Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-se
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Edwards nXR Multi Stage Roots Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Adixen 2021C2 Pumps On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

CGA-110 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ1104SS
In Stock
3


CGA-110 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ1104SS. This is a CGA-110 to 1/4" MNPT stainless steel fitting with included Teflon washer. Nipple length is 1.25 in. This size CGA fitting is typically used to connect regulators to small compressed gas cylinders (lecture bottles) in labs working with small quantities of gases or specialty gases. This CGA-110 fitting, PN: SEQ1104SS, is rated for use with all types of gases in small cylinders up to 3000 psig. The Teflon washer is not typically reuseable. See part number P1012967 for replacement washers. CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1010961



Price: Kr2,724.29




Currency: Swedish Krona (SEK)

CGA-170 Gas Regulator Inlet to 1/8" Male NPT Fitting, Stainless Steel, Short, PN: SEQ1702SS
In Stock
2


CGA-170 Gas Regulator Inlet to 1/8" Male NPT Fitting, Stainless Steel, Short, PN: SEQ1702SS. This is a CGA-170 to 1/8" MNPT stainless steel fitting with included Teflon washer. Nipple length is 1.25 in. This size CGA fitting is typically used to connect regulators to small compressed gas cylinders (lecture bottles) in labs working with small quantities of gases or specialty gases. This CGA-170 fitting, PN: SEQ1702SS, is rated for use with non-corrosive gases in small cylinders up to 3000 psig. The Teflon washer is not typically reuseable. See part number P1012968 for replacement washers. CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012039



Price: Kr1,669.41




Currency: Swedish Krona (SEK)

CGA-180 Gas Regulator Inlet to 1/8" Male NPT Fitting, Stainless Steel, Short, PN: SEQ1802SS
In Stock
10


CGA-180 Gas Regulator Inlet to 1/8" Male NPT Fitting, Stainless Steel, Short, PN: SEQ1802SS. This is a CGA-180 to 1/8" MNPT stainless steel fitting with included Teflon washer. Nipple length is 1.25 in. This size CGA fitting is typically used to connect regulators to small compressed gas cylinders (lecture bottles) in labs working with small quantities of gases or specialty gases. This CGA-180 fitting, PN: SEQ1802SS, is rated for use with all types of gases in small cylinders up to 3000 psig. The Teflon washer is not typically reuseable. See part number P1012969 for replacement washers. CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1010960



Price: Kr2,599.34




Currency: Swedish Krona (SEK)

CGA-240 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ2404SS
In Stock
2


CGA-240 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ2404SS. This is a CGA-240 to 1/4" MNPT stainless steel fitting. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 500 psig. This CGA-240 fitting, PN: SEQ2404SS, is rated for use with the gases listed below. CGA-240 for use with: Ammonia CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012044



Price: Kr2,148.36




Currency: Swedish Krona (SEK)

CGA-296 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3204SSL
In Stock
7


CGA-296 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3204SSL. This is a CGA-296 to 1/4" MNPT stainless steel fitting. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-296 fitting, PN: SEQ3204SSL, is rated for use with the gases listed below. CGA-296 for use with: Certain Oxidizing Mixtures CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109507



Price: Kr2,179.63




Currency: Swedish Krona (SEK)

CGA-320 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3204SSL
In Stock
4


CGA-320 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3204SSL. This is a LONG CGA-320 to 1/4" MNPT stainless steel fitting with included Teflon washer. Nipple length is 2.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-320 fitting, PN: SEQ3204SSL, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012970 for replacement washers. CGA-320 for use with: Carbon Dioxide Methyl Fluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109508



Price: Kr2,066.64




Currency: Swedish Krona (SEK)

CGA-320 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ3204BPL
In Stock
2


CGA-320 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ3204BPL. This is a LONG CGA-320 to 1/4" MNPT nickel-plated brass fitting with included Teflon washer. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-320 fitting, PN: SEQ3204BPL, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012970 for replacement washers. CGA-320 for use with: Carbon Dioxide CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109509



Price: Kr1,288.87




Currency: Swedish Krona (SEK)

CGA-320 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ3204SS
In Stock
2


CGA-320 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ3204SS. This is a SHORT CGA-320 to 1/4" MNPT stainless steel fitting with included Teflon washer. Nipple length is 1.75 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-320 fitting, PN: SEQ3204SSL, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012970 for replacement washers. CGA-320 for use with: Carbon Dioxide Methyl Fluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012025



