Keyword Part Number:
Varian Agilent 563 Glass Ion Gauge Tube, Tungsten filament, KF25 NW25 Kovar Flange, Vacuum Pressure Gauge. PN:K2466306 These Ion Gauge Tubes have a KF25 NW25 Kovar Flange vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament +30 VDC with 4 VAC filament voltage). In high and ultra-high vacuum ranges, a platinum shield prevents external electrical fields from affecting the low ion current. In higher pressure ranges where the number of ions produced is much greater, the platinum conductive coating drains off the static charge which can build up on the inside of the glass tube. Thus, the 563 tube gives superior performance throughout the entire range of the tube. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. For Instruction Manual on the Agilent Varian 563 Ion Gauge, download the .pdf below at AVAILABLE DOWNLOADS. Typically Works With: Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others. MKS Instruments 290, 919, 929 Perkin Elmer DGC3 Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 572 Tube K7360301 Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002
Condition: New
Part Number: P107262
Price: Kč13,932.08
Agilent Varian 572 Dual Tungsten Filament Glass Ion Gauge Tube, Bayard-Alpert Style, 1 inch Port, Vacuum Pressure Gauge. Agilent Varian Part Number K7360301 These dual tungsten glass ion gauge tubes have a 1 inch port vacuum connection and an operating range from 1x10-3 to 2x10-10 Torr. These ion gauge tubes are compatible with most modern hot cathode ion gauge tubes. They have a sensitivity of 10 Torr-1 and standard operating voltages (collector 0 VDC, Grid +180 VDC, filament -30 VDC with 5 VAC). The hot tungsten filaments react with oxygen to rapidly form tungsten oxide and therefore poor vacuum can rapidly cause catastrophic oxidation of hot tungsten components. They are most practical in environments having little risk of oxygen exposure. However, tungsten filamets are suited for applications where backstreaming of oil from diffusion pumps is heavy. Dual tungsten filament ion gauge tubes can be identified by two opposing helical filaments and have six external leads at the plug end. Our replacement ion gauge tubes work with most hot cathode ion gauge controllers made by Granville Phillips, MKS Instruments, Perkin Elmer, Varian, & Veeco. For Instruction Manual on the Agilent Varian 572 Ion Gauge, download the .pdf below at Manuals: AVAILABLE DOWNLOADS. Typically Works With: Granville Phillips Models 260, 270, 280, 303, 306, 307 330, 340 ,350, and others. MKS Instruments 290, 919, 929 Perkin Elmer DGC3 Varian 831, 836, 842, 844, 845, 880, 971-0003, 971-0014, 971-1008, Multi-Gauge, Varian 572 Tube K7360301 Veeco RG2, RG3, RG21, RG31, RG81, RG83, RG84, RG830, RG840, RG1000, RG1002
Condition: New
Part Number: P105363
Price: Kč6,455.12