158



Price: €13,215.33


Regular Price: €15,017.42




Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump. Ext. Cold Cap, 480V, ISO 320K, 14.5 in. OD, 5100W
Out of Stock


Agilent Varian VHS-10 Water Cooled Vacuum Diffusion Pump, ISO 320K Inlet Flange, 14.5 inch OD, Maximum Pumping Speed 4200 l/s Extended Cold Cap, (2) 480 VAC 2550 Watt Heaters, Agilent Varian. The Agilent Varian VHS-10 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-10 pump is a rugged, general-purpose unit with an operating range of 1.7 x 10-3 to <5 x 10-9 Torr at 4400W. The Agilent Varian VHS-10 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 5300 l/s with standard cold cap) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 5x10-4 mg/cm2/ min, without the use of any cooled cold cap. This Agilent Varian VHS-10 Diffusion Pump Includes: ISO 320K Inlet Flange (14.5 inch OD Flange, No bolt holes) ISO 63K Outlet Foreline Flange, (3.75 inch OD Flange, No bolt holes) Extended Cold Cap Recommended Roughing Backing Pump: 30 CFM 4200 l/s Maximum Pumping Speed Air 480 VAC 3 ph (5100W) with (2) 2550 Watt Heaters Water Connections 1/8 in. FPT Tee Designed To Be Used With Santovac 5 or IVP 704 Diffusion Pump Oil, 1000cc (1.056 Qt.) full charge Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-10 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 3-phase 208, 240, 380, 480 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian VHS-10 diffusion pumps have ISO 320K inlet flange, operate on 3-phase 480 VAC, extended cold cap and has Agilent Varian part number L5920339. The Agilent Varian VHS-10 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106931



Price: €13,474.36


Regular Price: €15,852.18




Currency: Euro (Euro)

Agilent Varian Bolts to Attach ASA Gate Valves to ASA Diffusion Pumps 3/4-10 1-1/4" Length Hex Bolt - 1 each
In Stock
14


Agilent Varian Bolts to Attach ASA Gate Valves to ASA Diffusion Pumps 3/4-10 1-1/4" Length Hex Bolt - Course Thread, 1 each. These are bolts to attach ASA Gate Valves to ASA Diffusion pumps, ASA sizes 6, 8 and 10 inch. One each, size 3/4-10 1-1/4" Length Hex Bolt - Course Thread.

Condition: New



Part Number: P1011551



Price: €4.66




Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater 208VAC, 2200W, 10.6A, 19.6Ohms, 1 ea., 647310140
In Stock
17


Agilent Varian VHS10 Diffusion Pump Tubular Heater 208VAC, 2200W, 10.6A, 19.6Ohms, Per Heater, PN 647310140 (sold as one each) These Agilent Varian VHS-10 diffusion vacuum pump Tubular-Style replacement heaters are for use with 208 VAC input power. These heaters pull 2200 Watts, 10.6 Amps and have a room temperature resistance of 19.6 Ohms. These heaters are designed to be operated by 208 VAC, two heaters are required for (4400 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310140. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106982



Price: €423.04



Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater 208VAC, 2550W, 12.2A, 17 Ohms, 1 ea., 647310145
Out of Stock
Anticipated Arrival 2 on 2025-01-10


Agilent Varian VHS10 Diffusion Pump Tubular Heater 208VAC, 2550W, 12.2A, 17 Ohms, Per Heater, PN 647310145 (sold as one each) These Agilent Varian VHS-10 diffusion vacuum pump Tubular-Style replacement heaters are for use with 208 VAC input power. These heaters pull 2550 Watts, 12.2 Amps and have a room temperature resistance of 17 Ohms. These heaters are designed to be operated by 208 VAC, two heaters are required for (5100 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310145 and its location is item #10 in graphic diagram and description below. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106941



Price: €423.04



Currency: Euro (Euro)

Agilent Varian VHS10 VHS400 Diffusion Pump Heater 240VAC, 2200W, 9.2A, 26 Ohms, 1 ea., 647310150
In Stock
4


Agilent Varian VHS10 VHS400 Diffusion Pump Tubular Heater 240VAC, 2200W, 9.2A, 26 Ohms, Per Heater, PN 647310150 (sold as one each) These Agilent Varian VHS-10 and VHS-400 diffusion vacuum pump Tubular-Style replacement heaters are for use with 240 VAC input power. These heaters pull 2200 Watts, 9.2 Amps and have a room temperature resistance of 26 Ohms. These heaters are designed to be operated by 240 VAC, two heaters are required for (4400 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310150. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P103147



