Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-eg
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent TriScroll Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Pfeiffer ASM340 Leak Detectors On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Adixen 2021C2 Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

MKS HPS 317 Convection Enhanced Pirani Sensor KF16 NW16 103170010SH
In Stock
4


MKS HPS® Series 317 Convection Enhanced Pirani Sensor KF16 NW16 (PN 103170010SH) (Compatible with MKS 947 Convection Enhanced Pirani Gauge Controller) The MKS HPS® 317 Convection-Enhanced Pirani Sensor provides dependable and stable pressure measurement at a very low cost. Since the only materials exposed to vacuum are stainless steel, nickel, glass, and platinum, the sensor is compatible with a wide array of process gases and is especially suitable for UHV applications. The platinum filament effectively eliminates any reading variance throughout a convection sensor’s higher measuring range. More accurate than a thermocouple sensor, the 317 Sensor measures over a wider pressure range and responds more rapidly to process pressure changes. The upper measuring limit of a convection-enhanced Pirani sensor is increased over that of a traditional Pirani sensor from 100 Torr to 1,000 Torr. This higher limit is useful when monitoring the pumpdown of a vacuum system from atmosphere to a base pressure. The sensor compensates for any changes in room temperature ranging from 10° to 50°C. Like all thermal conductivity sensors, the 317 sensor is innately gas-type sensitive. This feature makes it a simple solution for locating medium to fine leaks in vacuum systems. It complements a mass spectrometer leak detector, which is more efficient in finding smaller leaks. The sensor, which is shielded against RF noise, meets CE mark requirements and can be baked to 100°C. This 317 Sensor include standard vacuum connections such as this KF16 NW16 flange. The cable for this sensor is not included but available in standard 10 feet lengths. The 317 Sensor can be used with the Series 947 Convection Pirani Vacuum Gauge Controller also sold on this website. A complete specification brochure and operations manual are available download in PDF format below.

Condition: New



Part Number: P103327



Price: E£22,993.97




Currency: Egyptian Pound (EGP)

MKS HPS 317 Convection Enhanced Pirani Sensor KF25 NW25 103170027SH
In Stock
3


MKS HPS® Series 317 Convection Enhanced Pirani Sensor KF25 NW25 (PN 103170027SH) (Compatible with MKS 947 Convection Enhanced Pirani Gauge Controller) The MKS HPS® 317 Convection-Enhanced Pirani Sensor provides dependable and stable pressure measurement at a very low cost. Since the only materials exposed to vacuum are stainless steel, nickel, glass, and platinum, the sensor is compatible with a wide array of process gases and is especially suitable for UHV applications. The platinum filament effectively eliminates any reading variance throughout a convection sensor’s higher measuring range. More accurate than a thermocouple sensor, the 317 Sensor measures over a wider pressure range and responds more rapidly to process pressure changes. The upper measuring limit of a convection-enhanced Pirani sensor is increased over that of a traditional Pirani sensor from 100 Torr to 1,000 Torr. This higher limit is useful when monitoring the pumpdown of a vacuum system from atmosphere to a base pressure. The sensor compensates for any changes in room temperature ranging from 10° to 50°C. Like all thermal conductivity sensors, the 317 sensor is innately gas-type sensitive. This feature makes it a simple solution for locating medium to fine leaks in vacuum systems. It complements a mass spectrometer leak detector, which is more efficient in finding smaller leaks. The sensor, which is shielded against RF noise, meets CE mark requirements and can be baked to 100°C. This 317 Sensor include standard vacuum connections such as this KF25 NW25 flange. The cable for this sensor is not included but available in standard 10 feet lengths. The 317 Sensor can be used with the Series 947 Convection Pirani Vacuum Gauge Controller also sold on this website. A complete specification brochure and operations manual are available for download in PDF format below.

Condition: New



Part Number: P103328



Price: E£24,240.78




Currency: Egyptian Pound (EGP)

MKS HPS 317 Convection Enhanced Pirani Vacuum Sensor Conflat CF 1.33 inch. PN: 103170013SH
In Stock
3


MKS HPS® Series 317 Convection Enhanced Pirani Vacuum Sensor features a 0.001 to 1000 Torr, Conflat CF 1.33 in. MKS Part Number: 103170013SH. The MKS HPS® 317 Convection-Enhanced Pirani Sensor provides dependable and stable pressure measurement at a very low cost, Compatible with MKS 947 Convection Enhanced Pirani Gauge Controller. Since the only materials exposed to vacuum are stainless steel, nickel, glass, and platinum, the sensor is compatible with a wide array of process gases and is especially suitable for UHV applications. The platinum filament effectively eliminates any reading variance throughout a convection sensor’s higher measuring range. More accurate than a thermocouple sensor, the 317 Sensor measures over a wider pressure range and responds more rapidly to process pressure changes. The upper measuring limit of a convection-enhanced Pirani sensor is increased over that of a traditional Pirani sensor from 0.001 to 1,000 Torr. This higher limit is useful when monitoring the pumpdown of a vacuum system from atmosphere to a base pressure. The sensor compensates for any changes in room temperature ranging from 10° to 50°C. Like all thermal conductivity sensors, the 317 sensor is innately gas-type sensitive. This feature makes it a simple solution for locating medium to fine leaks in vacuum systems. It complements a mass spectrometer leak detector, which is more efficient in finding smaller leaks. The sensor, which is shielded against RF noise, meets CE mark requirements and can be baked to 100°C. This 317 Sensor include standard vacuum connections such as this CF 1.33 inch Mini-CF flange fitting. The cable for this sensor is not included but available in standard 10 feet lengths. The 317 Sensor can be used with the Series 947 Convection Pirani Vacuum Gauge Controller also sold on this website. A complete specification brochure and operations manual are available for download in PDF format below.

