Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-eg
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Adixen 2021C2 Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale Agilent Varian Helium Leak Detectors On Sale Edwards nXR Multi Stage Roots Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Agilent Varian HS-2 Water Cooled Diffusion Pump ASA 2 Standard Cold Cap 120V, 450W. PN 82906301
In Stock
2


Agilent Varian HS-2 Water Cooled Vacuum Diffusion Pump ASA 2 inch, OD 6 inch, Standard Cold Cap 120V, 450W.Agilent Varian Part Number 82906301 The Agilent Varian HS-2 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. This unit, smallest of the HS Series pumps, is well suited for laboratory and research use. The HS2 pump is a rugged, general-purpose unit with an operating range of 2 x 10-3 to <5 x 10-8 Torr. The Agilent Varian HS2 is ideal for applications requiring fast cycling because of its high pumping speed (285 l/s) air combined with high forepressure tolerance no load (0.55 Torr) and full load (0.40 Torr). Backstreaming rate of the unit is 1x10-3 mg/cm2/ min, without the use of any anti-cooled cold cap with only a slight reduction in pumping speed. Inlet Flange 2 inch ASA, 6 inch OD. This Agilent Varian HS-2 Diffusion Pump Includes: Inlet ASA 2" - 6" OD, Outlet .83" 13/16" tube Standard Cold Cap, 285 l/s pumping speed air 120 VAC @ 450 Watt (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 oil)). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian HS-2 can pump down to pressures of <5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 115 or 240 VAC heater harness. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian HS-2 diffusion pumps have ASA 2 inch - 6 inch O.D. and contain the 450 Watt heater. This pump is designed for use with Santovac 5 oil, has a pumping speed of 285 l/s air, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 120 VAC and has Agilent Varian part number 82006301. The Agilent Varian HS-2 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106746



Price: E£233,473.48


Regular Price: E£245,761.56




Currency: Egyptian Pound (EGP)

Agilent Varian HS-2 Water Cooled Diffusion Pump ASA 2 Standard Cold Cap 240V, 450W PN 82906302
In Stock
1


Agilent Varian HS-2 Water Cooled Vacuum Diffusion Pump ASA 2 inch, OD 6 inch, Standard Cold Cap 240V, 450W.Agilent Varian Part Number 82906302 The Agilent Varian HS-2 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. This unit, smallest of the HS Series pumps, is well suited for laboratory and research use. The HS2 pump is a rugged, general-purpose unit with an operating range of 2 x 10-3 to <5 x 10-8 Torr. The Agilent Varian HS2 is ideal for applications requiring fast cycling because of its high pumping speed (285 l/s) air combined with high forepressure tolerance no load (0.55 Torr) and full load (0.40 Torr). Backstreaming rate of the unit is 1x10-3 mg/cm2/ min, without the use of any anti-cooled cold cap with only a slight reduction in pumping speed. Inlet Flange 2 inch ASA, 6 inch OD. This Agilent Varian HS-2 Diffusion Pump Includes: Inlet ASA 2" - 6" OD, Outlet .83" 13/16" tube Standard Cold Cap, 285 l/s pumping speed air 240 VAC @ 450 Watt (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 oil)). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian HS-2 can pump down to pressures of <5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 115 or 240 VAC heater harness. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian HS-2 diffusion pumps have ASA 2 inch - 6 inch O.D. and contain the 450 Watt heater. This pump is designed for use with Santovac 5 oil, has a pumping speed of 285 l/s air, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 240 VAC and has Agilent Varian part number 82006302. The Agilent Varian HS-2 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.

Condition: New



Part Number: P106747



Price: E£242,065.52


Regular Price: E£254,805.37




Currency: Egyptian Pound (EGP)

Agilent Varian Jet Tube Assembly for HS-2 Diffusion Pump PN F0310301
Out of Stock


Agilent Varian HS-2 Diffusion Pump, Jet Tube Assembly Agilent Varian Part Number PN F0310301 This is a replacement jet tube assembly. Fits the Agilent Varian HS-2 Diffusion Pump. For location of the jet tube assembly see item #6 on (diagram exploded view & parts illustration) below.

Condition: New



Part Number: P107588



Price: E£86,097.92



Currency: Egyptian Pound (EGP)

Agilent Varian Heater Block for Diffusion Pump HS-2, PN 82920001
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Replacement Part Heater Block. Agilent Varian Part Number 82920001 This is a replacement part heater block (1 per diffusion pump). Fits the Agilent Varian HS-2 Diffusion Pump. See exploded view diagram item #3 for heater block location below.

Condition: New



Part Number: P106760



Price: E£5,987.94



Currency: Egyptian Pound (EGP)

Agilent Varian Hex Head Bolt, Attach ASA Gate Valves to ASA HS-2 Diffusion Pumps 3/8-16 1 inch length - 1 each
In Stock
44


Hex Bolt for attaching ASA Gate Valve to HS-2 Diffusion Pumps. (1each) This is a bolt that attaches and ASA Gate Valve to the HS-2 Varian Diffusion Pump. Size 3/8-16 1 Length, Course Thread, SS (1 each).

Condition: New



Part Number: P1011552



Price: E£33.54



Currency: Egyptian Pound (EGP)

Agilent Varian Heater Platen for Diffusion Pump HS-2, PN 82918301
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Replacement Part Heater Platen. Agilent Varian Part Number 82918301 This is a replacement part heater platen (1 per diffusion pump). Fits the Agilent Varian HS-2 Diffusion Pump. See exploded view diagram item #4 for heater platen location below.

Condition: New



Part Number: P106761



Price: E£19,881.39



Currency: Egyptian Pound (EGP)

Agilent Varian Refletor for HS-2 Diffusion Pump. PN 82917301
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Reflector Agilent Varian Part Number 82917301 This is replacement reflector. Fits the Agilent Varian HS-2 Diffusion Pump.

