Keyword Part Number:
Pfeiffer HiPace 800 Turbo Pump with TC 400 Drive Unit ISO-K 200 Inlet Flange 790 l/s Pumping Speed Water-Cooled. Pfeiffer Part Number: PM P04 300. Pfeiffer HiPace 800 turbomolecular high-vacuum pumps with an ISO-K 200 inlet flange have a pumping speed of 790 liters per second (l/s) and an ultimate pressure of 7.5 x 10-8 Torr. This Pfeiffer HiPace 800 pump comes with an integrated TC 400 drive unit side-mounted to the pump, and has an ISO KF-25 exhaust foreline flange. The pump can be mounted in any orientation. 48 VDC input power at a maximum of 420 Watts is required. This HiPace 800 turbo pump with ISO-K 200 inlet and TC 400 drive unit comes standard with a water cooling kit and has Pfeiffer part number: PM P04 300. The included TC 400 drive unit is a compact onboard controller which includes an RS485 communication interface, a D-sub connector for remote operation, and two accessory ports (to control either an air-cooling fan or solenoid vent valve). For Original Equipment Manufacturer (OEM) and system integration applications, all that is needed to start the pump is a suitable 48 VDC power supply along with start/stop logic. For laboratory applications we recommend the 400 Watt Pfeiffer OmniControl 400 controller which can both supply power and control the pump. The OmniControl 400 is a bench top or rack mountable remote user interface/power source, which communicates with and provides full monitoring and control of Pfeiffer HiPace series turbo pumps through RS485. We offer a variety of optional accessories, including the OmniControl 400 pump controller, inlet screens, a forced air-cooling kit, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only). Pfeiffer HiPace 800 turbo pump with ISO-K 200 inlet and TC 400 drive unit specifications: Part Number: PM P04 300 Inlet Flange: ISO-K 200 (flanges connect with double-claw clamps) Base Pressure: 7.5 x 10-8 Torr Operating Speed: 49,200 RPM Mounting orientation: Any Pumping Speed: 790 l/s Cooling Method Standard: Water (100 l/h, 15 to 25 °C) Cooling Method Optional: Forced Air Exhaust Flange: KF-25, G 1/4” (BSPP) Venting Connection: G 1/8” (BSPP) Integral Controller: TC 400 Drive Unit Operating Voltage: 48 VDC Maximum Power: 420 Watts Run-up Time: 2 Min. Interface: RS485 through M12 Connector Remote: High Density 26-Pin Sub-D Connector Accessory Ports: Two M12 Sockets, Labeled A and B Recommended Roughing Pump: HiScroll 12 Dry Scroll Pump The Pfeiffer Vacuum HiPace series of turbopumps feature a unique rotor design with proven hybrid bearings. HiPace pumps achieve high pumping speeds and high gas throughput as well as high compression for light gases. HiPace pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures and offer enhanced pumping speeds across all gas species. HiPace hybrid bearings are a combination of a ceramic ball bearing on the fore vacuum side and a permanent magnetic radial bearing on the high-vacuum side. This bearing technology does not require electromagnets and has an extended service life with typical maintenance intervals of approximately 4 years. In addition to enhanced performance, all HiPace turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decreases downtime. Pfeiffer HiPace pumps with a Conflat CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat-flanged HiPace pumps can be baked up to 120 °C if the turbo is water cooled. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments The pump instruction manual and Pfeiffer HiPace pump product brochures are available in the downloads.