Price: €423.04



Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater 240VAC, 2550W, 10.6A, 22.6 Ohms, 1 ea., 647310155
In Stock
4


Agilent Varian VHS10 Diffusion Pump Tubular Heater 240VAC, 2550W, 10.6 A, 22.6 Ohms, Per Heater, PN 647310155 (sold as one each) These Agilent Varian VHS-10 diffusion vacuum pump Tubular-Style replacement heaters are for use with 240 VAC input power. These heaters pull 2550 Watts, 10.6 Amps and have a room temperature resistance of 22.6 Ohms. These heaters are designed to be operated by 240 VAC, two heaters are required for (5100 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310155 and its location is item #10 in graphic diagram and description below. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106942



Price: €423.04



Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater 380VAC, 2200W, 5.8A, 66 Ohms, 1 ea., 647310160
In Stock
4


Agilent Varian VHS10 Diffusion Pump Tubular Heater 380VAC, 2200W, 5.8A, 66 Ohms, Per Heater, PN 647310160 (sold as one each) These Agilent Varian VHS-10 diffusion vacuum pump Tubular-Style replacement heaters are for use with 380 VAC input power. These heaters pull 2200 Watts, 5.8 Amps and have a room temperature resistance of 66 Ohms. These heaters are designed to be operated by 380 VAC, two heaters are required for (4400 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310160. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106950



Price: €415.49



Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater 380VAC, 2550W, 6.7A, 56.6 Ohms, 1 ea., 647310165
In Stock
2


Agilent Varian VHS10 Diffusion Pump Tubular Heater 380VAC, 2550W, 6.7A, 56.6 Ohms, Per Heater, PN 647310165 (sold as one each) These Agilent Varian VHS-10 diffusion vacuum pump Tubular-Style replacement heaters are for use with 380 VAC input power. These heaters pull 2550 Watts, 6.7 Amps and have a room temperature resistance of 56.6 Ohms. These heaters are designed to be operated by 380 VAC, two heaters are required for (5100 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310165 and its location is item #10 in graphic diagram and description below. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106944



Price: €423.04



Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater 480VAC, 2200W, 4.6A, 104 Ohms, 1 ea., 647310170
In Stock
16


Agilent Varian VHS10 Diffusion Pump Tubular Heater 480VAC, 2200W, 4.6A, 104 Ohms, Per Heater, PN 647310170 (sold as one each) These Agilent Varian VHS-10 diffusion vacuum pump Tubular-Style replacement heaters are for use with 480 VAC input power. These heaters pull 2200 Watts, 4.6 Amps and have a room temperature resistance of 104 Ohms. These heaters are designed to be operated by 480 VAC, two heaters are required for (4400 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310170. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106951



Price: €415.49



Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater 480VAC, 2550W, 5.3A, 90.4 Ohms, 1 ea., 647310175
In Stock
4


Agilent Varian VHS10 Diffusion Pump Tubular Heater 480VAC, 2550W, 5.3A , 90.4 Ohms, Per Heater, PN 647310175 (sold as one each) These Agilent Varian VHS-10 diffusion vacuum pump Tubular-Style replacement heaters are for use with 480 VAC input power. These heaters pull 2550 Watts, 5.3 Amps and have a room temperature resistance of 90.4 Ohms. These heaters are designed to be operated by 480 VAC, two heaters are required for (5100 Watts of heating power). For heater assembly replacement instructions see page 43 in the instruction manual .pdf below. The Agilent Varian part number for this heater is 647310175 and its location is item #10 in graphic diagram and description below. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106943



Price: €415.49



Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Heater Wire Kit, 10 AWG with Lugs & Molex, PN L8913301
In Stock
1


Agilent Varian VHS-10 Diffusion Pump Heater Wire Kit, 10 AWG Wire, 15 ft. length with Molex and Terminal Lugs. PN L8913301 This is the Agilent Varian VHS-10 Diffusion Pump stranded nickel heater wire kit, 10 AWG wire (15ft.) Terminal Strip Molex, and 10 lugs. See No. 9 below in illustration for heater wire location.

