Agilent Varian Helium Leak Detectors On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nEXT300D TStations On Sale Agilent TriScroll Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Edwards im Applied Smart Interface Module for iQDP, iH, & iL Semiconductor. PN: A52844410
In Stock
2


Edwards im Applied Smart Interface Module for iQDP, iH, & iL Semiconductor Vacuum Pump. Edwards Part Number A52844410. The Interface Module allows you to use your own control equipment to control the operation of and to monitor the status of an iH, iL or iQ dry pumping system. Edwards Interface Module for iH, iL, & iQDP Dry Semiconductor Vacuum Pumps, Close Contactors 1 & 14 to Start Pump Externally, Monitor Pump Status With Contacts 8 & 20 - Closed Contact When Pump Running - Open Contact While When Stops. Brand New Module. Edwards part number: A52844410. For example, you can connect the Interface Module to the serial port of a PC (Personal Computer) on which you have installed a suitable SCADA (Supervisory Control And Data Acquisition program). All information sent to or received from the Communications Module (whether serial or parallel data) is software derived; there is no direct electrical wiring to the sensors, pumps or valves in the dry pumping system. Download the .pdf users manual at AVAILABLE DOWNLOADS.

Condition: New



Part Number: P105364



Price: lei26,643.99




Currency: Romanian Leu (RON)

Refurbished Edwards im Applied Smart Interface Module for iQDP, iH, & iL Semiconductor. PN: A52844410
Out of Stock


Refurbished Edwards im Applied Smart Interface Module for iQDP, iH, & iL Semiconductor Vacuum Pump. Edwards Part Number A52844410. The Interface Module allows you to use your own control equipment to control the operation of and to monitor the status of an iH, iL or iQ dry pumping system. Edwards Interface Module for iH, iL, & iQDP Dry Semiconductor Vacuum Pumps, Close Contactors 1 & 14 to Start Pump Externally, Monitor Pump Status With Contacts 8 & 20 - Closed Contact When Pump Running - Open Contact While When Stops. Brand New Module. Edwards part number: A52844410 For example, you can connect the Interface Module to the serial port of a PC (Personal Computer) on which you have installed a suitable SCADA (Supervisory Control And Data Acquisition program). All information sent to or received from the Communications Module (whether serial or parallel data) is software derived; there is no direct electrical wiring to the sensors, pumps or valves in the dry pumping system. Download the .pdf users manual at AVAILABLE DOWNLOADS.

Condition: Rebuilt



Part Number: P1012172



Price: lei7,977.32




Currency: Romanian Leu (RON)

Rebuilt Edwards im Interface Module for iQDP, iH, & iL Semiconductor Vacuum Pumps PN: A52844463
Out of Stock


Rebuilt Edwards im Interface Module for iQDP, iH, & iL Semiconductor Vacuum Pump. PN: A528-44-463 The Interface Module allows you to use your own control equipment to control the operation of and to monitor the status of an iH, iL or iQ dry pumping systems. The Edwards Interface Module is designed for use with the Edwards iQ, iH & iL dry pumping systems and allows you to connect the pumping system to other equipment. For example, your Process Tool or other control equipment. This module has 2 Interface cards, the Tool Interface Card and the Auxiliary Interface card. This is model A528-44-463R. For installation, operation and maintenance instructions see the .pdf Instruction Manual below at AVAILABLE DOWNLOADS.

Condition: Rebuilt



Part Number: P105365



Price: lei8,535.74



Currency: Romanian Leu (RON)

Edwards iM Serial Port PC Communications Module for iQDP, iH, & iL Semiconductor Vacuum Pumps. PN: D372-32-000.
In Stock
1


Edwards iM Serial Port PC Communications Module for iQDP, iH, & iL Semiconductor Vacuum Pumps. Edwards Part Number: D372-32-000. This iM serial port communications module allows you to use your computer to control the operation of and to monitor the status of an iH, iL or iQ dry pumping system through the module''s internal serial communication card via RS232 protocol. For example, you can connect the Communications Module to the serial port of a PC on which you have installed a suitable SCADA (Supervisory Control And Data Acquisition program). All serial information sent to or received from the Communications Module is software derived; there is no direct electrical wiring to the sensors, pumps or valves in the dry pumping system. The communications module is connected to the Edwards iQDP, iH, or iL semiconductor vacuum pump system via an included 4 pin XLR cable (part number P108148). The module has a serial 9 pin DIN connector for connection to the control equipment (PLC or compuer). Use a serial to USB cable to connect to a system that doesn''t have a serial port (part number P1010935). Please download the available manual.

Condition: New



Part Number: P103634



Price: lei9,699.78




Currency: Romanian Leu (RON)

New Edwards iTIM MCM & L1 & Gate Valve Control for iH Dry Pumps, PN D37422000
In Stock
2


Edwards iTIM MCM & L1 Gate Valve Control for iH pumps and other series Edwards Pumps. PN D37422000An iTIM may be used to provide control and monitoring of the iH pump by your Process Tool, using a parallel digital interface. The iTIM has a number of advanced features. • Digital connections for up to 3 different types of tool interface on each iTIM.• Convenient mounting on the rear of the pump, rapid two point fixing.• Configurable connectivity to enable AUC functionality to be readily customised.• Gate valve control is included in this module as standard.• The iTIM has a set point store, which allows pump set points relating to a particular process or recipe to be saved. These set points are automatically to be loaded into pump on power up, including new pumps when one is replaced. Where these modules already exist they may be utilised to provide control and monitoring of the pump by your Process Tool or other control equipment. For example a pump may be upgraded from an iH to an iHs without changing the interface module. However the iTIM provides improved performance over the iM modules, for example full AUC functionality is only available using the iTIM. The iTIM is recommended on all new installations. For further instructions call us at 505-872-0037.

