Keyword Part Number:
Edwards QDP-40 QDP-80 Semi-Conductor Pump Inner Ring 25X30X16. This is an Edwards QDP-40 QDP-80 Semi-Conductor Pump Inner Ring 25X30X16 PN A20405017. Ideal vacuum offers rebuild service for all Edwards QDP-40 and QDP-80 dry semiconductor pumps with all blower combinations available. Please contact us for QDP pump or iQDP rebuild service.
Condition: New
Part Number: P1012035
Price: Rs रु9,893.59
Edwards iQDP-80 Semi-Conductor Vacuum Pump ISO63 Intake Kalrez 6375 O-Ring. Edwards iQDP-80 Intake O-ring - For the O-ring groove in the intake below the bolt down ISO-63 fitting. 3.1 ID x 0.21 inches CS, Kalrez 6375, High temperature, compatible with widest range of chemicals. Ideal vacuum offers rebuild service for all Edwards iQDP-40 and iQDP-80 dry semiconductor pumps with all blower combinations available. Please contact us for iQDP pump or iQDP rebuild service.
Condition: New
Part Number: P1011554
Price: Rs रु83,696.50
Edwards iQDP-40 and iQDP-80 Gas Module Mass Flow Meter 3810 - 60 L/MIN Replacement. The Edwards iQDP-40 and iQDP-80 dry semiconductor vacuum pump has a series II gas module that provides nitrogen flow rates to the vacuum pump. These nitrogen flows are needed to purge sections of the pump and provide cooling to the dry shaft seals. As these pumps age the mass flow controllers inside the gas module can become defective. Our replacement mass flow controller 3810 are designed as drop in new calibrated replacement parts. These regenerate the gas module so that it will provide the correct flows to the vacuum pump. Ideal vacuum offers rebuild service for all Edwards iQDP-40 and iQDP-80 dry semiconductor pumps with all blower combinations available. Please contact us for iQDP pump or iQDP gas module rebuild service - 505-872-0037.
Condition: New
Part Number: P1011296
Price: Rs रु79,935.86
KOFLOC Power Supply for the Gas Flow Meter Sensor 3810 on Edwards iQDP40-80 Pumps PN PSK-2TFX-15. This is a KOFLOC Power Supply for the Gas Flow Meter Sensor 3810. See the middle graphic for connections. Ideal vacuum offers rebuild service for all Edwards iQDP-40 and iQDP-80 dry semiconductor pumps with all blower combinations available. Please contact us for iQDP pump or iQDP gas module rebuild service - 505-872-0037.
Condition: New
Part Number: P1011804
Price: Rs रु147,646.27
Edwards Maintenance Kit for CDP/QDP/iQDP 40/80, PERFLUORINATED FOMBLIN GREASE, A52640820. This is a Edwards Maintenance Kit for CDP/QDP/iQDP 40/80 Pumps - PERFLUORINATED FOMBLIN GREASE KIT. This grease kit is for greasing the Bearings and O-Ring Seals on the Edwards CDP/QDP/iQDP SemiConductor Pumps.
Condition: New
Part Number: P1011294
Price: Rs रु110,999.57
Edwards Thermo Control Valve Kit for QDP-40, iQDP-40, QDP-80, iQDP-80 Semi Conductor Pumps for AVTA Valves. This is a Thermo Control Valve Kit for Edwards QDP-40, iQDP-40, QDP-80, iQDP-80 Semi Conductor Pumps. Works ONLY with TYPE AVTA Thermostatically Operated Water Control Valve. This Kit will help stop water leaks from the thermo control valve. Assembly pictures are to the side.
Condition: New
Part Number: P1011244
Price: Rs रु29,489.36
Edwards Thermo Control Valve Kit for QDP-40, iQDP-40, QDP-80, iQDP-80 Semi Conductor Pumps, Type AVTB, FJV, AVDA Valves DANFOSS This is a Thermo Control Valve Kit for Edwards QDP-40, iQDP-40, QDP-80, iQDP-80 Semi Conductor Pumps. Works ONLY with TYPE AVTB, FJV, AVDA DANFOSS Thermostatically Operated Water Control Valves. This Kit will help stop water leaks from the thermo control valve.
Condition: New
Part Number: P1011258
Price: Rs रु70,586.83
Edwards Thermo Control Valve Kit for QDP-40, iQDP-40, QDP-80, iQDP-80 Semi Conductor Pumps, Type AVTB, FJV, AVDA SLOTTED Valves This is a Thermo Control Valve Kit for Edwards QDP-40, iQDP-40, QDP-80, iQDP-80 Semi Conductor Pumps. Works ONLY with TYPE AVTB, FJV, AVDA SLOTTED. Thermostatically Operated Water Control Valves. This Kit will help stop water leaks from the thermo control valve.
