Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-at
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent Varian Helium Leak Detectors On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Edwards nXDS6i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 3.6 CFM. PN: A73501983
Out of Stock
Expecting 7
Anticipated Arrival 5 on 2025-01-03


Edwards nXDS6i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 3.6 CFM. Edwards Part Number: A73501983. This Edwards nXDS6i dry scroll roughing/backing pump has a pumping speed of 3.6 cfm (6.2 m3/hr), and an ultimate vacuum of 0.015 Torr (0.020 mbar). It has KF-25 (NW25) inlet and outlet ports. It requires 100-240 VAC single phase power and has a standard C14 power connector. The nXDS6i draws 10A@120VAC (6A@240 VAC). The nXDS6i scroll pump produces a noise level up to twenty times less than competing products at 52 dB(A). The pump has an onboard inverter controller which allows the pump to be controlled either manually with easy to use push buttons, or remotely via its RS232/RS485 interface when connected to an Edwards TIC or TAG controller, or a user supplied software interface. This Edwards nXDS6i dry scroll pump has part number A73501983. Edwards nXDSi pumps are truly dry vacuum pumps as all the bearings, with their hydrocarbon lubricant, are isolated from the vacuum space. The nXDSi series of pumps is the next generation in completely oil free, dry scroll pumps and offer increased pumping speeds, lower ultimate pressures, lower power consumption and lower noise than previous models. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. Edwards nXDSi pumps feature the latest in tip seal technology giving them significantly longer life between tip seal changes (up to five year service intervals), and are designed to be completely field serviceable. The nXDSi integral pump controller monitors power and temperature, and will protect the pump in the event of operation under sustained high load or under fault conditions. The pump controller has a unique feature to control the speed of the pump in standby mode to 70% of full speed or with other push buttons to increase or decrease pump speed to save wear and tear on tip seals and bearing service life. The logic interface is designed to support RS232/RS485 serial or parallel control and monitoring through the DB15 connector. APPLICATIONSGeneral clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Backing turbo pumps Centrifuges, ultra-high speed Coating Cryogenics Degassing/curing - oil, epoxy resin Distillation/extraction/filtration Laboratory bench top vacuum Lasers, gas recovery and recirculation Research and development Surface science instruments

Condition: New



Part Number: P105126



Price: €5,446.08


Regular Price: €7,261.44




Currency: Euro (Euro)

Edwards nXDS10i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 6.7 CFM. PN: A73601983
In Stock
13


Edwards nXDS10i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 6.7 CFM. Edwards Part Number: A73601983. This Edwards nXDS10i dry scroll roughing/backing pump has a pumping speed of 6.7 cfm (11.4 m3/hr), and an ultimate vacuum of 0.005 Torr (0.007 mbar). It has KF-25 (NW25) inlet and outlet ports. It requires 100-240 VAC single phase power and has a standard C14 power connector. The nXDS10i draws 10A@120VAC (6A@240 VAC). The nXDS10i scroll pump produces a noise level up to twenty times less than competing products at 52 dB(A). The pump has an onboard inverter controller which allows the pump to be controlled either manually with easy to use push buttons, or remotely via its RS232/RS485 interface when connected to an Edwards TIC or TAG controller, or a user supplied software interface. This Edwards nXDS10i dry scroll pump has part number A73601983. Edwards nXDSi pumps are truly dry vacuum pumps as all the bearings, with their hydrocarbon lubricant, are isolated from the vacuum space. The nXDSi series of pumps is the next generation in completely oil free, dry scroll pumps and offer increased pumping speeds, lower ultimate pressures, lower power consumption and lower noise than previous models. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. Edwards nXDSi pumps feature the latest in tip seal technology giving them significantly longer life between tip seal changes (up to five year service intervals), and are designed to be completely field serviceable. The nXDSi integral pump controller monitors power and temperature, and will protect the pump in the event of operation under sustained high load or under fault conditions. The pump controller has a unique feature to control the speed of the pump in standby mode to 70% of full speed or with other push buttons to increase or decrease pump speed to save wear and tear on tip seals and bearing service life. The logic interface is designed to support RS232/RS485 serial or parallel control and monitoring through the DB15 connector. APPLICATIONSGeneral clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Backing turbo pumps Centrifuges, ultra-high speed Coating Cryogenics Degassing/curing - oil, epoxy resin Distillation/extraction/filtration Laboratory bench top vacuum Lasers, gas recovery and recirculation Research and development Surface science instruments

