Keyword Part Number:
MKS 1179C Mass Flow Electronic Absolute Pressure Controller, 50 sccm N2 Equivalent, 15 Pin, Swagelok 4 VCR. MKS Instruments Part Number: 1179C00151CR1BV. The MKS 1179C is an all-metal mass flow controller designed to measure the flow of gases in a wide variety of applications. Input and output connections are Swagelok® 4 VCR® The MKS 1179C mass flow controllers are available with full scales from 10 sccm to 20 slm, providing fast, repeatable flow metering to as low as 0.1 sccm.The 1179C is a direct form-fit-function replacement for the most common mass flow meters on the market today. The standard 3-inch footprint enables the 1179C to drop directly into the same space without modifying existing gas lines. Electrical connectors are the same Type “D” connectors, with similar pin-outs, signals, and functions as their industry counterparts. The 1179C is compatible with mass flow controller power supply and display electronics from MKS or other manufacturers. Swagelok, VCR-TM Swagelok Company
Condition: New
Part Number: P1010671
Price: Kr20,578.88
Alcatel FA 101 High Vacuum Cold Cathode Penning Gauge Controller These Alcatel FA 101 high vacuum cold cathode penning gauge controllers are precision instruments designed to indicate high vacuum pressures from 1x10-2 to 1x10-7 Torr. The Alcatel FA 101 high vacuum cold cathode penning gauge can operate and display pressure from one penning gauge. These Alcatel FA 101 high vacuum ion gauge controllers operate on either 115 or 220 VAC. Ion gauge cable and ion gauge tubes are available but sold separately.
Condition: Refurbished
Part Number: P102077
Price: Kr13,565.80
MKS HPS Series 421 Cold Cathode Ionization Vacuum Gauge Controller Refurbished These MKS HPS series 421 cold cathode ionization gauge controllers is microprocessor based for versatility and added functions. Color coding relates switch position to the functions of the two push button switches making most of the operations of the controller self-evident. The LCD makes possible the presentation of more information than a typical luminescent display. It is visible in a wide range of lighting situations and over a wide viewing angle. The controller provides an analog output signal accessible at a rear panel connector. The 0 to 8 volt (1 volt per decade) signal is proportional to the log 10 pressure. To enable a computer to distinguish between vacuum with zero output, and the case where the analog output is zero because the power is off or the unit is defective, a one volt offset can be selected if desired, using DIP switch inside the controller. This makes the analog output at and below 1x 10-10 Torr equal to one. Every time the unit is turned on or switched to TEST, it performs a sequence of tests to verify correct operation. Certain malfunctions and controller faults are shown by an error code. The correct operation of all elements of the display is also tested. On the rear of the control unit are a 9 pin D-sub, SHV, and SMA connectors. The D-sub connector is for the pressure output signal and process relays, while the SHV and SMA connect the high voltage and ion current signal to the tube, respectively. See the available download section below for the MKS HPS 421 users and operations manual in pdf format.
Condition: Refurbished
Part Number: P106503
Price: Kr13,837.48
Granville Phillips 316 Convectron Gauge Cable, 50 ft Long. Granville Phillips Part Number 316009 These Granville Phillips 316 convectron gauge cables are designed to work with the convectron gauge controller. These cables are 50 foot long and have Granville-Phillips part number 316009. The Granville-Phillips 316 conventron vacuum gauge controller instruction manual and gauge configuration guide can be downloaded below in PDF format below.
Condition: New
Part Number: P106100
Price: Kr3,159.35
Used MKS Cable connects to 286 Thermocouple Gauge Controller MKS PN CB286-2-20. USED Sold As Is. The MKS 286 controller and all its accessories have been discountinued from MKS Instruments. We often have used cables that are tested and in good working condition. These cables work for all MKS Instruments 286 dual thermocouple gauge controllers. We also offer replacement thermocouple sensors for the MKS 286 controllers. These cables are 20 feet long, are good used condition, and have MKS part number CB286-2-20.