Condition: New
Part Number: P1011414
Price: Rs रु98,336.04
NEW Edwards iQDP-40 and iQDP-80 Dry Semiconductor Vacuum Pump AC Power Plug PN E21909516These Edwards iQDP semiconductor dry pump AC Electrical Plugs are used to connect the iQDP pump’s electric module to the facility input power. They are designed to handle 3-Phase power from 200 to 500 volts AC. These connectors are NEW. (Power Cord Cable and Facility Electrical Receptacle Plug Not Included).
Condition: New
Part Number: P103136
Price: Rs रु70,585.48
Pump Control Box Breaker, 3 phase, 277 VAC, 25amp, Panel Mount. PN W93-X112-25These vacuum pump motor control box breakers are designed to operated at 3-phase up to 277 VAC and 25 AMP. The breakers are for panel mounting, toggle switched, 3 pole, and stud cap for electrical connections. These breakers are commonly used as motor controller switches on large rotary vane, dry semiconductor, and Root''s blower vacuum pumps.
Condition: New
Part Number: P103559
Price: Rs रु36,862.37
Edwards (i)QDP 40 and (i)QDP 80 Drystar Semiconductor Pumps, Power Cable Blower to Pump w/Motor Over Temperature Cable PN: 945-PCB2P-iQ40/80-112 This cable harness is for the Edwards QDP 40, QDP 80 and BOC Edwards iQDP 40 and iQDP 80 semiconductor booster pumps. It provides power from the blower to the pump through the Harting connector and also includes a motor overtemperature cable.
Condition: New
Part Number: P1011901
Price: Rs रु59,246.94
Edwards iQ System Terminator Plug, for iQDP and iH Dry Semiconductor Vacuum PumpsEdwards iQ System Terminator Plug, for iQDP-40 and iQDP-80 Dry Semiconductor Vacuum Pumps. Without this plug power can not be applied to the system.
Condition: New
Part Number: P103892
Price: Rs रु16,917.49
Edwards Back Shell Kit for MCM Micro TIM ModuleCPC 16/17 SocketThis is an OEM Edwards Vacuum back shell kit for the MCM Micro TIM (Micro Tool Interface Module) control module. The Tool Interface Connectors allow you to control the operation and to monitor the status of the pumping system. Back shell kit only, Micro TIM control module not inluded.
Condition: New
Part Number: P109570
Price: Rs रु49,653.94
Edwards QDP40 - iQDP40 Semiconductor Vacuum Pump Replacement Electric Motor Water Cooled D9OI C, QDP 40, 230/460V - 60HZ 3PH. PN- A07113770 This is a motor for the Drypumping System microprocessor controlled, modular, dry pump package that provides unparalleled control and monitoring facilities. i/QDP pumps have enclosed, water-cooled motors and are therefore suitable for applications in clean environments where fan cooling is unacceptable.The pump-motor is cooled by water flowing through a cooling jacket which surrounds the motor. The pump-motor cooling circuit is separate from the pump cooling circuit. The cooling-water supply and return pipelines are connected to the pump by connectors on the water services panel at one end of the pump. The iQ dry pumping system has integrated sensors, which continuously monitor key system performance parameters and give advanced warning of problems including pump and motor temperature, by way of integrated sensors. Three motor-protection thermistors are fitted to the pump-motor (one on each winding). These thermistors are solid-state devices which have an electrical resistance of 100 to 500 Ohms at normal pump-motor operational temperature. When the pump-motor is too hot, the electrical resistance rises quickly to 3000 Ohms. The thermistors are connected in series and you can use the output of the thermistors to shut down the pump because the motor is too hot. These motors are supplied configured for ‘low voltage’ operation (200-208 V at 50 Hz or 200-230 V at 60 Hz). To change the QDP80 Pump-motor to ‘high voltage’ operation, remove the pump-motor terminal-box cover, then remove the wires from the U1, V1 and W1 terminals. Reconnect the wires to the W2, U2 and V2 terminals, as per p.22 of the Edwards DRYSTAR QDP-40 IQDP-40 Operating Instructions (see downloads, at left).
