Dual Tungsten Filament Glass Ion Gauge Tube, Bayard-Alpert Style, 1 inch Port, Vacuum Pressure Gauge These dual tungsten glass ion gauge tubes have a 1 inch port vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC). The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy. Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With: Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others. MKS Instruments 290, 919, 929 Perkin Elmer DGC3 Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 572 Tube K7360301 Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002
Condition: New
Part Number: P102041
Price: lei1,067.24
Dual Tungsten Filament Glass Ion Gauge Tube, Bayard-Alpert Style, KF-25 Port, Vacuum Pressure Gauge These dual tungsten glass ion gauge tubes have a ISO KF-25 vacuum connection flange and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC). The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy. Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With: Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others. MKS Instruments 290, 919, 929 Perkin Elmer DGC3 Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 572 Tube K7360305 Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002
Condition: New
Part Number: P102042
Price: lei1,431.81
Dual Tungsten Filament Glass Ion Gauge Tube, Bayard-Alpert Style, KF40 Port, Vacuum Pressure Gauge These dual tungsten glass ion gauge tubes have a ISO KF-40 vacuum connection flange and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC). The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy. Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With: Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others. MKS Instruments 290, 919, 929 Perkin Elmer DGC3 Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 572 Tube K7360306 Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002
Condition: New
Part Number: P102040
Price: lei1,255.05
Dual Tungsten Filament Glass Ion Gauge Tube, Bayard-Alpert Style, CF 1.33 Port, Vacuum Pressure GaugeThese dual tungsten glass ion gauge tubes have a Conflat 1.33 inch vacuum connection flange and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC).The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy.Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco.Typically Works With:Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others.MKS Instruments 290, 919, 929Perkin Elmer DGC3Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 572 TubeVeeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002
Condition: New
Part Number: P102043
Price: lei1,258.35
Dual Tungsten Filament Glass Ion Gauge Tube, Bayard-Alpert Style, CF 2.75 Port, Vacuum Pressure Gauge These dual tungsten glass ion gauge tubes have a Conflat 2.75 inch vacuum connection flange and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC). The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy. Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. Typically Works With: Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others. MKS Instruments 290, 919, 929 Perkin Elmer DGC3 Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 572 Tube K7360307 Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002
Condition: New
Part Number: P102044
Price: lei1,503.04