Price: Kr1,896.71




Currency: Swedish Krona (SEK)

CGA-326 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3264SSL
In Stock
5


CGA-326 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3264SSL. This is a long CGA-326 to 1/4" MNPT stainless steel fitting. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-326 fitting, PN: SEQ3264SSL, is rated for use with the gases listed below. CGA-326 for use with: Nitrous Oxide CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109510



Price: Kr2,170.20




Currency: Swedish Krona (SEK)

CGA-326 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ3264BPL
In Stock
6


CGA-326 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ3264BPL. This is a long CGA-326 to 1/4" MNPT nickel-plated brass fitting. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-326 fitting, PN: SEQ3264BPL, is rated for use with the gases listed below. CGA-326 for use with: Nitrous Oxide CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109511



Price: Kr1,243.56




Currency: Swedish Krona (SEK)

CGA-330 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3304SSL
In Stock
17


CGA-330 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3204SSL. This is a LONG CGA-330 to 1/4" MNPT stainless steel fitting with left-handed threads and included Teflon washer. Nipple length is 2.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-330 fitting, PN: SEQ3304SSL, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012970 for replacement washers. CGA-330 for use with: Hydrogen Chloride Hydrogen Bromide Antimony Pentafluoride Boron Trifluoride Carbonyl Sulfide Deuterium Chloride Deuterium Sulfide Hexafluoroacetone Hydrogen Bromide Hydrogen Chloride Hydrogen Iodide Hydrogen Sulfide Methyl Bromide Methyl Mercaptan Nitrogen Trifluoride Nitrosyl Chloride Nitrosyl Fluoride Nitryl Fluoride Phenylcarbylamine Chloride Phosphorous Pentafluoride Phosphorous Trifluoride Silicon Tetrafluoride Sulfur Tetrafluoride Trifluoroacetyl Chloride Uranium Hexafluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109512



Price: Kr2,170.20




Currency: Swedish Krona (SEK)

CGA-330 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ3304SS
In Stock
2


CGA-330 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ3304SS. This is a SHORT CGA-330 to 1/4" MNPT stainless steel fitting with left-handed threads and included Teflon washer. Nipple length is 1.75 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-330 fitting, PN: SEQ3304SS, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012970 for replacement washers. CGA-330 for use with: Hydrogen Chloride Hydrogen Bromide Antimony Pentafluoride Boron Trifluoride Carbonyl Sulfide Deuterium Chloride Deuterium Sulfide Hexafluoroacetone Hydrogen Bromide Hydrogen Chloride Hydrogen Iodide Hydrogen Sulfide Methyl Bromide Methyl Mercaptan Nitrogen Trifluoride Nitrosyl Chloride Nitrosyl Fluoride Nitryl Fluoride Phenylcarbylamine Chloride Phosphorous Pentafluoride Phosphorous Trifluoride Silicon Tetrafluoride Sulfur Tetrafluoride Trifluoroacetyl Chloride Uranium Hexafluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012026



Price: Kr2,149.57




Currency: Swedish Krona (SEK)

CGA-346 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3464SSL
In Stock
4


CGA-346 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3464SSL. This is a long CGA-346 to 1/4" MNPT stainless steel fitting. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-346 fitting, PN: SEQ3464SSL, is rated for use with the gases listed below. CGA-346 for use with: Breathing Air CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109513



Price: Kr1,399.88




Currency: Swedish Krona (SEK)

CGA-346 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ3464SS
In Stock
2


CGA-346 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ3464SS. This is a short CGA-346 to 1/4" MNPT stainless steel fitting. Nipple length is 2.25 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-346 fitting, PN: SEQ3464SS, is rated for use with the gases listed below. CGA-346 for use with: Breathing Air CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012027



Price: Kr1,244.55




Currency: Swedish Krona (SEK)

CGA-350 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ3504SSL
In Stock
17


CGA-350 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN:SEQ3504SSL. This is a long CGA-350 to 1/4" MNPT stainless steel fitting with left-handed threads. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-350 fitting, PN: SEQ3504SSL, is rated for use with the gases listed below. CGA-350 for use with: Hydrogen Methane Carbon Monoxide Arsine Deuterium Deuterium Selenide Diborane 1,1 Difluoroethylene Ethane Ethylene Germane Hydrogen Selenide Methyl Fluoride Methylene Fluoride Natural Gas Pentaborane Phosphine Silane Stibine Tetrafluoroethylene Vinyl Fluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109514