Condition: Used
Part Number: P106117
Price: Kr3,091.32
MKS 246 Single Channel Power Supply ReadoutMKS 246 Single Channel Power Supply Readout. Designed to control and display any flow transducer. For use with Type 358, 558, 1150, 1359, 1559, 1179, 1479. The flow rate set point can be adjusted either through front panel controls or remotely through the rear panel analog interface. This item has in excellent condition. Please call 505-872-0037 today for more information.
Condition: Refurbished
Part Number: P10381
Price: Kr11,929.73
MKS PDR-C-1C Digital Power Supply and Digital Readout Capacitance Manometer Controller The MKS PDR-C-1C digital power supply and digital readout capacitance manometer controller is a single-channel version, with LCD display and can control a single Baratron pressure transducer. These MKS PDR-C-1C digital power supply and digital readouts provide + and -15 VDC and can read the 0 - 10 VDC output from most MKS capacitance manometers. New cables for these MKS PDR-C-1C digital power supply and digital readouts are available here at Ideal Vacuum Products. Please call (505) 872-0037 for more information.
Condition: Rebuilt
Part Number: P1010951
Price: Kr6,339.75
MKS Instruments 290 High Vacuum SINGLE Hot Cathode Ion Gauge Controller These MKS Instruments 290 ion gauge controllers feature autorunning & process control. They are precision instrument designed to indicate high vacuum pressures from a SINGLE ION GAUGE TUBE to 1x10-3 to 1x10-8 Torr. The MKS 290 can operates and displays pressure from one ion gauge tube. The MKS 290 ion gauge controller has two independent ionization gauge set points to provide process control over 5 decades of high vacuum pressure. The basic unit is comprised of a power supply, electrometer, emission controller and ion gauge meter. These MKS Instruments 290 high vacuum ion gauge controllers operate on either 115 or 220 VAC. Ion gauge cable and ion gauge tubes are available but sold separately.
Condition: Refurbished
Part Number: P102073
Price: Kr13,565.80
Granville Phillips 316 Convectron Gauge Controller, Set Up To Read Three Convectron GaugeThese Granville Phillips 316 convectron gauge controllers are multi-gauge controller that are built to operate up to 3 convectron gauge tube sensors. The Granville Phillips 316 uses model 275 convectron tube sensors, which can measure pressure from atmosphere to 10-4 Torr. These controllers can be operated on 115 or 220 VAC. Availability and options on these refurbished Granville Phillips 316 controllers may vary so please call and get a quotation, (505) 872-0037.We do have New Granville Phillips 316 controllers available that can be configured with different options, for 3 convectron gauges, with option process control for set points, and optional RS-232/485 communication. We also sell separately a wide selection of new 275 convectron gauge cables and sensors. The operation and instruction manual for the Granville Phillips 316 is available for download below.
Condition: Refurbished
Part Number: P105200
Price: Kr20,382.77
Granville Phillips 316 Convectron Gauge Controller, Operates 3 Convectron Gauges, with Optional Process Control, and RS-232 Communication These Granville Phillips 316 convectron gauge controllers are multi-gauge controller that are built to operate up to 3 convectron gauge tube sensors. They also include the optional process control and RS-232/485 communication capabilities. The Granville Phillips 316 uses model 275 convectron tube sensors, which can measure pressure from atmosphere to 10-4 Torr. These controllers can be operated on 115 or 220 VAC. Availability and options on these refurbished Granville Phillips 316 controllers may vary so please call and get a quotation, (505) 872-0037. We do have New Granville Phillips 316 controllers available that can be configured with different options, for 3 convectron gauges, with option process control for set points, and optional RS-232/485 communication. We also sell separately a wide selection of new 275 convectron gauge cables and sensors. The operation and instruction manual for the Granville Phillips 316 is available for download below.
Condition: Refurbished
Part Number: P105201
Price: Kr22,871.89
Granville Phillips 360 UHV Stabil-Ion Single Ion Gauge Controller With Dual Ion Gauge Rebuilt This Granville Phillips (Model 360) Stabil-Ion Ion gauge controller with dual ion gauge control is a precision instrument designed to indicate vacuum pressures down to 10-11 Torr with UHV ion gauges. The basic unit is comprised of a power supply, electrometer, emission controller and ion gauge meter. This controller comes complete with instruction manual, is in excellent condition and comes with 90 Day Warranty.
