Keyword Part Number:
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 200 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle), Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9670304 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670304 Inlet KF50, Outlet KF16 Standard Cold Cap (No Baffle) 220 VAC @ 200 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 200 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9670304. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106737
Price: £1,743.16
Regular Price: £1,834.91
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9670302 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670302 Inlet KF50, Outlet KF16 Standard Cold Cap (No Baffle) 220 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9670302. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106729
Price: £1,679.09
Regular Price: £1,767.46
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle), Operates On 1-Phase 90 VAC, Agilent Varian Part Number L9670305 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670304 Inlet KF50, Outlet KF16 Standard Cold Cap (No Baffle) 90 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 90 VAC and has Agilent Varian part number L9670305. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106738
Price: £1,743.16
Regular Price: £1,834.91
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9670312 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670312 Inlet KF50, Outlet KF16 Internal Baffle (prevents backstreaming) 220 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9670312. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106732
Price: £1,858.74
Regular Price: £1,956.57
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 200 Watt Heater with Baffle, Designed For IVP 704 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9670314 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670314 Inlet KF50, Outlet KF16 Internal Baffle (prevents backstreaming) 220 VAC @ 200 Watt Heater (Designed To Be Used With IVP 704 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 200 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with IVP 704 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9670314. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106734
Price: £1,858.74
Regular Price: £1,956.57
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping Speed Air Cooled, Operates On 1-Phase 90 VAC, Agilent Varian Part Number L9670315 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670315 Inlet KF50, Outlet KF16 Internal Baffle (prevents backstreaming) 90 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 90 VAC and has Agilent Varian part number L9670315. The Agilent Varian AX 65 diffusion pump user's instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106735
Price: £1,858.74
Regular Price: £1,956.57
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9707302 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707302 Inlet ISO-63K, Outlet KF16 Standard Cold Cap (No Baffle) 220 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9707302. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106724
Price: £1,900.44
Regular Price: £2,000.46
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 200 Watt Heater Designed For IVP 704 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9707304 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707304 Inlet ISO-63K, Outlet KF16 Standard Cold Cap (No Baffle) 220 VAC @ 200 Watt Heater (Designed To Be Used With IVP 704 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 200 Watt heater which is designed for use with IVP 704 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9707304. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106726
Price: £1,900.44
Regular Price: £2,000.46
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 90 VAC, Agilent Varian Part Number L9707305 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707305 Inlet ISO-63K, Outlet KF16 Standard Cold Cap (No Baffle) 90 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 90 VAC and has Agilent Varian part number L9707305. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106727
Price: £1,900.44
Regular Price: £2,000.46
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9707312 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707312 Inlet ISO-63K, Outlet KF16 Internal Baffle (prevents backstreaming) 220 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9707312. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106720
Price: £1,988.22
Regular Price: £2,092.86
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 200 Watt Heater with Baffle, Designed For IVP 704 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9707314 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707314 Inlet ISO-63K, Outlet KF16 Internal Baffle (prevents backstreaming) 220 VAC @ 200 Watt Heater (Designed To Be Used With IVP 704 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 200 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with IVP 704 Oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 220 VAC and has Agilent Varian part number L9707314. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106721
Price: £1,988.22
Regular Price: £2,092.86
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 90 VAC, Agilent Varian Part Number L9707315 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707315 Inlet ISO-63K, Outlet KF16 Internal Baffle (prevents backstreaming) 90VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 90 VAC and has Agilent Varian part number L9707315. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106722
Price: £1,988.22
Regular Price: £2,092.86
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 115 VAC, Agilent Varian Part Number L9670301 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670301 Inlet KF50, Outlet KF16 Standard Cold Cap (No Baffle) 115 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9670301. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106730
Price: £1,743.16
Regular Price: £1,834.91
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 200 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 115 VAC, Agilent Varian Part Number L9670303 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670303 Inlet KF50, Outlet KF16 Standard Cold Cap (No Baffle) 115 VAC @ 200 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 200 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9670303. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106751
Price: £1,834.91
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle), Operates On 1-Phase 165 VAC, Agilent Varian Part Number L9670306 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670306 Inlet KF50, Outlet KF16 Standard Cold Cap (No Baffle) 165 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 165 VAC and has Agilent Varian part number L9670306. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106739
