Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-tu
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Adixen 2021C2 Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Agilent TriScroll Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Leybold IONIVAC ITR 90 Full Range Combination Pirani & Hot Cathode Ion Gauge 12091
Out of Stock
Expecting 3
Anticipated Arrival 1 on 2024-11-25


New Leybold IONIVAC ITR 90 Full Range Combination Pirani and Bayard-Alpert with KF-25 vacuum flange fitting Pirani & Hot Cathode Ionization Sensor. Leybold Part Number 12091. These Leybold IONIVAC ITR 90 gauges are a combination of Pirani and Bayard-Alpert (hot cathode ionization) sensors. They come with KF-25 vacuum flange fittings and have a single filament. They measure vacuum pressure from 750 to 3.8x10-10 Torr (1000 to 5×10-10 mbar). The Leybold IONIVAC ITR 90 is designed for vacuum measurement of non-flammable gases and has an output pressure signal that is logarithmic. These Leybold IONIVAC ITR-90 gauges can be operated in connection with the TURBOLAB 80 or with another evaluation unit. These items have Leybold part number 12 091. The manual and brochure is available for download below.

Condition: New



Part Number: P105195



Price: ₺96,185.41



Currency: Turkish Lira (TRY)

Leybold Replacement Cell KF-25 for IONIVAC ITR 90 Full Range Combination Cathode Ion Gauge
In Stock
5


Leybold Replacement Cell, for IONIVAC ITR 90 Full Range Combination Pirani & Hot Cathode Ion Gauge, KF25, NW25 flange.Part Number E12102. This is a replacement cell for the Leybold IONIVAC ITR 90 Full Range Combination Pirani & Hot Cathode Ion Gauge with KF25, NW25 flange.

Condition: New



Part Number: P107668



Price: ₺43,320.33




Currency: Turkish Lira (TRY)

Leybold Replacement Sensor KF-25 IE100 for ITR 100 Sensor Full Range Combination Cathode Ion Gauge E16361
Out of Stock


Leybold Replacement Sensor IE100, for ITR 100 Full Range Combination Pirani & Hot Cathode Ion Gauge, KF25, NW25 flange. Part Number E16361. This is a replacement Sensor for the Leybold ITR 100 Full Range Combination Pirani & Hot Cathode Ion Gauge with KF25, NW25 flange.

Condition: New



Part Number: P1011524



Price: ₺54,378.06



Currency: Turkish Lira (TRY)

Leybold Type C Cable Connects ITR 90 BA/Pirani Sensor to Turbolab 80 & Graphix 123 Controllers - 5 meter
In Stock
3


Leybold Cable Connects the ITR 90 BA/Pirani Sensor Gauge to TurboLab 80 Vacuum Pump Systems, ALSO connects to Graphix 123 Controllers, 16.5 ft. (5 meter) PN 12455 Leybold cable connects the ITR 90 BA/Pirani Sensor Gauge to TurboLab 80 vacuum pump systems and to the Leybold Graphix Pressure 123 Controllers. They are 16.5 foot long (5 meter) (this is the cable ONLY, ITR 90 BA/Pirani Sensor Gauge and TurboLab 80 vacuum pump system and Graphix Controllers sold separately.)

Condition: New



Part Number: P105426



Price: ₺10,426.06




Currency: Turkish Lira (TRY)

Leybold IONIVAC ITR 90 Gauge Kit For TURBOLAB 80 Pumping System with ISO63 Inlet to KF25
Out of Stock
Anticipated Arrival 1 on 2024-12-25


Brand NEW IONIVAC ITR 90 Kit For Leybold TURBOLAB 80 Pumping System with CF ISO 63 Inlet to KF25, These ITR 90 gauge kits (with IONIVAC ITR 90 Pirani with a Bayard-Alpert -Hot Cathode Ionization- Sensor Gauge) are designed to work with Leybold TURBOLAB 80 System. The functions of the Leybold IONIVAC ITR 90 gauge with a Bayard Alpert hot cathode ionization measurement system (for p < 2.0×10-2 mbar) and a Pirani measurement system (for p > 5.5×10-3 mbar) pressure range 750 Torr to 3.8x10-10 Torr. In the overlapping pressure range of 2.0×10-2 … 5.5×10-3 mbar a mixed signal of the two measurement systems is output. The hot cathode is switched on by the Pirani measurement system only below the switching threshold of 2.4×10-2 mbar (to prevent filament burn-out). It is switched off when the pressure exceeds 3.2×10-2 mbar. The Hot Ion Combi Gauges ITR 90 has been designed for vacuum measurement of non-flammable gases and gas mixtures in a pressure range 750 Torr to 3.8x10-10 Torr (5×10-10 … 1000 mbar), comes with KF25 vacuum flange fitting. The gauge can be operated in connection with the TURBOLAB 80 or with another evaluation unit. This is a GAUGE KIT ONLY, individual parts or systems sold separately. Gauge Kit includes all the parts listed below.

Condition: New



Part Number: P105242



Price: ₺124,717.26



Currency: Turkish Lira (TRY)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com