Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-cz
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Edwards nEXT300D TStations On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Adixen 2021C2 Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Pfeiffer HiPace 80 Turbo Pump with TC 110 Drive Unit DN40 KF-40 Inlet Flange 41 l/s Pumping Speed Air-or Water-Cooled, PN: PM P03 942 A
In Stock
22


Pfeiffer HiPace 80 Turbo Pump with TC 110 Drive Unit DN40 KF-40 Inlet Flange 41 l/s Pumping Speed Air-or Water-Cooled. Pfeiffer Part Number: PM P03 942 A. Pfeiffer HiPace 80 turbomolecular high-vacuum pumps with a DN40 KF-40 inlet flange have a pumping speed of 41 liters per second (l/s) and an ultimate pressure of 7.5 x 10-8 Torr. This Pfeiffer HiPace 80 pump comes with an integrated TC 110 drive unit side-mounted to the pump, and has an ISO KF-16 exhaust foreline flange. The pump can be mounted in any orientation. 24 VDC input power at a maximum of 110 Watts is required. This HiPace 80 turbo pump with KF40 inlet and TC 110 drive unit has Pfeiffer part number: PM P03 942 A. The included TC 110 drive unit is a compact onboard controller which includes a single X3 (15-pin D-Sub) connector for supplying pump power, RS485 communications and accessory ports (to control either an air-cooling fan or solenoid vent valve). For Original Equipment Manufacturer (OEM) and system integration applications, all that is needed to start the pump is a suitable 24 VDC power supply along with start/stop logic. For laboratory applications we recommend the 200 Watt Pfeiffer OmniControl 200 controller which can both supply power and control the pump. The OmniControl 200 is a bench top or rack mountable remote user interface/power source, which communicates with and provides full monitoring and control of Pfeiffer HiPace series turbo pumps through RS485. Alternatively, the more economical Pfeiffer DCU 110 controller may also be used to supply power and control the pump. To interconnect the pump and a controller, and breakout the RS485 connector and accessory ports, use Pfeiffer cable part number P103335 or P1011168. We offer a variety of optional accessories, including the OmniControl 200 and DCU 110 pump controllers, inlet screens, forced air-cooling and water-cooling kits, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only). Pfeiffer HiPace 80 Turbo Pump with KN-40 Inlet and TC 110 Drive Unit Specifications: Part Number: PM P03 942 A Inlet Flange: KF 40 Base Pressure: 7.5 x 10-8 Torr Operating Speed: 90,000 RPM Mounting orientation: Any Pumping Speed: 41 l/s Cooling Method Standard: Convection Cooling Method Optional: Forced Air or Water (75 l/h, 15 to 25 °C) Exhaust Flange: KF-16, G 1/4” (BSPP) Venting Connection: G 1/8” (BSPP) Integral Controller: TC 110 Drive Unit Operating Voltage: 24 VDC Maximum Power: 110 Watts Run-up Time: 1.7 Min. Interfaces: RS485, Remote, through 15-Pin D-Sub X3 Connector Accessory Ports: Two through 15-pin D-Sub X3 Connector Input Power: Through 15-pin D-Sub X3 Connector Operating Mode Display: 3 LEDs Recommended Roughing Pump: HiScroll 6 Dry Scroll Pump The Pfeiffer Vacuum HiPace series of turbopumps feature a unique rotor design with proven hybrid bearings. HiPace pumps achieve high pumping speeds and high gas throughput as well as high compression for light gases. HiPace pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures and offer enhanced pumping speeds across all gas species. HiPace hybrid bearings are a combination of a ceramic ball bearing on the fore vacuum side and a permanent magnetic radial bearing on the high-vacuum side. This bearing technology does not require electromagnets and has an extended service life with typical maintenance intervals of approximately 4 years. In addition to enhanced performance, all HiPace turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decreases downtime. Pfeiffer HiPace pumps with a Conflat CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat-flanged HiPace pumps can be baked up to 120 °C if the turbo is water cooled. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments The pump instruction manual and Pfeiffer HiPace pump product brochures are available in the downloads.

Condition: New



Part Number: P105122



Price: Kč142,501.65


Regular Price: Kč173,782.50




Currency: Czech Koruna (CZK)

Pfeiffer HiPace 80 Turbo Pump with TC 110 Drive Unit DN63 ISO-K 63 Inlet Flange 67 l/s Pumping Speed Air-or Water-Cooled, PN: PM P03 940 A
In Stock
23


