Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-be
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Adixen 2021C2 Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Agilent Varian Helium Leak Detectors On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nEXT300D TStations On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3
NEW ITEM

Ideal Vacuum 3-Position UHV Pneumatic Operated Gate Valve, Throttled 3rd position, With Solenoid and Reed Sensors, 24VDC, CF 10.0 Inch (DN CF200) Flange, Viton O-ring Standard Seal, SUS304 Body

Condition:
  New
Part Number:
  P1013694
Warranty:
  Against Product Defect

Out of Stock   

Sale: €5,394.00

Ideal Vacuum 3-Position UHV Pneumatic Operated Gate Valve, Throttled 3rd position, With Solenoid and Reed Sensors, 24VDC, CF 10.0 Inch (DN CF200) Flange, Viton O-ring Standard Seal, SUS304 Body 5394
Currency: Euro (Euro)

Description

Ideal Vacuum 3-Position UHV Pneumatic Operated Gate Valve, Throttled 3rd position, With Solenoid and Reed Sensors, 24VDC, CF 10.0 Inch (DN CF200) Flange, Viton O-ring Standard Seal, 1x10-10 mbar, SUS304 Body, 50,000 cycles
CF 10.0 inch Bolt Down Flange with 5/16-24 UNF Threads

This Ideal Vacuum 3-Position Throttle Gate Valve is pneumatically operated with a Conflat CF 10.0 inch (DN CF200) flange. It has a 3rd position that can be set to partially open. It is rated for ultra-high vacuum (UHV) and comes with a standard Viton O-ring seal for the gate and Viton O-ring or OFHC copper gasket for the bonnet with a pneumatic controlled solenoid valve. The valves have a typical life of 50,000 cycles before needing service. They are made with corrosion resistant 304 stainless-steel gates and valve bodies. This 3-position control provides flexibility and precision in maintaining optimal conditions for various vacuum deposition processes, particularly in thin films deposition process chamber systems.

Application in Physical Vapor Deposition Coating Chambers
This 3-position gate valve is designed for dependable High and Ultra- High Vacuum (UHV) applications and are often used in combination with cryo, turbo, and ion high vacuum pumps. It has found increased usage in throttled vacuum processes like PVD magnetron sputtering deposition. In a PVD coating chamber, such as in sputtering systems, a 3-position gate valve is often used to control the connection between the turbo-molecular pump and the main process chamber. These gate valves allow for precise control of the vacuum system and can isolate the pump, protect the chamber, and adjust the pumping speed. The three positions of a typical 3-position gate valve are:

1. Fully Open Position:
Maximum conductance, full turbo pumping speed, used for initial evacuation or when maintaining high vacuum during deposition.

2. Partially Open (Throttling Position):
Purpose: In the partially open position, the gate valve is only partially open, throttling the conductance between the chamber and the turbo pump.Throttling is important when working with reactive gases (e.g., oxygen or nitrogen in reactive sputtering) or when you need to fine-tune the pressure for optimal film growth.

This partially open position is manually set and adjusted one time during installation and can be changed anytime to run a different process condition.

3. Fully Closed Position:
Purpose: In the fully closed position, the gate valve completely isolates the turbo pump from the main chamber. Use Case: This position is used to protect the turbo pump during processes like chamber venting, load-lock chamber sample loading, or when the chamber is being exposed to atmospheric pressure. It prevents contaminants or atmospheric air from entering the turbo pump, which could damage it.

Specifications:
Specifications and features:
  • Material
      • Body
          • SUS304
      • Carriage
          • Linkage type - SUS304
          • Ball type Size under 10” - SUS304
          • Ball type Size above 10”(included) - SUS304, A6061-T6
      • Gate
          • Linkage type - SUS304
          • Ball type Size under 10” - SUS304
          • Ball type Size above 10”(included) - A6061-T6
      • Bellows
          • AM350
  • Life Cycle
      • HV :DN200 - 300,000 cycles
      • UHV :DN200 - 50,000 cycles
  • Helium leak rates at 1 atm differential
      • <2×10-9 mbar·l /sec for O-ring
      • <5×10-10 mbar·l /sec for gasket seal
  • Bake Temperature
      • Open - 200 °C Viton bonnet seal
      • Closed - 150 °C Viton bonnet seal
  • Pressure Range (mbar)
      • HV: 1x10-8 ~ 1000
      • UHV: 1x10-10 ~1000
  • Maximum delta P (mbar)
      • < 30 before opening
  • Standard Seal
      • Gate - Viton O-ring
      • Bonnet - Viton O-ring or OFHC copper gasket
  • Actuator - Pneumatic
  • Compressed air supply
  • Tube connection - 6mm
  • Pressure range - 4-6 Kg/cm2(overpressure)
  • Surface Treatment - Scotch Polished
  • Options
      • Position indicator
      • Pneumatic control solenoid valve
      • Roughing port
      • Other material Gate O-ring seal


Please see the downloads for more information on this gate valve and other related valve configurations.

Brochure


Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.6570