Condition: New
Part Number: P108789
Price: Rs रु282,132.99
Edwards QDP80 - iQDP80 Semiconductor Vacuum Pump Replacement Electric Motor Water Cooled D9OI C, QDP 40, 230/460V - 60HZ 3PH. PN- A07115770 This is a motor for the Drypumping System microprocessor controlled, modular, dry pump package that provides unparalleled control and monitoring facilities. i/QDP pumps have enclosed, water-cooled motors and are therefore suitable for applications in clean environments where fan cooling is unacceptable.The pump-motor is cooled by water flowing through a cooling jacket which surrounds the motor. The pump-motor cooling circuit is separate from the pump cooling circuit. The cooling-water supply and return pipelines are connected to the pump by connectors on the water services panel at one end of the pump. The iQ dry pumping system has integrated sensors, which continuously monitor key system performance parameters and give advanced warning of problems including pump and motor temperature, by way of integrated sensors. Three motor-protection thermistors are fitted to the pump-motor (one on each winding). These thermistors are solid-state devices which have an electrical resistance of 100 to 500 Ohms at normal pump-motor operational temperature. When the pump-motor is too hot, the electrical resistance rises quickly to 3000 Ohms. The thermistors are connected in series and you can use the output of the thermistors to shut down the pump because the motor is too hot. These motors are supplied configured for ‘low voltage’ operation (200-208 V at 50 Hz or 200-230 V at 60 Hz). To change the i/QDP80 Pump-motor to ‘high voltage’ operation, remove the pump-motor terminal-box cover, then remove the wires from the U1, V1 and W1 terminals.
Condition: New
Part Number: P109569
Price: Rs रु403,237.76
NEW Edwards Exhaust Check Valve for IH, QDP, IQDP Dry Pumps, KF 40 Connection FlangesThese Edwards vacuum pump exhaust check valves are typically used to help prevent air from rushing backward through the pump during powered down. They are simply a one-way valve, they are design to inhibit the backwards airflow. Even with one of these check valves install the pump will eventually increase to atmospheric pressure. These check valves are helpful to efforts to prevent process powder from being sweep backwards with a large air rush. They are typically used on Edwards dry semiconductor pumps, iH, QDP, & iQDP dry pumps.
Condition: New
Part Number: P103888
Price: Rs रु216,441.74
Edwards DP QDP iQDP-80 Semi-Conductor Vacuum Pump LV STAGE Y Rotor. This is the Edwards DP QDP iQDP-80 Semi-Conductor Vacuum Pump LV STAGE Y Rotor. Ideal vacuum offers rebuild service for all Edwards DP QDP iQDP dry semiconductor pumps with all blower combinations available. Please contact us for rebuild service.
Condition: New
Part Number: P1011644
Price: Rs रु70,929.19
NEW Edwards QDP-40 iQDP-40 Pump Assembly Claw LV Y - 1 each, PN A26401145.This is an Edwards QDP40, iQDP40 claw LV Y for the Pump Assembly. Sold as 1 each.
Condition: New
Part Number: P1011978
Price: Rs रु70,929.19
NEW Edwards QDP-40 iQDP-40 Pump Assembly Claw LV X - 1 each, PN A26401144.This is an Edwards QDP40, iQDP40 claw LV X for the Pump Assembly. Sold as 1 each.
Condition: New
Part Number: P1011987
Price: Rs रु70,929.19
NEW NEW Edwards QDP-80 iQDP-80 Pump Assembly Claw 2nd Stage X - 1 each PN A40191010.This is an Edwards QDP80, iQDP80 claw 2nd Stage X for the Pump Assembly. Sold as 1 each.
Condition: New
Part Number: P1011988
Price: Rs रु70,929.19
NEW Edwards iQDP-40 and iQDP-80 Dry Semiconductor Vacuum Pump Leveler Jacking Feet (Sold as 1 each)These Edwards iQDP-40 and iQDP-80 dry semiconductor vacuum pump leveler jacking feet are used to level the pump and provent it from moving of the pump during operation. These Edwards iQDP leveling feet are sold as 1 each.
Condition: New
Part Number: P103139
Price: Rs रु9,394.86
NEW Edwards iQDP-40 and iQDP-80 Silencing Cover Latches - 1 eachThis is an Edwards iQDP pump silencing cover latch for the cover plates/panels that surround the Edwards iQDP pumps. Sold as 1 each.
Condition: New
Part Number: P103241
Price: Rs रु7,994.39
NEW Edwards iQDP-40 and iQDP-80 Replacement Castor Roller Wheel 1 each PN 21251-017 This is a Castor Wheel for Edwards iQDP-40 and iQDP-80 Semi Conductor Dry Pumps, sold as 1 each. Fit & Size: Fits Edwards: Edwards iQDP-40, iQDP-80 Semi Conductor Dry Pumps Edwards Part No. 21251-017.
