Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-al
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Edwards nEXT300D TStations On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent TriScroll Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3

Agilent Varian FRG-720 KF25 Bayard Alpert, Pirani, Single Filament Replacement Sensor FRG720KF25RS

Condition:
  New
Part Number:
  P107238
Warranty:
  Varian Warranty

Available Now   1  

Sale: L141,129.21

Agilent Varian FRG-720 KF25 Bayard Alpert, Pirani, Single Filament Replacement Sensor FRG720KF25RS 141129.21
Currency: Albanian Lek (ALL)

Description

Agilent Varian FRG-720 Pirani and Bayard Alpert SINGLE Filament Replacement Sensor. Hot Cathode Ion, 760 to 3.8 X 10-10 Torr,
NW25 KF25 Flange.
Agilent Varian PN FRG720KF25RS.

This Agilent Varian Single Filament Replacement Sensor is for the FRG720 Bayard Alpert and Pirani Combination Gauge with a NW25 KF25 Flange. This filament sensor is replaceable by the user. The gauge can measure pressure from 3.8 X 10-10 Torr to atmosphere. Over the whole measuring range, the gauge has a continuous characteristic curve and its measuring signal is output as logarithm of the pressure. The gauge functions with a Bayard-Alpert hot cathode ionization measurement system (for < 2.0×10-2 Torr) and a Pirani measurement system (for >5.5×10-3 Torr). In the overlapping pressure range of 2.0×10-2 to 5.5×10-3 Torr, a mixed signal of the two measurement systems is output. The hot cathode is switched on by the Pirani measurement system only below the switching threshold of 2.4×10-2 Torr (to prevent filament burnout). It is switched off when the pressure exceeds 3.2×10-2 Torr.

This is the replaceable single filament sensor with the NW25 KF25 flange. This replacement sensor is for the FRG720 combination gauges only. Signal cables and pressure controllers sold separately on this website. Agilent Varian Part Number FRG720KF25RS. A complete Operating Instruction Manual and Spec Sheet is available for download in .pdf format below under AVAILABLE DOWNLOADS.

Compatible with FRG720 Single Filament Combination Gauge Part Numbers:
  • FRG720KF25
  • FRG720KF25D
  • FRG720KF25SP

Brochure

Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.5156