Keyword Part Number:
Edwards ELD500 Helium Leak Detector With 3.0 m3/h Internal Wet Oil-Sealed Rotary Vane PumpEdwards Vacuum Part Number D13510906These Edwards ELD 500 helium leak detectors have a built-in internal wet oil-sealed rotary vane pump, pumping speed 3.0 m3/h, are fully automatic and compact, being small enough to place on the bench top. They are their most sensible design yet and offer amazing new features and control options for your facility, lab or classroom. For the ultimate control and customization for any application the ELD500 is your perfect solution for leak detection. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 5 x 10-12 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. They have Edwards Vacuuum part number D13510906. The Edwards ELD 500 helium leak detector offers new features such as: Contains a turbo primary pump and an internal 2.5 CFM (3 m3/hr) wet oil-sealed rotary vane backing roughing pump Quick Start up (< 2 minutes) Helium Pumping Speed 3.1 l/s Extremely fast response DN KF25 Inlet Flange Different reporting options – based on particular application needs Auto Calibration High Sensitivity Flexible application areas Maximum mobility with (optional) wireless or wired remote control ELD 500RC Modular design makes this unit very service friendly Most robust and reliable ion source (extended warranty time) Optional Accessories for The Edwards ELD500 Helium Leak Detector: Wired ELD 500 RC Remote Control PN D13550100 Mobile Trolley Cart D13550630 Helium Spray Gun PN 16555 Premium Helium Spray Probe Kit P1012177 Helium Leak Testing BasicsHelium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a leak, is identified by a rise in the level of helium being analyzed by the machine.Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your pilot knows how to fly.Why Is Helium Superior?While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.Additional reasons why helium is a superior tracer gas: Only modestly present in the atmosphere (roughly 5 parts per million) Flows through cracks 2.7x faster than air Nontoxic Nondestructive Nonexplosive Inexpensive User Friendly Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:Two primary methods of helium leak testing: Spray Probe Sniffer Probe The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.Spray Probe: Provides Maximum SensitivityFor this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.The following are examples of systems that we test using the spray probe technique: A-bar furnaces E-beam systems Laser systems Metal deposition equipment Distillation systems Vacuum systems Sniffer ProbeFor this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process: Storage tanks (both above ground and below) Floating roofs Underground pipelines Underground cables Aseptic systems (flash coolers, heat exchangers, fillers, etc.) Any vessel/line or system that can be pressurized
Condition: New
Part Number: P109796
Price: Kč571,312.97
Regular Price: Kč732,452.49
Edwards ELD500 Helium Leak Detector With 1.8 m3/h Internal Dry Diaphragm Backing PumpEdwards Vacuum Part Number D13520906These Edwards ELD 500 helium leak detectors have a built-in internal dry diaphragm backing pump, pumping speed 1.8 m3/h, are fully automatic and compact, being small enough to place on the bench top. They are their most sensible design yet and offer amazing new features and control options for your facility, lab or classroom. For the ultimate control and customization for any application the ELD500 is your perfect solution for leak detection. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 3 x 10-11 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. They have Edwards Vacuuum part number D13520906. The Edwards ELD 500 helium leak detector offers new features such as: Contains a turbo primary pump and an internal 2.5 CFM (3 m3/hr) wet oil-sealed rotary vane backing roughing pump Quick Start up (< 2 minutes) Helium Pumping Speed 3.1 l/s Extremely fast response DN KF25 Inlet Flange Different reporting options - based on particular application needs Auto Calibration High Sensitivity Flexible application areas Maximum mobility with (optional) wireless or wired remote control ELD 500RC Modular design makes this unit very service friendly Most robust and reliable ion source (extended warranty time) Optional Accessories for The Edwards ELD500 Helium Leak Detector: Wired ELD 500 RC Remote Control PN D13550100 Mobile Trolley Cart D13550630 Helium Spray Gun PN 16555 Premium Helium Spray Probe Kit P1012177 Helium Leak Testing BasicsHelium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a leak, is identified by a rise in the level of helium being analyzed by the machine.Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your pilot knows how to fly.Why Is Helium Superior?While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.Additional reasons why helium is a superior tracer gas: Only modestly present in the atmosphere (roughly 5 parts per million) Flows through cracks 2.7x faster than air Nontoxic Nondestructive Nonexplosive Inexpensive User Friendly Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:Two primary methods of helium leak testing: Spray Probe Sniffer Probe The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.Spray Probe: Provides Maximum SensitivityFor this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.The following are examples of systems that we test using the spray probe technique: A-bar furnaces E-beam systems Laser systems Metal deposition equipment Distillation systems Vacuum systems Sniffer ProbeFor this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process: Storage tanks (both above ground and below) Floating roofs Underground pipelines Underground cables Aseptic systems (flash coolers, heat exchangers, fillers, etc.) Any vessel/line or system that can be pressurized
Condition: New
Part Number: P109798
Price: Kč616,338.69
Regular Price: Kč790,177.76
Edwards ELD500 FLEX Helium Leak Detector, No Internal Backing Pump, External Backing Pump RequiredEdwards Vacuum Part Number D13530000These Edwards ELD 500 Flex helium leak detectors have no internal backing pump. They are typically kitted together with a mobile cart and external rounghing pump, such as, nXDS10i, nXDS15i, or XDS35ie, which allows them to be used as a high-performance mobile model. They are their most sensible design yet and offer amazing new features and control options for your facility, lab or classroom. For the ultimate control and customization for any application the ELD500 is your perfect solution for leak detection. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 5 x 10-12 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. They have Edwards Vacuuum part number D13530000. The Edwards ELD 500 helium leak detector offers new features such as: Contains a turbo primary pump and an internal 2.5 CFM (3 m3/hr) wet oil-sealed rotary vane backing roughing pump Quick Start up (< 2 minutes) Helium Pumping Speed 3.1 l/s Extremely fast response DN KF25 Inlet Flange Different reporting options - based on particular application needs Auto Calibration High Sensitivity Flexible application areas Maximum mobility with (optional) wireless or wired remote control ELD 500RC Modular design makes this unit very service friendly Most robust and reliable ion source (extended warranty time) Optional Accessories for The Edwards ELD500 Helium Leak Detector: Wired ELD 500 RC Remote Control PN D13550100 Mobile Trolley Cart D13550630 Helium Spray Gun PN 16555 Premium Helium Spray Probe Kit P1012177 Helium Leak Testing BasicsHelium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a leak, is identified by a rise in the level of helium being analyzed by the machine.Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your pilot knows how to fly.Why Is Helium Superior?While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.Additional reasons why helium is a superior tracer gas: Only modestly present in the atmosphere (roughly 5 parts per million) Flows through cracks 2.7x faster than air Nontoxic Nondestructive Nonexplosive Inexpensive User Friendly Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:Two primary methods of helium leak testing: Spray Probe Sniffer Probe The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.Spray Probe: Provides Maximum SensitivityFor this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.The following are examples of systems that we test using the spray probe technique: A-bar furnaces E-beam systems Laser systems Metal deposition equipment Distillation systems Vacuum systems Sniffer ProbeFor this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process: Storage tanks (both above ground and below) Floating roofs Underground pipelines Underground cables Aseptic systems (flash coolers, heat exchangers, fillers, etc.) Any vessel/line or system that can be pressurized
Condition: New
Part Number: P109800
Price: Kč543,756.09
Regular Price: Kč697,123.11