Condition: New
Part Number: P103242
Price: Rs रु11,275.18
Edwards iQ Semiconductor Vacuum Pump PC Interface Kit - Desktop Computer PCI Kit (PN D372-18-100)The PC interface kit is a single pump system that can be connected and controlled by a PC, through the PC Interface Kit. The kit includes a PCI communication module, cables and the PCI card software. Used with a portable or workstation PC, it is an invaluable tool for service staff to configure and trouble-shoot the pump system. With the addition of Edwards Single Pump Monitor software allows the user to: • Display specific pump parameters on graphs • Log data to disc • Modify parameter set-points • Start and stop the pump The Edwards Single Pump monitor software can store data with the pump system (including events, measurements, serial number, and user pump identification) can be uploaded to a PC. The data can then be used service and applications staff for continuous product improvement. This is the sale of the pump interface kit only. The Edwards single pump monitor software is sold separately.
Condition: New
Part Number: P103633
Price: Rs रु281,072.20
Edwards XLR 4 Pin Cable Connects iM Communications Module to iQDP, iH, & iL Semiconductor Vacuum Pumps, 0.6 Meters Long. Edwards Part Number: D37207602. This Edwards OEM 0.6 meter long XLR 4 pin cable connects the Edwards iM Communications Module (P103634) to an iQDP, iH, or iL semiconductor vacuum pump. The iM serial port communications module allows you to use a PLC or a computer to control the operation of and to monitor the status of an iH, iL or iQ dry pumping system through the module''s internal serial communication card via RS232. For example, you can connect the Communications Module to the serial port of a PC on which you have installed a suitable SCADA (Supervisory Control And Data Acquisition program). All serial information sent to or received from the Communications Module is software derived; there is no direct electrical wiring to the sensors, pumps or valves in the dry pumping system. The communications module is connected to the Edwards iQDP, iH, or iL semiconductor vacuum pump system with this 4 pin XLR cable. The module has a serial 9 pin DIN connector for connection to the control equipment (PLC or compuer). Use a serial to USB cable to connect to a system that doesn''t have a serial port (part number P1010935). Please download the available manual.
Condition: New
Part Number: P108148
Price: Rs रु58,595.91
Edwards QDP, iQDP, iH, & iL Water Connector, Female Quick Coupling, ISO B, Brass, 3/8 Coupler Body X 3/8. Edwards QDP, iQDP, iH, & iL Water Connector, Female Quick Coupling, ISO B, Brass, 3/8 Coupler Body X 3/8 Female NPT (National Pipe Thread).
Condition: New
Part Number: P107146
Price: Rs रु13,985.81
Edwards QDP, iQDP, iH, & iL Water Connector Plug/Dust Cap, Female Quick CouplingDesigned For ISO B, 3/8 NPT (National Pipe Thread) This is the rubber plug only NO FITTING. These quick-coupling protective covers are designed to fit Edwards QDP, iQDP, iH, & iL water connector male plug caps.
Condition: New
Part Number: P107145
Price: Rs रु1,683.53
Edwards QDP, iQDP, iH, & iL Water Connector, Male Quick Coupler, ISO B, Brass, 3/8 Coupler Body X 3/8 Male NPT. Edwards QDP, iQDP, iH, & iL Water Connector, Male Quick Coupler, ISO B, Brass, 3/8 Coupler Body X 3/8 Male NPT (National Pipe Thread).
Condition: New
Part Number: P107147
Price: Rs रु8,410.90
Refurbished Edwards iQDP-40 and iQDP-80 Dry Semiconductor Vacuum Pump Silencer Exhaust-silencer A528-19-000RefurbishedThese Edwards iQDP-40 and iQDP-80 dry semiconductor vacuum pump exhaust silencers are used to silence the vacuum pump exhaust noise. They are made to be mounted under the iQDP pump frame or can be attached to outside of the pump frame. You can rotate them so they exhaust to the front or back of the pump. These Edwards silencers are refurbished.
Condition: Used
Part Number: P103138
Price: Rs रु187,143.78
Edwards iQDP-40 and iQDP-80 Dry Semiconductor Vacuum Pump Silencer Exhaust-silencer A528-19-000New Edwards SilencerThese Edwards iQDP-40 and iQDP-80 dry semiconductor vacuum pump exhaust silencers are used to silence the vacuum pump exhaust noise. They are made to be mounted under the iQDP pump frame or can be attached to outside of the pump frame. You can rotate them so they exhaust to the front or back of the pump. These Edwards silencers are new.
