× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

MKS Granville Phillips 390 Micro-Ion ATM Modular Vacuum Pressure Transducer, NO SET POINTS, WITH DISPLAY, NW 25KF, 390411-0-YE-T
In Stock
1
Expecting 3
Anticipated Arrival 1 on 2025-01-31


Granville Phillips 390 Series Micro ATM Module Gauge, NW 25 KF, Digital Display, NO SETPOINTS with Dual Yttria-coated Iridium ion gauge filaments, Torr Readout. Pressure Measurement of 1x10-9 Torr. PN: 390411-0-YE-T This 390411 Total Pressure Micro-Ion Module works with the Granville Phillips Vacuum Quality Monitor System (VQM) The Granville-Phillips Micro-Ion ATM module combines proven Micro-Ion ionization gauge technology with a miniature Conductron heat loss sensor and two Piezo resistive sensors to provide accurate, continuous pressure measurement from high vacuum to atmosphere. Using its diaphragm sensors, this product is capable of providing accurate absolute pressure up to atmosphere along with precision indication of vacuum chamber differential pressure from ambient. The unique sensor design eliminates thermal effects that can influence the performance of the heat loss sensor at higher pressures. This small module combines all four sensors and control electronics in a compact modular design, reducing the number of gauges required on a chamber and minimizing the required space. The full range pressure measurement is output as a single analog signal or available through optional serial RS-485 or DeviceNet digital interfaces. The RS-485 and DeviceNet versions have up to three optional setpoint relays can be configured for process control, with the ability to assign the relays at any pressure across the vacuum pressure range or to a specific differential pressure value. BENEFITS INCLUDE: •Continuous pressure measurement from 1 x 10-9 high vacuum to atmosphere. • Precision differential pressure measurement at atmosphere. • Eliminates need for discrete atmospheric switches. • Eliminates need for three separate sensors. • Dual ionization gauge filaments increase equipment uptime. • Automation of ionization gauge activation and deactivation. • Optional setpoint relays for process control. • Field replaceable gauge assembly. • Analog, RS-485 or DeviceNet output available. • Optional graphics LCD display. Modular vacuum gauges are an ideal solution for applications that do not need front panel displays and controls. These compact, convenient, reliable, cost-saving modules have the control electronics mounted directly on the gauge. The all-metal package provides a rugged enclosure and a high level of immunity to electrical noise. Mini-Convectron Modules use the latest electronics technology to operate the Granville-Phillips®Convectron®Gauge. The Convectron Gauge has become an industry standard. It is a unique variation of thermal conductivity gauges where pressure measurement is based on the rate of heat loss from a sensor wire. Unlike traditional thermocouple and Pirani gauges that use only conductive heat loss, Convectron Gauges take advantage of heat loss due to convection at higher pressures. This extends the range of accurate, repeatable measurement to atmosphere.

Condition: New



Part Number: P109802



Price: Fr. 1,982.64



Currency: Swiss Franc (CHF)

MKS Granville Phillips 390 Micro-Ion ATM Modular Vacuum Pressure Transducer, NO SET POINTS, NO DISPLAY, CF 2.75, 390510-0-YG-T
In Stock
2


Granville Phillips 390 Series Micro ATM Module Gauge, CF 2.75, NO Display, NO SETPOINTS with Dual Yttria-coated Iridium ion gauge filaments, Torr Readout. With RS-485 Analog. Pressure Measurement of 1x10-9 Torr. PN: 390510-0-YG-T This 390411 Total Pressure Micro-Ion Module works with the Granville Phillips Vacuum Quality Monitor System (VQM). The Granville-Phillips Micro-Ion ATM module combines proven Micro-Ion ionization gauge technology with a miniature Conductron heat loss sensor and two Piezo resistive sensors to provide accurate, continuous pressure measurement from high vacuum to atmosphere. Using its diaphragm sensors, this product is capable of providing accurate absolute pressure up to atmosphere along with precision indication of vacuum chamber differential pressure from ambient. The unique sensor design eliminates thermal effects that can influence the performance of the heat loss sensor at higher pressures. This small module combines all four sensors and control electronics in a compact modular design, reducing the number of gauges required on a chamber and minimizing the required space. The full range pressure measurement is output as a single analog signal or available through optional serial RS-485 or DeviceNet digital interfaces. The RS-485 and DeviceNet versions have up to three optional setpoint relays can be configured for process control, with the ability to assign the relays at any pressure across the vacuum pressure range or to a specific differential pressure value. BENEFITS INCLUDE: •Continuous pressure measurement from 1 x 10-9 high vacuum to atmosphere. • Precision differential pressure measurement at atmosphere. • Eliminates need for discrete atmospheric switches. • Eliminates need for three separate sensors. • Dual ionization gauge filaments increase equipment uptime. • Automation of ionization gauge activation and deactivation. • Optional setpoint relays for process control. • Field replaceable gauge assembly. • Analog, RS-485 or DeviceNet output available. • Optional graphics LCD display. Modular vacuum gauges are an ideal solution for applications that do not need front panel displays and controls. These compact, convenient, reliable, cost-saving modules have the control electronics mounted directly on the gauge. The all-metal package provides a rugged enclosure and a high level of immunity to electrical noise. Mini-Convectron Modules use the latest electronics technology to operate the Granville-Phillips®Convectron®Gauge. The Convectron Gauge has become an industry standard. It is a unique variation of thermal conductivity gauges where pressure measurement is based on the rate of heat loss from a sensor wire. Unlike traditional thermocouple and Pirani gauges that use only conductive heat loss, Convectron Gauges take advantage of heat loss due to convection at higher pressures. This extends the range of accurate, repeatable measurement to atmosphere.