Edwards ELD500 FLEX Helium Leak Detector Kit With nXDS10i Dry Scroll Backing Pump And Mobile Cart Kit.Kit Includes HLD500 Flex (PN: D13530000), nXDS10i (PN: A73601983) and Mobile Cart (PN: D13550630). These Edwards ELD 500 Flex helium leak detector high-performance mobile kit includes nXDS10i (11.4 m3/h) dry scroll backing pump.They are their most sensible design yet and offer amazing new features and control options for your facility, lab or classroom. For the ultimate control and customization for any application the ELD500 is your perfect solution for leak detection. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 5 x 10-12 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. This complete kit includes: HLD500 Flex (PN D13530000), nXDS10i (PN A73601983), Mobile Cart (PN D13550630), roughing pump mounting hardware, bellows hose, centering rings, and clamps. The Edwards ELD 500 helium leak detector offers new features such as: Contains a turbo primary pump and an internal 6.7 CFM (11.4 m3/h) nXDS10i dry scroll roughing pump Quick Start up (< 2 minutes) Helium Pumping Speed 3.1 l/s Extremely fast response DN KF25 Inlet Flange Different reporting options - based on particular application needs Auto Calibration High Sensitivity Flexible application areas Maximum mobility with (optional) wireless or wired remote control ELD 500RC Modular design makes this unit very service friendly Most robust and reliable ion source (extended warranty time) Optional Accessories for The Edwards ELD500 Helium Leak Detector: Wired ELD 500 RC Remote Control PN D13550100 Mobile Trolley Cart D13550630 Helium Spray Gun PN 16555 Premium Helium Spray Probe Kit P1012177 Helium Leak Testing BasicsHelium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a "leak," is identified by a rise in the level of helium being analyzed by the machine.Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your "pilot" knows how to fly.Why Is Helium Superior?While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.Additional reasons why helium is a superior tracer gas: Only modestly present in the atmosphere (roughly 5 parts per million) Flows through cracks 2.7x faster than air Nontoxic Nondestructive Nonexplosive Inexpensive User Friendly Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:Two primary methods of helium leak testing: Spray Probe Sniffer Probe The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.Spray Probe: Provides Maximum SensitivityFor this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.The following are examples of systems that we test using the spray probe technique: A-bar furnaces E-beam systems Laser systems Metal deposition equipment Distillation systems Vacuum systems Sniffer ProbeFor this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process: Storage tanks (both above ground and below) Floating roofs Underground pipelines Underground cables Aseptic systems (flash coolers, heat exchangers, fillers, etc.) Any vessel/line or system that can be pressurized
Condition: New
Part Number: P1012211
Price: Kč772,194.99
Regular Price: Kč989,993.60
Edwards ELD500 FLEX Helium Leak Detector Kit With nXDS15i Dry Scroll Backing Pump and Mobile Cart KitKit Includes HLD500 Flex (PN: D13530000), nXDS15i (PN: A73701983) and Mobile Cart (PN: D13550630). These Edwards ELD 500 Flex helium leak detector high-performance mobile kit includes nXDS15i (15.1 m3/h) dry scroll backing pump.They are their most sensible design yet and offer amazing new features and control options for your facility, lab or classroom. For the ultimate control and customization for any application the ELD500 is your perfect solution for leak detection. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 5 x 10-12 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. This complete kit includes: HLD500 Flex (PN D13530000), nXDS15i (PN A73701983), Mobile Cart (PN D13550630), roughing pump mounting hardware, bellows hose, centering rings, and clamps. The Edwards ELD 500 helium leak detector offers new features such as: Contains a turbo primary pump and an internal 8.9 CFM (15.1 m3/h) nXDS15i dry scroll roughing pump Quick Start up (< 2 minutes) Helium Pumping Speed 3.1 l/s Extremely fast response DN KF25 Inlet Flange Different reporting options - based on particular application needs Auto Calibration High Sensitivity Flexible application areas Maximum mobility with (optional) wireless or wired remote control ELD 500RC Modular design makes this unit very service friendly Most robust and reliable ion source (extended warranty time) Optional Accessories for The Edwards ELD500 Helium Leak Detector: Wired ELD 500 RC Remote Control PN D13550100 Mobile Trolley Cart D13550630 Helium Spray Gun PN 16555 Premium Helium Spray Probe Kit P1012177 Helium Leak Testing BasicsHelium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a leak, is identified by a rise in the level of helium being analyzed by the machine.Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your pilot knows how to fly.Why Is Helium Superior?While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.Additional reasons why helium is a superior tracer gas: Only modestly present in the atmosphere (roughly 5 parts per million) Flows through cracks 2.7x faster than air Nontoxic Nondestructive Nonexplosive Inexpensive User Friendly Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:Two primary methods of helium leak testing: Spray Probe Sniffer Probe The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.Spray Probe: Provides Maximum SensitivityFor this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.The following are examples of systems that we test using the spray probe technique: A-bar furnaces E-beam systems Laser systems Metal deposition equipment Distillation systems Vacuum systems Sniffer ProbeFor this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process: Storage tanks (both above ground and below) Floating roofs Underground pipelines Underground cables Aseptic systems (flash coolers, heat exchangers, fillers, etc.) Any vessel/line or system that can be pressurized
