Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-fr
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Adixen 2021C2 Pumps On Sale Agilent IDP-15 Dry Scroll Vacuum Pumps On Sale Agilent Varian Helium Leak Detectors On Sale Pfeiffer ASM340 Leak Detectors On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Edwards nXR Multi Stage Roots Pumps On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3

Angle Molecular Sieve Trap, Inlet and Outlet NW25 KF25, Body size 4 in.

Condition:
  New
Part Number:
  P103863
Warranty:
  Against Product Defect

Available Now   2  

Sale: €1,567.83

Angle Molecular Sieve Trap, Inlet and Outlet NW25 KF25, Body size 4 in. 1567.83
Currency: Euro (Euro)

Description

Angle Molecular Sieve Trap, Inlet and Outlet NW25 KF25, Body size 4 inch OD


These molecular sieve traps perform a dual function. A Zeolite desiccant removes hydrocarbons which backstream toward the chamber when the mechanical pump oil is at it’s vapor pressure. Also, the Zeolite traps water vapor and other gasses before they reach the mechanical pump and contaminate the pump oil. Depending on the process, this can reduce the oil change frequency significantly. This Angle molecular sieve trap utilizes the two-piece trap design for ease of maintenance and Zeolite replacement. For maximum conductance the sieve material is contained in a suspended basket fabricated from perforated 304 stainless steel. This design provides conductance to the sieve at the top of the basket as well as around the periphery. A mid-basket baffle causes the gas to enter one-half of the basket and to exit the other half.

When initializing a trap, replacing the sieve or when base pressure cannot be achieved, the sieve should be regenerated by turning on the heater for a few hours and running the mechanical pump with it’s ballast valve open. The frequency and duration of sieve regeneration is dependent upon the kind and amount of gasses produced by the particular application. To replace the sieve, remove the trap end that contains the heater and remove the nut at the end of the basket. Dump the expired sieve material, replace with new, reattach the basket/end plate then perform the regeneration process outlined above.

A molecular sieve charge and regeneration heater are included with every trap. The heater is held in place with a clip that allows trap mounting in any position. Standard finish is beadblasted. Replacement molecular sieve trap Zeolite Charges are available on this website.

    Features:
  • Two piece clamped body design
  • Removable Zeolite media basket
  • Traps all condensable vapors
  • Stainless Steel type 304 construction, Viton O-Ring

  • Common Dimensions & Specs:
    A: 7.70"
    B: 6.55"
    C: 3.65"
    D: 4.00"

    Replacement Zeolite Charge Quantity: 0.75 lbs.
    Regeneration Heater Rating: 120V/125W
    Heater Port Outer Diameter: 1.00 inch
    Inlet & Outlet Flange Size: KF25



Brochure



Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.4258