Condition: New



Part Number: P1011326



Price: Fr. 2,119.77



Currency: Swiss Franc (CHF)

MKS Granville Phillips 390 Micro-Ion Gauge ATM Module for GP 830, 835 VQM. 2 SETPOINTS, WITH DISPLAY, CF 2.75 in., 390802-2-YG-T
In Stock
4


MKS Granville Phillips 390 Series Micro ATM Module Gauge, 2.75 in. 2 Setpoints CF, Digital Display, Dual Yttria-coated Iridium ion gauge filaments, Pressure Measurement of 1x10-9 Torr. For Vacuum Quality Monitor (VQM) 830 or 835. PN: 390802-2-YG-T This 390802 Total Pressure Micro-Ion Module works with the MKS Granville Phillips Vacuum Quality Monitor System (VQM) 830 or 835 Power Mass Spectrometer Gauge. VQM. The MKS Granville-Phillips Micro-Ion ATM module combines proven Micro-Ion ionization gauge technology with a miniature Conductron heat loss sensor and two Piezo resistive sensors to provide accurate, continuous pressure measurement from high vacuum to atmosphere. Using its diaphragm sensors, this product is capable of providing accurate absolute pressure up to atmosphere along with precision indication of vacuum chamber differential pressure from ambient. The unique sensor design eliminates thermal effects that can influence the performance of the heat loss sensor at higher pressures. This small module combines all four sensors and control electronics in a compact modular design, reducing the number of gauges required on a chamber and minimizing the required space. The full range pressure measurement is output as a single analog signal or available through optional serial RS-485 or DeviceNet digital interfaces. The RS-485 and DeviceNet versions have up to three optional setpoint relays can be configured for process control, with the ability to assign the relays at any pressure across the vacuum pressure range or to a specific differential pressure value. BENEFITS INCLUDE: •Continuous pressure measurement from 1 x 10-9 high vacuum to atmosphere. • Precision differential pressure measurement at atmosphere. • Eliminates need for discrete atmospheric switches. • Eliminates need for three separate sensors. • Dual ionization gauge filaments increase equipment uptime. • Automation of ionization gauge activation and deactivation. • Optional setpoint relays for process control. • Field replaceable gauge assembly. • Analog, RS-485 or DeviceNet output available. • Optional graphics LCD display. Modular vacuum gauges are an ideal solution for applications that do not need front panel displays and controls. These compact, convenient, reliable, cost-saving modules have the control electronics mounted directly on the gauge. The all-metal package provides a rugged enclosure and a high level of immunity to electrical noise. Mini-Convectron Modules use the latest electronics technology to operate the MKS Granville-Phillips®Convectron®Gauge. The Convectron Gauge has become an industry standard. It is a unique variation of thermal conductivity gauges where pressure measurement is based on the rate of heat loss from a sensor wire. Unlike traditional thermocouple and Pirani gauges that use only conductive heat loss, Convectron Gauges take advantage of heat loss due to convection at higher pressures. This extends the range of accurate, repeatable measurement to atmosphere.

Condition: New



Part Number: P107278



Price: Fr. 3,441.58




Currency: Swiss Franc (CHF)

Granville Phillips MKS 24VDC Power Supply for 385 and 390 Micro-Ion Gauge ATM Modules Analog RS-485
In Stock
2
Expecting 1
Anticipated Arrival 1 on 2025-04-04


Granville Phillips MKS 24VDC Transformer Power Supply for 385 and 390 Micro-Ion Gauge ATM Modules - Analog RS-485 PN: 390200-1 This is a Granville Phillips MKS 24VDC Power Supply Transformer for GP 385 or GP 390 Micro-Ion ATM Modules Analog RS-485.

Condition: New



Part Number: P1010071



Price: Fr. 550.71



Currency: Swiss Franc (CHF)

MKS Granville Phillips Connection Kit for GP 830, 835 VQM System. Conflat CF 2.75 in. Flange
Out of Stock
Anticipated Arrival 458 on 2025-02-28


MKS Granville Phillips Kit, VQM System Connection 6 Bolts, Washers, Plate Nuts, Copper Gasket for 275CF This hardware/bolt kit is for connecting an MKS Granville Phillips VQM 830/835MS Gauge to a 2.75 in. CF flange and includes 6 flange bolts and washers, 3 plate nuts, and 1 copper gasket; PN 801274-1.

Condition: New



Part Number: P108233



Price: Fr. 42.66




Currency: Swiss Franc (CHF)