Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-in
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent TriScroll Pumps On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Pfeiffer ASM340 Leak Detectors On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
The INFICON single Bayard-Alpert Hot Ion gauge BAG302 covers a wide measurement range from 1.3 × 10-9 to 6.7×10-2 mbar (1 × 10-9 to 5 × 10-2 Torr). The compact All-In-One Hot Ion gauge BAG302 offers an easy to exchange dual filament sensor, a built in OLED display, set-point relay and a log-linear analog output as well as an integrated RS485 digital interface for increased integration flexibility. These features combined with the rugged design makes the BAG302 an affordable and repeatable process to base pressure measurement instrument of its own and provides a high value/ low cost of ownership choice.

The INFICON Bayard-Alpert passive vacuum gauge heads BAG050, BAG051, BAG052 and BAG053 are designed for use with the INFICON Vacuum Gauge Controller VGC083A & VGC083B. Yttria coated iridium filaments are offered for general vacuum applications in air and inert gases such as N2 and argon. Select tungsten filaments for gases that are not compatible with yttria coated iridium filaments. BAG05x gauges may also be operated with compatible vacuum gauge controllers from other manufacturers. The INFICON passive Bayard-Alpert ionization vacuum gauges (BAG05x) are offered in three different configurations:

BAG050 is a EB-degas UHV nude ionization vacuum gauge capable of pressure measurement as low as 2×10-11 Torr.

BAG051 is a resistive degas (I2R) nude ionization vacuum gauge capable of pressure measurement as low as 4×10-10 Torr.

BAG052 and BAG053 are resistive degas (I2R) glass enclosed ionization vacuum gauges capable of pressure measurement as low as 4×10-10 Torr.

The INFICON passive Cold Cathode Gauge Heads MAG050 and MAG060 are designed for use with the INFICON Vacuum Gauge Controller VGC083C. They are constructed of a compact metal design resulting in a simple yet rugged gauge suitable for numerous industrial applications. Gauge Head MAG050 utilizes an elastomer internal seal while the MAG060 gauge head uses a metal seal allowing pressure measurements in the UHV range. The Gauge Head assembly can be easily disassembled and cleaned allowing Long term use with minimal down time. A Gauge Head ignition aid mounted on the anode improves the time it takes to set the Cold Cathode Gauge Head on.MAG050 measures down to 2×10-9 mbar while MAG060 is able to measure down to 1×10-10 mbar.MAG050 is bakeable up to 150°C and it is mainly intended for use in different industrial applications.MAG060 bakeable up to 250 °C and radiation resistant, which makes it an excellent choice for the use in R&D applications.

More information about these
57894.40527
Inficon Inc BAG051 Hot Ion DN40CF dual Tungsten Fil, Wide Range Vacuum Gauges , Wide Range Vacuum Gauges ,  PN  399-727
×

Load

Description

  
Inficon Inc BAG051 Hot Ion DN40CF dual Tungsten Fil, Wide Range Vacuum Gauges , Wide Range Vacuum Gauges ,  PN  399-727

These Inficon Inc BAG051 Hot Ion DN40CF dual Tungsten Fil  have part number 399-727, are new, and come with full Inficon Inc warranty. The INFICON single Bayard-Alpert Hot Ion gauge BAG302 covers a wide measurement range from 1.3 × 10-9 to 6.7×10-2 mbar (1 × 10-9 to 5 × 10-2 Torr). The compact All-In-One Hot Ion gauge BAG302 offers an easy to exchange dual filament sensor, a built in OLED display, set-point relay and a log-linear analog output as well as an integrated RS485 digital interface for increased integration flexibility. These features combined with the rugged design makes the BAG302 an affordable and repeatable process to base pressure measurement instrument of its own and provides a high value/ low cost of ownership choice.

The INFICON Bayard-Alpert passive vacuum gauge heads BAG050, BAG051, BAG052 and BAG053 are designed for use with the INFICON Vacuum Gauge Controller VGC083A & VGC083B. Yttria coated iridium filaments are offered for general vacuum applications in air and inert gases such as N2 and argon. Select tungsten filaments for gases that are not compatible with yttria coated iridium filaments. BAG05x gauges may also be operated with compatible vacuum gauge controllers from other manufacturers. The INFICON passive Bayard-Alpert ionization vacuum gauges (BAG05x) are offered in three different configurations:

BAG050 is a EB-degas UHV nude ionization vacuum gauge capable of pressure measurement as low as 2×10-11 Torr.

BAG051 is a resistive degas (I2R) nude ionization vacuum gauge capable of pressure measurement as low as 4×10-10 Torr.

BAG052 and BAG053 are resistive degas (I2R) glass enclosed ionization vacuum gauges capable of pressure measurement as low as 4×10-10 Torr.

The INFICON passive Cold Cathode Gauge Heads MAG050 and MAG060 are designed for use with the INFICON Vacuum Gauge Controller VGC083C. They are constructed of a compact metal design resulting in a simple yet rugged gauge suitable for numerous industrial applications. Gauge Head MAG050 utilizes an elastomer internal seal while the MAG060 gauge head uses a metal seal allowing pressure measurements in the UHV range. The Gauge Head assembly can be easily disassembled and cleaned allowing Long term use with minimal down time. A Gauge Head ignition aid mounted on the anode improves the time it takes to set the Cold Cathode Gauge Head on.MAG050 measures down to 2×10-9 mbar while MAG060 is able to measure down to 1×10-10 mbar.MAG050 is bakeable up to 150°C and it is mainly intended for use in different industrial applications.MAG060 bakeable up to 250 °C and radiation resistant, which makes it an excellent choice for the use in R&D applications.

More information about these Inficon Inc BAG051 Hot Ion DN40CF dual Tungsten Fil  can be found by downloading the pdf catalog and documents below. Simply open the pdf catalog below, run the pdf search (ctrl F) and search for the 399-727.

Price

Product: Inficon Inc BAG051 Hot Ion DN40CF dual Tungsten Fil, Wide Range Vacuum Gauges , Wide Range Vacuum Gauges ,  PN  399-727

Condition: New
Warranty: Inficon Inc Warranty
Part Number: 399-727
Sale Price: ₹57,894.41

Currency Indian Rupee (INR)

QTY:   

Manuals



AVAILABLE DOWNLOADS:
  Inficon BAG050, BAG051, BAG052, BAG053, BAG055 Brochure.pdf (0.39)
  Inficon BAG302 Bayard-Alpert Hot Ion Gauge Brochure.pdf (0.43)
  Inficon BAG402 Medium to UHV Gauge Brochure.pdf (0.39)
  Inficon BCG450 UHV Gauge Brochure.pdf (0.34)
  Inficon BPG400 UHV Gauge Brochure.pdf (0.23)
  Inficon CDG025D Sky Capacitance Diaphragm Gauge Brochure.pdf (0.45 MB)
  Inficon CDG025D Vacuum Gauge Brochure.pdf (2.25 MB)
  Inficon Hot Ion Gauges Overview Brochure.pdf (2.83)
  Inficon HPG400 High Vacuum Gauge Brochure.pdf (0.28)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com