Keyword Part Number:
Teledyne-Hastings DV-6M 1/8" Male NPT, Thermocouple Vacuum Gauge Tube, 0.001 to 1 Torr Range This Teledyne-Hastings DV-6M 1/8" NPT thermocouple (TC) vacuum gauge tube measures pressure between 0.001 and 1 Torr (1 to 1000 mTorr) and calibrated for clean, dry air or nitrogen. DV-6 series gauge tubes are used with TC gauge controllers such as the Ideal Vacuum digital XG-120 and Teledyne-Hastings VT and DCVT units (not included). These inexpensive sensors are used as ‘rough’ indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Teledyne-Hasting DV-6 tubes are matched and gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P102046
Price: €126.57
Teledyne-Hastings DV-6R 1/8" NPT Ruggedized Thermocouple Vacuum Gauge Tube, 0.001 to 1 Torr Range This Teledyne-Hastings DV-6M 1/8" NPT thermocouple (TC) vacuum gauge tube measures pressure between 0.001 and 1 Torr (1 to 1000 mTorr) and calibrated for clean, dry air or nitrogen. DV-6 series gauge tubes are used with TC gauge controllers such as the Ideal Vacuum digital XG-120 and Teledyne-Hastings VT and DCVT units (not included). These inexpensive sensors are used as ‘rough’ indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Teledyne-Hasting DV-6 tubes are matched and gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P102045
Price: €128.32
Teledyne-Hastings DV-6M-4-VCR Thermocouple Vacuum Gauge Tube, 4-VCR Fitting, 0.001 to 1 Torr Range This Teledyne-Hastings DV-6M thermocouple (TC) vacuum gauge tube with 4-VCR fitting, measures pressure between 0.001 and 1 Torr (1 to 1000 mTorr) and calibrated for clean, dry air or nitrogen. DV-6 series gauge tubes are used with TC gauge controllers such as the Ideal Vacuum digital XG-120 and Teledyne-Hastings VT and DCVT units (not included). These inexpensive sensors are used as ‘rough’ indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Teledyne-Hasting DV-6 tubes are matched and gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P102618
Price: €240.65
Teledyne-Hastings DV-6M-KF-16 Thermocouple Vacuum Gauge Tube, KF16 (NW16) Fitting, 0.001 to 1 Torr Range This Teledyne-Hastings DV-6M-KF-16 thermocouple (TC) vacuum gauge tube with KF16 fitting, measures pressure between 0.001 and 1 Torr (1 to 1000 mTorr) and calibrated for clean, dry air or nitrogen. DV-6 series gauge tubes are used with TC gauge controllers such as the Ideal Vacuum digital XG-120 and Teledyne-Hastings VT and DCVT units (not included). These inexpensive sensors are used as ‘rough’ indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Teledyne-Hasting DV-6 tubes are matched and gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P102616
Price: €334.39
Regular Price: €350.44
Teledyne-Hastings DV-6M-KF-25 Thermocouple Vacuum Gauge Tube, KF25 (NW25) Fitting, 0.001 to 1 Torr Range This Teledyne-Hastings DV-6M-KF-25 thermocouple (TC) vacuum gauge tube with KF25 fittin, measures pressure between 0.001 and 1 Torr (1 to 1000 mTorr) and calibrated for clean, dry air or nitrogen. DV-6 series gauge tubes are used with TC gauge controllers such as the Ideal Vacuum digital XG-120 and Teledyne-Hastings VT and DCVT units (not included). These inexpensive sensors are used as ‘rough’ indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Teledyne-Hasting DV-6 tubes are matched and gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P102617
Price: €324.76
Teledyne-Hastings DV-36 Thermocouple Vacuum Gauge Tube, 0 to 1000 mTorr Range, High Temperatures and High Pressures, DV 6 series, 1/8 in. (0.125") NPT, Stainless Steel. PN: DV-36 This Teledyne-Hastings DV-36 DV 6 series Thermocouple (TC) vacuum gauge tube measures pressure between 0.001 and 1 Torr (1 to 1000 mTorr) and calibrated for clean, dry air or nitrogen. DV-6 series gauge tubes are used with TC gauge controllers such as the Ideal Vacuum digital XG-120 and Teledyne-Hastings VT and DCVT units (not included). These inexpensive sensors are used as "rough" indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Teledyne-Hasting DV-6 tubes are matched and gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P1011939
Price: €490.29
Teledyne Hastings OM-25-OFV Extension Cable for Vacuum Gauges, 25 ft., PN- OM-25-OFV. Teledyne Hastings Part Number: OM-25-OFV. Teledyne Hastings OM-25-OFV 25 ft. long extension cable for connecting controllers to vacuum gauges.
