× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Product Image 1
Product Image 2
Product Image 3

Agilent Varian HS-16 Standard Cold Cap Replacement, Diffusion Vacuum Pump Parts, 79299301

Condition:
  New
Part Number:
  P106992
Warranty:
  Varian Warranty

Out of Stock   

Sale: Kr250,420.73

Agilent Varian HS-16 Standard Cold Cap Replacement, Diffusion Vacuum Pump Parts, 79299301 250420.73
Currency: Icelandic Króna (ISK)

Description

Agilent Varian HS-16 Diffusion Pump Replacement Standard Cold Cap.
Agilent Varian PN 84358301.

These Agilent Varian HS-16 diffusion pump standard cold caps are a replacement part that can be installed at the customer's location. There are two types of cold caps, standard and Halo Baffle. The type of cold cap used will influence factors, such as, oil backstreaming and final pumping speed of the diffusion pump. For example, the Halo Baffle Cold Cap is an option that fits inside the HS-16 pumps in place of the standard cold cap. The Halo Baffle stops backstreaming as effectively as an optically dense baffle, yet it retains 60% of the pump’s speed. Residual backstreaming is so low that it cannot be measured by the American Vacuum Society’s standard collection method. For location of the cold cap please see item #1 on diagram exploded view & parts illustration shown below. For removal installation procedures of cold cap see page 38 of instruction manual PDF below. These standard cold caps are OEM original Agilent Varian replacement parts with part number 79299301.

Brochure

ITEM DESCRIPTION PART NO.
1 Standard Cold Cap Assembly - Includes 10-32 SST Rd Hd screw & 10-32 SST Hex nut 79299301
1 Water-Cooled Halo Baffle K0143316
2 Cold Cap Water Connection:
Cold Cap Gasket/Grommet (Kit of 4)L8839301
Cold Cap Nut & Followers KitL8840301
3 Jet Assembly 83612401
4 Jet Coupling L6367301
5 Foreline Baffle Assembly 80798301
6 Sight Glass Service Kit for Pumps Built Before 1995:
3 Glass TubesF1755008
2 Brass Union 1/4 OD x 1/4 MPT622568108
2 Brass Elbow 69FL 6x4, 169VL6-4623451012
8 O-ring, Viton, Parker No. 2-011660892011
8 O-ring, Viton, Parker No. 2-111660892111
3 O-ring, Viton, Parker No. 2-221660892221
3 O-ring, Viton, Parker No. 2-213660892213
F6097301
6 Sight Glass Service Kit for Pumps Built After 1995 K8475001
7 Threaded Plug, Fill & Drain 77261001
8 Upper Thermal Switch, Temperature Setting 185°C K9050001
9 Lower Thermal Switch, Temperature Setting 390°C K9050002
10 Heater Nickel Wire 80 Inches, 14 AWG (2 per heater required) X3900-68006
10 Dalton Heater Wire 120 inches, 10 AWG (2 per heater required) X3900-68000
10b Heater Wiring Connection Box
Nickel Lug for No. 14 AWG 648056329
11 Heaters (Thtee heaters required per pump)
200 V / 2700 watt Heater Element With Leads647316025
200 V / 3200 watt Heater Element With Leads647316027
240 V or 415 V / 2700 watt Heater Element With Leads647316020
240 V or 415 V / 3200 watt Heater Element With Leads647316023
400 V / 2700 watt Heater Element With Leads647316037
400 V / 3200 watt Heater Element With Leads647316038
430 V / 2700 watt Heater Element With Leads647316039
430 V / 3200 watt Heater Element With Leads647316040
440 V / 2700 watt Heater Element With Leads647316041
440 V / 3200 watt Heater Element With Leads647316042
480 V / 2700 watt Heater Element With Leads647316030
480 V / 3200 watt Heater Element With Leads647316033
240 V or 415 V / 2700 watt Heater Element No Leads.
Used on Pumps Built Before May 1990
647316035
480 V / 2700 watt Heater Element No Leads.
Used on Pumps Built Before May 1990
647316045
12 Heater Crush Plate, required with heater replacement K4919001
13 Heater Clamping Plate K4917001
14 Heater Insulation Blanket 79309001
15 Heater Cover Plate 79308001
O-Ring Kit includes:
1 Butyl O-ring for ASA Inlet Flange48214001
1 O-ring for Foreline Flange Buna Parker 2-348660890348
8 Fill and Drain O-rings, Viton Parker 2-213660892213
4 O-rings, Viton Parker 2-221660892221
1 Sight Glass O-ring Viton 2-232660892232
1 Graphite Sight glass GasketK8478001
K0377164
16 Butly Centering Ring for ASA Inlet Flange 48214001
17 Centering Ring for ASA Foreline Flange 660890348
17 Centering Ring for ISO Foreline Flange, 100K IC100SV
Included with ASA pumps:
16 One O-ring for ASA Inlet Flange84349002
17 One O-ring for ASA Foreline Flange 660893432
Installation and Operation Manual699901140
DC-702 diffusion pump fluid, one gallon 695472008
DC-704 diffusion pump fluid, one gallon 695474008
DC-705 diffusion pump fluid, one gallon 695475008