Skip to main content
× Maison Prestations de service Des produits Catalogues Téléchargements Support technique À propos Contact Carrières (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Chariot
 
Login Icon
Se connecter
Language Selector
fr-be
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Agilent TriScroll Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Adixen 2021C2 Pumps On Sale

Mot-clé       Numéro d'article:      

× Les pompes à vide Chambres à vide modulaires Chambres à vide en acier inoxydable Chambres à vide en aluminium ExploraVAC Illimité Chambres Chambres à vide ExploraVAC Raccords et Brides Traversées Vannes à vide Reconstruire Kits, Pièces, Et Moteurs Vide Fluides, Huiles, et Graisses Turbo pompes et contrôleurs Filtres Pièges et Silencieux Fours à convection et à vide Détection de fuite et RGA Mesure de vide pression Refroidisseurs a recirculation et bains marie
×

Load

Product Image 1
Product Image 2
Product Image 3

Interrupteur thermique supérieur Agilent Varian HS-20 HS16, pièces de rechange pour pompe à vide à diffusion, PN K9050001

Condition:
  Nouveau
Numéro d'article:
  P107084
Garantie:
  Varian Warranty

Disponible dès maintenant   9  

Vente: €213.73

Interrupteur thermique supérieur Agilent Varian HS-20 HS16, pièces de rechange pour pompe à vide à diffusion, PN K9050001 213.73
Devise: Euro (Euro)

Description

Interrupteur thermique supérieur Agilent Varian HS-20 et HS16, pièces de rechange pour pompe à vide à diffusion
Référence Agilent Varian PN K9050001

Il s'agit d'un interrupteur thermique supérieur (eau) de remplacement. Convient à la pompe à diffusion Agilent Varian HS-20/16. Réglez à 185º F, 85º C. Pour l'emplacement de l'interrupteur thermique supérieur, voir la figure 8 (diagramme éclaté et illustration des pièces) ci-dessous.

Brochure

ITEM DESCRIPTION PART NO.
1 Standard Cold Cap Assembly - Includes 10-32 SST Rd Hd screw & 10-32 SST Hex nut 84358301
1 Water-Cooled Halo Baffle K1855320
2 Cold Cap Water Connection:
Cold Cap Gasket/Grommet (Kit of 4)L8839301
Cold Cap Nut & Followers KitL8840301
3 Jet Assembly 84350301
4 Jet Coupling L6367301
5 Foreline Baffle Assembly 84889301
6 Sight Glass Service Kit for Pumps Built Before 1995:
3 Glass TubesF1755008
2 Brass Union 1/4 OD x 1/4 MPT622568108
2 Brass Elbow 69FL 6x4, 169VL6-4623451012
8 O-ring, Viton, Parker No. 2-011660892011
8 O-ring, Viton, Parker No. 2-111660892111
3 O-ring, Viton, Parker No. 2-221660892221
3 O-ring, Viton, Parker No. 2-213660892213
F6097301
6 Sight Glass Service Kit for Pumps Built After 1995 L9223001
6 Sight Glass Assembly for Pumps Built Before 1995:
Seal Valve
Glass Tube
Removable Bracket
Cover for Sight Glass Assembly
Fittings
F1755301
7 Threaded Plug, Fill & Drain 77261001
8 Upper Thermal Switch, Temperature Setting 185°F K9050001
9 Lower Thermal Switch, Temperature Setting 390°F K9050002
10 Heater Nickel Wire 80 Inches, 14 AWG (2 per heater required) X3900-68006
10 Dalton Heater Wire 120 inches, 10 AWG (2 per heater required) X3900-68000
10b Heater Wiring Connection Box
Nickel Lug for No. 14 AWG 648056329
11 Heaters (six heaters required per pump)
200 V / 2000 watt Heater Element With Leads647320025
240 V or 415V / 2000 watt Heater Element With Leads647320020
240 V or 415V / 2000 watt Heater Element No Leads for pumps
built before May '90
647320060
400 V / 2000 watt Heater Element With Leads647320035
430 V / 2000 watt Heater Element With Leads647320040
440 V / 2000 watt Heater Element With Leads647320045
480 V / 2000 watt Heater Element With Leads647320030
480 V / 2000 watt Heater Element No Leads for pumps built
before May '90
647320070
12 Heater Crush Plate, replace with each heater K7108001
13 Heater Clamping Plate K7107001
14 Heaters Insulation, Cerablanket 0.50" Thick L6514001
15 Heater Cover Plate 84497001
O-Ring Kit includes:
1 Butyl O-ring for ASA Inlet Flange84349002
1 O-ring for Foreline Flange660893432
8 Fill and Drain O-rings, Viton Parker 2-213660892213
4 O-rings, Viton Parker 2-221660892221
1 Sight Glass O-ring660892240
1 Graphite Sight glass GasketL9228001
K0377165
16 Butly Centering Ring for ASA Inlet Flange 84349002
17 Centering Ring for ASA Foreline Flange 660893432
17 Centering Ring for ISO Foreline Flange, 160K IC160SV
Included with ASA pumps:
16 One O-ring for ASA Inlet Flange84349002
17 One O-ring for ASA Foreline Flange 660893432
18 Two Water Coupling for Cold Cap622445026
Two 1/2" Hose 3/8 Pipe Barbed Connectors624301111
Four 3/8" Hose 3/8 Pipe Barbed Connectors624301110
Installation and Operation Manual699901140
DC-702 diffusion pump fluid, one gallon 695472008
DC-704 diffusion pump fluid, one gallon 695474008
DC-705 diffusion pump fluid, one gallon 695475008
Marca de agua con el logotipo de Ideal Vacuum