Condition: New
Part Number: P1010903
Price: €152.93
Teledyne-Hastings DV-6R-CF Ruggedized Thermocouple Vacuum Gauge Tube, Conflat 1.33 Inch Fitting, 0.001 to 1 Torr Range This Teledyne-Hastings DV-6M 1/8 NPT thermocouple (TC) vacuum gauge tube measures pressure between 0.001 and 1 Torr (1 to 1000 mTorr) and calibrated for clean, dry air or nitrogen. DV-6 series gauge tubes are used with TC gauge controllers such as the Ideal Vacuum digital XG-120 and Teledyne-Hastings VT and DCVT units (not included). These inexpensive sensors are used as ‘rough’ indicators to monitor mechanical pump vacuum levels and to signal when crossover (to high-vacuum) pressure has been reached. Teledyne-Hasting DV-6 tubes are matched and gauge controller recalibration is not required when gauge tubes are replaced. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P104376
Price: €454.30
Teledyne Hastings DV-6S Ruggedized Thermocouple Vacuum Gauge Tube, 1/8 in. NPT, with Protective Cap for 0.001 to 1 Torr Range. PN: DV-6S Teledyne Hastings DV-6S ruggedized thermocouple vacuum gauge tubes have a rugged steel housing and can measure pressure between 0.001 and 1 Torr (1 to 1000 mTorr). Teledyne Hastings DV-6S vacuum sensors are calibrated for nitrogen or air, but conversion factors for other gases are available. The Teledyne Hasting DV-6S tubes are matched and interchangeable without calibration adjustments. The DV-6S thermocouple tubes are for use with Teledyne Hastings Digital or Analog VT-6 thermocouple gauge controllers. These DV-6S tubes have a standard 1/8 inch male NPT vacuum fitting are brand new with full Teledyne Hastings warranty. Part Number DV-6S. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. A common variant is the Pirani gauge which uses a single platinum filament as both the heated element and RTD. These gauges are accurate from 10 Torr to 10-3 Torr, but they are sensitive to the chemical composition of the gases being measured (from Wikipedia.org). The Teledyne Hastings Instruments DV-6S thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. Teledyne Hastings DV-6S thermocouple pressure measurement gauges are used in glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and others. Hastings DV-6 tubes are also available: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P105174
Price: €338.55
Teledyne Hastings DB-20 Reference Tube, Equivalent Gauge Tube DV-6M, Range 0-1000 mTorr. PN: DB-20, NIST-DV-6M The Teledyne Hastings Instruments (THI) DB-20 Reference Tube is an evacuated, sealed vacuum gauge tube accurately calibrated to precisely simulate a gauge tube at a given operating pressure. This Teledyne Hastings Instruments DB-20 Reference Tube it is electrically equivalent to the Gauge Tube DV-6M series Range 0-1000 mTorr, used with THI instruments. The DB-20 Reference Tube permits quick and easy recalibration of THI Vacuum Gauge Indicators by merely plugging the instrument into the reference and adjusting the calibration “current set” potentiometer until the instrument reads the exact pressure noted on the reference. THI Reference Tubes are available equivalent to most THI Gauge Tubes. Part Number DB-20. The applications for The Teledyne Hastings Instruments (THI) DB-20 Reference Tube: THI Vacuum Gauge Indicators or Controllers can be checked or recalibrated in seconds by merely plugging the gauge tube cable into the reference tube. If calibration adjustment is necessary, the “Current Set” potentiometer is adjusted until the instrument indicates the pressure marked on the reference tube. The customer now knows his instrument is correctly calibrated. Whenever cable lengths between gauge tube and instrument are changed, some error may be introduced, requiring that the instrument be readjusted to compensate for any losses involved. By plugging the Reference Tube into the new cable and readjusting the instrument for a correct reading, this “error” is eliminated. Choose the reference tube that is equivalent to the glass or metal THI Gauge Tube you are now using. The Reference Tube will be matched and sealed at a pressure falling on the lower portion of the scale and calibrated accurately at this exact pressure. For example, if an instrument uses a DV-6M Gauge Tube, a DB-20 Reference Tube is ordered. If a customer receives a reference tube marked “at 10 mTorr”, this is the pressure to which the indicator should be adjusted when plugged into the reference tube. THI Reference Tubes employ the same THI noble metal thermopile used in all THI Thermopile Vacuum Gauge Tubes. The thermopile is sealed in a glass capsule that has been evacuated, baked, outgassed, sealed, and then aged to ensure stability over long periods of time. The sealed capsule is then housed in a protective metal shell to provide a rugged, trouble-free assembly. Considerable care and time are required in the manufacture to obtain the high degree of precision and stability required for the reference tube. The THI Reference Tube maintains its calibration over long periods of time. However, for applications requiring the highest possible degree of accuracy, a periodic return of the reference tube to the factory for a check and recalibration may be desirable. An annual or semiannual check assures the customer of an accurate and reliable reference at all times.
