Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-dk
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Pfeiffer ASM340 Leak Detectors On Sale Adixen 2021C2 Pumps On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent TriScroll Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Edwards nEXT85D Turbo Vacuum Pump with NW40 KF-40 Inlet Flange 61 l/s Pumping Speed Air or Water Cooled. PN: B8G210A01
In Stock
6


Edwards nEXT85D Turbo Vacuum Pump with NW40 KF-40 Inlet, 61 l/s Pumping Speed, Air or Water Cooled. Edwards Part Number: B8G210A01. Edwards nEXT85D turbomolecular high vacuum pumps with an NW40 KF-40 inlet flange have a pumping speed of 61 liters per second (l/s) and an ultimate pressure of 8 x 10-8 mbar (6 x 10-8 Torr). This nEXT85D pump has an included inlet screen, and an ISO KF-16 exhaust foreline flange. The nEXT85D series turbo pumps require 24 to 48 VDC input power at a maximum of 120 Watts (normal operation is typically less than 80 Watts). A permanently attached DB15 combination power and control cable is standard on the pump. All nEXT85D turbo pumps have a compact onboard controller with RS232, RS485, & USB interfaces, five status LED’s, and an accessory port to control either an air-cooling fan or a solenoid vent valve ( a "Y" connector is available for connecting both a fan and valve). All that is needed is a suitable power supply and start/stop logic. For laboratory use we recommend the Edwards Turbo Instrument Controller (TIC) or the Turbo Active Gauge (TAG) which can both act as a power supply and remote controller for the smaller sized nEXT pumps. We also offer a variety of optional accessories, including the TIC and TAG, forced air and water cooling kits, along with solenoid operated vent valves. This nEXT85D turbo pump has Edwards part number B8G210A01.Edwards nEXT85D Turbo Pump Specifications: Part Number: B8G210A01 Inlet Flange: NW40 KF-40 Base Pressure: 8 x 10-8 mbar (6 x 10-8 Torr) Operating Speed: 90,000 RPM Operating Position: From horizontal to vertical (inlet up) Pumping Speed: 61 l/s Cooling: Forced Air or Water Exhaust Flange: KF-16 Operating Voltage: 24-48 VDC Maximum Power: 120 Watts (typical operation < 80 Watts) Power and Communication: DB15 serial RS232/RS485 interface, USB One accessory port Recommended Roughing Pump: nXDS6i The nEXT turbo pumps have a rotor designed to optimize pump performance while maintaining high levels of reliability. The "D" variant of nEXT turbo pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures, and have superior pumping speed and compression across all gas species. In addition to enhanced performance, all nEXT turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decrease downtime. nEXT D turbo pumps benefit from a compact onboard controller which has drive electronics for controlling pump operation and standby speed, and operating solenoid vent valves (TAV5, TAV6) and air-cooling units (via the 24 VDC accessory port). The integral controller has a DB15 interface for RS232 and RS485 serial communications and for supplying pump power. The USB port allows the use of Edwards nST2 PC software (free download from link below). The controller also has five indicator LED’s which signal the general status, operation, and service status of the pump. The optional TIC turbo instrument controller, or TAG turbo and active gauge controller can both power and control the pump. Edwards nEXT pumps with a CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO or KF flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat flanged nEXT85D pumps can be baked up to 120 °C when the turbo is water cooled. Heater bands for the Conflat pumps are sold separately. For vacuum system integration applications, the nEXT85D pump can be powered by a suitable user supplied 24 to 48 VDC power source. For laboratory applications we recommend the Edwards TIC turbo instrument controller or the TAG turbo & active gauge controller, either of which can both supply power and control the pump. The TIC series of controllers are bench top or rack mountable remote user interface/power sources, which communicate with the Edwards nEXT series pumps through RS232/RS485 and provide full monitoring and control of the turbo pump, and optionally for one or more vacuum gauge instruments. When an Edwards relay box is added, it becomes the control interface between the TIC controller and the mains backing pump, turbo pump flange heater band, and a backing line isolation valve. The TAG turbo and active gauge controller can power nEXT85D turbo pumps and a vacuum gauge, and its large LED display can show pump speed or vacuum pressure. The pump instruction manual and Edwards nEXT pump product brochures are available in the downloads section. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments

Condition: New



Part Number: P109210



Price: Kr40,163.14


Regular Price: Kr57,375.90




Currency: Danish Krone (DKK)

Edwards nEXT85D Turbo Vacuum Pump with ISO-K 63 Inlet Flange 84 l/s Pumping Speed Air or Water Cooled. PN: B8G210B01
In Stock
9


Edwards nEXT85D Turbo Vacuum Pump, ISO-K 63 Inlet, 84 l/s Pumping Speed, Air or Water Cooled. Edwards Part Number: B8G210B01. Edwards nEXT85D turbomolecular high vacuum pumps have a pumping speed of 84 liters per second (l/s) and an ultimate pressure of 8 x 10-8 mbar (6 x 10-8 Torr). This nEXT85D pump has an ISO-K 63 inlet flange, included inlet screen, and an ISO KF-16 exhaust foreline flange. The nEXT85D series turbo pumps require 24 to 48 VDC input power at a maximum of 120 Watts (normal operation is typically less than 80 Watts). All nEXT85D turbo pumps have a compact onboard controller with RS232, RS485, & USB interfaces, five status LED’s, and an accessory port to control either an air-cooling fan or a solenoid vent valve ( a "Y" connector is available for connecting both a fan and valve). All that is needed is a suitable power supply and start/stop logic. For laboratory use we recommend the Edwards Turbo Instrument Controller (TIC) or the Turbo Active Gauge (TAG) which can both act as a power supply and remote controller for the smaller sized nEXT pumps. We offer a variety of optional accessories, including TIC and TAG controllers, forced air- & water-cooling kits, and solenoid operated vent valves. This nEXT85D turbo pump has Edwards part number B8G210B01.Edwards nEXT85D Turbo Pump Specifications: Part Number: B8G210B01 Inlet Flange: ISO-K 63 Base Pressure: 8 x 10-8 mbar (6 x 10-8 Torr) Operating Speed: 90,000 RPM Operating Position: From horizontal to vertical (inlet up) Pumping Speed: 84 l/s Cooling: Forced Air or Water Exhaust Flange: KF-16 Operating Voltage: 24-48 VDC Maximum Power: 120 Watts (typical operation < 80 Watts) Power and Communication: DB15 serial RS232/RS485 interface, USB One accessory port Recommended Roughing Pump: nXDS6i The nEXT turbo pumps have a rotor designed to optimize pump performance while maintaining high levels of reliability. The "D" variant of nEXT turbo pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures, and have superior pumping speed and compression across all gas species. In addition to enhanced performance, nEXT85D turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decrease downtime. nEXT D turbo pumps benefit from a compact onboard controller which has drive electronics for controlling pump operation and standby speed, and operating solenoid vent valves (TAV5, TAV6) and air-cooling units (via the 24 VDC accessory port). The integral controller has a DB15 interface for RS232 and RS485 serial communications and for supplying pump power. The USB port allows the use of Edwards nST2 PC software (free download below). The controller also has five indicator LED’s which signal the general status, operation, and service status of the pump. The optional TIC turbo instrument controller, or TAG turbo and active gauge controller can both power and control the pump. Edwards nEXT pumps with a CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat flanged nEXT85D pumps can be baked up to 120 °C when the turbo is water cooled. Heater bands for the Conflat pumps are sold separately. For vacuum system integration applications, the nEXT85D pump can be powered by a suitable user supplied 24 to 48 VDC power source. For laboratory applications we recommend the Edwards TIC turbo instrument controller or the TAG turbo & active gauge controller, either of which can both supply power and control the pump. The TIC series of controllers are bench top or rack mountable remote user interface/power sources, which communicate with the Edwards nEXT series pumps through RS232/RS485 and provide full monitoring and control of the turbo pump, and optionally for one or more vacuum gauge instruments. When an Edwards relay box is added, it becomes the control interface between the TIC controller and the mains backing pump, turbo pump flange heater band, and a backing line isolation valve. The TAG turbo and active gauge controller can power nEXT85D turbo pumps and a vacuum gauge, and its large LED display can show pump speed or vacuum pressure. The pump instruction manual and Edwards nEXT pump product brochures are available in the downloads section. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments

