Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-au
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent TriScroll Pumps On Sale Adixen 2021C2 Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent Varian Helium Leak Detectors On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Agilent IDP-7 Dry Scroll Vacuum Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, No Inlet, Delivery Pressure Range 100-1500 PSIG, SEQ3030NI
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030NI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109546



Price: $2,315.73



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-320, Delivery Pressure Range 100-1500 PSIG, SEQ3030320
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109373



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-326, Delivery Pressure Range 100-1500 PSIG, SEQ3030326
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109374



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-330, Delivery Pressure Range 100-1500 PSIG, SEQ3030330
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-330 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109375



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-346, Delivery Pressure Range 100-1500 PSIG, SEQ3030346
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-346 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109376



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-350, Delivery Pressure Range 100-1500 PSIG, SEQ3030350
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109377



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-540, Delivery Pressure Range 100-1500 PSIG, SEQ3030540
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109378



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-580, Delivery Pressure Range 100-1500 PSIG, SEQ3030580
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109379



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-590, Delivery Pressure Range 100-1500 PSIG, SEQ3030590
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109380



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-660, Delivery Pressure Range 100-1500 PSIG, SEQ3030660
In Stock
1


Matheson Model 3030 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3030, CGA-660 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless SteelCGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-2000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2-1/2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3030 model 3030 regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109381



Price: $2,487.75



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, No Inlet, Delivery Pressure Range 100-1500 PSIG, SEQ3030SVNI
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SVNI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109547



Price: $3,497.64



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-320, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV320
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109403



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-326, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV326
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109404



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-330, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV330
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-330 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109405



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-346, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV346
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-346 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109406



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-350, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV350
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109407



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-540, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV540
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109408



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-580, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV580
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109409



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-590, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV590
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109410



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-660, Delivery Pressure Range 100-1500 PSIG, SEQ3030SV660
In Stock
1


Matheson Model 3030SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3030SV, CGA-660 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-1500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3030SV model 3030SV regulator is to be used in applications requiring delivery pressures up to 1500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109411



Price: $3,673.50



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, No Inlet, Delivery Pressure Range 100-2500 PSIG, SEQ3040NI
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass RegulatorSEQ3040NI, No InletA CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application’s needs.Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-StageBoth single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109548



Price: $3,195.87




Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-320, Delivery Pressure Range 100-2500 PSIG, SEQ3040320
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109412



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-326, Delivery Pressure Range 100-2500 PSIG, SEQ3040326
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109413



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-330, Delivery Pressure Range 100-2500 PSIG, SEQ3040330
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-330 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109414



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-346, Delivery Pressure Range 100-2500 PSIG, SEQ3040346
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-346 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109415



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-350, Delivery Pressure Range 100-2500 PSIG, SEQ3040350
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109416



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-540, Delivery Pressure Range 100-2500 PSIG, SEQ3040540
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109417



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-580, Delivery Pressure Range 100-2500 PSIG, SEQ3040580
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P108135



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-590, Delivery Pressure Range 100-2500 PSIG, SEQ3040590
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109418



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator, CGA-660, Delivery Pressure Range 100-2500 PSIG, SEQ3040660
In Stock
1


Matheson Model 3040 Single Stage High Purity, High Delivery Pressure, Nikel Plated Brass Regulator SEQ3040, CGA-660 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-4000 PSIG This is a Matheson Single Stage Nickel Plated Brass regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals, Nickel plated brass bonnet, and a PCTFE seat. This Matheson series 3040 model 3040 regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109419



Price: $3,410.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, No Inlet, Delivery Pressure Range 100-2500 PSIG, SEQ3040SVNI
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SVNI, No Inlet A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109549



Price: $8,103.99



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-320, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV320
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-320 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-320 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109420



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-326, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV326
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-326 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-326 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109421



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-330, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV330
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-330 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-330 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109423



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-346, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV346
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-346 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-346 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109424



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-350, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV350
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-350 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-350 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109425



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-540, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV540
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-540 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-540 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109426



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-580, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV580
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-580 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-580 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109427



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-590, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV590
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-590 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-590 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109428



Price: $8,246.00



Currency: Australian Dollars (AUD)

Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator, CGA-660, Delivery Pressure Range 100-2500 PSIG, SEQ3040SV660
In Stock
1


Matheson Model 3040SV Single Stage High Purity, High Delivery Pressure SS Regulator SEQ3040SV, CGA-660 A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. See CGA Connection Chart.pdf in the downloads section for specific gas types compatible with this Stainless Steel CGA-660 fitting. Regulator Specifications Maximum Inlet Pressure: 3000 psig (20,700 kPa) Maximum Flow Rate: 4600 SCFH (2170 SLPM)(At 2500 psig, N2) Flow Capacity (Cv): 0.06 Operating Temperature: -15°F to 165°F (-26°C to 74°C) Porting (Regulator Body): 1/4” NPT Female Porting Configuration: 2 High, 2 Low Delivery Pressure Range: 100-2500 PSIG Delivery Pressure Gauge: 0-3000 PSIG Cylinder Pressure Gauge: 0-3000 PSIG This is a Matheson Single Stage 316 Stainless Steel regulator with a 1/4 inch MNPT outlet connection and 1/4 inch FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, an outlet needle valve, Teflon & Viton seals and a Nickel plated brass bonnet. This Matheson series 3040SV model 3040SV regulator is to be used in applications requiring delivery pressures up to 2500 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for applications requiring the delivery of gas to manufacturing processes, charging of systems, and purging. This regulator's Viton and Teflon seals are good for most gasses including hydrogen chloride mixtures, however, if the application requires hydrogen sulfide a model using EPR and Vespel seals will be necessary Single-Stage vs. Two-Stage Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator. Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.

Condition: New



Part Number: P109429



Price: $8,246.00



Currency: Australian Dollars (AUD)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com