Price: £1,743.16
Regular Price: £1,834.91
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 115 VAC, Agilent Varian Part Number L9670311 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670311 Inlet KF50, Outlet KF16 Internal Baffle (prevents backstreaming) 115 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9670311. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106731
Price: £1,858.74
Regular Price: £2,002.00
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 200 Watt Heater with Baffle, Designed For IVP 704 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 220 VAC, Agilent Varian Part Number L9670312 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670312 Inlet KF50, Outlet KF16 Internal Baffle (prevents backstreaming) 115 VAC @ 200 Watt Heater (Designed To Be Used With IVP 704 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 200 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with IVP 704 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9670313. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106733
Price: £1,858.74
Regular Price: £1,956.57
Agilent Varian AX-65 Diffusion Pump, KF50 Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 165 VAC, Agilent Varian Part Number L9670316 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9670316 Inlet KF50, Outlet KF16 Internal Baffle (prevents backstreaming) 165 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have KF50 inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 165 VAC and has Agilent Varian part number L9670316. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106736
Price: £1,858.74
Regular Price: £1,956.57
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 115 VAC, Agilent Varian Part Number L9707301 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707301 Inlet ISO-63K, Outlet KF16 Standard Cold Cap (No Baffle) 115 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9707301. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106573
Price: £1,844.84
Regular Price: £2,000.46
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 165 VAC, Agilent Varian Part Number L9707306 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707306 Inlet ISO-63K, Outlet KF16 Standard Cold Cap (No Baffle) 165 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater which is designed for use with Santovac 5 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 165 VAC and has Agilent Varian part number L9707306. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106728
Price: £1,900.44
Regular Price: £2,000.46
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 200 Watt Heater Designed For IVP 704 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Standard Cold Cap (No Baffle) Operates On 1-Phase 115 VAC, Agilent Varian Part Number L9707303 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707303 Inlet ISO-63K, Outlet KF16 Standard Cold Cap (No Baffle) 115 VAC @ 200 Watt Heater (Designed To Be Used With IVP 704 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 200 Watt heater which is designed for use with IVP 704 oil, have a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9707303. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106725
Price: £1,900.44
Regular Price: £2,000.46
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 115 VAC, Agilent Varian Part Number L9707311 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707311 Inlet ISO-63K, Outlet KF16 Internal Baffle (prevents backstreaming) 115 VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9707311. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106719
Price: £1,988.22
Regular Price: £2,092.86
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 200 Watt Heater with Baffle, Designed For IVP 704 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 115 VAC, Agilent Varian Part Number L9707313 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707313 Inlet ISO-63K, Outlet KF16 Internal Baffle (prevents backstreaming) 115 VAC @ 200 Watt Heater (Designed To Be Used With IVP 704 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 200 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with IVP 704 Oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 115 VAC and has Agilent Varian part number L9707313. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106745
Price: £1,988.22
Regular Price: £2,092.86
Agilent Varian AX-65 Diffusion Pump, ISO-63K Inlet, 250 Watt Heater with Baffle, Designed For Santovac 5 Oil, 65 l/s of Air Pumping SpeedAir Cooled, Operates On 1-Phase 90 VAC, Agilent Varian Part Number L9707316 These Agilent Varian model AX-65 high vacuum diffusion pumps are air cooled and the primary industrial standard for compact high vacuum pumping. The Agilent Varian AX-65 diffusion pumps have a high pumping speed for all gases and the lowest cost per unit pumping speed when compared with other types of pumps used in the same vacuum range. The AX-65 pumps feature glass fill and drain assemblies for easy maintenance of diffusion pump fluid and continuous monitoring. These AX-65 models include a finned boiler which increases the surface area and prolongs fluid life. The full fractionating design allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purest vapor reaches the top jet, assuring highest speed and lowest backstreaming. This Agilent Varian AX-65 Diffusion Pump Includes: Air Cooled Diffusion Pump With Fan, PN L9707316 Inlet ISO-63K, Outlet KF16 Internal Baffle (prevents backstreaming) 165VAC @ 250 Watt Heater (Designed To Be Used With Santovac 5 Oil) Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure (Santovac 5 or IVP 704 depending on the heater harness). Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian AX-65 can pump down to pressures of 5x10-8 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction, toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, the Agilent Varian AX-65 can be OPTIONALLY equipped with a baffle to deflect oil particles before they can reach the process stream. These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 90, 115, 165, or 220 VAC heater harness. We stock and sell Santovac 5 and IVP 704 diffusion pump fluids for this pump (depending on heater harness). Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website. These Agilent Varian AX-65 diffusion pumps have ISO-63K inlet vacuum flange, contain the 250 Watt heater and have an internal baffle installed to restrict backstreaming. This pump is designed for use with Santovac 5 oil, has a pumping speed of 65 l/s, are air cooled, being compact for easy incorporation into small laboratory instruments, operates on 1-phase 165 VAC and has Agilent Varian part number L9707316. The Agilent Varian AX 65 diffusion pump user’s instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.