Price: Kr2,001.15




Currency: Swedish Krona (SEK)

CGA-350 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ3504BPL
In Stock
2


CGA-350 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ3504BPL. This is a long CGA-350 to 1/4" MNPT nickel-plated brass fitting with left-handed threads. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-350 fitting, PN: SEQ3504BpL, is rated for use with the gases listed below. CGA-350 for use with: Hydrogen Methane Carbon Monoxide Arsine Deuterium Deuterium Selenide Diborane 1,1 Difluoroethylene Ethane Ethylene Germane Hydrogen Selenide Methyl Fluoride Methylene Fluoride Natural Gas Pentaborane Phosphine Silane Stibine Tetrafluoroethylene Vinyl Fluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109515



Price: Kr1,245.64




Currency: Swedish Krona (SEK)

CGA-350 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ3504SS
In Stock
8


CGA-350 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN:SEQ3504SS. This is a short CGA-350 to 1/4" MNPT stainless steel fitting with left-handed threads. Nipple length is 2.25 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-350 fitting, PN: SEQ3504SS, is rated for use with the gases listed below. CGA-350 for use with: Hydrogen Methane Carbon Monoxide Arsine Deuterium Deuterium Selenide Diborane 1,1 Difluoroethylene Ethane Ethylene Germane Hydrogen Selenide Methyl Fluoride Methylene Fluoride Natural Gas Pentaborane Phosphine Silane Stibine Tetrafluoroethylene Vinyl Fluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012028



Price: Kr1,286.56




Currency: Swedish Krona (SEK)

CGA-510 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5104SSL
In Stock
2


CGA-510 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5104SSL. This is a long CGA-510 to 1/4" MNPT stainless steel fitting with left-handed threads. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 500 psig. This CGA-510 fitting, PN: SEQ5104SSL, is rated for use with the gases listed below. CGA-510 for use with: Acetylene Allene Bromotrifluoroethylene 1,3-Butadiene Butane 1-Butene 2-Butene 1-Chloro-1,1-difluoroethane Chlorofluoromethane Chlorotrifluoroethylene Cyclobutane Cyclopropane Diethylzinc 1,1-Difluoroethane Dimethyl Ether 2,2 Dimethylpropane Ethylacetylene Ethylene Oxide Ethyl Ether Isobutane Isobutylene Methane Methylacetylene 3-Methyl-1-Butene Methyl Chloride Methyl Ethyl Ether Natural Gas, Propane Propylene Silane Triethylaluminum 1,1,1 Trifluoroethane Trifluoroethylene Vinyl Bromide Vinyl Chloride Vinyl Methyl Ether CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109516



Price: Kr2,170.20




Currency: Swedish Krona (SEK)

CGA-510 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5104BPL
In Stock
4


CGA-510 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5104BPL. This is a long CGA-510 to 1/4" MNPT nickel-plated brass fitting with left-handed threads. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 500 psig. This CGA-510 fitting, PN: SEQ5104SSL, is rated for use with the gases listed below. CGA-510 for use with: Acetylene Allene Bromotrifluoroethylene 1,3-Butadiene Butane 1-Butene 2-Butene 1-Chloro-1,1-difluoroethane Chlorofluoromethane Chlorotrifluoroethylene Cyclobutane Cyclopropane Diethylzinc 1,1-Difluoroethane Dimethyl Ether 2,2 Dimethylpropane Ethylacetylene Ethylene Oxide Ethyl Ether Isobutane Isobutylene Methane Methylacetylene 3-Methyl-1-Butene Methyl Chloride Methyl Ethyl Ether Natural Gas, Propane Propylene Silane Triethylaluminum 1,1,1 Trifluoroethane Trifluoroethylene Vinyl Bromide Vinyl Chloride Vinyl Methyl Ether CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109517



Price: Kr1,149.11




Currency: Swedish Krona (SEK)