Condition: New
Part Number: P1012212
Price: Kč808,756.67
Regular Price: Kč1,036,867.65
Edwards ELD500 FLEX Helium Leak Detector Kit With nXDS35ie Dry Scroll Backing Pump And Mobile Cart KitKit Includes HLD500 Flex (PN D13530000), nXDS35ie (PN A73003983) and Mobile Cart (PN D13550630)These Edwards ELD 500 Flex helium leak detector high-performance mobile kit includes nXDS35ie (35 m3/h) dry scroll backing pump.They are their most sensible design yet and offer amazing new features and control options for your facility, lab or classroom. For the ultimate control and customization for any application the ELD500 is your perfect solution for leak detection. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 5 x 10-12 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. They operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. This complete kit includes: HLD500 Flex (PN D13530000), nXDS35ie (PN A73003983), Mobile Cart (PN D13550630), roughing pump mounting hardware, bellows hose, centering rings, and clamps. The Edwards ELD 500 helium leak detector offers new features such as: Contains a turbo primary pump and a huge external 21 CFM (35 m3/h) nXDS35ie dry scroll roughing pump Quick Start up (< 2 minutes) Helium Pumping Speed 3.1 l/s Extremely fast response DN KF25 Inlet Flange Different reporting options - based on particular application needs Auto Calibration High Sensitivity Flexible application areas Maximum mobility with (optional) wireless or wired remote control ELD 500RC Modular design makes this unit very service friendly Most robust and reliable ion source (extended warranty time) Optional Accessories for The Edwards ELD500 Helium Leak Detector: Wired ELD 500 RC Remote Control PN D13550100 Mobile Trolley Cart D13550630 Helium Spray Gun PN 16555 Premium Helium Spray Probe Kit P1012177 Helium Leak Testing BasicsHelium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a leak, is identified by a rise in the level of helium being analyzed by the machine.Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your pilot knows how to fly.Why Is Helium Superior?While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.Additional reasons why helium is a superior tracer gas: Only modestly present in the atmosphere (roughly 5 parts per million) Flows through cracks 2.7x faster than air Nontoxic Nondestructive Nonexplosive Inexpensive User Friendly Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:Two primary methods of helium leak testing: Spray Probe Sniffer Probe The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.Spray Probe: Provides Maximum SensitivityFor this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.The following are examples of systems that we test using the spray probe technique: A-bar furnaces E-beam systems Laser systems Metal deposition equipment Distillation systems Vacuum systems Sniffer ProbeFor this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process: Storage tanks (both above ground and below) Floating roofs Underground pipelines Underground cables Aseptic systems (flash coolers, heat exchangers, fillers, etc.) Any vessel/line or system that can be pressurized
Condition: New
Part Number: P1012215
Price: Kč921,476.07
Regular Price: Kč1,181,379.67
EDWARDS Mobile Trolley Cart for the ELD500 Helium Leak Detector. Edwards Part Number: PN D135500630. This is an EDWARDS Mobile Trolley Cart for the ELD500 Helium Leak Detector. For those who want to pair the Leak detector with a larger backing pump or further increase the mobility then the ELD500 cart is the accessory for you. When trolley mounted the leak detector is at a comfortable working height and provides a platform on the bottom to store a larger backing pump and a space to mount a large helium bottle for testing. Places the ELD500 at a comfortable working height and eables easy movement around any environment. The overall dimensions (HxWxD) 1024 x 999 x 525 mm. 40 x 39.3 x 20.6 in. Room for helium gas canister to be strapped to the side and room for auxiliary backing pump beneath. This is an ideal partner for the ELD500 Flex when paired with an Edwards primary roughing pump. (This is the Cart only, Leak Detector sold separately) We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see the DOWNLOADS.