Condition: New
Part Number: P1012623
Price: Rs रु3,198,679.20
Regular Price: Rs रु3,763,152.00
Pfeiffer HiPace 800 Turbo Pump with TC 400 Drive Unit Conflat CF 10.0 In. Inlet Flange 790 l/s Pumping Speed Water-Cooled. Pfeiffer Part Number: PM P04 301. Pfeiffer HiPace 800 turbomolecular high-vacuum pumps with a DN200 CF Conflat CF 10.0 inch inlet flange have a pumping speed of 790 liters per second (l/s) and an ultimate pressure of 3.5 x 10-10 Torr. This Pfeiffer HiPace 800 pump comes with an integrated TC 400 drive unit side-mounted to the pump, and has an ISO KF-25 exhaust foreline flange. The pump can be mounted in any orientation. 48 VDC input power at a maximum of 420 Watts is required. This HiPace 800 turbo pump with CF 10.0" inlet and TC 400 drive unit comes standard with a water cooling kit and has Pfeiffer part number: PM P04 301 . The included TC 400 drive unit is a compact onboard controller which includes an RS485 communication interface, a D-sub connector for remote operation, and two accessory ports (to control either an air-cooling fan or solenoid vent valve). For Original Equipment Manufacturer (OEM) and system integration applications, all that is needed to start the pump is a suitable 48 VDC power supply along with start/stop logic. For laboratory applications we recommend the 400 Watt Pfeiffer OmniControl 400 controller which can both supply power and control the pump. The OmniControl 400 is a bench top or rack mountable remote user interface/power source, which communicates with and provides full monitoring and control of Pfeiffer HiPace series turbo pumps through RS485. We offer a variety of optional accessories, including the OmniControl 400 pump controller, inlet screens, a forced air-cooling kit, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only). Pfeiffer HiPace 800 turbo pump with CF 10.0" inlet and TC 400 drive unit specifications: Part Number: PM P04 301 Inlet Flange: Conflat CF 10.0 Inch Base Pressure: 3.5 x 10-10 Torr Maximum Bakeout Temperature at High Vacuum Flange: 120 °C Operating Speed: 49,200 RPM Mounting orientation: Any Pumping Speed: 790 l/s Cooling Method Standard: Water (100 l/h, 15 to 25 °C) Cooling Method Optional: Forced Air Exhaust Flange: KF-25, G 1/4" (BSPP) Venting Connection: G 1/8” (BSPP) Integral Controller: TC 400 Drive Unit Operating Voltage: 48 VDC Maximum Power: 420 Watts Run-up Time: 2 Min. Interface: RS485 through M12 Connector Remote: High Density 26-Pin Sub-D Connector Accessory Ports: Two M12 Sockets, Labeled A and B Recommended Roughing Pump: HiScroll 12 Dry Scroll Pump The Pfeiffer Vacuum HiPace series of turbopumps feature a unique rotor design with proven hybrid bearings. HiPace pumps achieve high pumping speeds and high gas throughput as well as high compression for light gases. HiPace pumps have both turbomolecular and drag stages for improved tolerance to higher backing line pressures and offer enhanced pumping speeds across all gas species. HiPace hybrid bearings are a combination of a ceramic ball bearing on the fore vacuum side and a permanent magnetic radial bearing on the high-vacuum side. This bearing technology does not require electromagnets and has an extended service life with typical maintenance intervals of approximately 4 years. In addition to enhanced performance, all HiPace turbo pumps have field serviceable oil cartridges and shaft bearings which dramatically decreases downtime. Pfeiffer HiPace pumps with a Conflat CF flange are true ultra-high vacuum (UHV) pumps with an ultimate pressure into the 10-10 Torr range (if all-metal intake seal gaskets are used and the vacuum chamber is completely cleaned and baked out). Turbo pumps with ISO flanges are limited (by permeation and outgassing of the rubber/elastomer O-ring seals) to an ultimate pressure in the 10-8 Torr range. The intake of Conflat-flanged HiPace pumps can be baked up to 120 °C if the turbo is water cooled. Typical Turbo Pump Applications include: General clean pumping applications Scanning Electron Microscopes - SEM Beam lines and high energy physics Mass Spectrometry Electron Microscopy Sample Preparation Research and Development High Energy Physics Industrial Semiconductor Coatings Surface Science Instruments The pump instruction manual and Pfeiffer HiPace pump product brochures are available in the downloads.
