Keyword Part Number:
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW16 KF16, Body size 4 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water,solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bak-eouts, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 10 B: 4 C: 1.5 D: 3.5 E: 4 F: 3 Liquid Nitrogen Reservoir: 0.75 liter Inlet & Outlet Flange Size: KF16
Condition: New
Part Number: P103849
Price: Fr. 732.72
Ideal Vacuum Vapor-Pumping Ideal Vacuum Angle Liquid Nitrogen Trap Inlet and Outlet NW16 KF16, Body size 4 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series Angle traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These Angle traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 12 B: 4 C: 1.5 D: 6 E: 5.5 F: 3 Liquid Nitrogen Reservoir: 0.75 liter Inlet & Outlet Flange Size: KF-16
Condition: New
Part Number: P103855
Price: Fr. 732.72
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF16, with 0.75 in Ball Drain Valve Body size: 4 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 0.75 liter Welded 0.75 in ball valve
Condition: New
Part Number: P108558
Price: Fr. 868.09
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW25 KF25, Body size 4 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 10.6 B: 4 C: 1.5 D: 3.5 E: 4 F: 3 Liquid Nitrogen Reservoir: 0.75 liter Inlet & Outlet Flange Size: KF25
Condition: New
Part Number: P103850
Price: Fr. 757.56
Ideal Vacuum Vapor-Pumping Angle Liquid Nitrogen Trap Inlet and Outlet NW25 KF25, Body size 4 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series Angle traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These Angle traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 12 B: 4 C: 1.5 D: 6 E: 5.5 F: 3 Liquid Nitrogen Reservoir: 0.75 liter Inlet & Outlet Flange Size: KF25
Condition: New
Part Number: P103856
Price: Fr. 757.56
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF25, with 0.75 in Ball Drain Valve Body size: 4 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 0.75 liter Welded 0.75 in ball valve
Condition: New
Part Number: P108559
Price: Fr. 887.95
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW40 KF40, Body size 4 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 10.6 B: 4 C: 1.5 D: 3.6 E: 4 F: 3 Liquid Nitrogen Reservoir: 0.75 liter Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103848
Price: Fr. 782.39
Ideal Vacuum Vapor-Pumping Angle Liquid Nitrogen Trap Inlet and Outlet NW40 KF40, Body size 4 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series Angle traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These Angle traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 12 B: 4 C: 1.5 D: 6.3 E: 5.5 F: 3 Liquid Nitrogen Reservoir: 0.75 liter Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103857
Price: Fr. 782.39
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF40, with 0.75 in Ball Drain Valve Body size: 4 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 4 inch OD body trap, 5 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 0.75 liter Welded 0.75 in ball valve
Condition: New
Part Number: P108561
Price: Fr. 912.79
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW25, KF-25, Body Size 6 inches OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 14.1 B: 6 C: 1.5 D: 4.6 E: 5.1 F: 5 Liquid Nitrogen Reservoir: 1.60 liter Inlet & Outlet Flange Size: KF-25
Condition: New
Part Number: P107717
Price: Fr. 881.74
Ideal Vacuum Vapor-Pumping Angle Liquid Nitrogen Trap Inlet and Outlet NW25, KF-25, Body Size 6 inches OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 15.5 B: 6 C: 1.5 D: 8.1 E: 6.6 F: 5 Liquid Nitrogen Reservoir: 1.60 liter Inlet & Outlet Flange Size: KF-25
Condition: New
Part Number: P107716
Price: Fr. 881.74
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF25, with 0.75 in Ball Drain ValveBody size: 6 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 1.6 liter Welded 0.75 in ball valve
Condition: New
Part Number: P108560
Price: Fr. 1,061.82
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW40 KF40, Body size 6 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 14.1 B: 6 C: 1.5 D: 4.6 E: 5.1 F: 5 Liquid Nitrogen Reservoir: 1.60 liter Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103851
Price: Fr. 900.37
Ideal Vacuum Vapor-Pumping Angle Liquid Nitrogen Trap Inlet and Outlet NW40 KF40, Body size 6 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series Angle traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These Angle traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 15.5 B: 6 C: 1.5 D: 8.4 E: 6.6 F: 5 Liquid Nitrogen Reservoir: 1.60 liter Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103858
Price: Fr. 900.37
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF40, with 0.75 in Ball Drain ValveBody size: 6 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 1.6 liter Welded 0.75 in ball valve
Condition: New
Part Number: P108562
Price: Fr. 1,074.24