Condition: New



Part Number: P105130



Price: €6,806.90


Regular Price: €9,075.87




Currency: Euro (Euro)

Edwards nXDS15i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 8.9 CFM. PN: A73701983
In Stock
1
Expecting 2
Anticipated Arrival 1 on 2025-01-03


Edwards nXDS15i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 10.1 CFM. Edwards Part Number: A73701983. This Edwards nXDS15i dry scroll roughing/backing pump has a pumping speed of 8.9 cfm (15.1 m3/hr), and an ultimate vacuum of 0.005 Torr (0.007 mbar). It has KF-25 (NW25) inlet and outlet ports. It requires 100-240 VAC single phase power and has a standard C14 power connector. The nXDS15i has a high efficiency radial air-gap motor which draws just 300W (typical). The nXDS15i scroll pump produces a noise level up to twenty times less than competing products at 52 dB(A). The pump has an onboard inverter controller which allows the pump to be controlled either manually with easy to use push buttons, or remotely via its RS232/RS485 interface when connected to an Edwards TIC or TAG controller, or a user supplied software interface. This Edwards nXDS15i dry scroll pump has part number A73701983. Edwards nXDSi pumps are truly dry vacuum pumps as all the bearings, with their hydrocarbon lubricant, are isolated from the vacuum space. The nXDSi series of pumps is the next generation in completely oil free, dry scroll pumps and offer increased pumping speeds, lower ultimate pressures, lower power consumption and lower noise than previous models. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. Edwards nXDSi pumps feature the latest in tip seal technology giving them significantly longer life between tip seal changes (up to five year service intervals), and are designed to be completely field serviceable. The nXDSi integral pump controller monitors power and temperature, and will protect the pump in the event of operation under sustained high load or under fault conditions. The pump controller has a unique feature to control the speed of the pump in standby mode to 70% of full speed or with other push buttons to increase or decrease pump speed to save wear and tear on tip seals and bearing service life. The logic interface is designed to support RS232/RS485 serial or parallel control and monitoring through the DB15 connector. APPLICATIONSGeneral clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Backing turbo pumps Centrifuges, ultra-high speed Coating Cryogenics Degassing/curing - oil, epoxy resin Distillation/extraction/filtration Laboratory bench top vacuum Lasers, gas recovery and recirculation Research and development Surface science instruments

Condition: New



Part Number: P105131



Price: €8,171.21


Regular Price: €10,894.95




Currency: Euro (Euro)

Edwards nXDS20i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 13.0 CFM. PN: A73801983
In Stock
5


Edwards nXDS20i Oil-Free Dry Scroll Vacuum Pump, 100-240 VAC, 13.0 CFM. Edwards Part Number: A73801983. This Edwards nXDS20i dry scroll roughing/backing pump has a pumping speed of 13 cfm (22.0 m3/hr), and an ultimate vacuum of 0.022 Torr (0.030 mbar). It has KF-25 (NW25) inlet and outlet ports. It requires 100-240 VAC single phase power and has a standard C14 power connector. The nXDS20i draws 10A@120VAC (6A@240 VAC). The nXDS20i scroll pump produces a noise level up to twenty times less than competing products at 52 dB(A). The pump has an onboard inverter controller which allows the pump to be controlled either manually with easy to use push buttons, or remotely via its RS232/RS485 interface when connected to an Edwards TIC or TAG controller, or a user supplied software interface. This Edwards nXDS20i dry scroll pump has part number A73801983. Edwards nXDSi pumps are truly dry vacuum pumps as all the bearings, with their hydrocarbon lubricant, are isolated from the vacuum space. The nXDSi series of pumps is the next generation in completely oil free, dry scroll pumps and offer increased pumping speeds, lower ultimate pressures, lower power consumption and lower noise than previous models. Gas ballast allows for pumping of condensable vapours including, water, solvents, dilute acids and bases. Edwards nXDSi pumps feature the latest in tip seal technology giving them significantly longer life between tip seal changes (up to five year service intervals), and are designed to be completely field serviceable. The nXDSi integral pump controller monitors power and temperature, and will protect the pump in the event of operation under sustained high load or under fault conditions. The pump controller has a unique feature to control the speed of the pump in standby mode to 70% of full speed or with other push buttons to increase or decrease pump speed to save wear and tear on tip seals and bearing service life. The logic interface is designed to support RS232/RS485 serial or parallel control and monitoring through the DB15 connector. APPLICATIONSGeneral clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Backing turbo pumps Centrifuges, ultra-high speed Coating Cryogenics Degassing/curing - oil, epoxy resin Distillation/extraction/filtration Laboratory bench top vacuum Lasers, gas recovery and recirculation Research and development Surface science instruments