Condition: New
Part Number: P108957
Price: Rs रु3,198,679.20
Regular Price: Rs रु3,763,152.00
Pfeiffer TC 400 Electronic Drive Unit for HiPace Turbo Pumps 300, 350, 450, 700, 800. Pfeiffer Part Number: PM C01 800 A. The TC 4000 electronic drive unit operates larger Pfeiffer turbo pumps and their accessories. It’s purpose is to drive, monitor and control the pump. The TC 400 is designed to work with Pfeiffer HiPace 300, 350, 450, 700, and 800 turbo pumps. It requires 24 or 48 VDC input power, normally supplied by a Pfeiffer OmniControl 300 or 400 controller through a power connection cable (part number P103408, sold separately). The TC 400 drive unit supplies power to the pump, has an RS485 communication port, and two M12 ports for connecting optional accessories such as a forced air-cooling kit, a solenoid vent valve, and/or a sealing gas valve. This unit replaces a damaged drive unit, or is required for pumps that do not include a drive unit. The TCU 400 electronic drive unit has Pfeiffer part number PM C01 800 A.
Condition: New
Part Number: P108413
Price: Rs रु496,547.23
Pfeiffer OmniControl 400 Turbo Pump Display Control Unit and Power Supply 400W 48 VDC. Pfeiffer Part Number: PE D60 100 0. The Pfeiffer OmniControl 300 turbo pump controller can be bench top or rack mounted and is designed to operate Pfeiffer HiPace 700 and HiPace 800 turbo pumps that have the integrated TC400 drive unit. The OmniControl 400 unit supplies 48 VDC at a maximum of 400 Watts to the TC 400 electronic drive unit which then powers the pump. Separate power and communication interface cables (sold separately) are needed to connect the OmniControl 400 and the TC 400 drive unit. The required power cable is part number P103408. The communication cable is part number P102287. Input power to the OmniControl 400 is 115/230 VAC and a standard C14 rear-mounted socket is provided for mains power entry (power cord not included, part number P103361). This OmniControl 400 turbo pump display control unit and power supply has Pfeiffer part number PE D70 100 0. The OmniControl 400 can control all the main parameters of the turbo pump via the 3 meter long RS485 interface cable (part number P1012287). This unit can also be used to operate and display pressure readings from Pfeiffer Active gauges if the optional Gauge/IO module is installed. Pfeiffer turbo pump accessories, including inlet screens, forced air-cooling and water-cooling kits, solenoid operated vent valves, and heater bands (for Conflat CF flanged pumps only) are available in other listings. The instruction manual for the OmniControl 400 controller and related documentation for Pfeiffer HiPace turbo pump products is available in the downloads.
Condition: New
Part Number: P1012607
Price: Rs रु552,645.17
Pfeiffer Turbo OmniControl Controller and HiScroll Roughing Pump Power Supply Cord Mains Cable 115 VAC NEMA 5-15 to IEC C13, 3 m Long. This input power supply power cord (mains cable) is used on Pfeiffer OmniControl 200, 300, 400, and DCU 110 controllers, HiScroll dry scroll roughing/backing pumps, and with other Pfeiffer products. These power cords have a standard NEMA 5-15P 115 VAC plug one one end and an IEC320 C13 female socket connector on the other. This cable is 3 meters long (10 ft.) and has 18 gauge wire and 3 conductors (18/3).
Condition: New
Part Number: P103361
Price: Rs रु7,999.73
Pfeiffer Power Connection Cable Connects HiPace Turbo Pump TC 400/ TM 700 Drive Unit To OmniControl Controller, 3 Meters Long. Pfeiffer Part Number: PM 061 352-T. This Pfeiffer power connection cable connects a HiPace turbo pump with integrated TC 400 or TM 700 electronic drive unit to an OmniControl 400 controller. The OmniControl 400 supplies power to the turbo pump through this cable. This cable is used on HiPace 300, 350, 450, 700, and 800 turbo pumps. This is 3 meter long cable pump power cable has 3 conductors and allows the OmniControl 400 to be rack mounted or located on a bench top, remote from the pump. This Pfeiffer TC 400 turbo pump drive unit or Pfeiffer TM 700 turbo pump drive unit to OmniControl 400 power connection cable has part number PM 061 352-T. This Pfeiffer turbo pump power cable connects: HiPace 300 turbo pumps with TC 400 drive unit to an OmniControl 400. HiPace 350 turbo pumps with TC 400 drive unit to an OmniControl 400. HiPace 450 turbo pumps with TC 400 drive unit to an OmniControl 400. HiPace 700 turbo pumps with TC 400 drive unit to an OmniControl 400. HiPace 800 turbo pumps with TC 400 drive unit to an OmniControl 400.
