Skip to main content
× Página Inicial Servicios Productos Catálogos Descargas Asistencia Técnica Acerca de Contacto Carreras (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Carrito
 
Login Icon
Iniciar sesión
Language Selector
es-es
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent Varian Helium Leak Detectors On Sale Edwards nXR Multi Stage Roots Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Agilent TriScroll Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale

Palabra Clave       Número de Parte:      

× Bombas de vacío Cámaras de vacío modulares Cámaras de vacío de acero inoxidable Cámaras de aluminio soldadas ideales ExploraVAC Cámaras Ilimitadas ExploraVAC Cámaras de Vacío Accesorios y bridas Pasamuros Válvulas de vacío Kits de reconstrucción, piezas y motores Líquidos, aceites y grasas para vacío Turbobombas y controladores Filtros Trampas y Silenciadores Hornos de convección y vacío Detección de fugas y RGA Medición de presión de vacío Refrigeradores de recirculación y baños de agua
×

Load

Product Image 1
Product Image 2
Product Image 3

Reemplazo de tapa fría estándar Agilent Varian HS-16, piezas de bomba de vacío de difusión, 79299301

Condición:
  Nuevo
Número de parte:
  P106992
Garantía:
  Varian Warranty

Agotado   

Venta: €1,671.63

Reemplazo de tapa fría estándar Agilent Varian HS-16, piezas de bomba de vacío de difusión, 79299301 1671.63
Divisa: Euro (Euro)

Descripción

Tapa fría estándar de repuesto para bomba de difusión Agilent Varian HS-16.
Agilent Varian PN 84358301.

Estas tapas frías estándar de la bomba de difusión Agilent Varian HS-16 son una pieza de repuesto que se puede instalar en las instalaciones del cliente. Hay dos tipos de tapas frías, estándar y Halo Baffle. El tipo de tapa fría que se utilice influirá en factores como el reflujo de aceite y la velocidad de bombeo final de la bomba de difusión. Por ejemplo, la tapa fría con deflector Halo es una opción que encaja dentro de las bombas HS-16 en lugar de la tapa fría estándar. El deflector Halo detiene el flujo inverso con la misma eficacia que un deflector ópticamente denso, pero conserva el 60 % de la velocidad de la bomba. El reflujo residual es tan bajo que no se puede medir con el método de recolección estándar de la American Vacuum Society. Para conocer la ubicación de la tapa fría, consulte el elemento n.° 1 en la vista de despiece del diagrama y la ilustración de las piezas que se muestra a continuación. Para conocer los procedimientos de instalación de extracción de la tapa fría, consulte la página 38 del manual de instrucciones en PDF a continuación. Estas tapas frías estándar son piezas de repuesto originales OEM Agilent Varian con número de pieza 79299301.

Folleto

ITEM DESCRIPTION PART NO.
1 Standard Cold Cap Assembly - Includes 10-32 SST Rd Hd screw & 10-32 SST Hex nut 79299301
1 Water-Cooled Halo Baffle K0143316
2 Cold Cap Water Connection:
Cold Cap Gasket/Grommet (Kit of 4)L8839301
Cold Cap Nut & Followers KitL8840301
3 Jet Assembly 83612401
4 Jet Coupling L6367301
5 Foreline Baffle Assembly 80798301
6 Sight Glass Service Kit for Pumps Built Before 1995:
3 Glass TubesF1755008
2 Brass Union 1/4 OD x 1/4 MPT622568108
2 Brass Elbow 69FL 6x4, 169VL6-4623451012
8 O-ring, Viton, Parker No. 2-011660892011
8 O-ring, Viton, Parker No. 2-111660892111
3 O-ring, Viton, Parker No. 2-221660892221
3 O-ring, Viton, Parker No. 2-213660892213
F6097301
6 Sight Glass Service Kit for Pumps Built After 1995 K8475001
7 Threaded Plug, Fill & Drain 77261001
8 Upper Thermal Switch, Temperature Setting 185°C K9050001
9 Lower Thermal Switch, Temperature Setting 390°C K9050002
10 Heater Nickel Wire 80 Inches, 14 AWG (2 per heater required) X3900-68006
10 Dalton Heater Wire 120 inches, 10 AWG (2 per heater required) X3900-68000
10b Heater Wiring Connection Box
Nickel Lug for No. 14 AWG 648056329
11 Heaters (Thtee heaters required per pump)
200 V / 2700 watt Heater Element With Leads647316025
200 V / 3200 watt Heater Element With Leads647316027
240 V or 415 V / 2700 watt Heater Element With Leads647316020
240 V or 415 V / 3200 watt Heater Element With Leads647316023
400 V / 2700 watt Heater Element With Leads647316037
400 V / 3200 watt Heater Element With Leads647316038
430 V / 2700 watt Heater Element With Leads647316039
430 V / 3200 watt Heater Element With Leads647316040
440 V / 2700 watt Heater Element With Leads647316041
440 V / 3200 watt Heater Element With Leads647316042
480 V / 2700 watt Heater Element With Leads647316030
480 V / 3200 watt Heater Element With Leads647316033
240 V or 415 V / 2700 watt Heater Element No Leads.
Used on Pumps Built Before May 1990
647316035
480 V / 2700 watt Heater Element No Leads.
Used on Pumps Built Before May 1990
647316045
12 Heater Crush Plate, required with heater replacement K4919001
13 Heater Clamping Plate K4917001
14 Heater Insulation Blanket 79309001
15 Heater Cover Plate 79308001
O-Ring Kit includes:
1 Butyl O-ring for ASA Inlet Flange48214001
1 O-ring for Foreline Flange Buna Parker 2-348660890348
8 Fill and Drain O-rings, Viton Parker 2-213660892213
4 O-rings, Viton Parker 2-221660892221
1 Sight Glass O-ring Viton 2-232660892232
1 Graphite Sight glass GasketK8478001
K0377164
16 Butly Centering Ring for ASA Inlet Flange 48214001
17 Centering Ring for ASA Foreline Flange 660890348
17 Centering Ring for ISO Foreline Flange, 100K IC100SV
Included with ASA pumps:
16 One O-ring for ASA Inlet Flange84349002
17 One O-ring for ASA Foreline Flange 660893432
Installation and Operation Manual699901140
DC-702 diffusion pump fluid, one gallon 695472008
DC-704 diffusion pump fluid, one gallon 695474008
DC-705 diffusion pump fluid, one gallon 695475008