Condition: New



Part Number: P105132



Price: €9,193.65


Regular Price: €12,258.21




Currency: Euro (Euro)

Input Power Cord Mains Cable 2m Long 115 VAC for all Edwards nXDS and nXDSi Dry Scroll Pumps.
In Stock
121


Input Power Cord Mains Cable 2m Long 115 VAC for all Edwards nXDS and nXDSi Dry Scroll Pumps. This is an input power cord (mains cable), 115 VAC, 2 meters long, with US plug 5-15P to C13 Connector. It is used on all Edwards nXDS and nXDSi dry scroll pumps. Replaces Edwards part number B8J200813, A50507000 or D40013120, and is the same as our part number P106129). This power cord is used on: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir

Condition: New



Part Number: P102990



Price: €51.85




Currency: Euro (Euro)

Edwards nXDS Dry Scroll Vacuum Pump Tip Seal Kit, For Minor Rebuild Service, Fits All nXDS Series Pumps, PN: A735-01-801
In Stock
18
Expecting 12
Anticipated Arrival 12 on 2025-01-22


Edwards nXDS Dry Scroll Vacuum Pump Tip Seal Kit, For Minor Rebuild Service, Fits All nXDS Series Pumps. Edwards Vacuum Part Number PN: A735-01-801. These Edwards nXDS series dry scroll pump tip seal kits are used when a minor rebuild service is required. This is typically needed 2-years after the pump is placed into service, often required between 12,000 and 16,000 operating hours. The pump will start to lose its ability to reach the lowest ultimate pressure as the tip seals become worn out. The base pressure for a new nXDS pump is often measured at 10 mTorr or less when evacating a good clean leak-tight vacuum chamber. If you notice that your base presure is now only getting to 25 mTorr then the tip seal will likely need to be replaced. Please see the instructions shown in the tip seal replacement manual in our Downloads section below.Works With All Edwards nXDs Series Dry Scroll Vacuum PumpsEdwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir

Condition: New



Part Number: P105546



Price: €885.55




Currency: Euro (Euro)

Edwards Major Rebuild Kit, Bearing Replacement, For All Edwards nXDS Dry Scroll Pumps, PN: A735-01-810
In Stock
7


Edwards Major Rebuild Kit, Bearing Replacement, For All Edwards nXDS Dry Scroll Pumps. Edwards Vacuum Part Number PN: A73501810. These Edwards nXDS dry scroll pump major rebuild bearing replacement service kits Include the front angular contact bearings, shaft end cap, washers, screws, plugs, tip-seals, and O-rings required for a major pump overhaul. These kits work with the following Edwards nXDS dry scroll vacuum pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir

Condition: New



Part Number: P1011705



Price: €1,717.64




Currency: Euro (Euro)

Edwards Major Rebuild Kit, Bearing Replacement, For All Edwards nXDS Dry Scroll Pumps, PN: A735-01-802
In Stock
3