Condition: New



Part Number: P1012864



Price: E£26,268.33




Currency: Egyptian Pound (EGP)

MKS HPS 317 Convection Enhanced Pirani Vacuum Sensor Conflat CF 2.75 inch. PN: 103170014SH
In Stock
3


MKS HPS® Series 317 Convection Enhanced Pirani Vacuum Sensor features a 0.001 to 1000 Torr, Conflat CF 2.75 in. MKS Part Number: 103170014SH. The MKS HPS® 317 Convection-Enhanced Pirani Sensor provides dependable and stable pressure measurement at a very low cost, Compatible with MKS 947 Convection Enhanced Pirani Gauge Controller. Since the only materials exposed to vacuum are stainless steel, nickel, glass, and platinum, the sensor is compatible with a wide array of process gases and is especially suitable for UHV applications. The platinum filament effectively eliminates any reading variance throughout a convection sensor’s higher measuring range. More accurate than a thermocouple sensor, the 317 Sensor measures over a wider pressure range and responds more rapidly to process pressure changes. The upper measuring limit of a convection-enhanced Pirani sensor is increased over that of a traditional Pirani sensor from 0.001 to 1,000 Torr. This higher limit is useful when monitoring the pumpdown of a vacuum system from atmosphere to a base pressure. The sensor compensates for any changes in room temperature ranging from 10° to 50°C. Like all thermal conductivity sensors, the 317 sensor is innately gas-type sensitive. This feature makes it a simple solution for locating medium to fine leaks in vacuum systems. It complements a mass spectrometer leak detector, which is more efficient in finding smaller leaks. The sensor, which is shielded against RF noise, meets CE mark requirements and can be baked to 100°C. This 317 Sensor include standard vacuum connections such as this CF 2.75 Conflat flange. The cable for this sensor is not included but available in standard 10 feet lengths. The 317 Sensor can be used with the Series 947 Convection Pirani Vacuum Gauge Controller also sold on this website. A complete specification brochure and operations manual are available for download in PDF format below.

Condition: New



Part Number: P108198



Price: E£26,268.33




Currency: Egyptian Pound (EGP)

MKS Vacuum Gauge Cable Connecting 937B or 946 Controllers to HPS 317 Sensor, 10 ft. (3m). PN: 103170006SH
In Stock
3


MKS Vacuum Gauge Cable for 345 or 317 Connecting to 937B and 946 Controllers, 10 Ft. (3m) Long. MKS Part Number: 103170006SH. The MKS vacuum gauge signal cable connects 345 or 317 vacuum gauge sensors to 945, 947, 937B, and 946 controllers. It connects to the back of the MKS controllers and to the side of the MKS 345 or 317 Pirani Sensor. This is the Cable ONLY. The Series 947 Convection-Enhanced Pirani Controller offers many standard features and is easy to use. An analog output signal proportional to pressure is standard and is accessible from the rear of the controller, there is where this cable is connected. Processes are controlled with two independent relay set points that are standard on this single-channel controller. The relays can be set to trip anywhere within the controller’s set point range. All of the operating controls are conveniently accessible from the front panel of the controller, including the power on-off switch. Adjust set points from the front panel while viewing the large, easy-to-read display. Set point activation is shown with red LED indicators. Set points can be checked at any time with no break in process control.

Condition: New



Part Number: P103329



Price: E£9,169.08




Currency: Egyptian Pound (EGP)

MKS Vacuum Gauge Cable Connecting 937B or 946 Controllers to HPS 317 Sensor, 25 ft. (7.5m). PN: 103170007SH
In Stock
3


MKS Vacuum Gauge Cable for 345 or 317 Connecting to 945, 947, 937B or 946 Controllers, 25 ft. (7.5m) Long. MKS Part Number: 103170007SH. The MKS vacuum gauge signal cable connects 345 or 317 vacuum gauge sensors to 945, 947, 937B, or 946 controllers. It connects to the back of the MKS controllers and to the side of the MKS 345 or 317 Pirani Sensor. This is the Cable ONLY. The Series 947 Convection-Enhanced Pirani Controller offers many standard features and is easy to use. An analog output signal proportional to pressure is standard and is accessible from the rear of the controller, there is where this cable is connected. Processes are controlled with two independent relay set points that are standard on this single-channel controller. The relays can be set to trip anywhere within the controller’s set point range. All of the operating controls are conveniently accessible from the front panel of the controller, including the power on-off switch. Adjust set points from the front panel while viewing the large, easy-to-read display. Set point activation is shown with red LED indicators. Set points can be checked at any time with no break in process control.

Condition: New



Part Number: P1012845



Price: E£12,225.44




Currency: Egyptian Pound (EGP)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com