Skip to main content
× Página Inicial Servicios Productos Catálogos Descargas Asistencia Técnica Acerca de Contacto Carreras (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Carrito
 
Login Icon
Iniciar sesión
Language Selector
es-pr
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Edwards nXR Multi Stage Roots Pumps On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Edwards nEXT300D TStations On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale

Palabra Clave       Número de Parte:      

× Bombas de vacío Cámaras de vacío modulares Cámaras de vacío de acero inoxidable Cámaras de aluminio soldadas ideales ExploraVAC Cámaras Ilimitadas ExploraVAC Cámaras de Vacío Accesorios y bridas Pasamuros Válvulas de vacío Kits de reconstrucción, piezas y motores Líquidos, aceites y grasas para vacío Turbobombas y controladores Filtros Trampas y Silenciadores Hornos de convección y vacío Detección de fugas y RGA Medición de presión de vacío Refrigeradores de recirculación y baños de agua
×

Load

Product Image 1
Product Image 2
Product Image 3

Refletor Agilent Varian para bomba de difusión HS-2. PN 82917301

Condición:
  Nuevo
Número de parte:
  P106763
Garantía:
  Varian Warranty

Disponible Ahora:   1  

Venta: $618.14

Refletor Agilent Varian para bomba de difusión HS-2. PN 82917301 618.14
Divisa: US Dollar (USD)

Descripción

Bomba de difusión Agilent Varian HS-2, reflector
Número de pieza Agilent Varian 82917301

Este es un reflector de reemplazo. Se adapta a la bomba de difusión Agilent Varian HS-2.

Folleto

Specifications
Specification Value
Optimum Operating Range 2x10⁻³ Torr (2.7 mbar) to < 5x10⁻⁸ Torr (6.7 mbar)
Maximum Pumping Speed 285 l/s, Air
Maximum Throughput (Air), Max. 0.5 Torr l/s (.67 mbar)
Maximum Forepressure No Load 5.5 x 1010⁻± (.73 mbar)
Full Load 4.0 x 1010⁻± (.53 mbar)
Backstreaming Rate at Pump Inlet 1x10⁻³ mg/cm2/min (with cold cap)
Power Requiered (Approximately) 450 Watts
Warmup Time 15 minutes
Cooldown Time Less than 5 minutes to break jet
Less than 10 minutes to vent pump
Fluid Charge 100 cc All conventional and high performance pump fluids
Cooling Water Requirements 0.1 gpm at 60° °F
(15.6 ° °C to 26.7 ° °C) Inlet temperature
Backing Pump Size 5 cfm or larger for optimum throughput

HS-2 Diffusion Pump Replacement Parts List

Description Part No. Item
Heaters (one heater required per pump) 1
   120 V / 450 watt Heater Assembly 647302125 5.1
   240 V / 450 watt Heater Assembly 647302150 5.1
Heater Block 82920001 2
Heater Platen 82918301 3
Jet Assembly F0310301 4
Top Cap 5
Cold Cap Assembly F0600301 6
Teflon Button F0597001 7
Butly O-ring Kit, Parker 2-238 for 2in DP K0377159 8
Foreline Baffle 84166301 9
Baffle Retaining Ring 660156010 10
Heater Clip 648018010 11
2-56 x 1/8 R.H.M.S. SS Standard 12
#4-40 x 3/16 Rd. Hd. MS Ni-Plated Standard 13
10-32 Hex Hd. SS 648018010 14
1/4 - 20 x 13/8, Hex. Hd. Cap Screw/Lock Washer SS Standard 15
Reflector 82917301 16
Santovac 5 diffusion pump fluid, 100 cc P102288
Marca de agua con el logotipo de Ideal Vacuum
CONTÁCTENOS
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, Nuevo México 87109-5805 USA

Teléfono: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 0.6934