Pfeiffer HiPace 80 Turbo Pump with TC 110 Drive Unit DN63 ISO-K 63 Inlet Flange 67 l/s Pumping Speed Air-or Water-Cooled. Pfeiffer Part Number: PM P03 940 A. Pfeiffer HiPace 80 turbomolecular high-vacuum pumps with a DN63 ISO-K inlet flange have a pumping speed of 67 liters per second (l/s) and an ultimate pressure of 7.5 x 10-8 Torr. This Pfeiffer HiPace 80 pump comes with an integrated TC 110 drive unit side-mounted to the pump, and has an ISO KF-16 exhaust foreline flange. The pump can be mounted in any orientation. 24 VDC input power at a maximum of 110 Watts is required. This HiPace 80 turbo pump with ISO-K 63 inlet and TC 110 drive unit has Pfeiffer part number: PM P03 940 A. The included TC 110 drive unit is a compact onboard controller which includes a single X3 (15-pin D-Sub) connector for supplying pump power, RS485 communications and accessory ports (to control either an air-cooling fan or solenoid vent valve). For Original Equipment Manufacturer (OEM) and system integration applications, all that is needed to start the pump is a suitable 24 VDC power supply along with start/stop logic. For laboratory applications we recommend the 200 Watt Pfeiffer OmniControl 200 controller which can both supply power and control the pump. The OmniControl 200 is a bench top or rack mountable remote user interface/power source, which communicates with and provides full monitoring and control of Pfeiffer HiPace series turbo pumps through RS485. Alternatively, the more economical Pfeiffer DCU 110 controller may also be used to supply power and control the pump. To interconnect the pump and a controller, and breakout the RS485 connector and accessory ports, use Pfeiffer cable part number P103335 or P1011168. We offer a variety of optional accessories, including the OmniControl 200 and DCU 110 pump controllers, inlet screens, forced air-cooling and water-cooling kits, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only). Pfeiffer HiPace 80 Turbo Pump with ISO-K 63 Inlet and TC 110 Drive Unit Specifications: Part Number: PM P03 940 A Inlet Flange: ISO-63K (flanges connect with double-claw clamps) Base Pressure: 7.5 x 10-8 Torr Operating Speed: 90,000 RPM Mounting orientation: Any Pumping Speed: 67 l/s Cooling Method Standard: Convection Cooling Method Optional: Forced Air or Water (75 l/h, 15 to 25 °C) Exhaust Flange: KF-16, G 1/4” (BSPP) Venting Connection: G 1/8” (BSPP) Integral Controller: TC 110 Drive Unit Operating Voltage: 24 VDC Maximum Power: 110 Watts Run-up Time” 1.7 Min. Interfaces: RS485, Remote, through 15-Pin D-Sub X3 Connector Accessory Ports: Two through 15-Pin D-Sub X3 Connector Input Power: Through 15-Pin D-Sub X3 Connector Operating Mode Display: 3 LEDs Recommended Roughing Pump: HiScroll 6 Dry Scroll Pump The Pfeiffer Vacuum HiPace series of turbopumps feature a unique rotor design with proven hybrid bearings. HiPace pumps achieve high pumping speeds and high gas throughput as well as high compression for light gases. HiPace pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures and offer enhanced pumping speeds across all gas species. HiPace hybrid bearings are a combination of a ceramic ball bearing on the fore vacuum side and a permanent magnetic radial bearing on the high-vacuum side. This bearing technology does not require electromagnets and has an extended service life with typical maintenance intervals of approximately 4 years. In addition to enhanced performance, all HiPace turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decreases downtime. Pfeiffer HiPace pumps with a Conflat CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat-flanged HiPace pumps can be baked up to 120 °C if the turbo is water cooled. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments The pump instruction manual and Pfeiffer HiPace pump product brochures are available in the downloads.

Condition: New



Part Number: P103317



Price: Kč142,501.65


Regular Price: Kč173,782.50




Currency: Czech Koruna (CZK)

Pfeiffer HiPace 80 Turbo Pump with TC 110 Drive Unit Conflat CF 4.5 In. Inlet Flange 67 l/s Pumping Speed Air-or Water-Cooled, PN: PM P03 941 A
In Stock
17