Edwards Major Rebuild Kit, Bearing Replacement, For All Edwards nXDS Dry Scroll Pumps. Edwards Vacuum Part Number PN: A73501802. These Edwards nXDS dry scroll pump major rebuild bearing replacement service kits Include the front angular contact bearings, shaft end cap, washers, screws, plugs and O-rings required for a major pump overhaul. These nXDS bearing replacement kits do not include the tip seals. These rebuild kits work with the following Edwards nXDS dry scroll vacuum pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir

Condition: New



Part Number: P105331



Price: €1,986.58




Currency: Euro (Euro)

Edwards Chemical Resistant Conversion Kit for nXDS6i, nXDS10i, nXDS15i To Convert Them to IC (Chemical Resistant) Pumps. PN: A735-01-807
In Stock
1


Edwards Chemical Resistant Conversion Kit for nXDS6i, nXDS10i, nXDS15i To Convert Them to ic (Chemical Resistant) Pumps.Edwards Vacuum Part Number PN: A735-01-807These Edwards chemical resistant conversion kits are used to convert an nXDS6i, nXDS10i or nXDS15i dry scroll to the chemical resistant versions, nXDS6ic, nXDS10ic or nXDS15ic. This adapter kit allows you to convert a standard nXDS-i series pump into the nXDS-ic chemical resistant version. This conversion may be necessary if you wish to use your pump on applications involving corrosive gas substances. For install instructions see the Edwards nXDS dry scroll pump accessories manual in the Downloads section below, pages 21-23. The main components in this kit are Chemraz chemical resistant O-rings and valves, this rubber material has good chemical resistance. These kits work with the following Edwards nXDS dry scroll vacuum pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i

Condition: New



Part Number: P109572



Price: €1,182.94




Currency: Euro (Euro)

Edwards Chemical Resistant Conversion Kit for nXDS20i To Convert Them to ic (Chemical Resistant) Pumps, PN: A735-01-808
In Stock
1


Edwards Chemical Resistant Conversion Kit for nXDS20i To Convert Them to ic (Chemical Resistant) Pumps. Edwards Vacuum Part Number PN: A735-01-808. These Edwards chemical resistant conversion kits are used to convert an nXDS20i dry scroll pump to the chemical resistant versions, nXDS20ic. This adapter kit allows you to convert a standard nXDS-i series pump into the nXDS-ic chemical resistant version. This conversion may be necessary if you wish to use your pump on applications involving corrosive gas substances. For install instructions see the Edwards nXDS dry scroll pump accessories manual in the Downloads section below, pages 21-23. The main components in this kit are Chemraz chemical resistant O-rings and valves, this rubber material has good chemical resistance. These kits work with the following Edwards nXDS dry scroll vacuum pumps: Edwards nXDS20i

Condition: New



Part Number: P109573



Price: €2,024.61




Currency: Euro (Euro)

Edwards nXDS Series Dry Scroll Vacuum Pump Micron Filter Trap, Can Be Used On The Inlet or Pump Exhaust, KF-25 Vacuum Flanges, PN: A505-97-805
In Stock
1
Expecting 1
Anticipated Arrival 1 on 2025-01-22


Edwards nXDS Series Dry Scroll Vacuum Pump Micron Filter Trap, Can Be Used On The Inlet or Pump Exhaust, KF-25 Vacuum Flanges. Edwards Vacuum Part Number PN: A505-97-805. These Edwards nXDS micron filter traps can either be used on the pump''s inlet to protect from debris that might be sucked in from the vacuum chamber or they can be used between the vacuum pump and the exhaust line to trap out tip-seal dust. These Edwards nXDS filter traps are supplied ready with a 5 micron element, have KF-25 vacuum flanges, and Edwards part number A505-97-805. Replacement Filter Media 1 micron, A505-97-803. P108771 Replacement Filter Media 5 micron, A505-97-802. P108772 Works With All Edwards nXDs Series Dry Scroll Vacuum Pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir

Condition: New



Part Number: P105484



Price: €1,535.64




Currency: Euro (Euro)

Edwards nXDS Replacement Trap Filter Element, For All nXDS Series Dry Scroll Pumps, 1 Micron Element, PN: A505-97-803
In Stock
3


