Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-ch
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Edwards nXR Multi Stage Roots Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale Agilent TriScroll Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Agilent Varian 525 Cold Cathode Ion Gauge Tube, Non-Bakeable, KF25. PN: K9234311
Out of Stock


Agilent Varian 525 Cold Cathode Non-Bakeable Ion Gauge Tube, KF25. Agilent Varian Part Number: K9234311, The Agilent Varian 525 Cold Cathode ionization gauge tube measures pressures down to 1 x 10-7 torr with accuracy and reliability. Response time from full to half scale pressure is less than 1 second. The 525 cold cathode gauge is bakeable only to a maximum of 100 °C. When properly maintained, the 525 starts at very low pressures where ordinary cold cathode gauges are difficult to start. Excellent repeatability and improved stability are provided by the linear response below 1 x 10-2 Torr. The cold cathode tube will operate in any orientation. A user suppled RG-58 cable with BNC connector, up to 1000 ft. long, is used to supply high voltage. The tube generates a strong magnetic field, so the user needs to handle the tube with care around other magnetic material. The tube should be protected from direct exposure to mechanical and diffusion pump fluids. Rapid venting of the tube to atmosphere will not cause damage to the 525 gauge tube. Rapid contamination of the 525 cold cathode ion gauge tube will occur if it is operated at pressures above 10-1 Torr for extended periods of time. The 525 Gauge is available with these fittings: 1 in. Tubulation NW25 KF Flange NW40 KF Flange CF 2.75

Condition: New



Part Number: P1012269



Price: Fr. 720.70




Currency: Swiss Franc (CHF)

Agilent Varian 525 Cold Cathode Ion Tube Maintenance Kit
Out of Stock


Agilent Varian 525 Cold Cathode ION Tube Maintenance KitThis Maintenance kit is for a Agilent/Varian 525 Cold Cathode gauge. The 525 Cold Cathode ionization gauge tube, measures pressures down to 1 x 10-7 torr with accuracy and reliability. When properly maintained, the 525 starts at very low pressures where ordinary cold cathode gauges are difficult to start. Excellent repeatability and improved stability are provided by the linear response below 1 x 10-2 Torr (data sheet .pdf below on Agilent 525)

Condition: New



Part Number: P108372



Price: Fr. 495.83




Currency: Swiss Franc (CHF)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com