Condition: New



Part Number: P109211



Price: Kr40,163.14


Regular Price: Kr57,375.90




Currency: Danish Krone (DKK)

Edwards nEXT85D Turbo Vacuum Pump with Conflat CF 4.5 in. DN63 CF Inlet Flange 84 l/s Pumping Speed Air or Water Cooled. PN: B8G210C01
In Stock
12


Edwards nEXT85D Turbo Vacuum Pump with Conflat CF 4.5" DN63 CF Inlet, 84 l/s Pumping Speed, Air or Water Cooled. Edwards Part Number: B8G210C01. Edwards nEXT85D turbomolecular high vacuum pumps with a DN63 CF, Conflat CF 4.5 inch inlet flange have a pumping speed of 84 liters per second (l/s) and an ultimate pressure of 5 x 10-10 mbar (3.7 x 10-10 Torr). This nEXT85D pump has an included inlet screen, and an ISO KF-16 exhaust foreline flange. The nEXT85D series turbo pumps require 24 to 48 VDC input power at a maximum of 120 Watts (normal operation is typically less than 80 Watts). A permanently attached DB15 combination power and control cable is standard on the pump. All nEXT85D turbo pumps have a compact onboard controller with RS232, RS485, & USB interfaces, five status LED’s, and an accessory port to control either an air-cooling fan or a solenoid vent valve ( a "Y" connector is available for connecting both a fan and valve). All that is needed is a suitable power supply and start/stop logic. For laboratory use we recommend the Edwards Turbo Instrument Controller (TIC) or the Turbo Active Gauge (TAG) which can both act as a power supply and remote controller for the smaller sized nEXT pumps. We also offer a variety of optional accessories, including the TIC and TAG, forced air and water cooling kits, along with solenoid operated vent valves. This nEXT85D turbo pump has Edwards part number B8G210C01.Edwards nEXT85D Turbo Pump Specifications: Part Number: B8G210C01 Inlet Flange: DN63 CF, CF 4.5 in. Base Pressure: 5 x 10-10 mbar (3.7 x 10-10 Torr) Operating Speed: 90,000 RPM Operating Position: From horizontal to vertical (inlet up) Pumping Speed: 84 l/s Cooling: Forced Air or Water Exhaust Flange: KF-16 Operating Voltage: 24-48 VDC Maximum Power: 120 Watts (typical operation < 80 Watts) Power and Communication: DB15 serial RS232/RS485 interface, USB One accessory port Recommended Roughing Pump: nXDS6i The nEXT turbo pumps have a rotor designed to optimize pump performance while maintaining high levels of reliability. The "D" variant of nEXT turbo pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures, and have superior pumping speed and compression across all gas species. In addition to enhanced performance, all nEXT turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decrease downtime. nEXT D turbo pumps benefit from a compact onboard controller which has drive electronics for controlling pump operation and standby speed, and operating solenoid vent valves (TAV5, TAV6) and air-cooling units (via the 24 VDC accessory port). The integral controller has a DB15 interface for RS232 and RS485 serial communications and for supplying pump power. The USB port allows the use of Edwards nST2 PC software (free download from link below). The controller also has five indicator LED’s which signal the general status, operation, and service status of the pump. The optional TIC turbo instrument controller, or TAG turbo and active gauge controller can both power and control the pump. Edwards nEXT pumps with a CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO or KF flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat flanged nEXT85D pumps can be baked up to 120 °C when the turbo is water cooled. Heater bands for the Conflat pumps are sold separately. For vacuum system integration applications, the nEXT85D pump can be powered by a suitable user supplied 24 to 48 VDC power source. For laboratory applications we recommend the Edwards TIC turbo instrument controller or the TAG turbo & active gauge controller, either of which can both supply power and control the pump. The TIC series of controllers are bench top or rack mountable remote user interface/power sources, which communicate with the Edwards nEXT series pumps through RS232/RS485 and provide full monitoring and control of the turbo pump, and optionally for one or more vacuum gauge instruments. When an Edwards relay box is added, it becomes the control interface between the TIC controller and the mains backing pump, turbo pump flange heater band, and a backing line isolation valve. The TAG turbo and active gauge controller can power nEXT85D turbo pumps and a vacuum gauge, and its large LED display can show pump speed or vacuum pressure. The pump instruction manual and Edwards nEXT pump product brochures are available in the downloads section. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments

Condition: New



Part Number: P109212



Price: Kr42,533.31


Regular Price: Kr60,761.83




Currency: Danish Krone (DKK)

Edwards TAG Turbo and Active Gauge Controller Kit with 200W External 24 VDC Power Supply and 2m AC Power Cord for nEXT Turbo Pumps.
In Stock
3


