Keyword Part Number:
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109537
Price: Kr18,421.37
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109254
Price: Kr19,132.78
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109255
Price: Kr19,132.78
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109256
Price: Kr19,132.78
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is Matheson a Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109257
Price: Kr19,132.78
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109258
Price: Kr19,132.78
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109259
Price: Kr19,132.78
Matheson Model 3531A Single Stage High Purity Chrome Plated Brass Regulator SEQ3531A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 650 SCFH (305 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-15 PSIG Delivery Pressure Gauge: Vac-0-30 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3531A regulator is to be used in applications requiring delivery pressures up to 15 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3531A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109260
Price: Kr19,132.78
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109538
Price: Kr17,113.64
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109261
Price: Kr17,900.30
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2)M Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109262
Price: Kr17,900.30
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109264
Price: Kr17,900.30
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109265
Price: Kr17,900.30
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109266
Price: Kr17,900.30
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatorgraphy applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109267
Price: Kr17,900.30
Matheson Model 3536A Single Stage High Purity Chrome Plated Brass Regulator SEQ3536A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 3000 SCFH (1410 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-250 PSIG Delivery Pressure Gauge: 0-400 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3536A regulator is to be used in applications requiring delivery pressures up to 250 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3536A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109268
Price: Kr17,900.30
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109539
Price: Kr16,595.09
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109269
Price: Kr17,313.40
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109270
Price: Kr17,313.40
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109271
Price: Kr17,313.40
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109272
Price: Kr17,313.40
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109273
Price: Kr17,313.40
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109274
Price: Kr17,313.40
Matheson Model 3537A Single Stage High Purity Chrome Plated Brass Regulator SEQ3537A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 1100 SCFH (517 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-50 PSIG Delivery Pressure Gauge: Vac-0-100 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3537A regulator is to be used in applications requiring delivery pressures up to 50 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3537A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109275
Price: Kr17,313.40
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109540
Price: Kr18,421.37
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109276
Price: Kr19,132.78
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109277
Price: Kr19,132.78
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109278
Price: Kr19,132.78
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109279
Price: Kr19,132.78
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109280
Price: Kr19,132.78
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109281
Price: Kr19,132.78
Matheson Model 3538A Single Stage High Purity Chrome Plated Brass Regulator SEQ3538A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4500 SCFH (2115 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-500 PSIG Delivery Pressure Gauge: 0-1000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3538A regulator is to be used in applications requiring delivery pressures up to 500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3538A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109282
Price: Kr19,132.78
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109541
Price: Kr17,113.64
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109283
Price: Kr17,900.30
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109284
Price: Kr17,900.30
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109285
Price: Kr17,900.30
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109286
Price: Kr17,900.30
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109287
Price: Kr17,900.30
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109289
Price: Kr17,900.30
Matheson Model 3539A Single Stage High Purity Chrome Plated Brass Regulator SEQ3539A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Nickel Plated Brass CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 2400 SCFH (1128 SLPM)(At 2000 psig, N2) Flow Capacity (Cv): 0.08 Operating Temperature: -15°F to 140°F (-26°C to 60°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 3 High, 3 Low Delivery Pressure Range: 0-125 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Chrome Plated Brass regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, chrome plated bonnet, and a Teflon seat. This Matheson series 3530A, model 3539A regulator is to be used in applications requiring delivery pressures up to 125 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of chromatography applications requiring the supply of carrier gas/detector support gas. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only). Gas Chromatography Detectors which can use the 3539A Regulator: Flame Ionization Detector (FID) Thermal Conductivity Detector (TCD) Nitrogen Phosphorus Detector (NPD) Flame Photometric Detector (FPD) Photoionization Detector (PID) Electrolytic Conductivity Detector (ELCD or Hall Detector) Electron Capture Detector (ECD) Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Condition: New
Part Number: P109290
Price: Kr17,900.30