Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-ro
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Adixen 2021C2 Pumps On Sale Agilent TriScroll Pumps On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Edwards nEXT300D TStations On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, No Inlet, Delivery Pressure Range 0-15 PSIG, SEQ3531ANI
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109537



Price: lei7,707.76



Currency: Romanian Leu (RON)

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, CGA-320, Delivery Pressure Range 0-15 PSIG, SEQ3531A320
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109254



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, CGA-326, Delivery Pressure Range 0-15 PSIG, SEQ3531A326
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109255



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, CGA-350, Delivery Pressure Range 0-15 PSIG, SEQ3531A350
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109256



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, CGA-510, Delivery Pressure Range 0-15 PSIG, SEQ3531A510
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is Matheson a Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109257



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, CGA-540, Delivery Pressure Range 0-15 PSIG, SEQ3531A540
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109258



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, CGA-580, Delivery Pressure Range 0-15 PSIG, SEQ3531A580
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109259



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator, CGA-590, Delivery Pressure Range 0-15 PSIG, SEQ3531A590
In Stock
1


Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109260



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, No Inlet, Delivery Pressure Range 0-250 PSIG, SEQ3536A
In Stock
2


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109538



Price: lei7,160.58



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, CGA-320, Delivery Pressure Range 0-250 PSIG, SEQ3536A320
In Stock
2


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109261



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, CGA-326, Delivery Pressure Range 0-250 PSIG, SEQ3536A326
In Stock
2


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2)M Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109262



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, CGA-350, Delivery Pressure Range 0-250 PSIG, SEQ3536A350
In Stock
2


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109264



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, CGA-510, Delivery Pressure Range 0-250 PSIG, SEQ3536A510
In Stock
2


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109265



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, CGA-540, Delivery Pressure Range 0-250 PSIG, SEQ3536A540
In Stock
2


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109266



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, CGA-580, Delivery Pressure Range 0-250 PSIG, SEQ3536A580
In Stock
1


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109267



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator, CGA-590, Delivery Pressure Range 0-250 PSIG, SEQ3536A590
In Stock
2


Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109268



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, No Inlet, Delivery Pressure Range 0-50 PSIG, SEQ3537ANI
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109539



Price: lei6,943.61



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, CGA-320, Delivery Pressure Range 0-50 PSIG, SEQ3537A320
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109269



Price: lei7,244.17



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, CGA-326, Delivery Pressure Range 0-50 PSIG, SEQ3537A326
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109270



Price: lei7,244.17



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, CGA-350, Delivery Pressure Range 0-50 PSIG, SEQ3537A350
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109271



Price: lei7,244.17



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, CGA-510, Delivery Pressure Range 0-50 PSIG, SEQ3537A510
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109272



Price: lei7,244.17



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, CGA-540, Delivery Pressure Range 0-50 PSIG, SEQ3537A540
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109273



Price: lei7,244.17



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, CGA-580, Delivery Pressure Range 0-50 PSIG, SEQ3537A580
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109274



Price: lei7,244.17



Currency: Romanian Leu (RON)

Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator, CGA-590, Delivery Pressure Range 0-50 PSIG, SEQ3537A590
In Stock
1


Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109275



Price: lei7,244.17



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, No Inlet, Delivery Pressure Range 0-500 PSIG, SEQ3538ANI
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109540



Price: lei7,707.76



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, CGA-320, Delivery Pressure Range 0-500 PSIG, SEQ3538A320
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109276



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, CGA-326, Delivery Pressure Range 0-500 PSIG, SEQ3538A326
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109277



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, CGA-350, Delivery Pressure Range 0-500 PSIG, SEQ3538A350
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109278



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, CGA-510, Delivery Pressure Range 0-500 PSIG, SEQ3538A510
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109279



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, CGA-540, Delivery Pressure Range 0-500 PSIG, SEQ3538A540
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109280



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, CGA-580, Delivery Pressure Range 0-500 PSIG, SEQ3538A580
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109281



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator, CGA-590, Delivery Pressure Range 0-500 PSIG, SEQ3538A590
In Stock
1


Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109282



Price: lei8,005.42



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, No Inlet, Delivery Pressure Range 0-125 PSIG, SEQ3539ANI
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109541



Price: lei7,160.58



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, CGA-320, Delivery Pressure Range 0-125 PSIG, SEQ3539A320
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109283



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, CGA-326, Delivery Pressure Range 0-125 PSIG, SEQ3539A326
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109284



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, CGA-350, Delivery Pressure Range 0-125 PSIG, SEQ3539A350
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109285



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, CGA-510, Delivery Pressure Range 0-125 PSIG, SEQ3539A510
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109286



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, CGA-540, Delivery Pressure Range 0-125 PSIG, SEQ3539A540
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109287



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, CGA-580, Delivery Pressure Range 0-125 PSIG, SEQ3539A580
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109289



Price: lei7,489.73



Currency: Romanian Leu (RON)

Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator, CGA-590, Delivery Pressure Range 0-125 PSIG, SEQ3539A590
In Stock
1


Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109290



Price: lei7,489.73



Currency: Romanian Leu (RON)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com