Condition: New



Part Number: P106940



Price: €334.12



Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Heater Wire, 10 AWG, Sold by the foot
In Stock
33


Agilent Varian VHS-10 Diffusion Pump Heater Wire, 10 AWG, Sold by the foot. This is the Agilent Varian VHS-10 Diffusion Pump stranded nickel heater wire, Sold by the foot. (3 - 42 inch lengths required for total replacement per pump). See No. 9 below in illustration for heater wire location.

Condition: New



Part Number: P106939



Price: €29.20



Currency: Euro (Euro)

Agilent Varian Thermal Switch Kit for VHS-10 Diffusion Pump PN L8912301
In Stock
1


Agilent Varian VHS-10, Diffusion Pump Thermal Switch Kit. Agilent Varian PN L8912301 This is a Thermal Switch Kit. Fits the Agilent Varian VHS-10 Diffusion Pump. For location of the baffle retaining ring see item #7 on (diagram exploded view & parts illustration) below. This Thermal Switch Kit includes: Thermal Switch Lug Wire Box Insulator

Condition: New



Part Number: P106937



Price: €269.74



Currency: Euro (Euro)

Agilent Varian Thermal Switch for VHS-4, 6, 10, 250, & 400 Diffusion Pumps PN 642906025
In Stock
8


Agilent Varian Thermal Switch for VHS-4, 6,10, 250, & 400 Diffusion Pumps PN 642906025 This is the Agilent Varian VHS-4, VHS-6, VHS-10, VHS-250, VHS-400 Diffusion Pump replacement Thermal Switch. (Set at 300º F, 148º C). See No. 15 below in illustration for thermal switch location on a VHS-4

Condition: New



Part Number: P106938



Price: €219.56



Currency: Euro (Euro)

Agilent Varian VHS-10 Foreline Baffle Assembly, Diffusion Pump Replacement Parts PN F0435301
Out of Stock


Agilent Varian VHS-10 Foreline Baffle Assembly, Diffusion Pump Replacement Parts Agilent Varian Part Number F0435301 These Agilent Varian VHS-10 diffusion pump replacement foreline baffle assemblies are OEM Agilent Varian replacement parts with part number F0435301. The foreline baffle is located in the roughing line exhaust arm of the diffusion pump. They are designed to help prevent diffusion pump oil from being transported to the roughing pump under high throughput conditions. See the VHS-10 diffusion pump roughing line arm noted by balloon #5 in the illustration below.

Condition: New



Part Number: P106968



Price: €509.38



Currency: Euro (Euro)

Agilent Varian VHS-10 Jet Coupling Diffusion Pump Replacement Part, PN L6367301
Out of Stock


Agilent Varian VHS-10 Jet Coupling Diffusion Pump Replacement Part Agilent Varian Part Number L6367301 These Agilent Varian VHS-10 diffusion pump jet coupling part, it is part of the jet assembly and is a OEM Agilent Varian replacement part for the VHS-10 diffusion vacuum pump. See referenced on Page 42 in instruction manual PDF below. These are original OEM Agilent Varian replacement parts for the VHS-10 diffusion pump having part number L6367301, see item #5 in the diagram exploded view & parts illustration below.

Condition: New



Part Number: P106935



Price: €579.72



Currency: Euro (Euro)

Agilent Varian VHS-10 Jet Assembly Diffusion Pump Replacement Part, PN F0428401
Out of Stock


Agilent Varian VHS-10 Jet Assembly Diffusion Pump Replacement Part Agilent Varian Part Number F0428401 These Agilent Varian VHS-10 diffusion pump jet assemblies are OEM Agilent Varian replacement parts for the VHS-10 diffusion vacuum pumps. This kit includes the complete jet assembly components, see the jet assembly referenced in Page 42 in instruction manual PDF below. These are original OEM Agilent Varian replacement parts for the VHS-10 diffusion pump having part number F0428401, see item #4 in the diagram exploded view & parts illustration below.

