Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-eg
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nXR Multi Stage Roots Pumps On Sale Adixen 2021C2 Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale Edwards nEXT300D TStations On Sale Agilent Varian Helium Leak Detectors On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3

Edwards Replacement Sensor APG100-XLC Active Pirani Gauge NW16, KF16, Corrosion Resistant, 10-4 Torr

Condition:
  New
Part Number:
  P107154
Warranty:
  Full Manufacturer's Warranty

Available Now   1  

Sale: E£34,520.55

Edwards Replacement Sensor APG100-XLC Active Pirani Gauge NW16, KF16, Corrosion Resistant, 10-4 Torr 34520.55
Currency: Egyptian Pound (EGP)

Description

Edwards REPLACEMENT SENSOR for APG100-XLC Active Pirani Vacuum Gauge NW16, KF16 Flange. Corrosion Resistant. 10-4 Torr.
Edwards Part Number D02603801

The Edwards APG100-XLC replacement gauge tube sensors (Corrosion Resistant Platinum/Iridium Filaments) have a NW25 (KF25) vacuum flange and are designed to fit the APG100-XM Active Pirani Electronics housing. They are a cost effective repair solution. The new Edwards gauges are compatible with all Edwards TIC, ADC, TAG instrument controllers and other active gauge controllers and displays. The APG100 is available in two versions: the 'M' version (contains standard Tungsten/Rhenium filaments) can measure pressure down to 10-3 Tor and is suitable for general applications; the 'LC' version (contains corrosive resistance Platinum/Iridium filaments) can measure pressure down to 10-4 Torr and is also suitable for use in corrosive applications.



The APG100 can be mounted in any orientation however the gauge tubes are individually factory calibrated in nitrogen whilst vertical. For correct pressure indication in your chosen gauge orientation, the gauge should be recalibrated at atmospheric pressure. Edwards recommends mounting the gauge tube vertical in order to minimize the build up of process particulates and condensable vapors within the gauge. he APG100 is calibrated for use in nitrogen, and will read correctly with dry air, oxygen and carbon monoxide. For any other gas type a conversion is required in order to obtain the correct pressure reading, common gases: nitrogen, argon, carbon dioxide, helium, krypton and neon.

They are also CSA, C/US approved as well as fully RoHS compliant due to their lead-free construction. Pressure range down to 10-3 Torr. The signal cable and vacuum gauge controller are sold separately. The instruction manual for these Edwards APG100 series gauges is available in PDF format below. These Edwards APG100-XLC Active Pirani Vacuum Gauge replacement sensors have NW16 (KF16) vacuum flange and Edwards part number D02603801.

Features Include:
  • Easy Access to signal cable with compact enclosure
  • Sensor bakable to 150°C (300°F) and sensor is user replaceable
  • Adjustable set point for simple process control and interlocking
  • Remote calibration possible
  • Corrosion Resistant
  • Pressure range 10-4 Torr

Background On Pirani and Convection Enhanced Pirani Gauges
Pirani vacuum gauges can be classified as a thermal conductivity gauge being very similar to the thermocouple gauge where the resistance of the heated wire is measured to determine vacuum pressure. A Pirani gauge is designed to measure the resistance imbalance where the heated filament forms one of the arms of a Wheatstone bridge circuit. As the vacuum pressure increases, gas molecules transport heat away from the filament, and the resistance of the pressure sensor will move to a lower value which unbalances the circuit. The vacuum pressure is therefore calculated from the pressure induced imbalance in the Wheatstone bridge circuit. Just as with the thermocouple gauges, thermal conductivity by molecular collisions increases linearly with pressure over the 0.001 to 1 Torr pressure range. However, the heat removal becomes non-linear as the pressure is further increased into the viscous flow regime, where gas-gas collision can reorient molecules back towards the heated wire. Molecules have to collide many times before they reach the outer body of the sensor (the thermal sink). The convection-enhanced Pirani gauges take advantage of the convention current inside the sensor to extend its pressure measurement range all the way to atmospheric pressure.

The Pirani gauge is an indirect pressure measurement sensors where measured readings are gas-type dependent. Some caution should be advised from the facts that heavier gases have poor heat transfer rates and that the standard convention-enhanced Pirani gauges are calibrated for N2 (basically the same calibration as Air). This could lead to dangerous overpressure conditions when back filling a vacuum systems with a heavier gas like argon. The danger arises if the vacuum system operator does not correct the gauge display reading for the correct gas-type, for example, a standard gauge calibrated for N2, displays 24 Torr when the chamber is at 760 Torr of argon. The operator would be fooled into thinking that the chamber was still under vacuum and continue to increase the system to a critical over-pressured state. Another source of error can be produced if the convection-enhanced Pirani gauge is not mounted correctly, most commercial sensors require that they are mounted parallel to the ground. This keeps the convention current inside the sensor flowing in the designed direction (errors of 20% or more can easily be introduced if the convention-enhanced Pirani sensor is not mount horizontally).

Rapid evacuation of these convection-enhanced Pirani sensors will produce significant measurement error for a short period of several seconds. As the rapidly pumped gases expand, the removal of heat from the pressure sensor filament is not a normal convection current but is instead driven by forced convection. While the vacuum pressure is dropping rapidly the gases expand and cool, this provides a secondary pathway for removing heat from the hot sensor wire. The convection-enhanced Pirani gauge can falsely display high pressures up to 1000 Torr during system evacuation. Once the flow of gases is stopped the pressure reading will again stabilize to a realistic measured value. For these reasons, convection-enhanced Pirani gauges are not well suited for measuring pressure changes under dynamic pumping conditions. Overall, the convection-enhanced Pirani is a popular cost effective rough vacuum pressure gauge which can measures from Atmosphere to 1x10-4 Torr with those measurements below 1 Torr being most accurate.

Brochure

Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 3.1484