Condition: New
Part Number: P109818
Price: Kč50,211.16
Regular Price: Kč52,853.85
EDWARDS WIRED ELD 500 RC Remote Control, to be used with the Edwards ELD500 Helium Leak Detector PN D13550100 This is a WIRED ELD 500 RC Remote Control, to be used with the Edwards ELD500 Helium Leak Detector. This allows you to test large objects. The ELD500 RC wireless remote has a colored display, touch screen, internal trigger limit and acoustic warning signal. It can also export data to a PC and can be attached to the ELD500 Helium leak detector when not in use. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109801
Price: Kč76,084.14
EDWARDS Extension Cable 8m, for ELD 500 RC Wired Remote Control for Edwards ELD500 Helium Leak Detector PN 14022 This is a EDWARDS Extension Cable 8m, for ELD 500 RC Wired Remote Control for Edwards ELD500 Helium Leak Detector PN 14022. This is an extension cable only, Remote Control not included. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109805
Price: Kč6,602.54
Edwards & Leybold Helium Spray Gun for ELD500, Phoenix Quardo & Vario Helium Leak Detectors, PN 16555 This is a Edwards & Leybold Helium Spray Gun for Phoenix Quardo & Vario Helium Leak Detectors. It allows precision leak detection and control of helium flow which is essential in effective leak detection. Enables the user to pinpoint the leak in vacuum mode simple operation. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109821
Price: Kč14,248.73
Ideal Vacuum PREMIUM Helium Spray Gun Probe Kit with 1 Liter High Pressure Cylinder, Regulator, Refill Adapter, and Quick Connect Fittings. This Ideal Vacuum premium helium spray probe kit includes a lightweight, aluminum, refillable high pressure cylinder with an adjustable, precise output regulator. The helium flow rate can be adjusted between 0 and 0.1 Standard Liters Per Minute (SLPM) on the cylinder’s detacheable regulator (1-5 psig). The reservoir cylinder is 3” diameter x 11” tall, with a volume of 1000 cc. The cylinder has a burst pressure rating of 1800 psi. We recommend it be filled normally to about 500 psig, more than enough for numerous leak detection procedures. (Do Not Exceed the Cylinder’s Rated Pressure.) In addition to being extremely portable with its refillable cylinder, this premium helium spray gun probe kit also includes a refill adapter for refilling the cylinder from a larger helium bottle, 10 ft. flexible supply hose, a gun-mounted, 1/4 turn shutoff valve, a 4" rigid stainless steel probe tip, and an 8" long flexible probe tip, all packaged in a durable, foam lined storage and carrying case. This kit is designed for use in maintenance or production leak detection applications. The supply hose has C10 quick connect fittings on either end to connect the cylinder’s regulator to the spray gun. Download the Helium Spray Probe User Guide and the Cylinder Refilling Instruction Manual for more information.