Condition: New



Part Number: P106933



Price: €5,600.46



Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Heater Slotted Clamping Plate, 1 ea., R2667301
In Stock
1


Agilent Varian VHS10 Diffusion Pump SLOTTED Clamping Plate, PN R2667301 (sold as one each) These Agilent Varian VHS-10 are SLOTTED retrofit clamping plates. The Agilent Varian part number for this is R2667301 and its location is item #12 in graphic diagram and description below. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106959



Price: €1,604.25



Currency: Euro (Euro)

Agilent Varian VHS-10 Extended Cold Cap Replacement, Diffusion Vacuum Pump Parts, L8917301
In Stock
3


Agilent Varian VHS-10 Extended Cold Cap, Mexican Hat, Diffusion Vacuum Pump Replacement Parts Agilent Varian Part Number L8917301 These Agilent Varian VHS-10 extended cold caps are OEM Agilent Varian replacement parts for the VHS-10 diffusion vacuum pumps. The extended cold cap is sometimes referred to as a Mexican Hat due to its shape. There are two types of cold caps, standard and extended. The type of cold cap used will influence factors, such as, oil backstreaming and final pumping speed of the diffusion pump. For example, the Extended Cold Cap is an option that fits inside the VHS-4, VHS-6, and VHS-10 pumps in place of the standard cold cap. It stops backstreaming as effectively as an optically dense baffle, yet it retains 80% of the pump’s speed. Residual backstreaming is so low that it cannot be measured by the American Vacuum Society’s standard collection method. For removal installation procedures of cold cap see page 41 of instruction manual PDF below. These extended cold caps are OEM original Agilent Varian replacement parts with part number L8917301, see item #2 on (diagram exploded view & parts illustration) below.

Condition: New



Part Number: P107095



Price: €1,503.72



Currency: Euro (Euro)

Agilent Varian VHS-10 Standard Cold Cap Replacement, Diffusion Vacuum Pump Parts, F0429301
In Stock
6


Agilent Varian VHS-10 Diffusion Pump Replacement Standard Cold Cap. Agilent Varian PN F0429301. These Agilent Varian VHS-10 diffusion pump standard cold caps are a replacement part that can be installed at the customer's location. There are two types of cold caps, standard and extended. The type of cold cap used will influence factors, such as, oil backstreaming and final pumping speed of the diffusion pump. For example, the Extended Cold Cap is an option that fits inside the VHS-4, VHS-6, and VHS-10 pumps in place of the standard cold cap. It stops backstreaming as effectively as an optically dense baffle, yet it retains 80% of the pump’s speed. Residual backstreaming is so low that it cannot be measured by the American Vacuum Society’s standard collection method. For location of the cold cap please see item #1 on diagram exploded view & parts illustration shown below. For removal installation procedures of cold cap see page 41 of instruction manual PDF below. These standard cold caps are OEM original Agilent Varian replacement parts with part number F0429301.

Condition: New



Part Number: P107094



Price: €1,465.03



Currency: Euro (Euro)

Agilent Varian VHS-10 Crush Plate for Varian Diffusion Pumps. Agilent K7667001
In Stock
10


Agilent Varian VHS-10 Crush Plate for Varian Diffusion Pumps. Varian Agilent Part Number K7667001 These Agilent Varian VHS-10 diffusion pump crush plates are for Agilent Varian diffusion vacuum pumps. The crush plate is required during heater replacement. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106984



Price: €280.90



Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Heater Clamping Plate A36 Steel, 1 ea.,K4928001
In Stock
1


Agilent Varian VHS-10 Diffusion Pump Heater Clamping Plate A36 Steel, PN K4928001 (sold as one each) These Agilent Varian VHS-10 are A36 steel heater clamping plates. The Agilent Varian part number for this is K4928001 and its location is item #12 in graphic diagram and description below. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106945



Price: €602.77



Currency: Euro (Euro)

Agilent Varian VHS10 Diffusion Pump Heater Cover Plate, 1 ea. L8903301
Out of Stock


Agilent Varian VHS10 Diffusion Pump Heater Cover Plate, PN L8903301 (sold as one each) These Agilent Varian VHS-10 Heater Cover Plate. The Agilent Varian part number for this is L8903301 and its location is item #14 in graphic diagram and description below. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106949



Price: €238.39



Currency: Euro (Euro)

Agilent Varian VHS-10 Diffusion Pump Insulator Blanket , 1 ea., L8914001
In Stock
5


Agilent Varian VHS-10 Diffusion Pump Heater Insulator, Replacement Part, For New Style Diffusion Pumps Agilent Varian Part Number L8914001 These Agilent Varian VHS-10 diffusion pump heater insulator covers are used to insulate the heater from pumps bottom cover. These heater insulators are used in the new-style diffusion pumps. These are OEM Agilent Varian replacement parts with part number L8914001, see item # 13 below in illustration for heater insulator location.