Condition: New
Part Number: P106723
Price: £1,988.22
Regular Price: £2,092.86
Agilent Varian Fan Universal Voltage 115-230 VAC for AX-65 Diffusion Pump Agilent Varian Part Number 661300138 This is the fan universal voltage 115-230 VAC for the AX-65 Diffusion Pump. This is the fan only pump not included. For location of fan see item #8 on (diagram exploded view & parts illustration) below.
Condition: New
Part Number: P107583
Price: £198.05
Agilent Varian Optional Pump Ready 170ºF Thermal Switch for AX-65 Diffusion Pump. Agilent Varian Part Number L9964002 This is a (Optional) Pump Ready thermal switch. This thermal Pump Ready switch, is to be attached to the side plate of the AX-65 Pump next to the over temperature thermal switch. This optional thermal switch can be connected to a light to show when the pump is at operating temperature. It is normally open and closes when the pump reaches operating temperature. The switch is set to close at 170ºF (operating temperature). See graphic for installation/location on the pump.
Condition: New
Part Number: P106754
Price: £142.18
Agilent Varian Replacement Over Temperature 365ºF Thermal Switch for AX-65 Diffusion Pump Heater Harnesses Agilent Varian Part Number L9964001 This is a 365ºF replacement thermal switch for the following AX-65 diffusion pump heater harnesses: 200W, 115 VAC heater harness, PN L9994307 250W, 115 VAC heater harness, PN L9994303 200W, 220 VAC heater harness, PN L9994308 250W, 220 VAC heater harness, PN L9994304 250W, 165 VAC heater harness, PN L9994302 250W, 90 VAC heater harness, PN L9994301 This is a replacement over temperature thermal switch. A normally-closed, over temperature thermal switch has been attached to the diffusion pump body via the heater harness on the side of the pump. Loss of cooling, high temperatures, high pressure, or low fluid level causes the contacts of the thermal switch to open. When the problem has been corrected, the thermal switch automatically resets to closed. The switch is set to open at 365ºF. See #6 on (diagram exploded view & parts) illustration below for location.
Condition: New
Part Number: P106753
Price: £200.59
Agilent Varian Inlet Baffle Retorfit KF50 for AX-65 Diffusion Pump. Agilent Varian Part Number R1160065 This is a retrofit inlet baffle for the inlet KF50 of the AX-65 Vacuum Diffusion Pump. For location see item #3 on (diagram exploded view & parts illustration) below.
Condition: New
Part Number: P107009
Price: £253.65
Agilent Varian Cold Cap for AX-65 Diffusion PumpAgilent Varian Part Number L9675301 This is the cold cap for the AX-65 Diffusion Pump. For location of cold cap see item #2 on (diagram exploded view & parts illustration) below.
Condition: New
Part Number: P107580
Price: £104.26
Agilent Varian Inlet Baffle for AX-65 Diffusion Pump Agilent Varian Part Number L9706001 This is the inlet baffle for the AX-65 Diffusion Pump. For location of inlet baffle see item #3 on (diagram exploded view & parts illustration) below.
Condition: New
Part Number: P107581
Price: £238.47
Agilent Varian Foreline Exhuast Baffle for AX-65 Diffusion Pump Agilent Varian Part Number L9676301 This is the foreline exhaust baffle for the AX-65 Diffusion Pump. For location of foreline exhaust baffle see item #9 on (diagram exploded view & parts illustration) below.
Condition: New
Part Number: P107582
Price: £42.39
Agilent Varian jet assembly with top hat and shield for AX-65 Diffusion Pump Agilent Varian Part Number L9674301 This is the jet assembly with top hat and shield for the AX-65 Diffusion Pump. For location see item #1 on (diagram exploded view & parts illustration) below.
Condition: New
Part Number: P107586
Price: £286.95
Agilent Varian Bottom Insulation for AX-65 Diffusion Pump. Agilent Varian Part Number L9701002 This is the bottom insulation for the AX-65 Diffusion Pump, 1 required with heater harness. For location of cold cap see item #12 on (diagram exploded view & parts illustration) below.
