Keyword Part Number:
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 0.4 to 20 sccm, 15-pin D-subminiature, 4 VCR Male. MKS Part Number: GM50A013201RMM020. The MKS GM50A Mass Flow Controller is capable of being configured to control N2 or equivalent, having a Full-Scale Flow Range of 20 sccm and a control range of 0.4 to 20 sccm. It has a 15-pin D-subminiature analog connector with tied grounds, a 0-5 VDC flow input/output signal and a Swagelok® 4 VCR® male input and output fittings. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1012836
Price: Kč67,381.11
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 0.4 to 20 sccm, RS - 485 Serial Communication Protocol, 4 VCR Male. MKS Part Number: GM50A015201R5M020. The MKS GM50A Mass Flow Controller is configured to control O2 or equivalent, having a Full-Scale Flow Range of 20 sccm and a control range of 0.4 to 20 sccm. It has a RS - 485 serial communication port, a 0-5 VDC or or 4 to 20 mA flow input/output signal and a Swagelok® 4 VCR® male input and output fittings. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1013700
Price: Kč61,494.80
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 1 to 50 sccm, RS - 485 Serial Communication Protocol, 4 VCR Male. MKS Part Number: GM50A015501R5M020. The MKS GM50A Mass Flow Controller is configured to control O2 or equivalent, having a Full-Scale Flow Range of 50 sccm and a control range of 1 to 50 sccm. It has a RS - 485 serial communication port, a 0-5 VDC or or 4 to 20 mA flow input/output signal and a Swagelok® 4 VCR® male input and output fittings. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1013701
Price: Kč61,494.80
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 1 to 50 sccm, RS - 485 Serial Communication Protocol, 4 VCR Male. MKS Part Number: GM50A013501R5M020. The MKS GM50A Mass Flow Controller is configured to control N2 or equivalent, having a Full-Scale Flow Range of 50 sccm and a control range of 1 to 50 sccm. It has a RS - 485 serial communication port, a 0-5 VDC or or 4 to 20 mA flow input/output signal and a Swagelok® 4 VCR® male input and output fittings. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1013702
Price: Kč61,494.80
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 0.4 to 20 sccm, RS - 485 Serial Communication Protocol, 4 VCR Male. MKS Part Number: GM50A013201R5M020. The MKS GM50A Mass Flow Controller is configured to control N2 or equivalent, having a Full-Scale Flow Range of 50 sccm and a control range of 0.4 to 20 sccm. It has a RS - 485 serial communication port, a 0-5 VDC or or 4 to 20 mA flow input/output signal and a Swagelok® 4 VCR® male input and output fittings. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1013703
Price: Kč61,494.80
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 4 to 200 sccm, RS - 485 Serial Communication Protocol, 4 VCR Male. MKS Part Number: GM50A004202R5M020. The MKS GM50A Mass Flow Controller is configured to control Ar or equivalent, having a Full-Scale Flow Range of 200 sccm and a control range of 4 to 200 sccm. This 200sccm Argon unit can be "downranged" to 141sccm through the software, bringing the controllable range from 4-200sccm to ~2.8-141sccm Argon. It has a RS - 485 serial communication port, a 0-5 VDC or or 4 to 20 mA flow input/output signal and a Swagelok® 4 VCR® male input and output fittings. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1013704
Price: Kč61,494.80
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Ranged of 1 to 50 sccm, 15-pin Connector, 4 VCR Male. PN: GM50A013501RMM020. MKS Part Number: GM50A013501RMM020. The MKS GM50A Mass Flow Controller is capable of being configured to control a wide range of Safe Delivery Source Gasses (SDS). Input and output fittings are Swagelok® 4 VCR® male. It has a Full Scale Flow Range of 50 sccm and a control range of 1 to 50 sccm, a 15-pin D-subminiature connector with tied grounds, and a 0-5 VDC flow input/output signal. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1012838
Price: Kč55,737.44
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 2 to 100 sccm, 15-pin D-subminiature, 4 VCR Male. PN: GM50A013102RMM020. MKS Part Number: GM50A013102RMM020. The MKS GM50A Mass Flow Controller is capable of being configured to control a wide range of Safe Delivery Source Gasses (SDS). Input and output fittings are Swagelok® 4 VCR® male. It has a Full Scale Flow Range of 100 sccm and a control range of 2 to 100 sccm, a 15-pin D-subminiature connector with tied grounds, and a 0-5 VDC flow input/output signal. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1012839
Price: Kč55,737.44
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 4 to 200 sccm, 15-pin D-subminiature. MKS Part Number: GM50A013202RMM020. The MKS GM50A Mass Flow Controller is capable of being configured to control a wide range of Safe Delivery Source Gasses (SDS). Input and output fittings are Swagelok® 4 VCR® male. It has a Full Scale Flow Range of 200 sccm and a control range of 4 to 200 sccm, a 15-pin D-subminiature connector with tied grounds, and a 0-5 VDC flow input/output signal. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1012835
Price: Kč58,549.12