Condition: New



Part Number: P106948



Price: €62.52



Currency: Euro (Euro)

Agilent Varian VHS-10 Splash Baffle Diffusion Pump Replacement Part, PN F0431301
Out of Stock


Agilent Varian VHS-10 Splash Baffle Diffusion Pump Replacement Part Agilent Varian Part Number F0431301 These Agilent Varian VHS-10 diffusion pump splash baffle part, it is part of the jet assembly and is a OEM Agilent Varian replacement part for the VHS-10 diffusion vacuum pump. See referenced on Page 42 in instruction manual PDF below. These are original OEM Agilent Varian replacement parts for the VHS-10 diffusion pump having part number F0431301, see item #6 in the diagram exploded view & parts illustration below.

Condition: New



Part Number: P106934



Price: €925.83



Currency: Euro (Euro)

Agilent Varian VHS-10 O-Ring Kit, Diffusion Vacuum Pump Replacement Parts, PN K0377163
Out of Stock


Agilent Varian VHS-10 O-Ring Kit, Diffusion Vacuum Pump Replacement Parts Agilent Varian Part Number K0377163 This is a replacement O-Ring Kit. Fits the Agilent Varian VHS-10 Diffusion Pump. For location see exploded view below.

Condition: New



Part Number: P108786



Price: €271.76



Currency: Euro (Euro)

Agilent Varian Replacement O-Ring Kit for the VHS-10 Diffusion Pump, ASA 10 in. K0377185
In Stock
1


Agilent Varian Replacement O-Ring Kit for the VHS-10 Diffusion Pump, ASA 10 in. Inlet. PN K0377185 These O-Ring kits fit the Agilent Varian VHS-10, ASA 10 inch inlet, Diffusion Pump. Other diffusion pump accessories are available on this web site. O-Ring Kit Contains: 1 Inlet Flange O-Ring ASA 10 in. Butyl No. 2-385 1 Foreline Outlet Flange O-Ring ASA 2 in. Butyl No. 2-338 10 Viton fill and drain O-rings (old style), Parker No. 2-112 10 Viton fill and drain O-rings (new style, Parker No. 2-113 1 PTFE gasket 1 Sight glass O-ring, Parker No. 2-226

Condition: New



Part Number: P106947



Price: €274.82



Currency: Euro (Euro)

Agilent Varian VHS-10 and VHS-400 Oil Drain Plug, Diffusion Vacuum Pump Replacement Parts. PN: L9173001
In Stock
5


Agilent Varian VHS-10 and VHS-400 Oil Drain Plug, Diffusion Vacuum Pump Replacement Parts. Agilent Varian Part Number: L9173001. This is a replacement Oil Drain Plug. Fits the Agilent Varian VHS-10 and VHS-400 Diffusion Pump. For location of the oil drain plug see figure #7 (diagram exploded view & parts illustration) below.

Condition: New



Part Number: P1013552



Price: €145.16




Currency: Euro (Euro)

Agilent Varian VHS-10 Oil Sight Glass Kit, Diffusion Vacuum Pump Replacement Parts, PN L8908301
Out of Stock
Anticipated Arrival 2 on 2025-01-25


Agilent Varian VHS-10 Oil Sight Glass Kit, Diffusion Vacuum Pump Replacement Parts Agilent Varian Part Number L8908301 This is a replacement Sight Glass Kit. Fits the Agilent Varian VHS-10 Diffusion Pump. For location of the sight glass kit see item #3 on (diagram exploded view & parts illustration) below.

Condition: New



Part Number: P106932



Price: €165.92



Currency: Euro (Euro)

Agilent Varian Replacement Inlet O-Ring for VHS-10, 10 in. ASA Inlet Flange, 1 ea., F0430001
Out of Stock


Agilent Varian VHS10 Replacement Inlet O-Ring for VHS-10, 10 in. ASA Inlet Flange PN F0430001 (sold as one each) These Agilent Varian ASA 10 in. O-Rings are replacements for the Inlet O-Ring in the VHS-10 (ASA 10 in.) Diffusion Pump O-Ring Kit PN K0377185. Other diffusion pump accessories are available on this web site.

Condition: New



Part Number: P106946



Price: €90.68



Currency: Euro (Euro)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com