Edwards TAG Turbo and Active Gauge Controller Kit with 200W External 24 VDC Power Supply and AC Power Cord for nEXT Turbo Pumps. This Edwards TAG Turbo and Active Gauge Controller Kit includes the TAG controller, the matching 200W power supply, and a 2 meter long, US plug 5-15P to C13 Connector, IEC 60320 input power cord for the power supply. The TAG is a small, low cost, 24 VDC pumping system controller, suitable for a wide range of vacuum applications. The TAG provides a serial interface for displaying the turbo pump’s speed and can power nEXT85D, nEXT240D, nEXT300D, or nEXT400D turbo pumps. The TAG can also control and display vacuum pressure of a single active gauge, and run a fan for forced air cooling of the pump. The TAG controller is compatible with all nEXT turbo pumps and APG, AIM, ASG, or WRG vacuum gauges. The TAG’s push button interface allows the user to easily switch between between pump speed or vacuum pressure, shown on the large LED display. This compact 24 VDC controller is ideal for use on benchtops and is also well suited for mobile platforms where space is limited, yet functionality and reliability are essential. This TAG Controller Kit includes: Edwards TAG Turbo and Active Gauge Controller, PN: D39592000 Edwards 200W External Power Supply for TAG Controller, PN: D39592800 AC Power Cord, 2 Meters Long, 115 VAC, US Plug 5-15P to C13, PN: P106129

Condition: New



Part Number: P106255



Price: Kr12,231.05


Regular Price: Kr14,389.46




Currency: Danish Krone (DKK)

Edwards TAG Turbo and Active Gauge Controller Without 24 VDC Power Supply Used With nEXT Turbo Pumps. PN: D39592000
In Stock
3
Expecting 12
Anticipated Arrival 12 on 2024-12-13


Edwards TAG Turbo and Active Gauge Controller, 24 VDC, Without Power Supply, for nEXT Turbo Pumps. Edwards Part Number: D39592000. The TAG is a small, low cost, 24 VDC pumping system controller, suitable for a wide range of vacuum applications. The TAG provides a serial interface for displaying the turbo pump’s speed and can power nEXT85D, nEXT240D, nEXT300D, or nEXT400D turbo pumps. The TAG can also control and display vacuum pressure of a single active gauge, and run a fan for forced air cooling of the pump. The TAG controller is compatible with all nEXT turbo pumps and APG, AIM, ASG, or WRG vacuum gauges. The TAG’s push button interface allows the user to easily switch between between pump speed or vacuum pressure, shown on the large LED display. This compact 24 VDC controller is ideal for use on benchtops and is also well suited for mobile platforms where space is limited, yet functionality and reliability are essential. This listing is for the TAG controller only. It requires the 24 VDC power supply (part number P106340) and a standard AC power cord (part number P106129). Also available is part number P106255, a TAG controller kit that includes the power supply and AC power cord.

Condition: New



Part Number: P106256



Price: Kr6,335.04


Regular Price: Kr7,452.97




Currency: Danish Krone (DKK)

Edwards 200W External Power Supply with 24 VDC Output for Edwards TAG Turbo and Active Gauge Controller. PN: D39592800
In Stock
12


Edwards 200W External Power Supply, 24 VDC, for Edwards TAG Turbo and Active Gauge Controller. Edwards Part Number: D39592800. This Edwards 200W external power supply provides 24 VDC @8A to the TAG turbo and active gauge controller (part number P106255). The external 200W power supply is required since the TAG does not have its own internal power supply. This power supply comes with a permanently attached cable that connects to the TAG controller. The input AC cable for this power supply is sold separately (part number P106129). This 200W Edwards power supply has part number D39592800. This power supply is for: TAG Turbo and Active Gauge Controller

Condition: New



Part Number: P106340



Price: Kr5,561.91


Regular Price: Kr6,543.41




Currency: Danish Krone (DKK)

Input Power Cord Mains Cable 2m Long 115 VAC for Edwards TIC Controller, Relay Box, TAG Power Supply. US Plug.
In Stock
98


Input Power Cord Mains Cable 2m Long 115 VAC for Edwards TIC Controller, Relay Box, or TAG Power Supply US Plug. This is an input power cord (mains cable), 115 VAC, 2 meters long, with US plug 5-15P to C13 Connector. It is used on the Edwards TIC turbo instrument controller and TIC relay box. It is also used on the 200W external power supply (part number P106340) which powers the TAG turbo and active gauge controller (the TAG does not have an internal power supply). Replaces Edwards part number B8J200813, A50507000 or D40013120, and is the same as our part number P102990). This power cord is used on: Edwards TIC Turbo Instrument Controller Edwards TIC Relay Box Edwards TAG Turbo and Active Gauge Controller 200W External Power Supply Edwards nXDSi Dry Scroll Pumps

Condition: New



Part Number: P106129



Price: Kr394.71




Currency: Danish Krone (DKK)

Edwards 100W TIC Turbo Instrument Controller Without Vacuum Gauge Support Used With nEXT Turbo Pumps. PN: D39711000
In Stock
2


Edwards 100W TIC Turbo Instrument Controller Without Vacuum Gauge Control, for nEXT Turbo Pumps. Edwards Part Number: D39711000. This Edwards 100W TIC Turbo Instrument Controller can control and power a nEXT85D turbo pump, and is recommended to control nEXT730D, nEXT930D, or nEXT1230H turbo pumps. This controller does not have active gauge support and is Edwards part number D39711000. Edwards TIC Turbo Instrument Controllers are a series of 100W and 200W compact controllers which can be used with any Edwards nEXT turbo pump. The TIC connects to, and controls, the turbo pump through the pump’s attached DB15 serial cable. Through the same cable, the TIC is able to supply 24 VDC pump power to the smaller nEXT pumps. TIC controllers feature a large, clear graphics display, easy-to-use control interface via a touch sensitive keypad, and a DB9 RS232/485 interface for control and data monitoring on a remote PC with user supplied software. TIC’s require 100-240 VAC input power and can be rack mounted or used on a benchtop. The TIC does not come with an input power cable (we suggest part number P106129). All TIC variants have support for a forced air cooling fan and a solenoid operated vent valve through a Phoenix 4 pin connector (mating end is supplied with the TIC). When connected through the DB25 logic interface to an Edwards Relay Box (part number P106081), the TIC can also control a backing pump, flange heater band, and a 24 VDC backing line valve. TIC controllers are available with or without active gauge control. Supported gauges are APG, AIM, ASG, or WRG series gauges (IGC and Barocel models are not supported). About the 100W TIC Turbo Instrument Controller TIC Controller, 100W, no controls for active gauges, part number D39711000 TIC Controller, 100W, controls up to 3 active gauges, part number D39721000 Controls AND can supply power to nEXT85D turbo pumps Recommended to control nEXT730D, nEXT930D, or nEXT1230H turbo pumps Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve About the 200W TIC Turbo Instrument Controller TIC Controller, 200W, no controls for active gauges, part number D39712000 TIC Controller, 200W, controls up to 3 active gauges, part number D39722000 Controls AND can supply power to nEXT230D, nEXT300D, or nEXT400D turbo pumps Faster ramp speed of nEXT85D turbo pumps (compared to 100W TIC) Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve

Condition: New



Part Number: P106128



Price: Kr16,334.34


Regular Price: Kr19,216.89




Currency: Danish Krone (DKK)

Edwards 200W TIC Turbo Instrument Controller Without Vacuum Gauge Support Used With nEXT Turbo Pumps. PN: D39712000
In Stock
8


Edwards 200W TIC Turbo Instrument Controller Without Vacuum Gauge Support, for nEXT Turbo Pumps. Edwards Part Number: D39712000. This Edwards 200W TIC Turbo Instrument Controller can control and power a nEXT230D, nEXT300D, or nEXT400D turbo pump. This controller does not have active gauge support and is Edwards part number D39712000. Edwards TIC Turbo Instrument Controllers are a series of 100W and 200W compact controllers which can be used with any Edwards nEXT turbo pump. The TIC connects to, and controls, the turbo pump through the pump’s attached DB15 serial cable. Through the same cable, the TIC is able to supply 24 VDC pump power to the smaller nEXT pumps. TIC controllers feature a large, clear graphics display, easy-to-use control interface via a touch sensitive keypad, and a DB9 RS232/485 interface for control and data monitoring on a remote PC with user supplied software. TIC’s require 100-240 VAC input power and can be rack mounted or used on a benchtop. The TIC does not come with an input power cable (we suggest part number P106129). All TIC variants have support for a forced air cooling fan and a solenoid operated vent valve through a Phoenix 4 pin connector (mating end is supplied with the TIC). When connected through the DB25 logic interface to an Edwards Relay Box (part number P106081), the TIC can also control a backing pump, flange heater band, and a 24 VDC backing line valve. TIC controllers are available with or without active gauge control. Supported gauges are APG, AIM, ASG, or WRG series gauges (IGC and Barocel models are not supported). About the 100W TIC Turbo Instrument Controller TIC Controller, 100W, no controls for active gauges, part number D39711000 TIC Controller, 100W, controls up to 3 active gauges, part number D39721000 Controls AND can supply power to nEXT85D turbo pumps Recommended to control nEXT730D, nEXT930D, or nEXT1230H turbo pumps Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve About the 200W TIC Turbo Instrument Controller TIC Controller, 200W, no controls for active gauges, part number D39712000 TIC Controller, 200W, controls up to 3 active gauges, part number D39722000 Controls AND can supply power to nEXT230D, nEXT300D, or nEXT400D turbo pumps Faster ramp speed of nEXT85D turbo pumps (compared to 100W TIC) Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve

Condition: New



Part Number: P105874



Price: Kr17,475.71


Regular Price: Kr20,559.61




Currency: Danish Krone (DKK)

Edwards 100W TIC Turbo Instrument Controller With Support for 3 Active Vacuum Gauges Used With nEXT Turbo Pumps. PN: D39721000
In Stock
3
Expecting 3
Anticipated Arrival 1 on 2024-11-01


Edwards 100W TIC Turbo Instrument Controller With Support for 3 Active Vacuum Gauges, for nEXT Turbo Pumps. Edwards Part Number: D39721000. This Edwards 100W TIC Turbo Instrument Controller can control and power a nEXT85D turbo pump, and is recommended to control nEXT730D, nEXT930D, or nEXT1230H turbo pumps. This controller has support for up to 3 active vacuum gauges and is Edwards part number D39721000. Edwards TIC Turbo Instrument Controllers are a series of 100W and 200W compact controllers which can be used with any Edwards nEXT turbo pump. The TIC connects to, and controls, the turbo pump through the pump’s attached DB15 serial cable. Through the same cable, the TIC is able to supply 24 VDC pump power to the smaller nEXT pumps. TIC controllers feature a large, clear graphics display, easy-to-use control interface via a touch sensitive keypad, and a DB9 RS232/485 interface for control and data monitoring on a remote PC with user supplied software. TIC’s require 100-240 VAC input power and can be rack mounted or used on a benchtop. The TIC does not come with an input power cable (we suggest part number P106129). All TIC variants have support for a forced air cooling fan and a solenoid operated vent valve through a Phoenix 4 pin connector (mating end is supplied with the TIC). When connected through the DB25 logic interface to an Edwards Relay Box (part number P106081), the TIC can also control a backing pump, flange heater band, and a 24 VDC backing line valve. TIC controllers are available with or without active gauge control. Supported gauges are APG, AIM, ASG, or WRG series gauges (IGC and Barocel models are not supported). About the 100W TIC Turbo Instrument Controller TIC Controller, 100W, no controls for active gauges, part number D39711000 TIC Controller, 100W, controls up to 3 active gauges, part number D39721000 Controls AND can supply power to nEXT85D turbo pumps Recommended to control nEXT730D, nEXT930D, or nEXT1230H turbo pumps Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve About the 200W TIC Turbo Instrument Controller TIC Controller, 200W, no controls for active gauges, part number D39712000 TIC Controller, 200W, controls up to 3 active gauges, part number D39722000 Controls AND can supply power to nEXT230D, nEXT300D, or nEXT400D turbo pumps Faster ramp speed of nEXT85D turbo pumps (compared to 100W TIC) Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve

Condition: New



Part Number: P106074



Price: Kr19,853.38


Regular Price: Kr23,356.92




Currency: Danish Krone (DKK)

Edwards 200W TIC Turbo Instrument Controller With Support for 3 Active Vacuum Gauges Used With nEXT Turbo Pumps. PN: D39722000
In Stock
7


Edwards 200W TIC Turbo Instrument Controller With Support for 3 Active Vacuum Gauges, for nEXT Turbo Pumps. Edwards Part Number: D39722000. This Edwards 200W TIC Turbo Instrument Controller can control and power a nEXT230D, nEXT300D, or nEXT400D turbo pump. This controller has support for up to 3 active vacuum gauges and is Edwards part number D39722000. Edwards TIC Turbo Instrument Controllers are a series of 100W and 200W compact controllers which can be used with any Edwards nEXT turbo pump. The TIC connects to, and controls, the turbo pump through the pump’s attached DB15 serial cable. Through the same cable, the TIC is able to supply 24 VDC pump power to the smaller nEXT pumps. TIC controllers feature a large, clear graphics display, easy-to-use control interface via a touch sensitive keypad, and a DB9 RS232/485 interface for control and data monitoring on a remote PC with user supplied software. TIC’s require 100-240 VAC input power and can be rack mounted or used on a benchtop. The TIC does not come with an input power cable (we suggest part number P106129). All TIC variants have support for a forced air cooling fan and a solenoid operated vent valve through a Phoenix 4 pin connector (mating end is supplied with the TIC). When connected through the DB25 logic interface to an Edwards Relay Box (part number P106081), the TIC can also control a backing pump, flange heater band, and a 24 VDC backing line valve. TIC controllers are available with or without active gauge control. Supported gauges are APG, AIM, ASG, or WRG series gauges (IGC and Barocel models are not supported). About the 100W TIC Turbo Instrument Controller TIC Controller, 100W, no controls for active gauges, part number D39711000 TIC Controller, 100W, controls up to 3 active gauges, part number D39721000 Controls AND can supply power to nEXT85D turbo pumps Recommended to control nEXT730D, nEXT930D, or nEXT1230H turbo pumps Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve About the 200W TIC Turbo Instrument Controller TIC Controller, 200W, no controls for active gauges, part number D39712000 TIC Controller, 200W, controls up to 3 active gauges, part number D39722000 Controls AND can supply power to nEXT230D, nEXT300D, or nEXT400D turbo pumps Faster ramp speed of nEXT85D turbo pumps (compared to 100W TIC) Use Relay Box (P106081) to control backing pump, heater band and backing isolation valve

