Skip to main content
× Lar Serviços Produtos Catálogos Transferências Suporte técnico Sobre Contato Carreiras (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Carrinho
 
Login Icon
Conecte-se
Language Selector
pt-pt
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Edwards nXR Multi Stage Roots Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent TriScroll Pumps On Sale

Palavra-chave       Número da peça:      

× Bombas de vácuo Câmaras de vácuo modulares Câmaras de vácuo em aço inoxidável Câmaras de vácuo de alumínio ExploraVAC Câmaras Ilimitadas ExploraVAC Câmaras de Vácuo Conexões e Flanges Passatempos Válvulas de Vácuo Kits de reconstrução, peças e motores Vácuo Fluidos, Óleos e Graxas Turbobombas e controladores Filtros armadilhas e silenciadores Fornos de Convecção e Vácuo Detecção de vazamento e RGA Vácuo Pressão Medição Resfriadores e Banhos de Água Recirculantes
×

Load

Product Image 1
Product Image 2
Product Image 3

Substituição da tampa fria padrão Agilent Varian VHS-6 e VHS-4, peças da bomba de vácuo de difusão, 86488301

Doença:
  Novo
Número da peça:
  P106803
Garantia:
  Full Manufacturer's Warranty

Disponível agora   9  

Oferta: €710.71

Substituição da tampa fria padrão Agilent Varian VHS-6 e VHS-4, peças da bomba de vácuo de difusão, 86488301 710.71
Moeda: Euro (Euro)

Descrição

Substituição da bomba de difusão Agilent Varian VHS-6 e VHS-4 Standard Cold Cap.
Agilent Varian PN 86488301

Essas tampas frias padrão da bomba de difusão Agilent Varian VHS-6 e VHS-4 são uma peça de reposição que pode ser instalada no local do cliente. Existem dois tipos de cold caps, padrão e estendido. O tipo de cold cap utilizado influenciará fatores como refluxo de óleo e velocidade final de bombeamento da bomba de difusão. Por exemplo, a tampa fria estendida é uma opção que cabe dentro das bombas VHS-4, VHS-6 e VHS-10 no lugar da tampa fria padrão. Ele interrompe o refluxo com a mesma eficiência de um defletor opticamente denso, mas retém 80% da velocidade da bomba. O backstreaming residual é tão baixo que não pode ser medido pelo método de coleta padrão da American Vacuum Society. Para a localização da tampa fria, consulte o item nº 1 na vista explodida do diagrama e na ilustração das peças mostrada abaixo. Para obter os procedimentos de remoção e instalação da tampa fria, consulte a página 37 do manual de instruções PDF abaixo. Essas tampas frias padrão são peças de reposição originais OEM Agilent Varian com número de peça 86488301.

Folheto

Specifications
Specification Value
Pumping Speed, Operating Range 1500 l/s air, 1,930 l/s He/H₂
Maximum Pumping Speed 2,400 l/s air w/standard cold cap; 950 w/extended cold cap
Maximum Throughput 2.4 T-l/s (3.2 mbar-l/s) in operating range, 3.5 T-l/s (4.5 mbar-l/s) @ 0.01 Torr
Operating Range 1.5x10⁻³ to < 5x10⁻⁹ Torr (2.10 x 10⁻³ < 6.5 x 10⁻⁹ mbar)
Maximum Forepressure No Load: 0.65 Torr (0.85 mbar)
Full Load: 0.55 Torr (0.72 mbar)
Recommended Backing Pump ≥ 17 cfm (29 m³/hr)
Backstreaming Rate < 5x10⁻⁴ mg/cm²/min (with standard cold cap)
Warmup Time 10 minutes
Cooldown Time 10 minutes (with quick cool coil)
Fluid Charge 500 cc - exact fluid charge available
Electrical Requirements 1 ph, 50/60 Hz, 120/208/240 VAC
Pump Power 2,200 Watts
Cooling Water Requirements 0.25 gpm (50 l/h) at 60-80 °F (15-26 °C)
Water Connections ⅛ in. FPT Tee

VHS-6 Diffusion Pump Replacement Parts List

Description Part No. Item
Standard Cold Cap Assembly 86488301 1
Extended Cold Cap Assembly F6455001 2
Sight Glass Repair Kit consisting of: L8908301 3
   Sight Glass L8816001 5.1
   Gasket, Teflon L9694001 5.1
   O-ring, Viton, Parker No. 2-113 CommI 5.1
   O-ring, Viton, Parker No. 2-226 CommI 5.1
Jet Assembly F3365301 4
Splash Baffle F4780301 5
Foreline Baffle Assembly L9172301 6
Thermal Switch Includes: L8912301 7
   Switch (set at 300 °F – 147 °C) 642906025 7a
   Lug 648056680 7b
   Wire 656179100 5.1
   Box Insulator 89867001 7d
Heaters (one heater required per pump) 8
   120 V / 2200 watt Heater Element 647306125 5.1
   208 V / 2200 watt Heater Element 647306175 5.1
   240 V / 2200 watt Heater Assembly 647306225 5.1
VHS-4 heater wire, 10 AWG, 24 inches (3 per pump required) X3901-68001 9
Lugs, Replacement, nickel 648056680 10
Heater Clamping Plate 86086301 11
Heater Insulation 86087001 12
Baffle Retaining Ring 699992156 13
O-Ring Kit includes: K0377184 14
   3 Butyl inlet flange O-ring, Parker No. 2-258 5.1
   10 Viton fill and drain O-rings (old style), Parker No. 2-112 5.1
   10 Viton fill and drain O-rings (new style, Parker No. 2-113 5.1
   1 Sight glass O-ring, Parker No. 2-226 5.1
   1 PTFE gasket 5.1
Screw, Rd hd machine, no. 8-32x31/416, stainless steel Screw 15
Stud, no. 8-32 x 1/2, stainless steel Stud 16
Screw, Socket hd cap, no. 8-32x11/44, stainless steel Screw 17
Centering ring for ISO inlet flange, 160K IC160SV 18
Centering ring for ISO foreline flange, KF40 KC40SV 19
Santovac 5 diffusion pump fluid, 500 cc 695405005
Installation and Operation Manual 699901021

Kit Components

Availability Of Kit Components 2

Kit: P106803 - Substituição da tampa fria padrão Agilent Varian VHS-6 e VHS-4, peças da bomba de vácuo de difusão, 86488301
Component
Desc.
Req'd
Avail
Non-Standard
No Component Description Available On Website
1
9
Marca de agua con el logotipo de Ideal Vacuum
CONTATE-NOS
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, Novo México 87109-5805 USA

Telefone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 5.6719