Condition: New
Part Number: P1012177
Price: Kč25,583.78
Regular Price: Kč26,930.30
EDWARDS Standard Sniffer line 4m, to be used with the Edwards ELD500 Helium Leak Detector PN D13550300 This is an EDWARDS robust sniffer with 4m length and flange connection to the leak detector. Red and green status LED and Zero push button directly at the sniffer. For the exact localization of leaks and leak rate calculation of the measured leak. Local leak tests at serial parts, chambers, systems etc. Suited for all kinds of hollow objects exposed to overpressures. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109808
Price: Kč56,784.93
EDWARDS Extended Sniffer line 5m, to be used with the Edwards ELD500 Helium Leak Detector PN D13550300 This is an EDWARDS robust sniffer with 5m length and flange connection to the leak detector. Red and green status LED and Zero push button directly at the sniffer. For the exact localization of leaks and leak rate calculation of the measured leak. Local leak tests at serial parts, chambers, systems etc. Suited for all kinds of hollow objects exposed to overpressures. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109809
Price: Kč54,204.32
EDWARDS Extended Sniffer line 20m, to be used with the Edwards ELD500 Helium Leak Detector PN 14009 This is an EDWARDS robust sniffer with 20m length and flange connection to the leak detector. Red and green status LED and Zero push button directly at the sniffer. For the exact localization of leaks and leak rate calculation of the measured leak. Local leak tests at serial parts, chambers, systems etc. Suited for all kinds of hollow objects exposed to overpressures. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109810
Price: Kč49,863.83
EDWARDS Extended Sniffer line 50m, to be used with the Edwards ELD500 Helium Leak Detector PN 12183 This is an EDWARDS robust sniffer with 50m length and flange connection to the leak detector. Red and green status LED and Zero push button directly at the sniffer. For the exact localization of leaks and leak rate calculation of the measured leak. Local leak tests at serial parts, chambers, systems etc. Suited for all kinds of hollow objects exposed to overpressures. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109811
Price: Kč81,165.06
EDWARDS ELD500 SL-Extended SL Sniffer Line Interface, for ELD500 Helium Leak Detector PN D13550200 This is an EDWARDS SL Extended Sniffer Line. When utilising the sniffer mode the ELD500 SL Interface is the essential accessory. And with the ELD500 Extended SL interface you get the ability to further increase the response time of the unit via the integrated gas pump. Zero point on extender interface. Ready/leak LED indicator on the probe itself. Ruggedized sniffer tip increases product life. For the exact localization of leaks and leak rate calculation of the measured leak. Local leak tests at serial parts, chambers, systems etc. Suited for all kinds of hollow objects exposed to overpressures. We offer a large variety of vacuum fittings, hoses, vacuum gauges, sensors/transducers and accessories sold separately on this website. Call us for a quote (505) 872-0037. For a complete instruction manual on the Edwards ELD500 see Downloads to the left.
Condition: New
Part Number: P109813
Price: Kč121,886.49
Edwards ELD500 Helium Leak Detector Auto-Start Cable for a Connected Backing Pump. Edwards Vacuum Part Number D13550631. This Edwards cable enables the ELD500 Helium Leak Detector to auto-start a connected backing pump, including an nXDS dry scroll backing pump. The Edwards ELD 500 helium leak detector is fully automatic and compact enough to place on the bench top. At the push of a button the ELD500 can easily be set to work in either vacuum mode for precise measurement of leak rate or sniffer mode for identifying leak location. The minimum detectable leak rate available for this unit in vacuum mode is 5 x 10-12 mbar l/s and in sniffer mode 7 x 10-9 mbar l/s. The inlet flange on the Edwards ELD500 is DN KF25 and it comes standard with a TL7 internal calibrated leak and certificate of calibration. The Edwards ELD 500 helium leak detector operating instruction manual and product brochure can be downloaded in PDF format below. It operates on 1-phase 100-120 VAC 50/60 Hz and we offer optional accessories, such as, a trolley, transport case, remote control, spray gun, sniffer etc. Available Options for The Edwards ELD500 Helium Leak Detector: Wired ELD 500 RC Remote Control PN D13550100 Mobile Trolley Cart D13550630 Helium Spray Gun PN 16555 Premium Helium Spray Probe Kit P1012177 Helium Leak Testing BasicsHelium mass spectrometry, or helium leak testing, is a highly precise means of leak detection. This technology was first developed for the Manhattan Project during World War II to locate extremely small leaks in the gas diffusion process.At the heart of helium leak testing is a complex piece of equipment called a helium mass spectrometer. Quite simply, this machine is used to analyze air samples (which