CGA-510 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ5104SS
In Stock
2


CGA-510 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ5104SS. This is a short CGA-510 to 1/4" MNPT stainless steel fitting with left-handed threads. Nipple length is 2.63 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 500 psig. This CGA-510 fitting, PN: SEQ5104SS, is rated for use with the gases listed below. CGA-510 for use with: Acetylene Allene Bromotrifluoroethylene 1,3-Butadiene Butane 1-Butene 2-Butene 1-Chloro-1,1-difluoroethane Chlorofluoromethane Chlorotrifluoroethylene Cyclobutane Cyclopropane Diethylzinc 1,1-Difluoroethane Dimethyl Ether 2,2 Dimethylpropane Ethylacetylene Ethylene Oxide Ethyl Ether Isobutane Isobutylene Methane Methylacetylene 3-Methyl-1-Butene Methyl Chloride Methyl Ethyl Ether Natural Gas, Propane Propylene Silane Triethylaluminum 1,1,1 Trifluoroethane Trifluoroethylene Vinyl Bromide Vinyl Chloride Vinyl Methyl Ether CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012030



Price: Kr1,341.74




Currency: Swedish Krona (SEK)

CGA-540 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5404SSL
In Stock
4


CGA-540 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5404SSL. This is a long CGA-540 to 1/4" MNPT stainless steel fitting. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-540 fitting, PN: SEQ5404SSL, is rated for use with the gases listed below. CGA-540 for use with: Oxygen CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109518



Price: Kr2,001.15




Currency: Swedish Krona (SEK)

CGA-540 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5404BPL
In Stock
2


CGA-540 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5404BPL. This is a long CGA-540 to 1/4" MNPT nickel-plated brass fitting. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-540 fitting, PN: SEQ5404BPL, is rated for use with the gases listed below. CGA-540 for use with: Oxygen CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109519



Price: Kr1,245.64




Currency: Swedish Krona (SEK)

CGA-540 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ5404SS
In Stock
2


CGA-540 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, PN: SEQ5404SS. This is a short CGA-540 to 1/4" MNPT stainless steel fitting. Nipple length is 2.25 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 3000 psig. This CGA-540 fitting, PN: SEQ5404SS, is rated for use with the gases listed below. CGA-540 for use with: Oxygen CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1012031



Price: Kr1,773.85




Currency: Swedish Krona (SEK)

CGA-580 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for O2 Use, PN: SEQ5804SS
In Stock
2


CGA-580 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for O2 Use, PN: SEQ5804SS. This is a short CGA-580 to 1/4" MNPT stainless steel fitting. Nipple length is 2.63 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 3000 psig. This CGA-580 fitting, PN: SEQ5804SS, is rated for use with the gases listed below. CGA-580 for use with: Specially Cleaned and approved for Oxygen Use Argon Helium Krypton Neon Nitrogen Tetrafluoromethane Xenon CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1011175



Price: Kr1,952.88




Currency: Swedish Krona (SEK)

CGA-580 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5804SSL
In Stock
27


CGA-580 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5804SSL. This is a long CGA-580 to 1/4" MNPT stainless steel fitting. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 3000 psig. This CGA-580 fitting, PN: SEQ5804SSL, is rated for use with the gases listed below. CGA-580 for use with: Argon Helium Krypton Neon Nitrogen Tetrafluoromethane Xenon CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109520



Price: Kr2,549.87




Currency: Swedish Krona (SEK)

CGA-580 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5804BPL
In Stock
1
Expecting 3
Anticipated Arrival 3 on 2024-12-20


CGA-580 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5804BPL. This is a long CGA-580 to 1/4" MNPT nickel-plated brass fitting. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 3000 psig. This CGA-580 fitting, PN: SEQ5804BPL, is rated for use with the gases listed below. CGA-580 for use with: Argon Helium Krypton Neon Nitrogen Tetrafluoromethane Xenon CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109521



Price: Kr1,325.07




Currency: Swedish Krona (SEK)

CGA-590 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for O2 Use, PN: SEQ5904SS
In Stock
2


CGA-590 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for O2 Use, PN: SEQ5904SS. This is a short CGA-590 to 1/4" MNPT stainless steel fitting. Nipple length is 2.63 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 3000 psig. This CGA-590 fitting, PN: SEQ5904SS, is rated for use with the gases listed below. CGA-590 for use with: Specially Cleaned and approved for Oxygen Use Zero Air Sulfer Hexafluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1011176



Price: Kr1,952.99




Currency: Swedish Krona (SEK)

CGA-590 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5904SSL
In Stock
24


CGA-590 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ5904SSL. This is a long CGA-590 to 1/4" MNPT stainless steel fitting. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 3000 psig. This CGA-590 fitting, PN: SEQ5904SSL, is rated for use with the gases listed below. CGA-590 for use with: Zero Air Sulfer Hexafluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109522



Price: Kr2,129.28




Currency: Swedish Krona (SEK)