Pfeiffer HiPace 80 Turbo Pump with TC 110 Drive Unit Conflat CF 4.5 In. Inlet Flange 67 l/s Pumping Speed Air-or Water-Cooled. Pfeiffer Part Number: PM P03 941 A. Pfeiffer HiPace 80 turbomolecular high-vacuum pumps with a Conflat CF 4.5 inch inlet flange have a pumping speed of 67 liters per second (l/s) and an ultimate pressure of 3.5 x 10-10 Torr. This Pfeiffer HiPace 80 pump comes with an integrated TC 110 drive unit side-mounted to the pump, and has an ISO KF-16 exhaust foreline flange. The pump can be mounted in any orientation. 24 VDC input power at a maximum of 110 Watts is required. This HiPace 80 turbo pump with CF 4.5" inlet and TC 110 drive unit has Pfeiffer part number: PM P03 941 A. The included TC 110 drive unit is a compact onboard controller which includes a single X3 (15-pin D-Sub) connector for supplying pump power, RS485 communications and accessory ports (to control either an air-cooling fan or solenoid vent valve). For Original Equipment Manufacturer (OEM) and system integration applications, all that is needed to start the pump is a suitable 24 VDC power supply along with start/stop logic. For laboratory applications we recommend the 200 Watt Pfeiffer OmniControl 200 controller which can both supply power and control the pump. The OmniControl 200 is a bench top or rack mountable remote user interface/power source, which communicates with and provides full monitoring and control of Pfeiffer HiPace series turbo pumps through RS485. Alternatively, the Pfeiffer DCU 110 controller may also be used to supply power and control the pump. To interconnect the pump and controller, and breakout the RS485 connector and accessory ports, use Pfeiffer cable part number P103335 or P1011168. We offer a variety of optional accessories, including the OmniControl 200 and DCU 110 pump controllers, inlet screens, forced air-cooling and water-cooling kits, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only). Pfeiffer HiPace 80 Turbo Pump with Conflat CF 4.5" Inlet and TC 110 Drive Unit Specifications: Part Number: PM P03 941 A Inlet Flange: Conflat CF 4.5 Inch Base Pressure: 3.5 x 10-10 Torr Maximum Bakeout Temperature at High Vacuum Flange: 120 °C Operating Speed: 90,000 RPM Mounting orientation: Any Pumping Speed: 67 l/s Cooling Method Standard: Convection Cooling Method Optional: Forced Air or Water (75 l/h, 15 to 25 °C) Exhaust Flange: KF-16, G 1/4” (BSPP) Venting Connection: G 1/8” (BSPP) Integral Controller: TC 110 Drive Unit Operating Voltage: 24 VDC Maximum Power: 110 Watts Run-up Time: 1.7 Min Interfaces: RS485, Remote, through 15-Pin D-Sub X3 Connector Accessory Ports: Two through 15-Pin D-Sub X3 Connector Input Power: Through 15-Pin D-Sub X3 Connector Recommended Roughing Pump: HiScroll 6 Dry Scroll Pump The Pfeiffer Vacuum HiPace series of turbopumps feature a unique rotor design with proven hybrid bearings. HiPace pumps achieve high pumping speeds and high gas throughput as well as high compression for light gases. HiPace pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures and offer enhanced pumping speeds across all gas species. HiPace hybrid bearings are a combination of a ceramic ball bearing on the fore vacuum side and a permanent magnetic radial bearing on the high-vacuum side. This bearing technology does not require electromagnets and has an extended service life with typical maintenance intervals of approximately 4 years. In addition to enhanced performance, all HiPace turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decreases downtime. Pfeiffer HiPace pumps with a Conflat CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat-flanged HiPace pumps can be baked up to 120 °C if the turbo is water cooled. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments The pump instruction manual and Pfeiffer HiPace pump product brochures are available in the downloads.

Condition: New



Part Number: P103316



Price: Kč142,644.03


Regular Price: Kč173,956.28




Currency: Czech Koruna (CZK)

Pfeiffer OmniControl 200 Turbo Pump Display Control Unit and Power Supply 220W 24 VDC, Dual Gauge. PN: PE D50 110 0
In Stock
5


Pfeiffer OmniControl 200 Turbo Pump Display Control Unit and Power Supply 220W 24 VDC, Dual Gauge. Pfeiffer Part Number: PE D50 110 0. (This controller replaces the Pfeiffer TPG 362 Dual Gauge PN: PT G28 290) The Pfeiffer OmniControl 200 turbo pump controller can be bench top or rack mounted and is designed to operate Pfeiffer HiPace 80 and HiPace 300H turbo pumps that have the integrated TC110 drive unit. The OmniControl 200 supplies 24 VDC at a maximum of 200 Watts to the TC 110 electronic drive unit which then powers the pump. The required connection cable between the OmniControl 200 and TC 110 is part number P103335 (2 M8 ports) or P1011168 (3 M8 ports) and is not included. The connection cable not only supplies power to the pump it also has M8 ports for connecting optional accessories such as a forced air-cooling kit, a solenoid vent valve, and/or a sealing gas valve. Input power to the OmniControl 200 is 115/230 VAC and a standard C14 rear-mounted socket is provided for mains power entry (power cord not included, part number P103361). This OmniControl 200 turbo pump display control unit and power supply has Pfeiffer part number PE D50 100 0. The OmniControl 200 can control all the main parameters of the turbo pump via a 3 meter long RS485 interface cable (part number P1012287, not included). This unit can also be used to operate and display pressure readings from Pfeiffer Active gauges if the optional Gauge/IO module is installed. Pfeiffer turbo pump accessories, including inlet screens, forced air-cooling and water-cooling kits, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only) are available in other listings. The instruction manual for the OmniControl 200 controller and related documentation for Pfeiffer HiPace turbo pump products is available in the downloads.

Condition: New



Part Number: P1012694



Price: Kč84,283.31


Regular Price: Kč88,719.44




Currency: Czech Koruna (CZK)

Pfeiffer OmniControl 200 Turbo Pump Display Control Unit and Power Supply 220W 24 VDC. PN: PE D50 100 0
Out of Stock
Expecting 15
Anticipated Arrival 9 on 2024-12-20


