Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-gb
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nEXT300D TStations On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Adixen 2021C2 Pumps On Sale Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Ideal Vacuum XG-110 Portable Digital Thermocouple Controllers On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3

Matheson Model 18H Single Stage General Purpose Brass Regulator, No Inlet, Delivery Pressure Range 10-200 PSIG, SEQ18HNI

Condition:
  New
Part Number:
  P109555
Warranty:
  Full Manufacturer's Warranty

Available Now   1  

Sale: £692.74

Matheson Model 18H Single Stage General Purpose Brass Regulator, No Inlet, Delivery Pressure Range 10-200 PSIG, SEQ18HNI 692.74
Currency: Pound Sterling (GBP)

Description

Matheson Model 18H Single Stage General Purpose Brass Regulator
SEQ18HNI, No Inlet



A CGA fitting is the standardized system for the attachment of a compressed gas cylinder to the required regulator or transfer line. The three digit number, CGA (XXX), corresponds to specific gasses which that fitting is tailored for. This regulator is not equipped with a CGA-Inlet connection. See CGA Connection Chart.pdf in the downloads section for specific gas types and associated inlets, then browse our CGA-Inlet section to tailor your regulator to your application's needs.

Regulator Specifications
  • Maximum Inlet Pressure: 3000 psig (20,700 kPa)
  • Maximum Flow Rate: 5000 CFH (2360 LPM)(At 2000 psig, N2)
  • Flow Capacity (Cv): 0.17 (without outlet valve)
  • Operating Temperature: -20°F to 140°F (-29°C to 60°C)
  • Porting (Regulator Body): 1/4” NPT Female
  • Porting Configuration: 2 High, 2 Low
  • Delivery Pressure Range: 10-200 PSIG
  • Delivery Pressure Gauge: 0-400 PSIG
  • Cylinder Pressure Gauge: 0-4000 PSIG

This is a Matheson Single Stage Brass regulator with a 1/4 in MNPT outlet connection (with loose 1/4 in hose barb) and 1/4 in FNPT body porting. It comes equipped with 2 inch inlet and delivery pressure gauges, outlet needle valve, Neoprene seals, chrome plated brass bonnet, and a PTFE Teflon seat.

This Matheson series 18, model 18H regulator is to be used in applications requiring delivery pressures up to 200 PSIG and can accept a maximum inlet pressure of 3000 PSIG. This regulator is suitable for a variety of applications that require gasses that are 99.995% or lower purity. This regulator is not suitable for any application requiring the supply of corrosive gas (non-corrosive gas applications only).

Single-Stage vs. Two-Stage

Both single-stage and two-stage regulators operate by reducing the pressure of gas supplied by a cylinder to an appropriate output level. The intake and delivery pressure ranges of regulators do not depend on how many stages they have, but by each regulators mechanical characteristics. When considering a single vs. a two-stage regulator there are two things to keep in mind: Droop and Supply Pressure Effect. Droop is the decrease in output pressure caused by an increase in flow rate. Supply Pressure Effect is simply the variation in delivery pressure from the cylinder to the regulator.

Single Stage regulators will experience less droop with varying flow rates but a large supply pressure effect and need to be monitored and adjusted by an operator or used in applications where supply pressure will remain constant. Two-Stage regulators inherently control for variations in supply pressure while producing a constant output and therefore can be used without an operator present and in applications which require a very specific delivery pressure. The specification sheet for this series of regulator can be found in the downloadable section as a .PDF.
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com



Press ESC to Close


deepbox image 2
load time = 1.8984