Condition: New



Part Number: P106075



Price: Kr23,819.24


Regular Price: Kr28,022.64




Currency: Danish Krone (DKK)

Edwards 1m Long DB15 Extension Power and Communication Cable Connects TIC or TAG Controller to any nEXT Turbo Pump. PN: D39700835
In Stock
1


Edwards Extension Power and Communication Cable Connects TIC or TAG Controller to any nEXT Turbo Pump, D-Sub 15 pin, 1 m Long. Edwards Part Number: D39700835. This Edwards 1m long extension power and communication cable connects between any nEXT turbo pump and either the TIC (Turbo Instrument Controller) or TAG (Turbo & Active Gauge Controller). It is used to increase the distance between the pump and controller. This extension cable has D-Sub 15 pin connectors on either end, one male, one female. Edwards nEXT Turbo pumps have a permanently attached 0.3m long power and communication cable. This 1 meter extension cable increases the overall length of the pump-to-controller cable to 1.3 meters. This 1 meter long extension power and communication cable has Edwards part number D39700835. This Edwards extension power and communication cable is compatible with TIC or TAG Controllers and these nEXT pumps: nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P106354



Price: Kr4,059.32




Currency: Danish Krone (DKK)

Edwards 2m Long DB15 Extension Power and Communication Cable Connects TIC or TAG Controller to any nEXT Turbo Pump. PN: D39700836
In Stock
10


Edwards Extension Power and Communication Cable Connects TIC or TAG Controller to any nEXT Turbo Pump, D-Sub 15 pin, 2 m Long. Edwards Part Number: D39700836. This Edwards 2m long extension power and communication cable connects between any nEXT turbo pump and either the TIC (Turbo Instrument Controller) or TAG (Turbo & Active Gauge Controller). It is used to increase the distance between the pump and controller.This extension cable has D-Sub 15 pin connectors on either end, one male, one female. Edwards nEXT Turbo pumps have a permanently attached 0.3m long power and communication cable. This 2 meter extension cable increases the overall length of the pump-to-controller cable to 2.3 meters. This 2 meter long extension power and communication cable has Edwards part number D39700836. This Edwards extension power and communication cable is compatible with TIC or TAG Controllers and these nEXT pumps: nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P106079



Price: Kr4,436.19




Currency: Danish Krone (DKK)

Edwards 5m Long DB15 Extension Power and Communication Cable Connects TIC or TAG Controller to any nEXT Turbo Pump. PN: D39700837
In Stock
3


Edwards Extension Power and Communication Cable Connects TIC or TAG Controller to any nEXT Turbo Pump, D-Sub 15 pin, 5 m Long. Edwards Part Number: D39700837. This Edwards 5m long extension power and communication cable connects between any nEXT turbo pump and either the TIC (Turbo Instrument Controller) or TAG (Turbo & Active Gauge Controller). It is used to increase the distance between the pump and controller. This extension cable has D-Sub 15 pin connectors on either end, one male, one female. Edwards nEXT Turbo pumps have a permanently attached 0.3m long power and communication cable. This 5 meter extension cable increases the overall length of the pump-to-controller cable to 5.3 meters. This 5 meter long extension power and communication cable has Edwards part number D39700837. This Edwards extension power and communication cable is compatible with TIC or TAG Controllers and these nEXT pumps: nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P106361



Price: Kr5,171.16




Currency: Danish Krone (DKK)

Edwards 2m Long DB25 Logic Interface Cable Connects TIC Controller to TIC Relay Box. PN: D39700833
In Stock
1


Edwards Logic Interface Cable, Connects between TIC Controller and TIC Relay Box, 25 Pin D-Sub, 2 m Long. Edwards Part Number: D39700833. This Edwards logic interface cable interconnects a TIC Turbo Instrument Controller and a TIC Relay box. This male-to-female 25 pin D-Sub cable is 2 meters long. It allows the TIC to control powering the backing pump, an intake flange heater band (bakeout band), and an isolation valve. This logic interface cable has Edwards part number D39700833. This logic interface cable is compatible with: TIC Turbo Instrument Controller (P106075, P105874, P106074, P106128) TIC Relay Box (P106081) The TIC Turbo Instrument Controller and TIC Relay Box are compatible with these turbo pumps: nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P106082



Price: Kr754.16




Currency: Danish Krone (DKK)

Edwards TIC Relay Box Without Setpoints Allows TIC Controller To Control Backing Pump Flange Heater Band and Isolation Valve. PN: D39711805
In Stock
1


Edwards TIC Relay Box, Allows TIC To Control Backing Pump, Flange Heater Band and Isolation Valve, No Setpoints. Edwards Part Number: D39711805. This Edwards TIC relay box acts as the control interface between the TIC controller and the mains backing pump, turbo pump flange heater band, and a backing line isolation valve. This relay box does not have any setpoint relays. The relay box can be used on a benchtop or rack mounted alongside the TIC controller. The TIC relay box connects to the the TIC Turbo Instrument Controller with the 25 pin D-Sub, logic interface cable (part number P1012534). The relay box accepts input power from100-240 VAC. The Edwards input (mains) power cable (part number P106129) is sold separately. Maximum rating for powering the backing pump is 240 VAC@10A, and 240 VAC@1A for the heater (bakeout) band. The backing pump and heater band connections are individually fused. Note that the backing pump and heater band must be rated for the same voltage as the input voltage supplied to the relay box. The isolation valve control has a maximum rating of 24 VDC@0.5A and is energised whenever the backing pump is running. This Edwards relay box has part number D39711805. The TIC Relay Box and the TIC Turbo Instrument Controller are compatible with these turbo pumps: nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P106081



Price: Kr8,518.30




Currency: Danish Krone (DKK)

Edwards ACX85 Combination Axial or Radial Forced Air Cooling Kit for nEXT Turbo Pumps. PN: B8G200820
In Stock
10