are introduced into the machine via vacuum pumps) and provides a quantitative measurement of the amount of helium present in the sample. In practice, a "leak," is identified by a rise in the level of helium being analyzed by the machine.Helium leak testing can identify extremely small leaks. For example, our equipment can detect a leak so small that it would emit just two cubic centimeters of helium (or the amount equal to two sugar cubes) in 320 years. While very few applications require this level of precision, this example serves to highlight the accuracy possible with this process.While helium leak detection may appear to be a simple procedure, the process involves a combination of both art and science. The user must ensure the equipment is functioning properly and the process is highly dependant upon the user’s experience. Consider this analogy: while anyone with enough money can buy an airplane, learning how to fly one takes a lot of practice. The same is true with helium leak detection-make sure your "pilot" knows how to fly.Why Is Helium Superior?While many gases are used in leak detection, helium’s qualities provide for superior testing. Having an AMU (Atomic Mass Unit) of only 4, helium is the lightest inert gas. Only hydrogen, with an AMU of 2, is lighter than helium. However, due the hydrogen’s explosive potential it is rarely used.Additional reasons why helium is a superior tracer gas: Only modestly present in the atmosphere (roughly 5 parts per million) Flows through cracks 2.7x faster than air Nontoxic Nondestructive Nonexplosive Inexpensive User Friendly Due to these attributes, and its high sensitivity, helium leak testing has gained broad acceptance in a wide range of leak testing applications. Helium Leak Testing’s two primary testing modes while there are a variety of testing procedures, in general there are:Two primary methods of helium leak testing: Spray Probe Sniffer Probe The choice between these two modes is based on both the size of the system being tested, as well as, the level of sensitivity required.Spray Probe: Provides Maximum SensitivityFor this technique, the leak detector is hooked directly to the system under test and the inside of the system is evacuated. Once an acceptable vacuum is achieved, helium is sprayed discreetly on the outside of the system, with particular attention being paid to any suspect locations. Any leaks in the system, including defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect will allow helium to pass and be readily detected by the machine. The source of any leaks can then be accurately pinpointed and repaired.The spray probe process is used to achieve the highest level of sensitivity. The equipment being used dictates the maximum sensitivity achievable; in Jurva Leak Testing’s case it is 2x10-10 std cc/sec. This technique does require that the system being tested is relatively leak tight prior to testing, as an ample vacuum is required for testing. However, by using special throttling devices a gross test can typically be performed. The gross test should eliminate any major leaks, permitting the use of increased sensitivity.The following are examples of systems that we test using the spray probe technique: A-bar furnaces E-beam systems Laser systems Metal deposition equipment Distillation systems Vacuum systems Sniffer ProbeFor this technique, helium is purged throughout the inside of system being tested. Due to the innate properties of helium it readily migrates throughout the system and in its attempt to escape penetrates any imperfections, including: defective welds (caused by cracks, pin holes, incomplete welds, porosity, etc.), flawed or missing gaskets, leaks due to loose clamps, or any other defect. The system’s exterior is then scanned by using a probe attached to the leak tester. Any leaks will result in an increased level of helium nearest the source and be readily detected. Leak sources can then be pinpointed, providing the opportunity for immediate repair and retest.Unlike the spray probe technique, this process is very flexible and can be adapted to meet the needs of any virtually any system in which helium can be injected. There is no practical size limitation. The sniffer probe technique is not as sensitive as the spray probe process, however, due to the amount of helium present in the air (approximately 5 ppm). The maximum sensitivity achievable under this procedure is approximately 1x10-6 std cc/sec. Nevertheless, this process is vastly superior to other traditional leak testing methods, such as: bubble testing, acoustic emission, liquid penetrant or vacuum box testing.The following list is an example of systems that Jurva Leak Testing has tested using the sniffer probe process: Storage tanks (both above ground and below) Floating roofs Underground pipelines Underground cables Aseptic systems (flash coolers, heat exchangers, fillers, etc.) Any vessel/line or system that can be pressurized
Condition: New
Part Number: P1012353
Price: Kč6,232.44