× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
The Agilent PHD-4 is a portable, compact leak detector that runs on its own battery for up to four hours. Weighing only 2.6 kg (5.7 lbs) including the battery, it can be taken anywhere. The PHD-4 detects very small leaks in objects that have a slight helium/air pressure inside. It is sensitive to helium concentrations as small as 2 parts per million which equivalent to a leak rate of 5 x 10-6 atm-cc/sec. This level of sensitivity is far superior to the performance of other means of detecting leaks such as bubble testing. To accomplish this it relies on Agilent Varian?s proprietary and patented Selective Ion Pump Detection (SIPD) technology. Controlled by a microprocessor, the PHD-4 is easy to use with no training required. All tuning and zeroing are handled automatically. The display can be set to use any of four languages; English, French, German, and Italian.

Helium Leak Testing Basics
Helium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.

At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a "leak," is identified by a rise in the level of helium being analyzed by the machine.

Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.

While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user?s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection, make sure your "pilot" knows how to fly.

Why Is Helium Superior?
While many gases are used in leak detection, heliums qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas.

More information about these
612.4701
Agilent Varian HELITEST HAND HELD PROBE 10 M., Helium-Leak-Detectors, Helium Leak Detectors,  PN  9693525
×

Load

Description

  
Agilent Varian HELITEST HAND HELD PROBE 10 M., Helium-Leak-Detectors, Helium Leak Detectors,  PN  9693525

These Agilent Varian HELITEST HAND HELD PROBE 10 M.  have part number 9693525, are new, and come with full Agilent Varian warranty. The Agilent PHD-4 is a portable, compact leak detector that runs on its own battery for up to four hours. Weighing only 2.6 kg (5.7 lbs) including the battery, it can be taken anywhere. The PHD-4 detects very small leaks in objects that have a slight helium/air pressure inside. It is sensitive to helium concentrations as small as 2 parts per million which equivalent to a leak rate of 5 x 10-6 atm-cc/sec. This level of sensitivity is far superior to the performance of other means of detecting leaks such as bubble testing. To accomplish this it relies on Agilent Varian?s proprietary and patented Selective Ion Pump Detection (SIPD) technology. Controlled by a microprocessor, the PHD-4 is easy to use with no training required. All tuning and zeroing are handled automatically. The display can be set to use any of four languages; English, French, German, and Italian.

Helium Leak Testing Basics
Helium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.

At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a "leak," is identified by a rise in the level of helium being analyzed by the machine.

Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.

While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user?s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection, make sure your "pilot" knows how to fly.

Why Is Helium Superior?
While many gases are used in leak detection, heliums qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas.

More information about these Agilent Varian HELITEST HAND HELD PROBE 10 M.  can be found by downloading the pdf catalog and documents below. Simply open the pdf catalog below, run the pdf search (ctrl F) and search for the 9693525.

Price

Product: Agilent Varian HELITEST HAND HELD PROBE 10 M., Helium Leak Detectors, Helium Leak Detectors,  PN  9693525

Condition: New
Warranty: Agilent Varian Warranty
Part Number: 9693525
Sale Price: €612.47

Currency Euro (Euro)

QTY:   