Edwards ACX85 Combination Axial / Radial Forced Air Cooling Kit for nEXT85D Turbo Pumps. Edwards Part Number: B8G200820. This Edwards ACX85 forced air cooling kit is specifically designed for nEXT85D series turbo pumps which require either forced air or water cooling. The ACX85 forced air cooling kit is specifically designed for nEXT85D turbo pumps. This kit can be either Axially or Radially mounted and has a 0.3 meter long power cable terminated with an accessory port connector. The fan plugs into the pump’s accessory port and is powered by the pump. This kit includes all the necessary hardware to mount the fan in either orientation. When mounted axially, the fan unit mounts to the bottom of the pump and provides forced air flow colinear to the pump’s shaft. When mounted radially, the fan unit mounts to the side of, and provides forced air flow perpendicular to, the pump. This Edwards combination axial/radial forced air cooling kit has part number B8G200820. This combination Axial/Radial fan kit fits: nEXT85D Turbo Pumps

Condition: New



Part Number: P109582



Price: Kr4,992.39




Currency: Danish Krone (DKK)

Edwards WCX85 Water Cooling Kit for nEXT Turbo Pumps with Push-Fit Connectors for 6mm OD Hose and G 1/8 in. Fittings. PN: B8G200833
In Stock
4


Edwards WCX85 Water Cooling Kit for nEXT85D Turbo Pumps. Edwards Part Number: B8G200833. This Edwards water cooling unit fits the nEXT85D turbo pump. It attaches to the side of the pump with two included bolts. This water cooling block has push-fit connectors for the supply and discharge hoses (6mm OD plastic hose). The hose connections may be unscrewed and removed to make use of the integrated G 1/8” threads. This water cooling kit is needed when using a flange heater band with a CF flanged pump. Edwards nEXT85D pumps also benefit from water cooling when there are high gas throughputs, cyclic operations and/or high ambient temperatures. In order to ensure long trouble-free operation, the cooling water must be clean and not contain any oils, greases or suspended solids. This water cooling kit has Edwards part number B8G200833. This water cooling unit fits: nEXT85D turbo pumps

Condition: New



Part Number: P1012512



Price: Kr3,139.48




Currency: Danish Krone (DKK)

Edwards 110 VAC Flange Heater Band for nEXT Turbo Pumps with CF 4.5 in. DN 63 CF Inlet Flange. PN: B8G200823
In Stock
2


Edwards Intake Flange Heater Band, CF 4.5 Inch, DN 63 CF, 110 VAC, for nEXT85D Turbo Pumps. Edwards Part Number: B8G200823. This is a 110 VAC Edwards intake flange heater for nEXT85D turbo pumps with CF 4.5 inch flange (DN 63 CF). This heater band may only be used on CF flanged pumps outfitted with either water cooling or forced air cooling. The intake flange may be baked up to 120 °C if the turbo pump is water cooled, 115 °C if the turbo pump is fan cooled. This flange heater (bakeout band) accelerates the degassing of the pump to enable it to achieve lower pressures. It may also be used to protect the pump from condensation of contaminants. The band heater has an attached power cable terminated with a C19 power entry plug (male C19). This Edwards intake bakeout flange heater band has part number 800137V0004. We recommend using the Ideal Vacuum PID plug and play heater controller (part number P107361). The heater band power cable will plug directly into it. The input voltage of the controller must be the same as the heater. The P107361 controller includes a 115 VAC input power cable with a 5-20P (20A) plug. Heater Band Specs: Fits: nEXT85D turbo pump with CF 4.5 in. flange (P109212) and cooling option (required) Water Cooling Option: P1012512 Forced Air Cooling Option: P109582 Heater Band Voltage: 110 VAC Recommended Controller: Ideal Vacuum P107361 (115 VAC power cord with 5-20P plug included)

Condition: New



Part Number: P1012513



Price: Kr8,331.89




Currency: Danish Krone (DKK)

Edwards 240 VAC Flange Heater Band for nEXT Turbo Pumps with CF 4.5 in. DN 63 CF Inlet Flange. PN: B8G200824
Out of Stock


Edwards Flange Heater Band, CF 4.5", DN 63 CF, 240 VAC, for nEXT85D Turbo Pumps. Edwards Part Number: B8G200824. This is a 240 VAC Edwards intake flange heater for the nEXT85D turbo pump with CF 4.5 inch flange (DN 63 CF). This heater band may only be used on CF flanged pumps outfitted with either water cooling or forced air cooling. The intake flange may be baked up to 120 °C if the turbo pump is water cooled, 115 °C if the turbo pump is fan cooled. This flange heater (bakeout band) accelerates the degassing of the pump to enable it to achieve lower pressures. It may also be used to protect the pump from condensation of contaminants. The band heater has an attached power cable terminated with a C19 power entry plug (male C19). This Edwards intake bakeout flange heater band has part number B8G200824. We recommend using the Ideal Vacuum PID plug and play heater controller (part number P107361). The heater band power cable will plug directly into it. Our P107361 controller can be operated at 100-240 VAC. The input voltage of the controller must be the same as the heater. For use with 240 volt applications you must supply your own power cord. Heater Band Specs: Fits: nEXT85D turbo pump with CF 4.5 in. flange (P109212) and cooling option (required) Water Cooling Option: P1012512 Forced Air Cooling Option: P109582 Heater Band Voltage: 240 VAC Recommended Controller: Ideal Vacuum P107361 (requires customer supplied power cable)

Condition: New



Part Number: P1012514



Price: Kr8,331.89




Currency: Danish Krone (DKK)

Edwards Oil Cartridge Kit for nEXT Turbo Pumps. PN: B8G200828
In Stock
4


Edwards Oil Cartridge Kit for nEXT85D Turbo Pumps. Edwards Part Number: B8G200828. This is an Edwards replacement oil cartridge for nEXT85D turbo pumps. It provides lubrication for the bearing at the bottom of the pump. The oil cartridge can be replaced on-site. Access to the oil cartridge is gained by removal of the four M4 button head screws at the base of the pump. Download the service toolkit manual and follow the instructions for replacing the oil cartridge. This Edwards oil cartridge has part number B8G200828. It is recommended to change both the oil cartridge and bearing at the same time. The bearing and oil cartridge (part number P1012516) can be serviced on-site by any service engineer trained by Edwards, and requires the Edwards bearing replacement tool kit (part number P1012517). Follow the service interval specified in the pump’s manual. This oil cartridge fits: Fits: nEXT85D turbo pumps

Condition: New



Part Number: P1012515



Price: Kr3,220.27




Currency: Danish Krone (DKK)

Edwards Bearing and Oil Cartridge Kit for nEXT Turbo Pumps. PN: B8G200811
In Stock
2