CGA-590 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5904BPL
In Stock
6


CGA-590 Gas Regulator Inlet to 1/4" Male NPT Fitting, Nickel-Plated Brass, Long, PN: SEQ5904BPL. This is a long CGA-590 to 1/4" MNPT nickel-plated brass fitting. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and included Viton O-ring and a maximum pressure of 3000 psig. This CGA-590 fitting, PN: SEQ5904BPL, is rated for use with the gases listed below. CGA-590 for use with: Zero Air Sulfer Hexafluoride CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109523



Price: Kr1,279.65




Currency: Swedish Krona (SEK)

CGA-660 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for Oxygen Use, PN: SEQ6604SS
In Stock
29


CGA-660 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for Oxygen Use, PN: SEQ6604SS. This is a SHORT CGA-660 to 1/4" MNPT stainless steel fitting and included Teflon washer. Nipple length is 1.88 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-660 fitting, PN: SEQ6604SSL, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012972 for replacement washers. CGA-660 for use with: Specially Cleaned and approved for Oxygen Use Ammonia Chlorine Sulfer Dioxide CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1011177



Price: Kr2,088.58




Currency: Swedish Krona (SEK)

CGA-660 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ6604SSL
In Stock
24


CGA-660 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ6604SSL. This is a LONG CGA-660 to 1/4" MNPT stainless steel fitting and included Teflon washer. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-660 fitting, PN: SEQ6604SSL, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012972 for replacement washers. CGA-660 for use with: Ammonia Chlorine Sulfer Dioxide CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109524



Price: Kr2,502.26




Currency: Swedish Krona (SEK)

CGA-695 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for O2 Use, PN: SEQ69544SS
In Stock
2


CGA-695 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for O2 Use, PN: SEQ69544SS. This is a short CGA-695 to 1/4" MNPT stainless steel fitting with left-handed threads. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a metal-to-metal seal and a maximum pressure of 4700 psig. This CGA-695 fitting, PN: SEQ69544SS, is rated for use with the gases listed below. CGA-695 for use with: Specially Cleaned and approved for Oxygen Use Hydrogen Methane CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1011179



Price: Kr3,172.30




Currency: Swedish Krona (SEK)

CGA-705 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for Oxygen Use, PN: SEQ7054SS
In Stock
2


CGA-705 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Short, Cleaned for Oxygen Use, PN: SEQ7054SS. This is a SHORT CGA-705 to 1/4" MNPT stainless steel fitting and included Teflon washer. Nipple length is 3.0 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-705 fitting, PN: SEQ7054SS, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012975 for replacement washers. CGA-705 for use with: Specially Cleaned and approved for Oxygen Use Ammonia CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P1011180



Price: Kr3,515.89




Currency: Swedish Krona (SEK)

CGA-705 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, Cleaned for Oxygen Use, PN: SEQ7054SSL
In Stock
8


CGA-705 Gas Regulator Inlet to 1/4" Male NPT Fitting, Stainless Steel, Long, PN: SEQ7054SSL. This is a LONG CGA-705 to 1/4" MNPT stainless steel fitting and included Teflon washer. Nipple length is 3.5 in. This size CGA fitting is used to connect regulators to compressed gas cylinders with a flat gasketed seal and a maximum pressure of 3000 psig. This CGA-705 fitting, PN: SEQ7054SSL, is rated for use with the gases listed below. The Teflon washer is not typically reuseable. See part number P1012975 for replacement washers. CGA-705 for use with: Ammonia CGA fittings are standardized and authorized for the attachment of regulators and transfer lines to gas cylinders filled with specific gases at defined maximum pressures. The three digit number, CGA (XXX), corresponds to the specific gases for which that fitting is tailored (see the downloads). Connections to cylinders should never be forced. CGA fittings mated between regulator and cylinder never use pipe dope or PTFE tape. CGA connections use either a bullet-nose or gasketed seal. The bullet nose connection has a metal-to-metal contact and seal. Some bullet-nose connections have an o-ring to help improve the seal and to allow a connection to be made without a wrench (hand-tight connections). A gasketd connection requires a flat washer to make the seal. CGA fittings are available in several materials including brass, stainless steel, nickel or chrome-plated brass, and Monel. The CGA fitting material to use depends on the gas and cylinder pressure.

Condition: New



Part Number: P109525



Price: Kr3,760.85




Currency: Swedish Krona (SEK)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com