Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-ph
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Pfeiffer ASM340 Leak Detectors On Sale Edwards nEXT300D TStations On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Matheson Model 3510ANL Single Stage High Purity SS Regulator, No Inlet, Delivery Pressure Range 0-125 PSIG, SEQ3510ANLNI
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANLNI, No Inlet, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109532



Price: ₱230,515.93



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-320, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL320
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-320, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109474



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-326, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL326
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-326, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109475



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-330, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL330
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-330, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109476



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-346, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL346
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-346, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109477



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-350, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL350
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-350, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109478



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-510, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL510
Out of Stock
Anticipated Arrival 1 on 2025-01-15


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-510, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109208



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-540, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL540
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-540, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109479



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-580, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL580
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-580, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109480



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-590, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL590
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-590, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109481



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-660, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL660
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-660, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109482



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3510ANL Single Stage High Purity SS Regulator, CGA-705, Delivery Pressure Range 0-125 PSIG, SEQ3510ANL705
In Stock
1


Matheson Model 3510ANL Single Stage High Purity SS Regulator SEQ3510ANL, CGA-705, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-705 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3510ANL regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3510ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109483



Price: ₱229,008.00



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, No Inlet, Delivery Pressure Range 0-15 PSIG, SEQ3511ANLNI
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANLNI, No Inlet, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) >Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109533



Price: ₱229,305.12



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-320, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL320
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-320, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) >Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109452



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-326, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL326
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511A, CGA-326, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109453



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-330, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL330
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-330, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109454



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-346, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL346
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-346, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109455



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-350, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL350
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-350, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109456



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-510, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL510
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-510, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109457



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-540, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL540
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-540, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109458



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-580, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL580
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-580, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109459



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-590, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL590
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-590, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109460



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-660, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL660
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-660, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109461



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3511ANL Single Stage High Purity SS Regulator, CGA-705, Delivery Pressure Range 0-15 PSIG, SEQ3511ANL705
In Stock
1


Matheson Model 3511ANL Single Stage High Purity SS Regulator SEQ3511ANL, CGA-705, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-705 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3511ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3511ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109462



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, No Inlet, Delivery Pressure Range 0-50 PSIG, SEQ3513ANLNI
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANLNI, No Inlet, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109534



Price: ₱229,305.12



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-320, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL320
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-320, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109463



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-326, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL326
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-326, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109464



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-330, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL330
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-330, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109465



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-346, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL346
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-346, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109466



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-350, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL350
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-350, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109467



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-510, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL510
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-510, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109468



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-540, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL540
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-540, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109469



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-580, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL580
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-580, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109470



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-590, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL590
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-590, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109471



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-660, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL660
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-660, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109472



Price: ₱231,356.80



Currency: Philippine Peso (PHP)

Matheson Model 3513ANL Single Stage High Purity SS Regulator, CGA-705, Delivery Pressure Range 0-50 PSIG, SEQ3513ANL705
In Stock
1


Matheson Model 3513ANL Single Stage High Purity SS Regulator SEQ3513ANL, CGA-705, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-705 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3513ANL regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3513ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109473



Price: ₱132,120.00



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, No Inlet, Delivery Pressure Range 0-250 PSIG, SEQ3516ANLNI
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANLNI, No Inlet, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109535



Price: ₱219,538.81



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-320, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL320
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-320, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109484



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-326, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL326
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-326, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109485



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-330, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL330
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-330, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109486



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-346, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL346
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-346, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109487



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-350, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL350
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-350, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109488



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-510, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL510
In Stock
2


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-510, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109489



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-540, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL540
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-540, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109490



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-580, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL580
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-580, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109491



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-590, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL590
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-590, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109492



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-660, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL660
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-660, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109493



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3516ANL Single Stage High Purity SS Regulator, CGA-705, Delivery Pressure Range 0-250 PSIG, SEQ3516ANL705
In Stock
3


Matheson Model 3516ANL Single Stage High Purity SS Regulator SEQ3516ANL, CGA-660, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1400 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: Vac-0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3516ANL regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3516ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109494



Price: ₱224,310.40



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, No Inlet, Delivery Pressure Range 0-500 PSIG, SEQ3517ANLNI
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANLNI, No Inlet, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109536



Price: ₱195,307.42



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-320, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL320
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-320, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109495



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-326, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL326
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-326, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109496



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-330, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL330
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-330, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109497



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-346, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL346
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-346, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109498



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-350, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL350
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-350, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109499



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-510, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL510
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-510, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109500



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-540, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL540
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-540, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109501



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-580, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL580
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-580, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109502



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-590, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL590
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-590, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109503



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-660, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL660
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-660, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109504



Price: ₱197,005.60



Currency: Philippine Peso (PHP)

Matheson Model 3517ANL Single Stage High Purity SS Regulator, CGA-705, Delivery Pressure Range 0-500 PSIG, SEQ3517ANL705
In Stock
1


Matheson Model 3517ANL Single Stage High Purity SS Regulator SEQ3517ANL, CGA-705, No Lube Assembly A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-705 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: Vac-0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated brass bonnet, and a Teflon seat. This Matheson series 3510A, model 3517ANL regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is suitable for any application requiring the supply of non-corrosive gases and some applications requiring the supply of semi-corrosive gases. This no lube model is assembled without the use of PCTFE. This allows the regulator to be used in applications where method detection limits are sub-particles per million. Gas Chromatography Detectors which can use the 3517ANL Regulator: Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Mass Selective Detector (MSD or MS) Atomic Emission Detector (AED) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109505



Price: ₱197,005.60



Currency: Philippine Peso (PHP)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com