Pfeiffer OmniControl 200 Turbo Pump Display Control Unit and Power Supply 220W 24 VDC. Pfeiffer Part Number: PE D50 100 0. (This controller replaces the discontinued TPG 361 PN: PT G28 040). The Pfeiffer OmniControl 200 turbo pump controller can be bench top or rack mounted and is designed to operate Pfeiffer HiPace 80 and HiPace 300H turbo pumps that have the integrated TC110 drive unit. The OmniControl 200 supplies 24 VDC at a maximum of 200 Watts to the TC 110 electronic drive unit which then powers the pump. The required connection cable between the OmniControl 200 and TC 110 is part number P103335 (2 M8 ports) or P1011168 (3 M8 ports) and is not included. The connection cable not only supplies power to the pump it also has M8 ports for connecting optional accessories such as a forced air-cooling kit, a solenoid vent valve, and/or a sealing gas valve. Input power to the OmniControl 200 is 115/230 VAC and a standard C14 rear-mounted socket is provided for mains power entry (power cord not included, part number P103361). This OmniControl 200 turbo pump display control unit and power supply has Pfeiffer part number PE D50 100 0. This controller replaces the discontinued TPG 361 PN: PT G28 040. The OmniControl 200 can control all the main parameters of the turbo pump via a 3 meter long RS485 interface cable (part number P1012287, not included). This unit can also be used to operate and display pressure readings from Pfeiffer Active gauges if the optional Gauge/IO module is installed. Pfeiffer turbo pump accessories, including inlet screens, forced air-cooling and water-cooling kits, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only) are available in other listings. The instruction manual for the OmniControl 200 controller and related documentation for Pfeiffer HiPace turbo pump products is available in the downloads.

Condition: New



Part Number: P1012598



Price: Kč54,706.25




Currency: Czech Koruna (CZK)

Pfeiffer TC 110 Electronic Drive Unit for HiPace 80 and HiPace 300 Turbo Pumps, PN: PM C01 790 AT
In Stock
3
Expecting 1
Anticipated Arrival 1 on 2025-01-31


Pfeiffer TC 110 Electronic Drive Unit for HiPace 80 and HiPace 300 Turbo Pumps. Pfeiffer Part Number: PM C01 790 AT The TC 110 electronic drive unit operates smaller Pfeiffer turbo pumps and their accessories. It’s purpose is to drive, monitor and control the pump. The TC 110 is designed to work with Pfeiffer HiPace 10, 30, 80, 300H and SplitFlow 50 and 80 turbo pumps. It requires 24 VDC input power, normally supplied by a Pfeiffer DCU 110 or OmniControl 200 controller through a special connection cable (part number P103335 or P1011168, not included). The connection cable supplies power to the pump and also has two M8 ports for connecting optional accessories such as a forced air-cooling kit, a solenoid vent valve, and/or a sealing gas valve. This unit replaces a damaged drive unit, or is required for pumps that do not include a drive unit. The TCU 110 electronic drive unit has Pfeiffer part number PM C01 790 AT. Pfeiffer turbo pump accessories, including inlet screens, forced air-cooling and water-cooling kits, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only) are available in other listings. The instruction manual for the TC 110 controller and related documentation for Pfeiffer HiPace turbo pump products is available in the downloads.

Condition: New



Part Number: P108873



Price: Kč48,093.41




Currency: Czech Koruna (CZK)

Pfeiffer Turbo OmniControl Controller and HiScroll Roughing Pump Power Supply Cord Mains Cable 115 VAC NEMA 5-15 to IEC C13, 3 m Long, PN: P 4564 309 ZE
In Stock
121


Pfeiffer Turbo OmniControl Controller and HiScroll Roughing Pump Power Supply Cord Mains Cable 115 VAC NEMA 5-15 to IEC C13, 3 m Long. This input power supply power cord (mains cable) is used on Pfeiffer OmniControl 200, 300, 400, and DCU 110 controllers, HiScroll dry scroll roughing/backing pumps, and with other Pfeiffer products. These power cords have a standard NEMA 5-15P 115 VAC plug one one end and an IEC320 C13 female socket connector on the other. This cable is 3 meters long (10 ft.) and has 18 gauge wire and 3 conductors (18/3).

Condition: New



Part Number: P103361



Price: Kč1,421.66




Currency: Czech Koruna (CZK)

Pfeiffer TC 110 Electronic Turbo Pump Drive Unit to OmniControl 200 Controller Connection Cable with Two M8 Accessory Ports 3 m Long, PN: PM 061 351-T
In Stock
19
Expecting 6
Anticipated Arrival 6 on 2025-01-22


Pfeiffer TC 110 Electronic Turbo Pump Drive Unit to OmniControl 200 Controller Connection Cable with Two M8 Accessory Ports 3 m Long. Pfeiffer Part Number: PM 061 351-T. This 3 meter long cable supplies power from a Pfeiffer OmniControl 200 or DCU-110 turbo pump controller to the integrated TC 110 electronic drive unit on Pfeiffer HiPace 80 and HiPace 300H turbo pumps. A 15-pin D-Sub connector on one end of the cable plugs into the TC 110 drive unit. The D-Sub connector splits out into two cables: The 3 meter long, heavy 3 conductor cable connects to the OmniControl 200 or DCU 110 unit and supplies 24 VDC power to the TC 110 and pump. The short cable emanating from the D-Sub connector is for communications. This short cable is extended with a 3 meter long RS485 extension cable (part number P1012287) which then connects to the OmniControl 200 or DCU-110 controller, allowing it to manage all main parameters and functions of the turbo pump. The 15-pin D-Sub connector is modified to include two M8 connectors in its side. These are accessory ports used to connect optional accessories such as a forced air-cooling kit, a solenoid vent valve, and/or a sealing gas valve. When adding accessories, make sure that the total power draw does not exceed the capacity of the controller. This two accessory power and communication connection cable has Pfeiffer part number PM 061 351-T.