Condition: New
Part Number: P105330
Price: €761.69
Teledyne Hastings Digital VT Thermocouple Vacuum Gauge Controller for DV-6 Gauge Tubes (Stock Number 55-288DB6) These Teledyne Hastings Digital VT thermocouple vacuum gauge controllers are matched for the DV-6 thermocouple vacuum gauge tubes (Stock Number 55-288DV6, Operates on 115 VAC). They measure pressure between the range of 0.001 and 1 Torr (1 to 1000 mTorr). The Teledyne Hastings Digital VT thermocouple controllers are self-contained instruments that offer extreme versatility for most vacuum applications. The electronic design assures long life and minimal maintenance. Compact Digital VT Models are ready for mounting onto a panel. Teledyne Hasting thermocouple tubes are also available but sold separately.
Condition: New
Part Number: P102051
Price: €704.69
Teledyne Hastings Digital DCVT Thermocouple Vacuum Gauge Controller for DV-4, DV-5 and DV-6 Gauge Tubes. Teledyne Part Number: DCVT-4-01-04. The Teledyne Hastings Instrument’s Digital DCVT, is a digital readout version of the successful CVT Series. These pressure gauges offer exceptional stability, accuracy, and reliability. This instrument has been designed for laboratory or light industrial applications. It is not suitable for outdoor or heavy industrial areas where spraying liquid or wash-downs may occur. A precision A/D converter, with a microprocessor is used to measure the gauge tube’s signal output; it converts the measurement to a pressure reading using the gauge tube’s well defined output/pressure function, and then displays the result. A 0 – 1 volt amplified non-linear gauge tube output version along with 0-1volt, 0-5volt, 0-10volt, 0-20mA, and 4-20mA linear gauge tube output versions are available on the back panel. This unit accepts 90-250 VAC for input power. The current pressure reading can also be acquired digitally through the standard RS232 port. The dual control points are durable 10 amp single pole double throw relays which can be configured normally open or normally closed. The Digital CVT Vacuum can read the Teledyne Hastings DV-4, DV-5, and DV-6 gauge tubes. The DV-4 range is 0.2-20 Torr. The DV-5 range is 0.1 – 100 m Torr. The DV-6 range is 1-999 mTorr. All VT-Series Vacuum Gauges feature long life and minimal maintenance. These instruments utilize Teledyne Hastings rugged noble metal thermocouple gauge tubes that are designed specifically for each range. Tubes are matched and interchangeable without calibration adjustments. They are compensated for temperature, rate of temperature change and are corrosion resistant. Comes with power cord and terminal cord for the tubes. Scroll down to download a complete DCVT instruction manual.pdf
Condition: New
Part Number: P107682
Price: €1,243.24
Teledyne Hastings Analog VT Thermocouple Vacuum Gauge Controller for DV-6 Tubes, 0-1 Torr, Panel Mount, Analog Output. Teledyne-Hastings Part Number: PN: VT-6A. This Teledyne-Hastings model VT-6A (formerly VT-6-X-Y) panel mount gauge controller for DV-6 thermocouple vacuum tube gauges measures between 0 and 1000 mTorr, and operates on 115/230 VAC. A removeable round rear cover provides access to the AC power, gauge tube, and output terminals (0-1 VDC analog, non-linear). Includes gauge cable. Please see the Gauge Controller manual in the downloads for specs and information. Thermocouple tubes and AC power cable sold separately.