Condition: New



Part Number: P1011149



Price: lei9,390.29



Currency: Romanian Leu (RON)

Edwards iTIM E73 & Al & T1 & Gate Valve Control for iH Dry Pumps. PN: D37420000
In Stock
1


Edwards iTIM E73 & Al & T1 & Gate Valve Control for iH pumps. PN: D37420000. An iTIM may be used to provide control and monitoring of the IH pump by your Process Tool, using a parallel digital interface. The iTIM has a number of advanced features. • Digital connections for up to 3 different types of tool interface on each iTIM.• Convenient mounting on the rear of the pump, rapid two point fixing.• Configurable connectivity to enable AUC functionality to be readily customised.• Gate valve control is included in this module as standard.• The iTIM has a set point store, which allows pump set points relating to a particular process or recipe to be saved. These set points are automatically to be loaded into pump on power up, including new pumps when one is replaced. Where these modules already exist they may be utilised to provide control and monitoring of the pump by your Process Tool or other control equipment. For example a pump may be upgraded from an iH to an iHs without changing the interface module. However the iTIM provides improved performance over the iM modules, for example full AUC functionality is only available using the iTIM. The iTIM is recommended on all new installations. For further instructions call us at 505-872-0037.

Condition: New



Part Number: P107498



Price: lei9,505.69




Currency: Romanian Leu (RON)

Edwards GX, iGX, iXH, iXM, and iXL Pump Display Terminal, 5Way, XLR Plug, Hand Held Key Pad Display Module. PN: D37280700
In Stock
2
Expecting 6
Anticipated Arrival 6 on 2025-09-12


Edwards GX, iGX, iXH, iXM, and iXL Pump Display Terminal, 5Way, XLR Plug, Hand Held Key Pad Display Module. Edwards Part Number: D37280700 Edwards GX, iGX, iXH, IXM, and iXL Pump Display Terminal 5 Way XLR Plug. Hand held display for Edwards GX, iGX and iXL120 Series Dry Pump Systems with 5 way XLR connection. Edwards Vacuum Part Number D37280700.

Condition: New



Part Number: P107574



Price: lei7,987.44




Currency: Romanian Leu (RON)

Edwards iH and iL Dry Semiconductor Vacuum Pump Key Pad Display Module. PN: D37237000
Out of Stock


Edwards iH and iL Dry Semiconductor Vacuum Pump Key Pad Display Module D37237000 These Edwards iH and iL semiconductor dry pump Key Pad Display Module are used to connect to Edwards im Applied Smart Interface Module to control your iQDP pumps. The Key Pad Display Module also connects to the iH or iL electric module and allows the user to take local control of iH and iL series vacuum pumps. The display module can be used to start and stop the pump and change internal settings, such as, open gas ballast and other functions. These Edwards iH and iL display modules are equipped with cable and connector as shown. These are new with Edwards part number, D37237000

Condition: New



Part Number: P105414



Price: lei6,391.28




Currency: Romanian Leu (RON)

Refurbished Edwards iH and iL Dry Semiconductor Vacuum Pump Key Pad Display Module with Phone Jack. Refurb. PN: D37272000
In Stock
22


Refurbished Edwards iH and iL Dry Semiconductor Vacuum Pump Key Pad Display Module Edwards Part Number D37272000 These Edwards iH and iL semiconductor dry pump Refurbished Display Modules "Key Pads" with phone jack are used to connect a user interface to your iQDP pumps. The display modules connect to the iH or iL electric module and allows the user to take local control of iH and iL series vacuum pumps. The display module can be used to start and stop the pump and change internal settings, such as, open gas ballast and other functions. These Edwards iH and iL display modules are equipped with cable and connector as shown. These are REFURBISHED, with Edwards part number, D37272000

Condition: Refurbished



Part Number: P106104



Price: lei2,557.48




Currency: Romanian Leu (RON)

Edwards XLR 4 Pin Cable Connects iM Communications Module to iQDP, iH, & iL Semiconductor Vacuum Pumps, 0.6 Meters Long. PN: D37207602.
Out of Stock


Edwards XLR 4 Pin Cable Connects iM Communications Module to iQDP, iH, & iL Semiconductor Vacuum Pumps, 0.6 Meters Long. Edwards Part Number: D37207602. This Edwards OEM 0.6 meter long XLR 4 pin cable connects the Edwards iM Communications Module (P103634) to an iQDP, iH, or iL semiconductor vacuum pump. The iM serial port communications module allows you to use a PLC or a computer to control the operation of and to monitor the status of an iH, iL or iQ dry pumping system through the module''s internal serial communication card via RS232. For example, you can connect the Communications Module to the serial port of a PC on which you have installed a suitable SCADA (Supervisory Control And Data Acquisition program). All serial information sent to or received from the Communications Module is software derived; there is no direct electrical wiring to the sensors, pumps or valves in the dry pumping system. The communications module is connected to the Edwards iQDP, iH, or iL semiconductor vacuum pump system with this 4 pin XLR cable. The module has a serial 9 pin DIN connector for connection to the control equipment (PLC or compuer). Use a serial to USB cable to connect to a system that doesn''t have a serial port (part number P1010935). Please download the available manual.

Condition: New



Part Number: P108148



Price: lei2,017.10




Currency: Romanian Leu (RON)
Marca de agua con el logotipo de Ideal Vacuum