Edwards Bearing and Oil Cartridge Kit for nEXT85D Turbo Pumps. Edwards Part Number: B8G200811. This is an Edwards replacement bearing and oil cartridge kit for nEXT85D turbo pumps. The bearing and oil cartridge are typically replaced at the same time and can be serviced on-site by any service engineer trained by Edwards. Oil cartridge replacement does not require any special tools. Replacement of the bearing, however, requires the specialized Edwards bearing replacement tool kit (part number P1012517). Follow the service interval specified in the pump’s manual and the installation instructions in the service manual. This Edwards bearing and oil cartridge kit has part number B8G200811. This bearing and oil cartridge kit fits: Fits: nEXT85D turbo pumps

Condition: New



Part Number: P1012516



Price: Kr7,877.21




Currency: Danish Krone (DKK)

Edwards Bearing Tool Kit for nEXT Turbo Pumps. PN: B8G200845
In Stock
2


Edwards Bearing Tool Kit for nEXT85D Turbo Pumps. Edwards Part Number: B8G200845. This is an Edwards bearing replacement tool kit for nEXT85D turbo pumps. This tool kit is required to remove and replace the bearing at the base of the pump (bearing and oil cartridge kit part number P1012516). Follow the service interval specified in the pump’s manual and the installation instructions in the service manual. This Edwards bearing replacement tool kit has part number B8G200845. This bearing replacement tool kit is used on: nEXT85D turbo pumps

Condition: New



Part Number: P1012517



Price: Kr6,705.96




Currency: Danish Krone (DKK)

Edwards Accessory Y Connector for nEXT Turbo Pump Accessories. PN: B8G200837
In Stock
1


Edwards Accessory Y Connector for nEXT85D, nEXT730D, nEXT930D and nEXT1230H Turbo Pump Accessories. Edwards Part Number: B8G200837. This Edwards Accessory Y Connector attaches to the accessory port on a nEXT85D, nEXT730D, nEXT930D, and nEXT1230H turbo pump and allows two accessories to be connected simultaneously. Both devices are switched parallelly (i.e. de-energized active / in-active). The pump’s accessories interface is instantly ready for operation with the connected device (energized with pump switched on). Secondary devices, such as air cooling units, venting or purge valves, and relays can be directly energized and activated via the accessory connection. Note that this Y connector cannot be used on nEXT 240D, nEXT300D, or nEXT400D pumps which have a 3 pin Phoenix connector socket instead of a 4 pin accessory port. This Y Connector has Edwards part number B8G200837. The Edwards accessory Y connector is compatible with: nEXT85D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P1012518



Price: Kr1,207.49




Currency: Danish Krone (DKK)

Edwards 0.2m Long Male-to-Female Accessory Port Extension Cable for nEXT Turbo Pump Accessories. PN: B8G200836
In Stock
1


Edwards Accessory Extension Cable for nEXT85D, nEXT730D, nEXT930D and nEXT1230H Turbo Pump Accessories, 0.2 m Long. Edwards Part Number: B8G200836. This Edwards accessory extension cable attaches to the accessory port, or the accessory Y connector (part number P1012518) on a nEXT85D, nEXT730D, nEXT930D, or nEXT1230H turbo pumps. It extends the distance of the accessory to the pump by 0.2 meters. The cable has one straight female connector, and one right angled male connector for installation where space is limited. Devices, such as air cooling units, venting or purge valves, and relays can be directly energized and activated via the accessory connection. Note that this Y connector cannot be used on nEXT 240D, nEXT300D, or nEXT400D pumps which have a 3 pin Phoenix connector socket. This accessory extension cable has Edwards part number B8G200836. The Edwards accessory extension cable is compatible with: nEXT85D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P1012519



Price: Kr1,328.14




Currency: Danish Krone (DKK)

Edwards 1.5m Long Accessory Extension Cable with Unterminated Bare Wire End for nEXT Turbo Pump Accessories. PN: B8G200839
In Stock
1


Edwards Accessory Extension Cable with Bare Wire End for nEXT85D, nEXT730D, nEXT930D and nEXT1230H Turbo Pump Accessories, 1.5 m Long. Edwards Part Number: B8G200839. This Edwards accessory extension cable attaches on one end of a nEXT85D, nEXT730D, nEXT930D, or nEXT1230H turbo pump’s accessory port, or the accessory Y connector (part number P1012518). The other end of the cable is unterminated with bare wires. This cable extends the distance of the accessory to the pump by 1.5 meters and enables the use of accessories that are not prewired with a mating accessory plug. Devices, such as air cooling units, venting or purge valves, and relays can be directly energized and activated via the accessory connection. Note that this Y connector cannot be used on nEXT 240D, nEXT300D, or nEXT400D pumps which have a 3 pin Phoenix connector socket instead of a 4 pin accessory port. This accessory extension cable (male accessory connector to bare wire) has Edwards part number B8G200839. The Edwards accessory extension cable (accessory connector to bare wire) is compatible with: nEXT85D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P1012520



Price: Kr1,086.78




Currency: Danish Krone (DKK)

Edwards TAV5 24 VDC Normally Open NO Venting Valve with Accessory Connector for nEXT Turbo Pumps with G 1/8 in. Fitting. PN: B8G200834
In Stock
1


Edwards TAV5 Venting Valve, Accessory Connector, for nEXT85D, nEXT730D, nEXT930D, and nEXT1230H Turbo Pumps, 24 VDC, Normally Open (NO), G 1/8 in. Fitting. Edwards Part Number: B8G200834. This Edwards TAV5 venting valve can be used on the nEXT85D, nEXT730D, nEXT930D, and nEXT1230H turbo pumps. This is a normally open (NO) valve and operates at 24 VDC. This TAV5 solenoid valve comes with a 0.3 meter long power cable, terminated with an accessory connector for connection to the pump’s accessory port, and has a G 1/8" (BSPP) fitting for connection into the pump’s vent port. This valve is configured to be driven by the pump’s onboard controller. This normally open valve can be used as a power failure venting valve. When a power failure occurs, this valve closes and vents the pump and the forevacuum line and thus keeps oil vapor from diffusing back from the forevacuum line. For use on nEXT 240D, nEXT300D, or nEXT400D pumps which have a 3 pin Phoenix connector socket instead of a 4 pin accessory port, use TAV5 valve part number P105358. TAV5 vent valves have an 0.5mm diameter orifice and are suitable for venting small vacuum systems of <5 liters (for larger system volumes, use the TAV6 venting valve with an orifice of 1.0mm, part number P106355). The TAV5 vent valve can replace the manual vent valve that is furnished with the turbo pump, or be fitted into any other suitable port on the vacuum system upstream of the turbomolecular pump. The valve is supplied with a 0.3 meter power cord terminated with an accessory connector, a sintered bronze inlet-filter, a riffled hose connector for attaching to a dry nitrogen supply, and a DN10NW adapter for optional direct connection to the vacuum system. This TAV5 normally open (NO) solenoid venting valve has Edwards part number B8G200834. This TAV5 normally open venting valve is suitable for use on: nEXT85D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P1012197