Condition: New
Part Number: P103408
Price: Rs रु48,284.34
RS485 Communication Cable M12 to M12 Connectors, Connects Pfeiffer HiPace Turbo Pump TC Drive Unit to OmniControl Controller, 3 m Long. 3m Long. This cable meets or exceeds OEM specs (OEM PN: PM 061 283-T3). This special serial cable allows RS485 communications between a Pfeiffer HiPace turbo pump TC drive unit and a Pfeiffer OmniControl or DCU controller. This interface cable has 4-pin, M12, round screw-type connectors on both ends. This cable is 3 meters long (10 ft.) and meets or exceeds OEM specs (OEM PN: PM 061 283-T3). On TC 110 drive units, which have a 15-pin D-Sub (X3) connector, a power and communications adapter cable (part number P103335 or P1011168) is used to split out the X3 connector into a pump power cable and a short RS485 communication cable (terminated with an M12 connector). This 3 meter long RS485 cable attaches to and extends that short cable. The other end of this cable connects to the M12 round connector on an OmniControl or a DCU controller. On TC 400 and TC 1200 drive units, which have a separate round M12 communications connector, this cable directly connects the drive unit to an OmniControl controller. This Pfeiffer RS485 Communication Connector connects: TC 110 drive unit on HiPace 80 and 300H turbo pumps to an OmniControl 200 or DCU 110 controller (requires adapter cable P103335 or P1011168). TC 400 drive unit on HiPace 300, 350, 450, 700 and 800, to an OmniControl 300 or 400 controller (direct connction). TC 1200 drive unit on a HiPace 1200 turbo pump, to an OmniControl 001 controller (direct connction).
Condition: New
Part Number: P1012287
Price: Rs रु31,750.75
RS485 Communication Cable M12 to M12 Connectors, Connects Pfeiffer HiPace Turbo Pump TC Drive Unit to OmniControl Controller, 10 m Long. 10m Long. This cable meets or exceeds OEM specs (OEM PN: PM 061 285 -T). This special serial cable allows RS485 communications between a Pfeiffer HiPace turbo pump TC drive unit and a Pfeiffer OmniControl or DCU controller. This interface cable has 4-pin, M12, round screw-type connectors on both ends. This cable is 10 meters long (10 ft.) and meets or exceeds OEM specs (OEM PN: PM 061 285 -T). On TC 110 drive units, which have a 15-pin D-Sub (X3) connector, a power and communications adapter cable (part number P103335 or P1011168) is used to split out the X3 connector into a pump power cable and a short RS485 communication cable (terminated with an M12 connector). This 10 meter long RS485 cable attaches to and extends that short cable. The other end of this cable connects to the M12 round connector on an OmniControl or a DCU controller. On TC 400 and TC 1200 drive units, which have a separate round M12 communications connector, this cable directly connects the drive unit to an OmniControl controller. This Pfeiffer RS485 Communication Connector connects: TC 110 drive unit on HiPace 80 and 300H turbo pumps to an OmniControl 200 or DCU 110 controller (requires adapter cable P103335 or P1011168). TC 400 drive unit on HiPace 300, 350, 450, 700 and 800, to an OmniControl 300 or 400 controller (direct connction). TC 1200 drive unit on a HiPace 1200 turbo pump, to an OmniControl 001 controller (direct connction).
