Skip to main content
× Casa Servizi Prodotti Cataloghi Download Supporto tecnico Di Contatto Carriere (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Carrello
 
Login Icon
Login
Language Selector
it-it
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent TriScroll Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale Adixen 2021C2 Pumps On Sale Edwards nEXT300D TStations On Sale Agilent Varian Helium Leak Detectors On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale

Parola chiave       Numero di parte:      

× Pompe per vuoto Camere sottovuoto modulari Camere a vuoto in acciaio inossidabile Camere a vuoto in alluminio ExploraVAC Unlimited Chambers ExploraVAC Camere a vuoto Raccordi e Flange Passaggi Valvole per vuoto Kit di ricostruzione, parti e motori Fluidi per vuoto, oli e grassi Turbopompe e controller Filtri Trappole e Silenziatori Forni a convezione e sottovuoto Rilevamento perdite e RGA Misurazione della pressione del vuoto Refrigeratori e bagni d'acqua a ricircolo
×

Load

Product Image 1
Product Image 2
Product Image 3

Riscaldatore per pompa a diffusione Agilent Varian VHS10 VHS400 240 V CA, 2200 W, 9,2 A, 26 Ohm, 1 cad., 647310150

Condizione:
  Nuovo
Numero di parte:
  P103147
Garanzia:
  Contro il difetto del prodotto

Disponibile ora   4  

Vendita: €423.04

Riscaldatore per pompa a diffusione Agilent Varian VHS10 VHS400 240 V CA, 2200 W, 9,2 A, 26 Ohm, 1 cad., 647310150 423.04
Valuta: Euro (Euro)

Descrizione

Riscaldatore tubolare con pompa a diffusione Agilent Varian VHS10 VHS400 240 V CA, 2200 W, 9,2 A, 26 Ohm, per riscaldatore,
PN 647310150 (venduti singolarmente)

Questi riscaldatori sostitutivi di tipo tubolare con pompa da vuoto a diffusione Agilent Varian VHS-10 e VHS-400 sono destinati all'uso con alimentazione in ingresso da 240 V CA. Questi riscaldatori assorbono 2200 Watt, 9,2 Amp e hanno una resistenza alla temperatura ambiente di 26 Ohm. Questi riscaldatori sono progettati per funzionare a 240 VAC, per i quali sono necessari due riscaldatori (4400 Watt di potenza di riscaldamento). Per le istruzioni sulla sostituzione del gruppo riscaldatore, vedere pagina 43 nel manuale di istruzioni in formato .pdf di seguito. Il numero di parte Agilent Varian per questo riscaldatore è 647310150. Altri accessori per pompe a diffusione sono disponibili su questo sito web.

Opuscolo

ITEM DESCRIPTION PART NO.
1 Standard Cold Cap Assembly F0429301
2 Extended Cold Cap Assembly L8917301
3 Sight Glass Repair Kit consisting of:
Sight GlassL8816001
Gasket, TeflonL9694001
O-ring, Viton, Parker No. 2-113ComI
O-ring, Viton, Parker No. 2-226ComI
L8908301
4 Jet Assembly F0428401
5 Jet Coupling L6367301
6 Splash Baffle F0431301
7 Foreline Baffle Assembly F0435301
8 Thermal Switch Includes:
8a - Switch (set at 300°F – 147°C)642906025
8b - Lug648056680
8c - Wire656179100
8d - Box Insulator89867001
L8912301
9 Heater wire, 10 AWG, 42 inches (3 per pump required) X3901-68003
Heater Wiring Kit, Includes:
15 ft. wire
Nickel lug648056680
Terminal Strip Molex 39100-1512648091065
L8913301
10 Heaters (two heaters required per pump)
208 V / 2200 watt Heater Element647310140
240 V / 2200 watt Heater Element, 1Ph647310150
380 V / 2200 watt Heater Element647310160
480 V / 2200 watt Heater Element, wired open Delta, unbalanced load647310170
208 V / 2550 watt Heater Element647310145
240 V / 2550 watt Heater Element, 1Ph647310155
380 V / 2550 watt Heater Element, wired open Delta, unbalanced load647310165
480 V / 2550 watt Heater Element, wired open Delta, unbalanced load647310175
11 Heater Crush Plate (replace when either heater is replaced) K7667001
12 Heater Clamping Plate A36 Steel K4928001
12 Heater Clamping Plate Retrofit, Slotted R2667301
13 Heater Insulating Blanket L8914001
14 Heater Cover L8903301
15 O-Ring Kit includes:
  • 1 inlet flange O-ring, Butyl No. 2-385
  • F0430001
  • 1 foreline flange O-ring, Butyl No. 2-338
  • 660893338
  • 10 Viton fill and drain O-rings (old style), Viton No. 2-112
  • 10 Viton fill and drain O-rings (new style, Viton No. 2-113
  • 1 Sight glass O-ring, Parker No. 2-226
  • 1 PTFE gasket
  • K0377169
    16 Viton Centering ring for ISO inlet flange, 320K
    17 Centering ring for ISO foreline flange ISO-63K IC063SV
    Included with the pump
    1 inlet flange O-ring, Butyl No. 2-385F0430001
    1 Butyl foreline flange O-ring, Butyl No. 2-338660893338
    3/8 Hose 1/8 Pipe Barbed Connectors264301102
    Installation and Operation Manual-download from www.agilent.com/chem/vacuum699901023
    DC-702 diffusion pump fluid, 500 cc (2 required) 695472005
    DC-704 diffusion pump fluid, 500 cc (2 required) 695474005
    DC-705 diffusion pump fluid, 500 cc (2 required) 695475005

    Kit Components

    Availability Of Kit Components 2

    Kit: P103147 - Riscaldatore per pompa a diffusione Agilent Varian VHS10 VHS400 240 V CA, 2200 W, 9,2 A, 26 Ohm, 1 cad., 647310150
    Component
    Desc.
    Req'd
    Avail
    Non-Standard
    No Component Description Available On Website
    1
    4
    Marca de agua con el logotipo de Ideal Vacuum
    CONTATTACI
    Ideal Vacuum Products , LLC
    5910 Midway Park Blvd NE
    Albuquerque, Nuovo Messico 87109-5805 USA

    Telefono: (505) 872-0037
    Fax: (505) 872-9001
    info@idealvac.com



    Press ESC to Close


    deepbox image 2
    load time = 2.9297