Edwards nXDS Replacement Trap Filter Element, For All nXDS Series Dry Scroll Pumps, 1 Micron Element. Edwards Vacuum Part Number PN: A505-97-803. These Edwards nXDS replacement trap filter elements are designed to capture very small 1 micron sized particles. They are replacement elements for the Edwards nXDS filter trap assembly with part number A505-97-805 and the element should be changed every year of service. These 1 micron replacement trap filter elements work with all Edwards nXDS series dry scroll vacuum pumps and have Edwards part number A505-97-803.Fits Edwards nXDS Canister-Style Trap Filter Assembly, A505-97-805. P105484Replacement Filter Media 1 micron, A505-97-803. P108771Replacement Filter Media 5 micron, A505-97-802. P108772 Works With All Edwards nXDs Series Dry Scroll Vacuum PumpsEdwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir

Condition: New



Part Number: P108771



Price: €485.13




Currency: Euro (Euro)

Edwards nXDS Replacement Trap Filter Element, For All nXDS Series Dry Scroll Pumps, 5 Micron Element, PN: A505-97-802
In Stock
1
Expecting 1
Anticipated Arrival 1 on 2025-01-22


Edwards nXDS Replacement Trap Filter Element, For All nXDS Series Dry Scroll Pumps, 5 Micron Element. Edwards Vacuum Part Number PN: A505-97-802. These Edwards nXDS replacement trap filter elements are designed to capture very small 5 micron sized particles. They are replacement elements for the Edwards nXDS filter trap assembly with part number A505-97-805 and the element should be changed every year of service. These 5 micron replacement trap filter elements work with all Edwards nXDS series dry scroll vacuum pumps and have Edwards part number A505-97-802.Fits Edwards nXDS Canister-Style Trap Filter Assembly, A505-97-805. P105484Replacement Filter Media 1 micron, A505-97-803. P108771Replacement Filter Media 5 micron, A505-97-802. P108772 Works With All Edwards nXDs Series Dry Scroll Vacuum PumpsEdwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir

Condition: New



Part Number: P108772



Price: €226.80




Currency: Euro (Euro)

Edwards nXDS Exhaust Silencer Kit, For Operating Noise Reduction, Fits All nXDS Series Dry Scroll Pumps, KF-25 Vacuum Flange, PN: A505-97-000
In Stock
6


Edwards nXDS Exhaust Silencer Kit, For Operating Noise Reduction, Fits All nXDS Series Dry Scroll Pumps, KF-25 Vacuum Flange. Edwards Vacuum Part Number PN: A505-97-000. These Edwards nXDS exhaust silencer kits are used to reduce the operating noise of the scroll pump. They are effective at dampening the roughing sound that is heard when the pump starts to evacuate the chamber, they act as a vacuum pump muffler. These Edwards nXDS exhaust silencers are designed to vent into the room and should only be used on nXDSi series pumps that are evacuating air from a clean vacuum chamber. They should not be used with chemical series nXDS-ic pumps that are used on chemical applications. These Edwards nXDS exhaust silencer kits have a KF-25 vacuum flange and are supplied with a KF-25 centering ring, KF-25 clamp, and have Edwards part number A505-97-000. Replacement nXDS Exhaust Silencer Element, A505-97-800. P105485 Works With All Edwards nXDs Series Dry Scroll Vacuum Pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i

Condition: New



Part Number: P102553



Price: €411.64




Currency: Euro (Euro)

Edwards nXDS Replacement Exhaust Silencer Element Spare, For Operating Noise Reduction, Fits All nXDS Series Dry Scroll Pumps. PN: A505-97-800
In Stock
1