Condition: New
Part Number: P1013178
Price: Rs रु46,904.52
Pfeiffer Backing Pump Shielded Relay Box Allows HiPace Turbo Pump TC Drive Unit to Control Backing Pump, M12 Connector, 20A Max. Pfeiffer Part Number: PM 071 285-X. This Pfeiffer shielded relay box allows a backing pump to be controlled by the TC 400 or TC 1200 electronic drive unit on Pfeiffer HiPace turbo pumps. The box has a 0.45 meter long communication cable which connects directly to one of the TC drive unit’s M12 accessory ports. This relay box can operate any single phase backing pump that has a starting current of up to 20A (the maximum relay contact load). This includes Pfeiffer HiScroll dry scroll and Duo series rotary vane pumps. This Pfeiffer backing pump shielded relay box has part number: PM 071 285-X. This box operates on 100-240 VAC, 50/60Hz. An appropriate AC mains input cable must be wired into the box, as well as an output cable to power the backing pump. Note that the backing pump voltage must be the same as the input power voltage. The shielded relay box operating instructions manual is available in the downloads.
Condition: New
Part Number: P108966
Price: Rs रु166,916.70
Pfeiffer Fine Inlet Centering Ring Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with DN 200 ISO-K/F 200 Flange. Pfeiffer Part Number: PM 016 221 AU. This Pfeiffer fine inlet screen (0.8 mm mesh) with centering ring has a multifunctional coating for anti-twist protection. It is used to filter the vacuum flow and keep objects from being sucked into the HiPace 800 or 120 turbo pumps. This screen has an ISO-K/F 200 flange size. Depending on the gas used, some pump speed reduction will occur when using this screen. This fine screen centering ring has Pfeiffer part number PM 016 221 AU. This screen fits: HiPace 800 with ISO-K 200 flange, Pfeiffer pump part number: PM P04 300 HiPace 1200 with ISO-F 200 flange, Pfeiffer pump part number: PM P06 001
Condition: New
Part Number: P1012629
Price: Rs रु162,338.87
Pfeiffer Fine Inlet Screen (0.8 mm) Splinter Guard fits HiPace Turbo Pumps with Conflat CF 10.0 in. Flange. Pfeiffer Part Number: PM 016 312. This Pfeiffer fine inlet screen (0.8 mm mesh) is used to filter the vacuum flow and keep objects from being sucked into the HiPace 800 or 1200 turbo pumps. This screen has a CF 10.0" flange size. Depending on the gas used, some pump speed reduction will occur when using this screen. This fine screen centering ring has Pfeiffer part number: PM 016 321. This screen fits: HiPace 800 with Conflat CF 10.0" flange, Pfeiffer pump part number: PM P04 301 HiPace 1200 with Conflat CF 10.0" flange, Pfeiffer pump part number: PM P06 002
Condition: New
Part Number: P1012630
Price: Rs रु191,776.43
Pfeiffer Radial Air Cooling Fan Unit for HiPace 700 and 800 Turbo Pumps with TC 400 Drive Unit Powered by M12 Accessory Connector. Pfeiffer Part Number: PM Z01 303 A. This Pfeiffer air cooling fan unit mounts to the side of HiPace 700 and 800 turbo pumps and provides air flow perpendicular to the pump. This air cooling unit is powered by one of the M12 accessory output ports located on the HiPace turbo pump’s integrated TC 400 drive unit. The air cooling unit will always run when the pump is on. This air cooling fan unit provides additional cooling and can increase the longevity of HiPace turbo pump’s that are water-cooled. This radial air cooling fan unit has Pfeiffer part number PM Z01 303 A.