Condition: New



Part Number: P106763



Price: E£30,486.66



Currency: Egyptian Pound (EGP)

Agilent Varian Replacement (5) O-Ring Kit for Inlet Flange 2 in. ASA, Diffusion Pump HS-2, K0377159
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Replacement Part 5 Qty. O-Ring Set for ASA 2 in. Inlet Flange, butyl 2- 338. Agilent Varian Part Number PN K0377159 This is replacement parts O-Ring Kit for the 2 in. ASA Inlet Flange. (5 per package). Fits the Agilent Varian HS-2 Diffusion Pump. Made of butyl 2-338 rubber. Fits M-2 and HSA-150 pumps also.

Condition: New



Part Number: P106762



Price: E£10,577.66



Currency: Egyptian Pound (EGP)

Agilent Varian Cold Cap Assembly for HS-2 Diffusion Pump PN F0600301
Out of Stock


Agilent Varian HS-2 Diffusion Pump, Cold Cap Assembly Agilent Varian Part Number PN F0600301 This is a replacement cold cap assembly. Fits the Agilent Varian HS-2 Diffusion Pump. For location of the cold cap see item #8 on (diagram exploded view & parts illustration) below.

Condition: New



Part Number: P107584



Price: E£31,194.41



Currency: Egyptian Pound (EGP)

Agilent Varian Foreline Baffle for HS-2 Diffusion Pump PN 84166301
Out of Stock


Agilent Varian HS-2 Diffusion Pump, Foreline Baffle Agilent Varian Part Number PN 84166301 This is a replacement foreline exhuast baffle. Fits the Agilent Varian HS-2 Diffusion Pump. For location of the forenline exhaust baffle see item #9 on (diagram exploded view & parts illustration) below.

Condition: New



Part Number: P107585



Price: E£8,139.28



Currency: Egyptian Pound (EGP)

Agilent Varian Foreline Baffle Retaining Ring for HS-2 Diffusion Pump PN 660156010
Out of Stock


Agilent Varian HS-2 Diffusion Pump, Foreline Baffle Retaining Ring Agilent Varian Part Number PN 660156010 This is a replacement foreline baffle retaining ring. Fits the Agilent Varian HS-2 Diffusion Pump. For location of the foreline baffle retaining ring see item #10 on (diagram exploded view & parts illustration) below.

Condition: New



Part Number: P107587



Price: E£1,130.91



Currency: Egyptian Pound (EGP)

Agilent Varian 350 watt, 120V Heater Assembly for Diffusion Pump HS-2, for Santovac 5 Oil, 647301100
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Replacement Part Heater Assembly, 350W, 120VAC, for use with Santovac 5 oil. Agilent Varian Part Number 647301100 This is a replacement part heater assembly (also known as heater element). 350 Watt, 120 VAC for use with Santovac 5 oil. Fits the Agilent Varian HS-2 Diffusion Pump. See exploded view diagram item 1 & 2 for heater assembly location below. For directions on how to replace heater assembly scroll down to AVAILABLE DOWNLOADS and see page 1-3 in the HS-2 Service Manual PDF.

Condition: New



Part Number: P106756



Price: E£27,013.55



Currency: Egyptian Pound (EGP)

Agilent Varian 450 watt, 120V Heater Assembly for Diffusion Pump HS-2, for Santovac 5 Oil, 647302125
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Replacement Part Heater Assembly, 450W, 120 VAC, for use with Santovac 5 oil. Agilent Varian Part Number 647302125 This is a replacement part heater assembly (also known as heater element). 450 Watt, 120 VAC for use with Santovac 5 oil. Fits the Agilent Varian HS-2 Diffusion Pump. See exploded view diagram item 1 & 2 for heater assembly location below. For directions on how to replace heater assembly scroll down to AVAILABLE DOWNLOADS and see page 1-3 in the HS-2 Service Manual PDF.

Condition: New



Part Number: P106758



Price: E£22,722.22



Currency: Egyptian Pound (EGP)

Agilent Varian 350 watt, 240V Heater Assembly for Diffusion Pump HS-2, for Santovac 5 Oil, 647301125
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Replacement Part Heater Assembly, 350W, 240 VAC, for use with Santovac 5 oil. Agilent Varian Part Number 647301125 This is a replacement part heater assembly (also known as heater element). 350 Watt, 240 VAC for use with Santovac 5 oil. Fits the Agilent Varian HS-2 Diffusion Pump. See exploded view diagram item 1 & 2 for heater assembly location below. For directions on how to replace heater assembly scroll down to AVAILABLE DOWNLOADS and see page 1-3 in the HS-2 Service Manual PDF.

Condition: New



Part Number: P106757



Price: E£27,013.55



Currency: Egyptian Pound (EGP)

Agilent Varian 450 watt, 240V Heater Assembly for Diffusion Pump HS-2, for Santovac 5 Oil, 647302150
In Stock
1


Agilent Varian HS-2 Diffusion Pump, Replacement Part Heater Assembly, 450W, 240 VAC, for use with Santovac 5 oil. Agilent Varian Part Number 647302150 This is a replacement part heater assembly (also known as heater element). 450 Watt, 240 VAC for use with Santovac 5 oil. Fits the Agilent Varian HS-2 Diffusion Pump. See exploded view diagram item 1 & 2 for heater assembly location below. For directions on how to replace heater assembly scroll down to AVAILABLE DOWNLOADS and see page 1-3 in the HS-2 Service Manual PDF.

Condition: New



Part Number: P106759



Price: E£22,722.22



Currency: Egyptian Pound (EGP)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com