Condition: New



Part Number: P103335



Price: Kč11,938.26




Currency: Czech Koruna (CZK)

Pfeiffer TC 110 Electronic Turbo Pump Drive Unit to OmniControl 200 Controller Connection Cable with Three M8 Accessory Ports 3 m Long, PN: PM 061 512-T
Out of Stock
Expecting 5
Anticipated Arrival 1 on 2024-12-06


Pfeiffer TC 110 Electronic Turbo Pump Drive Unit to OmniControl 200 Controller Connection Cable with Three M8 Accessory Ports 3 m Long. Pfeiffer Part Number: PM 061 512-T. This 3 meter long cable supplies power from a Pfeiffer OmniControl 200 or DCU-110 turbo pump controller to the integrated TC 110 electronic drive unit on Pfeiffer HiPace 80 and HiPace 300H turbo pumps. A 15-pin D-Sub connector on one end of the cable plugs into the TC 110 drive unit. The D-Sub connector splits out into two cables: The 3 meter long, heavy 3 conductor cable connects to the OmniControl 200 or DCU 110 unit and supplies 24 VDC power to the TC 110 and pump. The short cable emanating from the D-Sub connector is for communications. This short cable is extended with a 3 meter long RS485 extension cable (part number P1012287) which then connects to the OmniControl 200 or DCU-110 controller, allowing it to manage all main parameters and functions of the turbo pump. The 15-pin D-Sub connector is modified to include three M8 connectors in its side. These are accessory ports used to connect optional accessories such as a forced air-cooling kit, a solenoid vent valve, and/or a sealing gas valve. When adding accessories, make sure that the total power draw does not exceed the capacity of the controller. This three accessory power and communication connection cable has Pfeiffer part number PM 061 512-T.

Condition: New



Part Number: P1011168



Price: Kč15,239.17




Currency: Czech Koruna (CZK)

RS485 Communication Cable M12 to M12 Connectors, Connects Pfeiffer HiPace Turbo Pump TC Drive Unit to OmniControl Controller, 3 m Long.
In Stock
35


RS485 Communication Cable M12 to M12 Connectors, Connects Pfeiffer HiPace Turbo Pump TC Drive Unit to OmniControl Controller, 3 m Long. 3m Long. This cable meets or exceeds OEM specs (OEM PN: PM 061 283-T3). This special serial cable allows RS485 communications between a Pfeiffer HiPace turbo pump TC drive unit and a Pfeiffer OmniControl or DCU controller. This interface cable has 4-pin, M12, round screw-type connectors on both ends. This cable is 3 meters long (10 ft.) and meets or exceeds OEM specs (OEM PN: PM 061 283-T3). On TC 110 drive units, which have a 15-pin D-Sub (X3) connector, a power and communications adapter cable (part number P103335 or P1011168) is used to split out the X3 connector into a pump power cable and a short RS485 communication cable (terminated with an M12 connector). This 3 meter long RS485 cable attaches to and extends that short cable. The other end of this cable connects to the M12 round connector on an OmniControl or a DCU controller. On TC 400 and TC 1200 drive units, which have a separate round M12 communications connector, this cable directly connects the drive unit to an OmniControl controller. This Pfeiffer RS485 Communication Connector connects: TC 110 drive unit on HiPace 80 and 300H turbo pumps to an OmniControl 200 or DCU 110 controller (requires adapter cable P103335 or P1011168). TC 400 drive unit on HiPace 300, 350, 450, 700 and 800, to an OmniControl 300 or 400 controller (direct connction). TC 1200 drive unit on a HiPace 1200 turbo pump, to an OmniControl 001 controller (direct connction).

Condition: New



Part Number: P1012287



Price: Kč5,642.54




Currency: Czech Koruna (CZK)

RS485 Communication Cable M12 to M12 Connectors, Connects Pfeiffer HiPace Turbo Pump TC Drive Unit to OmniControl Controller, 10 m Long.
In Stock
2


RS485 Communication Cable M12 to M12 Connectors, Connects Pfeiffer HiPace Turbo Pump TC Drive Unit to OmniControl Controller, 10 m Long. 10m Long. This cable meets or exceeds OEM specs (OEM PN: PM 061 285 -T). This special serial cable allows RS485 communications between a Pfeiffer HiPace turbo pump TC drive unit and a Pfeiffer OmniControl or DCU controller. This interface cable has 4-pin, M12, round screw-type connectors on both ends. This cable is 10 meters long (10 ft.) and meets or exceeds OEM specs (OEM PN: PM 061 285 -T). On TC 110 drive units, which have a 15-pin D-Sub (X3) connector, a power and communications adapter cable (part number P103335 or P1011168) is used to split out the X3 connector into a pump power cable and a short RS485 communication cable (terminated with an M12 connector). This 10 meter long RS485 cable attaches to and extends that short cable. The other end of this cable connects to the M12 round connector on an OmniControl or a DCU controller. On TC 400 and TC 1200 drive units, which have a separate round M12 communications connector, this cable directly connects the drive unit to an OmniControl controller. This Pfeiffer RS485 Communication Connector connects: TC 110 drive unit on HiPace 80 and 300H turbo pumps to an OmniControl 200 or DCU 110 controller (requires adapter cable P103335 or P1011168). TC 400 drive unit on HiPace 300, 350, 450, 700 and 800, to an OmniControl 300 or 400 controller (direct connction). TC 1200 drive unit on a HiPace 1200 turbo pump, to an OmniControl 001 controller (direct connction).