Price: Kr7,060.18




Currency: Danish Krone (DKK)

Edwards TAV6 Purge Vent-Valve Kit, 24 VDC, with 3m Long Unterminated Wire for any nEXT Turbo Pump with BSP 1/8 in. Fitting. PN: B58066020
In Stock
2


Edwards TAV5 Purge Vent-Valve Kit, 24 VDC, with 3m Long Unterminated Wire for any nEXT Turbo Pump with BSP 1/8 in. Fitting. Edwards Part Number: B58066020. This Edwards TAV6 venting valve can be installed in any nEXT85D, 240D, 300D, 400D, 730D, 930D, or 1230H series turbo pump. This valve operates at 24 VDC, and comes with a 3 meter long power cable with unterminated (bare wire) end, and has a BSP 1/8" fitting for connection into the pump’s vent port. This valve can be powered by the pump’s accessory port (nEXT85D, nEXT730D, nEXT930D, or nEXT1230H) or the 3 pin Phoenix connector socket on nEXT240D, nEXT300D, or nEXT400D pumps (the mating phoenix plug is supplied with the pump). This valve can also be directly wired to a TIC Controller, or a separate 24 VDC power supply. For use with a nEXT85D, nEXT730D, nEXT930D, or nEXT1230H turbo pump, the accessory extension cable is required (part number P1012520), which has an accessory connector on one end and is unterminated on the other. This normally open valve can be used as a power failure venting valve. When a power failure occurs, this valve closes and vents the pump and the forevacuum line and thus keeps oil vapor from diffusing back from the forevacuum line. . TAV6 vent valves have an 1.0 mm diameter orifice and are suitable for venting vacuum systems large than 5 liters. For smaller volume vacuum systems of <5 liters, use the TAV5 venting valve with an orifice of 0.5 mm (part number P105358). The TAV6 vent valve can replace the manual vent valve that is furnished with the turbo pump, or be fitted into any other suitable port on the vacuum system upstream of the turbomolecular pump. This valve is supplied with a 3 meter long unterminated cable, a sintered bronze inlet-filter, a riffled hose connector for attaching to a dry nitrogen supply, and a DN10NW adapter for optional direct connection to the vacuum system. This TAV6 venting valve with unterminated power cable has Edwards part number B58066020. This TAV6 venting valve with bare wire cable is suitable for use on these turbo pumps: nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P106355



Price: Kr6,126.75




Currency: Danish Krone (DKK)

Edwards TAV5 24 VDC Normally Closed NC Venting Valve with Accessory Connector for nEXT Turbo Pumps with G 1/8 in. Fitting. PN: B8G200835
In Stock
1


Edwards TAV5 Venting Valve, Accessory Connector, for nEXT85D, nEXT730D, nEXT930D, and nEXT1230H Turbo Pumps, 24 VDC, Normally Closed (NC), G 1/8 in. Fitting. Edwards Part Number: B8G200835. This Edwards TAV5 venting valve can be used on the nEXT85D, nEXT730D, nEXT930D, and nEXT1230H turbo pumps. This is a normally closed (NC) valve and operates at 24 VDC. This TAV5 solenoid valve comes with a 0.3 meter long power cable, terminated with an accessory connector for connection to the pump’s accessory port, and has a G 1/8" (BSPP) fitting for connection into the pump’s vent port. This valve is configured to be driven by the pump’s onboard controller. This valve cannot be used on nEXT 240D, nEXT300D, or nEXT400D pumps which have a 3 pin Phoenix connector socket instead of a 4 pin accessory port. TAV5 vent valves have an 0.5mm diameter orifice and are suitable for venting small vacuum systems of <5 liters (for larger system volumes, use the TAV6 venting valve with an orifice of 1.0mm, part number P106355).The TAV5 vent valve can replace the manual vent valve that is furnished with the turbo pump, or be fitted into any other suitable port on the vacuum system upstream of the turbomolecular pump. The valve is supplied with a 0.3 meter power cord terminated with an accessory connector, a sintered bronze inlet-filter, a riffled hose connector for attaching to a dry nitrogen supply, and a DN10NW adapter for optional direct connection to the vacuum system. This TAV5 normally closed (NC) solenoid venting valve has Edwards part number B8G200835. This TAV5 normally closed venting valve is suitable for use on: nEXT85D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P1012521



Price: Kr9,767.71




Currency: Danish Krone (DKK)

Edwards Vent or Purge Port Adapter with G 1/8 in. Fitting to KF-10 Flange for any nEXT Turbo Pump. PN: B58066011
In Stock
3


Edwards Vent or Purge Port Adapter, G 1/8 in. to KF10 for any nEXT Turbo Pumps. Edwards Part Number: B58066011 This Edwards vent or purge port adapter is used to convert the G 1/8 inch (BSPP) female vent or purge port on any nEXT turbo pump to a KF10 NW10 flange. An alternative vent valve to the TAV5 or TAV6 valve, or a vent or purge pipeline may then be fitted to this flange. This vent port adapter is supplied with a flow restrictor (when used on the vent port), and an O-ring to seal the adapter to the pump. When used in the purge port, use the PRX10 purge restrictor (part number P1012056) to limit the purge gas flow rate. This adapter has Edwards part number B58066011. This Edwards vent port adapter is suitable for use on these turbo pumps: nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P106356



Price: Kr969.46




Currency: Danish Krone (DKK)

Edwards PRX10 Purge Restrictor for any nEXT Turbo Pump. PN: B58065001
Out of Stock


Edwards PRX10 purge restrictor for any nEXT Series Turbo Pump. Edwards Part Number: B58065001 This Edwards purge gas restrictor sets the flow rate of dry purge gas through the purge port on any nEXT turbo pump. An inert purge gas is used to protect the bearing and motor from corrosion. In order to use this purge restrictor, the vent port adapter (part number P106356) must be used to adapt the G 1/8" (BSPP) purge port to a KF10 NW10 flange. The PRX10 purge restrictor is a special KF10 centering ring with a filter and restrictor built in. This purge restrictor, as supplied, is adjusted to restrict the flow rate of dry nitrogen at a supply pressure of 25 sccm. The supply pressure can be increased to increase the flow rate. Please see the accessories download for additional information about calibrating the purge restrictor. This Edwards PRX10 purge restrictor has part number B58065001. This Edwards PRX10 purge restrictor is suitable for use on these turbo pumps (with P106356 vent adapter): nEXT85D nEXT240D nEXT300D nEXT400D nEXT730D nEXT930D nEXT1230H

Condition: New



Part Number: P1012056



Price: Kr2,165.63




Currency: Danish Krone (DKK)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com