Condition: New
Part Number: P102055
Price: €739.41
Teledyne Hastings Digital DCVT-6 Thermocouple Vacuum Gauge Controller for DV-6 Tubes, Digital Output (DCVT) Ranges 1 - 999 mTorr Dual Setpoint Control Relays. Teledyne Part Number: DCVT-6-B-01 (Replaces the Analog VT Thermocouple Vacuum Gauge Controller CVT-6). These Teledyne Hastings Digital DCVT-6 Controllers are used with DV-6 Tubes, Digital Output (DCVT) Ranges 1 - 999 mTorr Dual Setpoint Control Relays. The digital DCVT-6 Vacuum Measurement is the new generation series and replaces the obsolete Analog CVT thermocouple vacuum gauge controllers are matched for the DV-6 thermocouple vacuum gauge tubes (Stock Number VT-26-X-Y). They measure pressure between the range of 0.001 and 1 Torr. The Teledyne Hastings Analog CVT thermocouple controllers are self-contained instruments that offer extreme versatility for most vacuum applications. The electronic design assures long life and minimal maintenance. These controllers digital DCVT Models are ready for mounting onto a panel. Teledyne Hasting thermocouple tubes are also available but sold separately.
Condition: New
Part Number: P1010695
Price: €1,363.65
Teledyne Hastings Analog VT Thermocouple Vacuum Gauge Controller for DV-6 Tubes, 0-1 Torr, Enclosed Cabinet, Analog Output. Teledyne-Hastings Part Number: VT-6AB. This Teledyne-Hastings model VT-6AB (VT-6B-X-Y) enclosed cabinet gauge controller for DV-6 thermocouple vacuum tube gauges controllers measures between 0 and 1000 mTorr, and operates on 115 VAC. This model has connected power and gauge tube cables. It also features BNC connectors on the back for output (0-1 VDC analog, non-linear). Please see the Gauge Controller manual in the downloads for specs and information. Thermocouple tubes are sold separately.
Condition: New
Part Number: P102056
Price: €1,138.02
Teledyne Hastings Analog VT Thermocouple Vacuum Gauge Controller for DV-6 Tubes, 0-1 Torr, Enclosed Cabinet, 5 Channels, Analog Output. Teledyne-Hastings Part Number: VT-6S5-X-Y This Teledyne-Hastings model VT-6S5-X-Y enclosed cabinet gauge controller for VT6 thermocouple vacuum tube gauges controllers measures between 0 and 1000 mTorr, and operates on 115 VAC (connected power cable). This model can be connected to 5 gauge tubes and has a 5 position switch on the face for selection. This controller also has BNC connectors on the back for output (0-1 VDC analog, non-linear). Please see the Gauge Controller manual in the downloads for specs and information. Thermocouple tubes and gauge tube cables are sold separately.
Condition: New
Part Number: P1010698
Price: €1,533.72
Thermocouple Vacuum Gauge Controller CVT26A-0-0 with 2 Set Points & Relays for Process Control, 0-1000 mTorr, 1-Phase 115 VAC, Panel Mount, For DV-6 Sensor Thermocouple Tubes. (PN CVT26A-0-0) These Teledyne Hastings Analog CVT26A (panel mount) thermocouple vacuum gauge controllers are matched for the DV-6 thermocouple vacuum gauge tubes and operate on 115VAC. They measure pressure between the range of 0-1000 mTorr . The Teledyne Hastings Analog CVT26A thermocouple controllers are self-contained instruments that offer extreme versatility for most vacuum applications. The electronic design assures long life and minimal maintenance. They are fully automatic, continuous-reading instruments for unlimited vacuum applications. These controllers have 2 set points that are durable and have 5 amp single pole double throw relays which can be configured normally open or normally closed. These instruments utilize Teledyne's rugged but sensitive noble metal TC gauge sensor tubes that are designed specifically for each range. Tubes are matched and interchangeable without calibration adjustments. They are compensated for temperature and rate of temperature change and are corrosion-resistant. These VacuuGaugege Controllers are compatible with all the Teledyne DV-6 Sensor Thermocouple Tubes, Sold on this website, See RELATED ARTICLES below: Users Manuals and Spec Sheets .pdf's available for download below at AVAILABLE DOWNLOADS:
Condition: New
Part Number: P104917
Price: €1,362.60
Teledyne Hastings Cable for Digital AVC for DV-4, DV-5, DV-6 Thermocouple Gauges, 1.5 Meter Long PN: CB-DAVC-1.5M This is a 1.5 meter long cable for connecting the Teledyne-Hastings DAVC module to a thermocouple controller, such as the Teledyne-Hastings Digital VT. One end of the cable is terminated in a HD-15 connector which connects to the DAVC module. The other cable end is unterminated and color coded. The Teledyne-Hastings DAVC is attached to a DV-4, DV-5, or DV-6 thermocoule gauge and converts the output voltage signal into a digital signal. The signal can be obtained by an appropriate controller, or over RS-232 for remote operation.