Condition: New



Part Number: P1013178



Price: Kč8,335.57




Currency: Czech Koruna (CZK)

Pfeiffer Coarse Inlet Screen (4 mm) Splinter Guard fits HiPace Turbo Pumps with Conflat CF 4.5 in. Flange, PN: PM 016 333
In Stock
6


Pfeiffer Coarse Inlet Screen (4 mm) Splinter Guard fits HiPace Turbo Pumps with Conflat CF 4.5 in. Flange. Pfeiffer Part Number: PM 016 333. This Pfeiffer coarse inlet screen (4.0 mm mesh) is used to filter the vacuum flow and keep objects from being sucked into the HiPace 80 turbo pump. This screen has a CF 4.5" flange size. Depending on the gas used, some pump speed reduction will occur when using this screen. This coarse screen centering ring has Pfeiffer part number PM 016 333. This screen fits: HiPace 80 with Conflat CF 4.5" flange, Pfeiffer pump part number: PM P03 941 A

Condition: New



Part Number: P105099



Price: Kč7,195.31




Currency: Czech Koruna (CZK)

Pfeiffer Fine Inlet Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with DN40 KF-40 Flange, PN: PM 006 375-X
In Stock
4


Pfeiffer Fine Inlet Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with DN40 KF-40 Flange. Pfeiffer Part Number: PM 006 375-X. This Pfeiffer fine inlet screen (0.8 mm mesh) is used to filter the vacuum flow and keep objects from being sucked into the HiPace 80 turbo pump. This screen has a DN40 KF-40 flange size. Depending on the gas used, some pump speed reduction will occur when using this screen. This fine screen centering ring has Pfeiffer part number PM 006 375-X. This screen fits: HiPace 80 with KF-40 flange, Pfeiffer pump part number: PM P03 942 A

Condition: New



Part Number: P108092



Price: Kč5,276.04




Currency: Czech Koruna (CZK)

Pfeiffer Fine Inlet Centering Ring Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with DN 63 ISO-K 63 Flange, PN: PM 016 207 AU
In Stock
8


Pfeiffer Fine Inlet Centering Ring Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with DN 63 ISO-K 63 Flange. Pfeiffer Part Number: PM 016 207 AU. This Pfeiffer fine inlet screen (0.8 mm mesh) with centering ring has a multifunctional coating for anti-twist protection. It is used to filter the vacuum flow and keep objects from being sucked into the HiPace 80 turbo pump. This screen has an ISO-K 63 flange size. Depending on the gas used, some pump speed reduction will occur when using this screen. This fine screen centering ring has Pfeiffer part number PM 016 207 AU. This screen fits: HiPace 80 with ISO-K 63 flange, Pfeiffer pump part number: PM P03 940

Condition: New



Part Number: P103360



Price: Kč10,769.96




Currency: Czech Koruna (CZK)

Pfeiffer Fine Inlet Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with Conflat CF 4.5 in. Flange, PN: PM 016 312
In Stock
5
Expecting 6


Pfeiffer Fine Inlet Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with Conflat CF 4.5 in. Flange. Pfeiffer Part Number: PM 016 312. This Pfeiffer fine inlet screen (0.8 mm mesh) is used to filter the vacuum flow and keep objects from being sucked into the HiPace 80 turbo pump. This screen has a CF 4.5" flange size. Depending on the gas used, some pump speed reduction will occur when using this screen. This coarse screen centering ring has Pfeiffer part number PM 016 312. This screen fits: HiPace 80 with Conflat CF 4.5" flange, Pfeiffer pump part number: PM P03 941 A

Condition: New



Part Number: P105097



Price: Kč6,989.89




Currency: Czech Koruna (CZK)

Pfeiffer Radial Air Cooling Fan Unit for HiPace 80 Turbo Pumps with TC 110 Drive Unit Powered by M8 Accessory Connector, PN: PM Z01 300 AT
In Stock
107


Pfeiffer Radial Air Cooling Fan Unit for HiPace 80 Turbo Pumps with TC 110 Drive Unit With M8 Accessory Connector. Pfeiffer Part Number: PM Z01 300 AT. This Pfeiffer air cooling fan unit mounts to the side of HiPace 80 turbo pumps and provides air flow perpendicular to the pump. The HiPace 80 turbo pump’s integrated TC 110 drive unit has a 15-pin D-Sub X3 connector which uses a special cable through which power is supplied by an OmniControl 200 or DCU 110 controller. This special cable (part number P103335 or P1011168, sold separately) has several M8 ports on it to power accessories. This air cooling fan plugs into one of the cable’s M8 ports. The air cooling unit will always run when the pump is on. This radial air cooling fan unit has Pfeiffer part number PM Z01 300 AT.

