Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-nl
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Agilent Varian Helium Leak Detectors On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Teledyne-Hastings DV-23 1/8" NPT, Thermocouple Vacuum Gauge Tube, 0.001 to 5 Torr Range
Out of Stock


Teledyne-Hastings DV-23, 1/8 Male NPT, Thermocouple Vacuum Gauge Tube, 0.001 to 5 Torr Range This Teledyne-Hastings DV-23 1/8 NPT thermocouple (TC) vacuum gauge tube measures pressure between 0.001 and 5 Torr (1 to 5000 mTorr) and calibrated for clean, dry air or nitrogen. DV-23 series gauge tubes are used with the now obsolete Teledyne-Hastings V-3 and CVH-23 units (not included). These inexpensive sensors are used as ‘rough’ indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-23 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-23 gauge tubes are rated for a maximum temperature of 100° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. Thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-23 series gauge tubes are available with several vacuum port configurations: DV-23, Standard Tube with 1/8 inch Male NPT DV-23-KF-16, Standard Tube with ISO KF-16 DV-23-KF-25, Standard Tube with ISO KF-25 DV-23-4-VCR, Standard Tube with Female ¼ inch VCR

Condition: New



Part Number: P1011145



Price: €236.90



Currency: Euro (Euro)

Teledyne Hastings HPM-4/6 Octal Socket for All Thermocouple Vacuum Gauge Tubes, DV-4, DV-5, DV-6, DV-23, PN: 28-07-049
In Stock
9


Teledyne Hastings HPM-4/6 Octal Socket for All Thermocouple Vacuum Gauge Tubes, DV-4, DV-5, DV-6, DV-23 PN: 28-07-049This is a replacement octal socket for all Teledyne-Hastings thermocouple vacuum gauge tubes including all DV-4, DV-5, DV-6 and DV-23 gauges. Use to replace a broken part, or to make your own gauge cable. We stock most Teledyne Hastings thermoucouple gauge tubes and gauge controllers.

Condition: New



Part Number: P1011448



Price: €31.49



Currency: Euro (Euro)

Teledyne Hastings Replacement AC power cord with Lugs for Analog Enclosed Gauge Controllers DV-4, DV-5, DV-6, DV-23, PN: 65-757
In Stock
4


Teledyne Hastings Replacement AC power cord with Lugs for Analog Enclosed Gauge Controllers PN: 65-757 This is a replacement AC power cord for all enclosed analog Teledyne-Hastings thermocouple vacuum gauge controllers. We stock most Teledyne Hastings thermoucouple gauge tubes, reference tubes, and gauge controllers.

Condition: New



Part Number: P1011542



Price: €67.15



Currency: Euro (Euro)

Teledyne Hastings Octal Socket Cable 8ft. for All Thermocouple Vacuum Gauge Tubes, DV-4, DV-5, DV-6, DV-23
Out of Stock
Expecting 1
Anticipated Arrival 1 on 2024-12-17


Teledyne Hastings Octal Socket Cable 8ft. for All Thermocouple Vacuum Gauge Tubes, DV-4, DV-5, DV-6, DV-23 PN: LUG-8-OFVThis is a replacement octal socket cable 8 ft. for all Teledyne-Hastings thermocouple vacuum gauge tubes including all DV-4, DV-5, DV-6 and DV-23 gauges. We stock most Teledyne Hastings thermoucouple gauge tubes and gauge controllers.

Condition: New



Part Number: P1011903



Price: €122.04



Currency: Euro (Euro)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com