× Bombas de vácuo Câmaras de vácuo modulares Câmaras de vácuo em aço inoxidável Câmaras de vácuo de alumínio ExploraVAC Câmaras Ilimitadas ExploraVAC Câmaras de Vácuo Conexões e Flanges Passatempos Válvulas de Vácuo Kits de reconstrução, peças e motores Vácuo Fluidos, Óleos e Graxas Turbobombas e controladores Filtros armadilhas e silenciadores Fornos de Convecção e Vácuo Detecção de vazamento e RGA Vácuo Pressão Medição Resfriadores e Banhos de Água Recirculantes
×

Load

Product Image 1
Product Image 2
Product Image 3

Substituição da tampa fria estendida Agilent Varian VHS-10, peças da bomba de vácuo de difusão, L8917301

Doença:
  Novo
Número da peça:
  P107095
Garantia:
  Full Manufacturer's Warranty

Disponível agora   3  

Oferta: R$9,378.02

Substituição da tampa fria estendida Agilent Varian VHS-10, peças da bomba de vácuo de difusão, L8917301 9378.02
Moeda: Brazilian Real (BRL)

Descrição

Tampa fria estendida Agilent Varian VHS-10, chapéu mexicano, peças de reposição de bomba de vácuo de difusão
Número de peça Agilent Varian L8917301

Essas tampas frias estendidas Agilent Varian VHS-10 são peças de reposição OEM Agilent Varian para as bombas de vácuo de difusão VHS-10. O gorro frio estendido às vezes é chamado de "chapéu mexicano" devido ao seu formato. Existem dois tipos de cold caps, padrão e estendido. O tipo de cold cap utilizado influenciará fatores como refluxo de óleo e velocidade final de bombeamento da bomba de difusão. Por exemplo, a tampa fria estendida é uma opção que cabe dentro das bombas VHS-4, VHS-6 e VHS-10 no lugar da tampa fria padrão. Ele interrompe o refluxo com a mesma eficiência de um defletor opticamente denso, mas retém 80% da velocidade da bomba. O backstreaming residual é tão baixo que não pode ser medido pelo método de coleta padrão da American Vacuum Society. Para obter os procedimentos de remoção e instalação da tampa fria, consulte a página 41 do manual de instruções PDF abaixo. Essas tampas frias estendidas são peças de reposição originais OEM Agilent Varian com número de peça L8917301, consulte o item 2 em (diagrama de exibição explodida e ilustração de peças) abaixo.

Folheto

Specifications
Specification Value
Pumping Speed, Operating Range 3,650 l/s air, 4,560 l/s He/H₂
Maximum Pumping Speed 5,300 l/s air w/standard cold cap; 4,200 w/extended cold cap
Maximum Throughput 6.3 T-l/s (8.4 mbar-l/s) in operating range, 7.5 T-l/s (10.0 mbar-l/s) @ 0.01 Torr
Operating Range 1.7x10⁻³ to < 5x10⁻⁹ Torr at 4,400 W. (2.3 x 10⁻³ to < 6.5 x 10⁻⁹ mbar)
Maximum Forepressure No Load: 0.65 Torr (0.85 mbar)
Full Load: 0.55 Torr (0.72 mbar)
Recommended Backing Pump ≥ 30 cfm (51 m³/hr)
Backstreaming Rate < 5x10⁻⁴ mg/cm²/min (with standard cold cap)
Warmup Time 15 minutes
Cooldown Time 25 minutes (with quick cool coil)
Fluid Charge 1,000 cc
Electrical Requirements 3 ph, 50/60 Hz, 208/240/380/480 VAC
Pump Power 4,400 Watts
Cooling Water Requirements 0.40 gpm (80 l/h)
Water Connections ⅛ in. FPT Tee

VHS-10 Diffusion Pump Replacement Parts List

Description Part No. Item
Standard Cold Cap Assembly F0429301 1
Extended Cold Cap Assembly L8917301 2
Sight Glass Repair Kit consisting of: L8908301 3
   Sight Glass L8816001 5.1
   Gasket, Teflon L9694001 5.1
   O-ring, Viton, Parker No. 2-113 CommI 5.1
   O-ring, Viton, Parker No. 2-226 CommI 5.1
Jet Assembly F0428401 4
Jet Coupling L6367301 5
Splash Baffle F0431301 6
Foreline Baffle Assembly F0435301 7
Thermal Switch Includes: L8912301 8
   Switch (set at 300 °F – 147 °C) 642906025 8a
   Lug 648056680 8b
   Wire 656179100 8c
   Box Insulator 89867001 8d
Heater wire, 10 AWG, 42 inches (3 per pump required) X3901-68003 9
Heater Wiring Kit, Includes: L8913301 9
   15 ft. wire L8913301 5.1
   Nickel lug 648056680 5.1
   Terminal Strip Molex 39100-1512 648091065 5.1
Heaters (two heaters required per pump) 10
   208 V / 2200 watt Heater Element 647310140 5.1
   240 V / 2200 watt Heater Element, 1Ph 647310150 5.1
   380 V / 2200 watt Heater Element 647310160 5.1
480 V / 2200 watt Heater Element, wired open Delta, unbalanced load 647310170 5.1
   208 V / 2550 watt Heater Element 647310145 5.1
   240 V / 2550 watt Heater Element, 1Ph 647310155 5.1
   380 V / 2550 watt Heater Element, wired open Delta, unbalanced load 647310165 5.1
480 V / 2550 watt Heater Element, wired open Delta, unbalanced load 647310175 5.1
Heater Crush Plate (replace when either heater is replaced) K7667001 11
Heater Clamping Plate A36 Steel K4928001 12
Heater Clamping Plate Retrofit, Slotted R2667301 12
Heater Insulation Blanket L8914001 13
Heater Cover L8903301 14
O-Ring Kit includes: K0377185 15
   1 inlet flange O-ring, Butyl No. 2-385 F0430001
   1 foreline flange O-ring, Butyl No. 2-338 660893338
   10 Viton fill and drain O-rings (Old style), Viton No. 2-112 5.1
   10 Viton fill and drain O-rings (new style, Parker No. 2-113 5.1
   1 Sight glass O-ring, Parker No. 2-226 5.1
   1 PTFE gasket 5.1
Viton Centering ring for ISO inlet flange, 320K 16
Centering ring for ISO foreline flange ISO-63K IC063SV 17
Screw, Socket hd cap, no. 8-32x11/44, stainless steel Screw 18
Centering ring for ISO inlet flange, 160K IC160SV 19
Centering ring for ISO foreline flange, KF40 KC40SV 20
Included with the pump: 5.1
   1 inlet flange O-ring, Butyl No. 2-385 F0430001 5.1
   1 Butyl foreline flange O-ring, Butyl No. 2-338 660893338 5.1
   13/8 Hose 1/8 Pipe Barbed Connectors 264301102 5.1
5.1
DC-702 diffusion pump fluid, 500 cc (2 required) 695472005
DC-704 diffusion pump fluid, 500 cc (2 required) 695474005
DC-705 diffusion pump fluid, 500 cc (2 required) 695475005
Installation and Operation Manual 699901021