Edwards nXDS Replacement Exhaust Silencer Element Spare, For Operating Noise Reduction, Fits All nXDS Series Dry Scroll Pumps. Edwards Vacuum Part Number PN: A505-97-800. These Edwards nXDS replacement exhaust silencer element spares are used to reduce the operating noise of the scroll pump. They are effective at dampening the roughing sound that is heard when the pump starts to evacuate the chamber, they act as a vacuum pump muffler. These Edwards nXDS exhaust silencers are designed to vent into the room and should only be used on nXDSi series pumps that are evacuating air from a clean vacuum chamber. They should not be used with chemical series nXDS-ic pumps that are used on chemical applications. These Edwards nXDS replacement exhaust silencer elements should be replaced every year during preventive maintenance (PM) as they capture the pump''s exhausted tip-seal dust and will eventually become clogged. They have Edwards part number A505-97-000. Fits Edwards nXDS Exhaust Silencer Assembly, A505-97-000. P102553 Works With All Edwards nXDs Series Dry Scroll Vacuum PumpsEdwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i

Condition: New



Part Number: P105485



Price: €326.83




Currency: Euro (Euro)

Edwards nXDS Vacuum Gas Ballast Control Knob, Fits nXDS-i and nXDS-ic Dry Scroll Vacuum Pumps, PN: A735-01-759
Out of Stock


Edwards nXDS Vacuum Gas Ballast Control Knob, Fits All nXDS Dry Scroll Vacuum Pumps.Edwards Vacuum Part Number PN: A735-01-759. These Edwards nXDS gas ballast control knobs are used with the nXDS-i standard and nXDS-ic chemical resistant series dry scroll vacuum pumps. The gas ballast is a control valve that intentional introduces a small room-air leak into the second stage of the vacuum pump, producing a positive flow throughput, and sweeping out vapors from volitale compounds, such as, water and others. When pumping volitale compounds, like water vapor, they are compressed inside the pump and condense into a liquid. When condensation happens the ultimate vacuum pressure of the vacuum pump is now limited to the vapor pressure of the volitale contamenting compoud, for example, the room temperature vapor pressure of water is around 23.8 Torr. The gas ballast should be opened while the pump is warmed up to help evaporate and sweep out the volitale vapors. It is often good to leave the pump running overnight with the gas ballast open to rid it of volitale compounds. The gas ballast should not be used when pumping flamable, as the gas ballast introduces air which contains oxygen. The gas ballast should also not be used when pumping toxic compounds, as the gas ballast introduces a leak into the room air, if the pump is turned off, a small amounts of vapors from inside the pump could potentially leak out through the gas ballast port into the room air. These replacement Edwards nXDS gas ballast control knobs have part number A735-01-759. Works With Edwards nXDs Series Dry Scroll Vacuum Pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Non-Flamable and Non-Toxic Gases Edwards nXDS10ic Non-Flamable and Non-Toxic Gases Edwards nXDS15ic Non-Flamable and Non-Toxic Gases Edwards nXDS20ic Non-Flamable and Non-Toxic Gases

Condition: New



Part Number: P1010097



Price: €70.78




Currency: Euro (Euro)

Edwards nXDS Dry Scroll Pump Gas Ballast Purge Adapter, Fits nXDS-i and nXDS-ic Dry Scroll Vacuum Pumps. PN: A735-01-809
In Stock
1
Expecting 2
Anticipated Arrival 2 on 2024-12-20


Edwards nXDS Dry Scroll Pump Gas Ballast Purge Adapter, Fits nXDS-i and nXDS-ic Dry Scroll Vacuum Pumps. Edwards Vacuum Part Number PN: A735-01-809. These Edwards nXDS gas ballast purge adapters may be fitted in place of the original gas ballast control knob and used to supply an inert purge gas, such as nitrogen. They are commonly used with the nXDS-i standard and nXDS-ic chemical resistant series dry scroll vacuum pumps. It is important to replace the gas ballast control knob with this purge gas adapter when you are using the nXDS pump on chemical applications, please read below. The gas ballast is a control valve, that intentionally introduces a small room-air leak into the second stage of the vacuum pump, producing a positive flow throughput, and sweeping out vapors from volatile compounds, such as, water and others. When pumping volatile compounds, like water vapor, they are compressed inside the pump and condense into a liquid. When condensation happens the ultimate vacuum pressure of the pump is now limited to the vapor pressure of the volatile contaminating compound, for example, the room temperature vapor pressure of water is around 23.8 Torr. The gas ballast should be opened while the pump is warmed up to help evaporate and sweep out the volatile vapors. It is often good to leave the pump running overnight with the gas ballast open to rid it of volatile compounds. The gas ballast should not be used when pumping flammable compounds, as the gas ballast introduces air which contains oxygen. The gas ballast should also not be used when pumping toxic compounds, as the gas ballast introduces a leak into the room air, if the pump is turned off, a small amount of vapors from inside the pump could potentially leak out through the gas ballast port into the room air. These Edwards nXDS gas ballast purge adapters have part number A735-01-809. Works With Edwards nXDs Series Dry Scroll Vacuum Pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic

Condition: New



Part Number: P105482



Price: €455.78




Currency: Euro (Euro)

Edwards nXDS Ballast Blank-Off Adaptor Kit, Converts Standard nXDS-i Pumps into The nXDS-ir Version, PN: A735-01-806
In Stock
1


Edwards nXDS Ballast Blank-Off Adapter Kit, Converts Standard nXDS-i Pumps into The nXDS-ir Version. Edwards Vacuum Part Number PN: A735-01-806. These Edwards nXDS gas ballast blank adapters are for the nXDS dry scroll vacuum pumps. This adapter kit allows you to convert a standard nXDS-i pump into an nXDS-ir version. The nXDS-ir series pumps are designed for special applications, such as gas recirculation, rare gas pumping and recovery, or other applications where the dilution of the pumped gas is undesirable, or where sealing is integral to minimizing potential gas loss. These Edwards nXDS gas ballast blank adapters are often used to replace the standard gas ballast control knob, so that the gas ballast cannot be accidentally opened, the advantage is improved leak tightness at the ballast location. They have Edwards part number A735-01-806.Works With Edwards nXDs Series Dry Scroll Vacuum Pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic

Condition: New



Part Number: P105483



Price: €241.37




Currency: Euro (Euro)

Edwards Exhaust Port Nozzle Adapter, 3/4 Inch BSP to 15 mm I.D. Hose, Fits nXDS Dry Scroll and E2M Series Oil-Seal Rotary Vacuum Pumps, PN: A505-09-000
In Stock
4


Edwards Exhaust Port Nozzle Adapter, 3/4 Inch BSP to 15 mm I.D. Hose, Fits nXDS Dry Scroll and E2M Series Oil-Seal Rotary Vacuum Pumps. Edwards Vacuum Part Number PN: A505-09-000. These Edwards nXDS and E2M series pump exhaust port to hose adapters may be fitted in place of the original KF-25 port and used to connect the pump''s 3/4 BSPT threaded exhaust directly to 15 mm I.D. rubber hose. These Edwards exhaust port adapters are made of plastic, supplied with Viton O-ring, and have part number A505-09-000. Installation instructions are shown in our Downloads section below. Fit & Size: 3/4 inch BSP to 15 mm (5/8) PVC hose or 15mm rubber hose. O-ring: Viton. Material: Plastic. Edwards Part No. A505-09-000. Works With Edwards nXDS and E2M Vacuum Pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir Edwards RV3 Edwards RV8 Edwards RV12 Edwards E2M2 Edwards E2M5 Edwards E2M8 Edwards E2M12 Edwards E1M18 Edwards E2M18 Edwards E2M28 Edwards E2M30

Condition: New



Part Number: P102717



Price: €60.72




Currency: Euro (Euro)

Edwards Vibration Isolator Rubber Feet, Used with nXDS and nXR Series Vacuum Pumps, 4 Each, PN: A24801441
Out of Stock


Edwards Vibration Isolator Rubber Feet, Used with nXDS and nXR Series Vacuum Pumps, 4 Each. Edwards Vacuum Part Number: A24801441. These Edwards nXDS and nXR series pump vibration isolation rubber mounting feet, may be installed onto the base of the pump and connected to a cabinet or vacuum system frame. These vacuum pump mounts effectively isolated the mechanical pump vibrations from the surrounding vacuum system. They are sold in a pack of 4 each, are made of rubber, supplied with threaded fasteners, and have part number: A24801441. Fit & Size: Material: Rubber. Edwards PN: A24801441 Works with Edwards nXDS and nXR series Vacuum Pumps: Edwards nXDS6i Edwards nXDS10i Edwards nXDS15i Edwards nXDS20i Edwards nXDS6ic Edwards nXDS10ic Edwards nXDS15ic Edwards nXDS20ic Edwards nXDS6ir Edwards nXDS10ir Edwards nXDS15ir Edwards nXDS20ir Edwards nXR30i Edwards nXR40i Edwards nXR60i Edwards nXR90i