Condition: New
Part Number: P106755
Price: £17.66
Agilent Varian AX-65 Diffusion Pump, Replacement Part Heater Harness, 250W, 90 VAC, with thermal switch, for use with Santovac 5 oil Agilent Varian Part Number L9994301 This is a replacement part heater harness (also known as heater element) with thermal switch attached. 250 Watt, 90 VAC, for use with Santovac 5 oil. Fits the Agilent Varian AX-65 Diffusion Pump. See exploded view diagram label 5 for heater harness location below. For directions on how to replace heater harness (heater element) scroll down to AVAILABLE DOWNLOADS and see pages A-3, A-4 in the AX-65 Service Manual PDF.
Condition: New
Part Number: P106743
Price: £510.11
Agilent Varian AX-65 Diffusion Pump, Replacement Part Heater Harness, 200W, 115VAC, with thermal switch, for use with IVP 704 oil, Agilent Varian Part Number L9994307 , This is a replacement part heater harness (also known as heater element) with thermal switch attached. 200 Watt, 115 VAC for use with IVP 704 oil. . Fits the Agilent Varian AX-65 Diffusion Pump. See exploded view diagram label 5 for heater harness location below. For directions on how to replace heater harness (heater element) scroll down to AVAILABLE DOWNLOADS and see pages A-3, A-4 in the AX-65 Service Manual PDF.
Condition: New
Part Number: P106742
Price: £510.11
Agilent Varian AX-65 Diffusion Pump, Replacement Part Heater Harness, 250W, 115VAC, with thermal switch, for use with Santovac 5 oil Agilent Varian Part Number L9994303 This is a replacement part heater harness (also known as heater element) with thermal switch attached. 250 Watt, 115 VAC, for use with Santovac 5 oil. Fits the Agilent Varian AX-65 Diffusion Pump. See exploded view diagram label 5 for heater harness location below. For directions on how to replace heater harness (heater element) scroll down to AVAILABLE DOWNLOADS and see pages A-3, A-4 in the AX-65 Service Manual PDF.
Condition: New
Part Number: P106741
Price: £510.11
Agilent Varian AX-65 Diffusion Pump, Replacement Part Heater Harness, with thermal switch, 250W, 165 VAC, for use with Santovac 5 oil Agilent Varian Part Number L9994302 This is a replacement part heater harness (also known as heater element) with thermal switch attached. 250 Watt, 165 VAC, for use with Santovac 5 oil. Fits the Agilent Varian AX-65 Diffusion Pump. See exploded view diagram label 5 for heater harness location below. For directions on how to replace heater harness (heater element) scroll down to AVAILABLE DOWNLOADS and see pages A-3, A-4 in the AX-65 Service Manual PDF.
Condition: New
Part Number: P106752
Price: £510.11
Agilent Varian AX-65 Diffusion Pump, Replacement Part Heater Harness, with thermal switch, 250W, 220 VAC, for use with Santovac 5 oil Agilent Varian Part Number L9994304 This is a replacement part heater harness (also known as heater element) with thermal switch attached. 250 Watt, 220 VAC, for use with Santovac 5 oil. Fits the Agilent Varian AX-65 Diffusion Pump. See exploded view diagram label 5 for heater harness location below. For directions on how to replace heater harness (heater element) scroll down to AVAILABLE DOWNLOADS and see pages A-3, A-4 in the AX-65 Service Manual PDF.
Condition: New
Part Number: P106744
Price: £510.11
Agilent Varian AX-65 Diffusion Pump, Replacement Part Heater Harness, 200W, 220VAC, with thermal switch, for use with IVP 704 oil, Agilent Varian Part Number L9994308 , This is a replacement part heater harness (also known as heater element) with thermal switch attached. 200 Watt, 220 VAC for use with IVP 704 oil. Fits the Agilent Varian AX-65 Diffusion Pump. See exploded view diagram label 5 for heater harness location below. For directions on how to replace heater harness (heater element) scroll down to AVAILABLE DOWNLOADS and see pages A-3, A-4 in the AX-65 Service Manual PDF.
Condition: New
Part Number: P106740
Price: £510.11
Replacement Thermocouple for Measuring Temperature of Agilent Varian AX-65 Diffusion Vacuum Pumps. Comparable to Thermocouple Agilent Varian part number 642906115 (Now discontinued by Agilent). Replacement Thermocouple for measuring temperature of Agilent Varian AX-65 diffusion vacuum pumps, comparable to Thermocouple Agilent Varian part number 642906115. One end is connected to the diffusion pump the other end is connected to a temperature gauge.
Condition: New
Part Number: P109634
Price: £76.02