Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-se
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent TriScroll Pumps On Sale Adixen 2021C2 Pumps On Sale Edwards nEXT300D TStations On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, No Inlet, Delivery Pressure Range 4-100 PSIG, SEQ3610ANI
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, Model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109530



Price: Kr45,417.34



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-296, Delivery Pressure Range 4-100 PSIG, SEQ3610A296
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-296 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-296 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, Model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109313



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-320, Delivery Pressure Range 4-100 PSIG, SEQ3610A320
In Stock
2


Matheson Series 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109314



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-326, Delivery Pressure Range 4-100 PSIG, SEQ3610A326
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109315



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-330, Delivery Pressure Range 4-100 PSIG, SEQ3610A330
In Stock
1


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-330 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P108566



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-346, Delivery Pressure Range 4-100 PSIG, SEQ3610A346
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-346 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109316



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-350, Delivery Pressure Range 4-100 PSIG, SEQ3610A350
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109317



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-510, Delivery Pressure Range 4-100 PSIG, SEQ3610A510
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109318



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-540, Delivery Pressure Range 4-100 PSIG, SEQ3610A540
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression port outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109319



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-580, Delivery Pressure Range 4-100 PSIG, SEQ3610A580
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109320



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-590, Delivery Pressure Range 4-100 PSIG, SEQ3610A590
In Stock
2


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109321



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-660, Delivery Pressure Range 4-100 PSIG, SEQ3610A660
Out of Stock


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-660 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P108326



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-705, Delivery Pressure Range 4-100 PSIG, SEQ3610A705
Out of Stock


Matheson Model 3610A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3610A, CGA-705 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-705 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 4-100 PSIG Delivery Pressure Gauge: Vac-0-200 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 3 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3610A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P108567



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, No Inlet, Delivery Pressure Range 2-30 PSIG, SEQ3613ANI
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613ANI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109531



Price: Kr44,041.04



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-296, Delivery Pressure Range 2-30 PSIG, SEQ3613A296
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-296 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-296 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109322



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-320, Delivery Pressure Range 2-30 PSIG, SEQ3613A320
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109323



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-326, Delivery Pressure Range 2-30 PSIG, SEQ3613A326
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109324



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-330, Delivery Pressure Range 2-30 PSIG, SEQ3613A330
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-330 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109325



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-346, Delivery Pressure Range 2-30 PSIG, SEQ3613A346
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-346 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109326



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-350, Delivery Pressure Range 2-30 PSIG, SEQ3613A350
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109327



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-510, Delivery Pressure Range 2-30 PSIG, SEQ3613A510
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-510 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-510 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109328



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-540, Delivery Pressure Range 2-30 PSIG, SEQ3613A540
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109329



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-580, Delivery Pressure Range 2-30 PSIG, SEQ3613A580
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109330



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-590, Delivery Pressure Range 2-30 PSIG, SEQ3613A590
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109331



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-660, Delivery Pressure Range 2-30 PSIG, SEQ3613A660
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-660 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109332



Price: Kr46,074.00



Currency: Swedish Krona (SEK)

Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm, CGA-705, Delivery Pressure Range 2-30 PSIG, SEQ3613A705
In Stock
1


Matheson Model 3613A Single Stage High Purity SS Regulator with Tied Diaphragm SEQ3613A, CGA-705 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-705 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 550 SCFH (320 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.09 Operating Temperature: -40°F to 160°F (-40°C to 71°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 2-30 PSIG Delivery Pressure Gauge: Vac-0-60 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 in compression tube outlet connection and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet diaphragm valve, metal to metal seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3610A, model 3613A regulator is to be used in applications requiring delivery pressures up to 100 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for specific applications requiring the supply of particular corrosive, toxic, or pyrophoric gases where a positive closure of the regulator is desired (eg. Semiconductor Manufacturing). Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109333



Price: Kr46,074.00



Currency: Swedish Krona (SEK)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com