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 10 to 500 sccm, 15-pin D-subminiature, 4 VCR male. MKS Part Number: GM50A013502RMM020. The MKS GM50A Mass Flow Controller is capable of being configured to control a wide range of Safe Delivery Source Gasses (SDS). Input and output fittings are Swagelok® 4 VCR®. It has a Full Scale Flow Range of 500 sccm and a control range of 10 to 500 sccm, a 15-pin D-subminiature connector with tied grounds, and a 0-5 VDC flow input/output signal. Digital calibration yields 1% of set point accuracy on the calibration gas. Typical response times are on the order of 500 milliseconds. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1012834
Price: Kč67,381.11
MKS GM50A Mass Flow Controller (MFC) Digitally-Controlled, Range of 20 to 1000 sccm, 15-pin D-subminiature Connector, 4 VCR Male. MKS Part Number: GM50A013103RMM020. The MKS GM50A Mass Flow Controller is capable of being configured to control a wide range of Safe Delivery Source Gasses (SDS). Input and output fittings are Swagelok® 4 VCR® male. It has a Full Scale Flow Range of 1000 sccm and a control range of 20 to 1000 sccm, a 15-pin D-subminiature connector with tied grounds, and a 0-5 VDC flow input/output signal. Typical response times are on the order of 500 milliseconds. Digital calibration yields 1% of set point accuracy on the calibration gas. The multi-range capabilities can be configured through a web browser based application accessed by plugging the MFC into a router or a computer via Ethernet cable. The E-diagnostics application allows a user to monitor the MFC’s performance in real time as well as plot data and select variables. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1012837
Price: Kč67,381.11
MKS 946 Half-Rack Vacuum Gauge Controller Power Supply and Readout, NO Cards, RS232 and RS485, 6 Channels. MKS Part Number: 946-US-NANANA-NA. The MKS 946 is a versatile half-rack vacuum gauge measurement and control system, it provides power and simultaneous readout for up to six different vacuum gauges and/or mass flow controllers, with options for controlling pressure. This is a raw unit without cards. Power Supplies/Readouts are designed to control and display any flow transducer. The flow rate set point can be adjusted either through front panel controls or remotely through the rear panel analog interface. The 946 Vacuum System Controller is a six channel/sequentially selectable single readout. Compatible with mass flow controllers and mass flow readouts. Signal cables and optional cards for the MKS 946 are available on this website.
Condition: New
Part Number: P1012840
Price: Kč76,368.42
MKS Control Card Mass Flow Controller Series 946 and Dual Mass Flow Controllers. MKS Part Number: 20000712. The MKS Control Card Mass Flow Controller is compatible with the 946 and dual Mass Flow controllers. These cards are used on controllers designed to control and display any flow transducer. The flow rate set point can be adjusted either through front panel controls or remotely through the rear panel analog interface. The 946 Vacuum System Controllers simultaneous readout & control of up to 6 sensors and gauges.
Condition: New
Part Number: P1012844
Price: Kč19,195.90
MKS Vacuum Gauge Cable Connects 946 Controller to 179, 1179, 1462, 1479, 1559, 2179, GE50A, GM50A, IE50A, IM50A, IM250A, P250A, 10 ft. (3m) Long. MKS Part Number: 100016744. The MKS Mass Flow Controller Cable connects 179, 1179, 1462, 1479, 1559, 2179, GE50A, GM50A, IE50A, IM50A, IM250A, P250A mass flow controllers to 946 controllers with 15-pin type D High-density subminiature to 15-pin standard subminiature connectors. This is the Cable ONLY. The MKS 946 is a versatile half-rack vacuum gauge measurement and control system, it provides power and simultaneous readout for up to six different vacuum gauges and/or mass flow controllers, with options for controlling pressure. Power Supplies/Readouts are designed to control and display any flow transducer. The flow rate set point can be adjusted either through front panel controls or remotely through the rear panel analog interface. The 946 Vacuum System Controller is a six channel/sequentially selectable single readout. Compatible with mass flow controllers and mass flow readouts. Signal cables for the MKS 946 are available on this website.
Condition: New
Part Number: P1012858
Price: Kč4,716.34
MKS Vacuum Gauge Cable Connects 946 Controller to 179, 1179, 1462, 1479, 1559, 2179, GE50A, GM50A, IE50A, IM50A, IM250A, P250A, 25 ft. (7.5m) Long. MKS Part Number: 100016745. The MKS Mass Flow Controller Cable connects 179, 1179, 1462, 1479, 1559, 2179, GE50A, GM50A, IE50A, IM50A, IM250A, P250A mass flow controllers to 946 controllers with 15-pin type D High-density subminiature to 15-pin standard subminiature connectors. This is the Cable ONLY. The MKS 946 is a versatile half-rack vacuum gauge measurement and control system, it provides power and simultaneous readout for up to six different vacuum gauges and/or mass flow controllers, with options for controlling pressure. Power Supplies/Readouts are designed to control and display any flow transducer. The flow rate set point can be adjusted either through front panel controls or remotely through the rear panel analog interface. The 946 Vacuum System Controller is a six channel/sequentially selectable single readout. Compatible with mass flow controllers and mass flow readouts. Signal cables for the MKS 946 are available on this website.
Condition: New
Part Number: P1012859
Price: Kč7,224.56