Condition: New
Part Number: P106064
Price: Rs रु341,309.85
Edwards QDP-40 and QDP-80 Dry Semiconductor Vacuum PumpCooling Manifold TVCEdwards Part Number PN 52840029This is the Cooling Manifold TVC for the Edwards QDP 40 and 80 semiconductor dry pumps. This is a brand new part, Edwards number 52840029).
Condition: New
Part Number: P109739
Price: Rs रु219,188.76
Edwards QDP-40 & QDP-80 Dry Semiconductor Vacuum Pump Cooling Coil AssemblyEdwards Part Number PN 52840027This is the Cooling Coil Assembly for the Edwards QDP 40 and 80 semiconductor dry pumps. This is a brand new part, Edwards number 52840027.
Condition: New
Part Number: P1010805
Price: Rs रु174,580.01
Used - Edwards AC power cord for IQDP Pumps Approx. 4 ft. length - 200, 208, 230, 380, 415, 460 VAC, 3 ph. 50/60 hz. max 50 Amps. This is a Used AC Input power cable and connector for Edwards iQDP Pumps. 4 strand copper cable approx. 4 feet long.
Condition: Used
Part Number: P1010934
Price: Rs रु37,317.96
Edwards QDP 40 & 80 or iQDP 40 & 80 LV HeadPlate for Semi Conductor Pumps. This is an Edwards QDP 40 & 80 or iQDP 40 & 80 LV HeadPlate for Semi Conductor Pumps.
Condition: New
Part Number: P1011259
Price: Rs रु235,621.01
Edwards QDP 40 & 80 or iQDP 40 & 80 LV Stage Stator for Semi Conductor Pumps. This is an Edwards QDP 40 & 80 or iQDP 40 & 80 LV Stage Stator for Semi Conductor Pumps.
Condition: New
Part Number: P1011260
Price: Rs रु237,486.50
EdwardsDP-40, DP-80, CDP-40, CDP-80, QDP-40, QDP80, iQDP-40 and iQDP-80 Timing Gears This is the set of 2 replacement timing gears for Edwards DP-40 and DP-80 Dry Vacuum Pump series designed for Semiconductor Processes. We also have a major rebuild kit available for thses pumps. We do minor and major repair work on all brand Semiconductor Dry pumps and Boosters, call us for a quote at (505) 872-0037.
Condition: New
Part Number: P109738
Price: Rs रु144,176.78
Edwards DP-80, QDP-80 and iQDP-80 HV Rotor X PN: 26401775 This is the X HV Rotor for Edwards DP-80,/QDP-80 and/iQDP-80 Dry Vacuum Pump series designed for Semiconductor Processes. We also have a major rebuild kit available for thses pumps. We do minor and major repair work on all brand Semiconductor Dry pumps and Boosters, call us for a quote at (505) 872-0037.
Condition: New
Part Number: P109789
Price: Rs रु198,727.64
This is a Edwards iQDP-80 Sight Glass. We also do minor and major repair work on all brand Semiconductor Dry pumps and Boosters, call us for a quote at (505) 872-0037.
Condition: New
Part Number: P1011413
Price: Rs रु7,767.95
Edwards DP-80, QDP-80 and iQDP-80 HV Rotor Y PN: 26401776 This is the Y HV Rotor for Edwards DP-80,/QDP-80 and/iQDP-80 Dry Vacuum Pump series designed for Semiconductor Processes. Part Number: 26401776 We also have a major rebuild kit available for thses pumps. We do minor and major repair work on all brand Semiconductor Dry pumps and Boosters, call us for a quote at (505) 872-0037.
Condition: New
Part Number: P109790
Price: Rs रु175,012.68
NEW Edwards Exhaust Check Valve KIT for IH, QDP, IQDP Dry Pumps, KF 40 Connection FlangesThis is an Edwards vacuum pump exhaust check valve kit. It typically is used to help prevent air from rushing backward through the pump during powered down. They are simply a one-way valve, and are designed to inhibit the backwards airflow. Even with one of these check valves installed the pump will eventually increase to atmospheric pressure. These check valves are helpful in efforts to prevent process powder from being swept backwards with a large air rush. They are typically used on Edwards dry semiconductor pumps, iH, QDP, & iQDP dry pumps.Exhaust Check Valve Kit Includes: (2) KF-40 Hinge Clamps(2) KF-40 Overpressure Centering Rings(1) KF-40 Exhuast Check Valve(1) KF-40 90 Degree Elbow Stainless Steel
Condition: New
Part Number: P104622
Price: Rs रु243,665.27