Condition: New
Part Number: P1012608
Price: Rs रु130,486.96
Pfeiffer Water Cooling Block for HiPace 350, 450, 700, and 800 Turbo Pumps with Push-Fit Connectors for 8 mm OD Hose and G 1/8" Fittings. Pfeiffer Part Number: PM 026 068 -T. This water cooling unit fits Pfeiffer HiPace 350, 450, 700, and 800 turbo pumps. It attaches to the side of the pump with two included bolts. This water cooling block has push-fit connectors for the supply and discharge hoses (8mm OD plastic hose). The hose connections may be unscrewed and removed to make use of the integrated G 1/8” threads. This water cooling kit is required when using a flange heater band with a CF flanged pump. Pfeiffer HiPace turbo pumps also benefit from water cooling when there are high gas throughputs, cyclic operations and/or high ambient temperatures. In order to ensure long trouble-free operation, the cooling water must be clean and not contain any oils, greases or suspended solids. This water cooling unit has Pfeiffer part number: PM 026 068 -T.
Condition: New
Part Number: P1012609
Price: Rs रु97,877.02
Pfeiffer Venting Valve for Medium and Large HiPace Turbo Pumps with TC400 or TC 1200 Drive Units Normally Closed (NC) G 1/8" Male Fitting M12 Connection. Pfeiffer Part Number: PM Z01 291 B. This Pfeiffer venting valve for HiPace 300, 300C (chemical resistant), 350, 450, 700, and 800 turbo pumps with a TC 400 drive unit, and HiPace 1200 turbo pumps with a TC 1200 drive unit, screws into the G 1/8" (BSPP) vent port of the pump (sealing ring included). It ensures the controlled, automatic venting of the turbo pump after shutting down or in the event of a power failure, and limits an uncontrollable pressure rise rate in excess of the permissable maximum (15 hPa/s), thus preventing possible damage to the pump’s rotor and magnetic bearing. This valve has an M12 electical connector that plugs directly into one of the accessory ports in the turbo pump’s integrated TC 400 or TC 1200 drive unit. The TC drive unit controls and supplies power to the valve.The activation (control) of this valve for the venting connection is user configured and supported by Pfeiffer controllers (OmniControl 300, OmniControl 400, or OmniControl 001) or externally via RS485. This Pfeiffer venting valve for medium and large HiPace turbo pumps with integrated TC drive unit has part number PM Z01 291 B.
Condition: New
Part Number: P103407
Price: Rs रु173,759.16
Pfeiffer Vacuum Flange Adapter G 1/8" BSPP to KF-10 for all HiPace Turbo Pump Vent or Sealing Gas Ports. Pfeiffer Part Number: PM 033 737-T . This Pfeiffer vacuum flange adapter can be used on all HiPace turbo pumps. It screws into the G 1/8" BSPP vent or sealing gas port on the pump (sealing ring included), and converts the port into a standard KF-10 flange for easy connection to the user’s vacuum system. It can be used for connection to venting valves, sealing gas valves, power failure venting units, sealing gas throttles, etc. This vacuum flange adapter has Pfeiffer part number PM 033 737-T . This vacuum flange adapter fits the vent or gas sealing ports on all these Pfeiffer turbo pumps: HiPace 80 HiPace 300 HiPace 300C HiPace 350 HiPace 450 HiPace 700 HiPace 800 HiPace 1200
Condition: New
Part Number: P105885
Price: Rs रु45,540.88
Pfeiffer Vacuum Flange Adapter G 1/8" BSPP to KF-16 for all HiPace Turbo Pump Vent or Sealing Gas Ports. Pfeiffer Part Number: PM 016 780-T. This Pfeiffer vacuum flange adapter can be used on all HiPace turbo pumps. It screws into the G 1/8" BSPP vent or sealing gas port on the pump (sealing ring included), and converts the port into a standard KF-16 flange for easy connection to the user’s vacuum system. It can be used for connection to venting valves, sealing gas valves, power failure venting units, sealing gas throttles, etc. This vacuum flange adapter has Pfeiffer part number PM 016 780-T. This vacuum flange adapter fits the vent or gas sealing ports on all these Pfeiffer turbo pumps: HiPace 80 HiPace 300 HiPace 300C HiPace 350 HiPace 450 HiPace 700 HiPace 800 HiPace 1200
Condition: New
Part Number: P105886
Price: Rs रु17,408.96