Manuals



AVAILABLE DOWNLOADS:
  Agilent 959, 959D Mass Spectrometer Helium Leak Detectors Operations manual.pdf (0)
  Agilent 959-959D Mass Spectrometer Manual.PDF (0)
  Agilent 979 Mass Spectrometer Manual.PDF (0)
  Agilent Helium Leak Detector Brochure.pdf (1.82 MB)
  Agilent Helium Leak Detector: G Series Manual.PDF (0)
  Agilent HLD Helium Leak Detector Brochure.PDF (1.45 MB)
  Agilent HLD Helium Leak Detector Operation Manual.pdf (3.53 MB)
  Agilent HLD Helium Leak Detector Service Brochure.PDF (2.55 MB)
  Agilent Leak Detection Catalog.pdf (0)
  Agilent Leak Detector Principles.PDF (5.00 MB)
  Agilent PHD-4 Portable Helium Leak Detector User Brochure.pdf (1.98 MB)
  Agilent PHD-4 Portable Helium Leak Detector User Manual.pdf (3.09 MB)
  Agilent Technologies C15 Component Agilent Helium Leak Detectors Brochure.PDF (1.52 MB)
  Agilent Varian 564 ION GAUGE Instruction Manual.pdf (5.20 MB)
  Agilent Varian 947 948 & 960 Helium Leak Detectors.pdf (5.20 MB)
  Agilent Varian 956 Helium Leak Detectors.pdf (18.9 MB)
  Agilent Varian 959 Helium Leak Detector Manual.pdf (1.95 MB)
  Agilent Varian 979 Helium Leak Detectors - Quick Reference.pdf (0.13 MB)
  Agilent Varian 979 Helium Leak Detectors.pdf (2.68 MB)
  Agilent Varian Ion Replacement for VS Series Leak Detector Manual.pdf (0)
  Agilent Varian Power Probe Sniffer Instruction Manual.pdf (5.20 MB)
  Agilent Varian VS Series Helium Leak Detector Operating Instrucions Manual.PDF (7.37 MB)
  Agilent Varian VS Series Helium Leak Detectors.pdf (2.44 MB)
  Agilent Varian VS Series Leak Detector Manual.pdf (0)
  Agilent Varian VS Specifiaction and Application Brochure.pdf (0)
  Agilent Varian Wireless Remote Base Unit for VS series and G86 series Leak Detectors_Instructions.pdf (2.20 MB)
  Agilent Varian Wireless Remote Base Unit for VS Series Leak Detectors (VSFLDWB) Field Installation Instructions.pdf (0)
  Agilent Varian Wireless Remote for HLD G86 Series and VS Leak Detectors_Manual.pdf (1.55 MB)
  Agilent Varian Wireless Remote for HLD Series Leak Detectors_Data Sheet.pdf (0.67 MB)
  Agilent VS Series Helium Leak Detector Manual.PDF (0)
  Agilent VS Series Helium Mass Spectrometer Leak Detectors, PR02, MR15, MD30, BR15, BD30, PD03, Operation Manual.pdf (0)
  Agilent VS Series Helium Mass Spectrometer Leak Detectors, PR02, MR15, MD30, BR15, BD30, PD03, Operation Manual.pdf (0)
  Agilent VS Series Helium Mass Spectrometer Leak Detectors, PR02, MR15, MD30, BR15, BD30, PD03, Operation Manual.pdf (0)
  Agilent VS Series Helium Mass Spectrometer Leak Detectors, PR02, MR15, MD30, BR15, BD30, PD03, Operation Manual.pdf (0)
  Agilent VS Series Helium Mass Spectrometer Leak Detectors, PR02, MR15, MD30, BR15, BD30, PD03, Operation Manual.pdf (0)
  Agilent VS Series Helium Mass Spectrometer Leak Detectors, PR02, MR15, MD30, BR15, BD30, PD03, Operation Manual.pdf (0)
  IVP HLD-Sniffer II Helium Sniffer Probe User Guide.pdf (0)
  Varian 947 High Production Helium Leak Detector Operation & Service Manual.pdf (0)
  Varian 947, 948, 960 Cabinet Model Helium Leak Detectors Data Sheet.pdf (0)
  Varian 947, 948, 960 Cabinet Model Helium Leak Detectors Data Sheet.pdf (0)
  Varian 947, 948, 960, High Production Helium Leak Detectors Operation and Service Manual.pdf (0)
  Varian 956 Portable Turbo Leak Detector Installation, Operation & Maintenance Instructions.pdf (0)
  Varian Leak Test Data Wizard Software Operation Manual.pdf (0)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001