Condition: New



Part Number: P103333



Price: Kč16,130.13




Currency: Czech Koruna (CZK)

Pfeiffer Water Cooling Kit For HiPace 80 350 450 Turbo Pumps with Push-Fit Connectors for 8 mm OD Hose and G 1/8" Fittings, PN: PM 016 623 -T
In Stock
3
Expecting 1
Anticipated Arrival 1 on 2025-02-19


Pfeiffer Water Cooling Kit For HiPace 80, 350 and 450 Turbo Pumps with Push-Fit Connectors for 8 mm OD Hose and G 1/8" Fittings. Pfeiffer Part Number: PM 016 623 -T. This water cooling unit fits Pfeiffer HiPace 80 turbo pumps. It attaches to the side of the pump with two included bolts. This water cooling block has push-fit connectors for the supply and discharge hoses (8mm OD plastic hose). The hose connections may be unscrewed and removed to make use of the integrated G 1/8” threads. This water cooling kit is required when using a flange heater band with a CF flanged pump. Pfeiffer HiPace turbo pumps also benefit from water cooling when there are high gas throughputs, cyclic operations and/or high ambient temperatures. In order to ensure long trouble-free operation, the cooling water must be clean and not contain any oils, greases or suspended solids. This water cooling unit has Pfeiffer part number PM 016 623 -T.

Condition: New



Part Number: P103334



Price: Kč6,764.33




Currency: Czech Koruna (CZK)

Pfeiffer Intake Flange Heater Band Conflat CF 4.5 in. 115 VAC for HiPace 80 Turbo Pump with TC 110 Drive Unit, PN: PM 061 362-T
In Stock
2


Pfeiffer Intake Flange Heater Band Conflat CF 4.5 in. 115 VAC for HiPace 80 Turbo Pump with TC 110 Drive Unit, PN: PM 061 362-T. Pfeiffer Part Number: PN: PM 061 362-T. This is a 115 VAC Leybold intake flange heater for the HiPace 80 turbo pump with CF 4.5 inch flange (DN 63 CF) and TC 110 drive unit. The intake flange may be baked up to 120 °C if the turbo pump is water cooled. Operate the pump with water cooling when baking out. Do not use this intake flange heater band on an air cooled pump - damage to the pump will occur. The band heater has an attached relay box with a short control cable with M8 connector which connects to an accessory port on a special TC 110 drive unit to OmniControl 200 connection cable (part number P103335 or P1011168, sold separately). The relay box must be wired with appropriate cable and plug to a 115 VAC power source. This heater band for the HiPace 80 turbo pump with Conflat CF 4.5" flange has part number PM 061 362-T. Heater Band Specs: Fits: HiPace 80 turbo pump with CF 4.5 in.flange (P103316) Water Cooling Option (required): P103334 Heater Band Voltage: 115 VAC Accessory Connection: M8 Recommended Controller: OmniControl 200

Condition: New



Part Number: P1012613



Price: Kč23,307.47




Currency: Czech Koruna (CZK)

Pfeiffer Shielded Sealing Gas Purge Valve for HiPace 80 Turbo Pumps with TC 110 Drive Unit Normally Closed (NC) G 1/8" Male Fitting M8 Connection, PN: PM Z01 310 A
In Stock
2


Pfeiffer Shielded Sealing Gas Valve for HiPace 80 Turbo Pumps with TC 110 Drive Unit Normally Closed (NC) G 1/8" Male Fitting M8 Connection. Pfeiffer Part Number: PM Z01 310 A. This shielded Pfeiffer sealing gas valve (purge valve) for HiPace 80 turbo pumps with a TC 110 drive unit screws into the G 1/8" (BSPP) sealing gas port of the pump (sealing ring and filter included). It prevents the ingress of damaging substances, such as corrosive materials into the motor and bearing area of the pump. The use of this sealing gas valve also ensures proper rotor cooling and protects the pump from being damaged by high gas throughput (> 50 % of the pump’s maximum). This valve allows a suitable, constant flow rate of inert gas (7.5 - 9.5 sccm @ maximum 1.5 bar absolute) into the pump. This 24 VDC normally closed (NC) electric solenoid sealing gas valve has Pfeiffer part number PM Z01 310 A. This valve has an M8 electical connector that plugs into one of the accessory ports in the TC 110-to-controller cable (part number P103335 or P1011168, sold separately). The TC 110 drive unit controls and supplies power to the valve. Note that the activation (control) of this valve for the sealing gas connection is not pre-installed in the electronic drive unit and must be configured by the using a Pfeiffer controller (OmniControl 200 or DCU 110) or externally via RS485.