Condition: New
Part Number: P1011701
Price: €139.47
Teledyne-Hastings Digital Vacuum Controller (Digital AVC) for DV series Gauge Tubes, Torr with linear analog output 0-10 VDC. Teledyne-Hastings Part Number: DVAC-6-01-04 The Teledyne Hastings Instruments’ DAVC (Digital AVC) is a microprocessorbased vacuum gauge. In addition to the linear analog outputs (0-1 VDC, 0-5 VDC, 0-10 VDC, 4-20 mA, or 0-20 mA), pressure measurements can be accessed via the RS232 digital output. Digital readings can be provided in either Torr, mbar, or Pascal units. A precision A/D converter, along with the microprocessor, measures the thermocouple vacuum gauge tube’s output and converts the measurement to a pressure reading employing the gauge tube’s well-defined output/ pressure function. The DAVC is a continuous-reading instrument for vacuum measurement and process control applications. The instrument is packaged in a small aluminum case with controls and electrical “D” connector located on the top. For Complete instructions on how to use this Digital AVC Controller see .pdf''s to the left at Downloads. Teledyne-Hastings DV-6 gauge tubes use a rugged, but sensitive noble metal thermocouple and corrosion resistant stainless steel and nickel plated components. They are temperature and temperature change-rate compensated, making them well suited for ambient installations. Standard DV-6 gauge tubes are rated for a maximum temperature of 100° C. Ruggedized gauge tubes are rated for 150° C. Thermocouple sensors (thermal conductivity gauges) rely on the fact that the ability of a gas to conduct heat decreases with pressure. In this type of gauge, a wire filament is heated by running current through it. A thermocouple or Resistance Temperature Detector (RTD) can then be used to measure the temperature of the filament. This temperature is dependent on the rate at which the filament loses heat to the surrounding gas, and therefore on the thermal conductivity. The Teledyne Hastings Instruments DV-6 thermocouple gauges have a reputation built upon exceptional stability, accuracy, and reliability under the most demanding conditions. DV-6 thermocouple gauge tube sensors are used in a wide variety of applications such as glove boxes, cryogenics, vacuum furnaces, pharmaceutical production, freeze drying, agricultural processes, air conditioning, thermal food containers, plasma coating, refrigeration (HVAC), accelerators, appliance manufacturing and many others. DV-6 series gauge tubes are available with several vacuum port configurations: DV-6M, Standard Tube with 1/8 inch Male NPT DV-6R, Ruggedized Tube with 1/8 inch NPT DV-6M-KF-16, Standard Tube with ISO KF-16 DV-6M-KF-25, Standard Tube with ISO KF-25 DV-6M-4-VCR, Standard Tube with Female ¼ inch VCR DV-6R-CF, Ruggedized Tube with 1-1/3 inch Mini Conflat
Condition: New
Part Number: P1011803
Price: €596.06
Teledyne Hastings HPM-4/6 Octal Socket for All Thermocouple Vacuum Gauge Tubes, DV-4, DV-5, DV-6, DV-23 PN: 28-07-049This is a replacement octal socket for all Teledyne-Hastings thermocouple vacuum gauge tubes including all DV-4, DV-5, DV-6 and DV-23 gauges. Use to replace a broken part, or to make your own gauge cable. We stock most Teledyne Hastings thermoucouple gauge tubes and gauge controllers.
Condition: New
Part Number: P1011448
Price: €31.49
Teledyne Hastings Replacement AC power cord with Lugs for Analog Enclosed Gauge Controllers PN: 65-757 This is a replacement AC power cord for all enclosed analog Teledyne-Hastings thermocouple vacuum gauge controllers. We stock most Teledyne Hastings thermoucouple gauge tubes, reference tubes, and gauge controllers.
Condition: New
Part Number: P1011542
Price: €67.15
Teledyne Hastings Octal Socket Cable 8ft. for All Thermocouple Vacuum Gauge Tubes, DV-4, DV-5, DV-6, DV-23 PN: LUG-8-OFVThis is a replacement octal socket cable 8 ft. for all Teledyne-Hastings thermocouple vacuum gauge tubes including all DV-4, DV-5, DV-6 and DV-23 gauges. We stock most Teledyne Hastings thermoucouple gauge tubes and gauge controllers.
Condition: New
Part Number: P1011903
Price: €122.04