Condition: New



Part Number: P1012947



Price: €290.84




Currency: Euro (Euro)

Ideal Vacuum XactGauge Convection-Enhanced Pirani Gauge Kit, XGC-320 Controller, XGC-321 KF-25 Gauge, 10 ft. Sensor Cable, PS, 2 Set Points
In Stock
38


Ideal Vacuum XactGauge Convection-Enhanced Pirani Gauge Kit, XGC-320 Controller, XGC-321 KF-25 Gauge, 10 ft. Sensor Cable, PS, 2 Set Points Complete Kit Includes: XactGauge XGC-320 Convection-Enhanced Controller, XGC-321 KF-25 Sensor Gauge, 3 m (10 ft.) Sensor Cable & Power Supply. Features: Inexpensive solution for Pirani type thermal conductivity gauges Convection-Enhanced Pirani sensor gauges available in 8 different flange sizes Accurate pressure measurements from 1x10-4 to 1000 Torr Compact 1/8-DIN package fits on bench or in instrument panel cutout Bright, easy to read, 4 digit OLED display Intuitive front panel controls for calibration and parameter adjustments Switch between Torr, mBar and Pa units quickly Serial RS232/RS485 DB9 I/O interface for remote control 2 set points 4 analog outputs Compatible with Granville-Phillips® 275 Convectron® and Inficon PGE050 Pirani Gauge Enhanced sensors and cables. The Ideal Vacuum XactGauge XGC-320 Convection Enhanced Pirani Gauge Controller is an inexpensive solution for simple readout of Pirani type thermal conductivity gauges with added features for ease of use and system integration. Use with any of our eight (8) XactGauge Enhanced Pirani Sensor Gauges to obtain accurate pressure measurements ranging from 1x10-4 to 1000 Torr. Our XactGauge XGC-320 Controller, conveniently housed in a compact 1/8-DIN enclosure, can be used on your benchtop or mounted in an instrument panel cutout. The bright, OLED 4 digit display is easy to read. Intuitive front panel controls allow direct gauge calibration and simple adjustment of vacuum measurement parameters. The XactGauge XGC-320 Convection-Enhanced Pirani Gauge Controller is powered by user supplied 12 to 28 VDC, 2 W, or by our XactGauge Enhanced Pirani Controller power supply. The XGC-320 Controller has a serial RS232/RS485 (DB-9) remote I/O interface, two (2) setpoints, and four (4) analog relay outputs, each rated at 1 A at 30 VDC. This XGC-320 Controller is compatible with other manufacturer’s Pirani type gauges and cables, including the Granville-Phillips® 275 Convectron® and the Inficon PGE050 Pirani Gauge Enhanced. Thermal conductivity gauges measure pressure indirectly by sensing the loss of heat from a sensor to the surrounding gas. The higher the pressure of the gas, the more heat is conducted away from the sensor. Pirani thermal conductivity gauges maintain a sensor (usually a wire) at a constant temperature and measure the current or power required to maintain that temperature. A standard Pirani gauge has a useful measuring range of about 10-4 Torr to 10 Torr. Convection-enhanced Pirani gauges take advantage of the convection current inside the sensor to extend the pressure measurement range to just above atmosphere. The XactGauge is supplied factory calibrated using Nitrogen (N2) gas. When measuring gasses other than Nitrogen/Air, accurate correction must be made for the difference in thermal conductivity between nitrogen and the gas in use, particularly at pressures above 1 Torr. DO NOT USE for explosive, corrosive or toxic gasses.

Condition: New



Part Number: P1010252



Price: €1,130.95


Regular Price: €1,330.53




Currency: Euro (Euro)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com