Condition: New



Part Number: P107659



Price: Kč26,628.27




Currency: Czech Koruna (CZK)

Pfeiffer Venting Valve for Small HiPace Turbo Pumps with TC110 Drive Unit Normally Closed (NC) G 1/8" Male Fitting M8 Connection, PN: PM Z01 290 C
In Stock
5


Pfeiffer Venting Valve for HiPace 80 and 300H Turbo Pumps with TC110 Drive Unit Normally Closed (NC) G 1/8" Mle Fitting M8 Connection. Pfeiffer Part Number: PM Z01 290 C. This Pfeiffer venting valve for HiPace 80 and 300H turbo pumps with a TC 110 drive unit screws into the G 1/8" (BSPP) vent port of the pump (sealing ring included). It ensures the controlled, automatic venting of the turbo pump after shutting down or in the event of a power failure, and limits an uncontrollable pressure rise rate in excess of the permissable maximum (15 hPa/s), thus preventing possible damage to the pump’s rotor and magnetic bearing. This valve has an M8 electical connector that plugs into one of the accessory ports in the TC 110-to-controller cable (part number P103335 or P1011168, sold separately). The TC 110 drive unit controls and supplies power to the valve. The activation (control) of this valve for the venting connection is user configured and supported by Pfeiffer controllers (OmniControl 200 or DCU 110) or externally via RS485. This Pfeiffer venting valve for HiPace 80 and 300H turbo pumps with integrated drive unit has part number PM Z01 290 C.

Condition: New



Part Number: P103336



Price: Kč26,761.07




Currency: Czech Koruna (CZK)

Pfeiffer Vacuum Flange Adapter G 1/8" BSPP to KF-10 for all HiPace Turbo Pump Vent or Sealing Gas Ports, PN: PM 033 737-T
In Stock
2


Pfeiffer Vacuum Flange Adapter G 1/8" BSPP to KF-10 for all HiPace Turbo Pump Vent or Sealing Gas Ports. Pfeiffer Part Number: PM 033 737-T . This Pfeiffer vacuum flange adapter can be used on all HiPace turbo pumps. It screws into the G 1/8" BSPP vent or sealing gas port on the pump (sealing ring included), and converts the port into a standard KF-10 flange for easy connection to the user’s vacuum system. It can be used for connection to venting valves, sealing gas valves, power failure venting units, sealing gas throttles, etc. This vacuum flange adapter has Pfeiffer part number PM 033 737-T . This vacuum flange adapter fits the vent or gas sealing ports on all these Pfeiffer turbo pumps: HiPace 80 HiPace 300 HiPace 300C HiPace 350 HiPace 450 HiPace 700 HiPace 800 HiPace 1200

Condition: New



Part Number: P105885



Price: Kč8,093.23




Currency: Czech Koruna (CZK)

Pfeiffer Vacuum Flange Adapter G 1/8" BSPP to KF-16 for all HiPace Turbo Pump Vent or Sealing Gas Ports, PN: PM 016 780-T
In Stock
4
Expecting 1
Anticipated Arrival 1 on 2025-01-22


Pfeiffer Vacuum Flange Adapter G 1/8" BSPP to KF-16 for all HiPace Turbo Pump Vent or Sealing Gas Ports. Pfeiffer Part Number: PM 016 780-T. This Pfeiffer vacuum flange adapter can be used on all HiPace turbo pumps. It screws into the G 1/8" BSPP vent or sealing gas port on the pump (sealing ring included), and converts the port into a standard KF-16 flange for easy connection to the user’s vacuum system. It can be used for connection to venting valves, sealing gas valves, power failure venting units, sealing gas throttles, etc. This vacuum flange adapter has Pfeiffer part number PM 016 780-T. This vacuum flange adapter fits the vent or gas sealing ports on all these Pfeiffer turbo pumps: HiPace 80 HiPace 300 HiPace 300C HiPace 350 HiPace 450 HiPace 700 HiPace 800 HiPace 1200

Condition: New



Part Number: P105886



Price: Kč3,093.81




Currency: Czech Koruna (CZK)

Pfeiffer HiPace 80 Turbo Pump Maintenance Replacement Oil Fluid Reservoir Kit Lubricates Mechanical Bearing, PN: PM 143 740-T
In Stock
13
Expecting 7
Anticipated Arrival 7 on 2025-01-03


Pfeiffer HiPace 80 Turbo Pump Maintenance Replacement Oil Fluid Reservoir Kit Lubricates Mechanical Bearing. Pfeiffer Part Number: PM 143 740-T. This Pfeiffer HiPace 80 turbo pump oil fluid reservoir kit is used when performing Level 1 maintenance on the pump. The oil fluid reservoir lubricates the mechanical bearing at the bottom of the pump and keeps the pump operating at peak efficiency. This kit includes the oil fluid lubricant impregnated felt reservoir, O-ring and other required seals. The reservoir comes pre-filled with the proper amount of oil. Additional lubricant is not required. The oil fluid reservoir kit should be replaced at a minimum of every 4 years - more frequently if the pump is used under extreme operating conditions, or if the pump is exposed to unclean processes. This Pfeiffer oil fluid reservoir kit has part number PM 143 740-T. Directions for replacing the oil fluid reservoir are located in the pump’s instruction manual, available in the downloads.

Condition: New



Part Number: P105686



Price: Kč4,701.96




Currency: Czech Koruna (CZK)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com