Condition: Refurbished
Part Number: P1010531
Price: Kr24,320.60
Granville Phillips 360 UHV Stabil-Ion Single Ion Gauge Controller With Dual Convectron Gauge Control This Granville Phillips (Model 360) Stabil-Ion Ion gauge controller with single ion gauge and dual convectron gauge control and are a precision instrument designed to indicate vacuum pressures down to 10-11 Torr with UHV ion gauges. The basic unit is comprised of a power supply, electrometer, emission controller and ion gauge meter. This controller comes complete with instruction manual and is in excellent condition and comes with 90 Day Warranty.
Condition: Refurbished
Part Number: P106102
Price: Kr24,320.60
Used MKS Cable connects to 286 Thermocouple Gauge Controller MKS PN CB286-2-10. The MKS 286 controller and all its accessories have been discountinued from MKS Instruments. We often have used cables that are tested and in good working condition. These cables work for all MKS Instruments 286 dual thermocouple gauge controllers. We also offer replacement thermocouple sensors for the MKS 286 controllers. These cables are 10 feet long and are in used but working condition.
Condition: New
Part Number: P106116
Price: Kr2,782.19
Varian NRC 840 High Vacuum Ion Gauge Controller With Dual ThermocoupleThese Varian (Model NRC 840) ion gauge controllers feature dual thermocouple gauges, 1 to 1x10-8 Torr. The two independent thermocouple gauges allow for pressure measurement in the range of 0.001 to 1 Torr while the ion gauge allows for pressure measurement in the 1x10-3 to 1x10-8 Torr range. The basic unit is comprised of a power supply, electrometer, emission controller and ion gauge meter. These Varian NRC 840 high vacuum ion gauge controllers operate on either 115 or 220 VAC. Ion gauge cable and ion gauge tubes are available but sold separately.
Condition: Refurbished
Part Number: P104256
Price: Kr19,769.27
Varian 842 & 843 Glass Ion Gauge Cable, 10ft Long These ion gauge cables connect the Varian 842 & 843 ion gauge controller to one glass ion gauge tube. These cable are 10ft long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.
Condition: New
Part Number: P102072
Price: Kr4,560.97
Varian 843 Thermocouple Gauge Cables, 10ft Long These ion gauge cables connect the Varian 843 ion gauge controller to one Varian 531 thermocouple gauge tube. These cable are 10ft long. Ion gauge controllers, ion gauge tubes, and thermocouple sensors are also available but sold separately.
Condition: New
Part Number: P102076
Price: Kr1,940.44
Varian Multi Gauge & SenTorr Gauge Controller to Hot Cathode Glass Ion Gauge Tube Cable, (Varian, Inc. models 563, 564, 571, or 572), non-bakeable, R32443010 This is a Varian Agilent signal cable and hooks up to the Multi-Gauge and SenTorr Gauge Controllesr to the Varian Glass Ion Sensor Tubes, 563, 564, 571, 572. Cable standard 10 foot length. This is the cable only all gauges and vacuum controllers sold separately on this website. Can be used with the following Varian Agilent Controllers: Multi-Gauge Controller SenTorr Controller
Condition: New
Part Number: P104370
Price: Kr4,075.00
Varian Multi Gauge & SenTorr Gauge Controller to Hot Cathode Nude Ion Gauge Tube Cable, 10 foot length, non-bakeable. PN R32453010 This is a Varian Agilent signal cable and hooks up to the Multi-Gauge & SenTorr Gauge Controller to the Varian Glass Ion Sensor Tubes, UHV-24 or UHV-24p. Cable standard 10 foot length. This is the cable only. all gauges and vacuum controllers sold separately on this website. Can be used with the following Varian Agilent Controllers: Multi-Gauge Controller SenTorr Controller
Condition: New
Part Number: P104371
Price: Kr3,824.82