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW50 KF50, Body size 6 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 14.1 B: 6 C: 1.5 D: 4.6 E: 5.1 F: 5 Liquid Nitrogen Reservoir: 1.60 liter Inlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103852
Price: Fr. 925.21
Ideal Vacuum Vapor-Pumping Angle Liquid Nitrogen Trap Inlet and Outlet NW50 KF50, Body size 6 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series Angle traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These Angle traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 15.5 B: 6 C: 1.5 D: 8.9 E: 6.6 F: 5 Liquid Nitrogen Reservoir: 1.60 liter Inlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103859
Price: Fr. 925.21
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF50, with 0.75 in Ball Drain ValveBody size: 6 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 6 inch OD body trap, 8 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 1.6 liter Welded 0.75 in ball valve
Condition: New
Part Number: P108564
Price: Fr. 1,099.08
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW40 KF40, Body size 8 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 8 inch OD body trap, 12 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 16.6 B: 8 C: 2 D: 5.6 E: 6.1 E: 6 Liquid Nitrogen Reservoir: 4.00 liter Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103854
Price: Fr. 1,676.56
Ideal Vacuum Vapor-Pumping Angle Liquid Nitrogen Trap Inlet and Outlet NW40 KF40, Body size 8 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series Angle traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These Angle traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 8 inch OD body trap, 12 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 18 B: 8 C: 2 D: 10.6 E: 7.6 F: 6 Liquid Nitrogen Reservoir: 4.00 liter Inlet & Outlet Flange Size: KF40
Condition: New
Part Number: P103860
Price: Fr. 1,676.56
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF40, with 1 in Ball Drain ValveBody size: 8 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 8 inch OD body trap, 12 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 4 liter Welded 1 in ball valve
Condition: New
Part Number: P108563
Price: Fr. 1,713.82
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet and Outlet NW50 KF50, Body size 8 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 8 inch OD body trap, 12 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 16.6 B: 8 C: 2 D: 5.6 E: 6.1 F: 6 Liquid Nitrogen Reservoir: 4.00 liter Inlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103853
Price: Fr. 1,713.82
Ideal Vacuum Vapor-Pumping Angle Liquid Nitrogen Trap Inlet and Outlet NW50 KF50, Body size 8 inch OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series Angle traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These Angle traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 8 inch OD body trap, 12 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Common Dimensions & Specs: A: 18"B: 8"C: 2" D: 10.6"E: 7.6" F: 6" Liquid Nitrogen Reservoir: 4.00 literInlet & Outlet Flange Size: KF50
Condition: New
Part Number: P103861
Price: Fr. 1,713.82
Ideal Vacuum Vapor-Pumping In-Line Liquid Nitrogen Trap Inlet KF50, with 1 in Ball Drain ValveBody size: 8 in OD Ideal Vacuum Vapor-Pumping Liquid Nitrogen Traps (LNT) Series In-Line traps are capture type traps that collect condensable gas vapors such as water, solvents, etc. as they are being pumped from the vacuum chamber, but before they can intrude into the mechanical pump. These traps collect vapors by utilizing a refrigerant such as liquid nitrogen and should be the foremost choice in high moisture, condensable effluent applications. Without appropriate trapping, condensable vapors can intrude into the mechanical pump, limiting the ultimate base pressure of the pump to unacceptably high levels. These traps actually act as a pump producing lower base pressures and faster pump down. These In-Line traps extend the life of the pump; the hydrocarbon fluid, and minimize maintenance issues. The welded ball valve attachment allows for ease of cleaning and the potential recycling of liquid nitrogen. Isolation valves can also be placed between any capture trap and the work chamber. Isolation valves should always be closed to prevent trapped gases from escaping into the work chamber when warming up the trap, during bake-outs, maintenance cycles, etc. The benefits of putting in service the correct In-Line traps are lower ultimate base pressures, cleaner chambers and extended periods of operation. Each trap offers simple reliable operation, along with high efficiency ratings of better than 99% and when correctly employed practically eliminate hydrocarbon back-streaming issues and are valuable additions to any high vacuum system. Features: Refill timetable for 8 inch OD body trap, 12 hours Two piece clamped body design Removable liquid nitrogen reservoir Traps all condensable vapors Stainless Steel type 304 construction, Viton O-Ring Liquid Nitrogen Reservoir: 4 liter Welded 1 in ball valve
Condition: New
Part Number: P108565
Price: Fr. 1,861.60