Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-nz
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Pfeiffer ASM340 Leak Detectors On Sale Edwards nEXT300D TStations On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nXR Multi Stage Roots Pumps On Sale Agilent Varian Helium Leak Detectors On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Pfeiffer 2005SD XP Explosion Proof Motor Rotary Vane Vacuum Pump - 1 Phase 115/220 VAC - Alcatel Adixen & Pascal
Out of Stock


Pfeiffer 2005SD XP, Explosion Proof Motor, Rotary Vane Vacuum Pump. Prepared for hydrocarbon Oil, set to 115 VAC, Class I, Group D, Class II, Group F & G, Division I, NEMA. Pfeiffer Part Number: 205SDMLAM-XP. These Pfeiffer 2005SD XP Explosion Proof Standard Pascal vacuum pumps include an explosion proof motor and are specially prepared for operation with standard hydrocarbon vacuum pump oil. These vacuum pumps are recommended when pumping air, nitrogen, water vapor or other inert or non reactive gasses. These Adixen Alcatel 2005SD XP hydrocarbon oil prepared rotary vane vacuum pumps have an excellent ultimate pressure down to 1x10-3 Torr and are commonly used for, backing turbomolecular pumps, backing diffusion pumps, backing roots pumps, refrigeration system evacuation, epoxy degassing, backing mass spectrometers, freeze drying, vacuum centrifugal applications, space research, and other vacuum processes. These Adixen Alcatel 2005 XP standard series vacuum pumps have a high pumping speed displacement of 3.8 CFM and require 1-Phase 110/230 VAC 60 Hz input power. These Pfeiffer 2005SD XP Pascal vacuum pumps can be fitted with a variety of optional accessories. These include Oil Mist Filters and Traps. These SD XP vacuum pumps are new, typically stocked in inventory, and ship with manufacturers 1-year factory direct warranty. Parts, oil, and all optional accessories for these pumps are located for easy purchase on this website. The complete operating and instructions manual can be downloaded in PDF format below. Explosion Proof Motor Specifications (XP Class, Group, & Division) Class I, Group D Class II, Group F & G Division I Typical Customer Applications That Are In Class I Environments (Flammable Gases & Vapors) Include: Spray painting and finishing areas Utility gas plants Petroleum refining plants Petroleum dispensing locations Dry cleaning facilities Dip tanks containing combustible or flammable fluids Plant facilities extracting solvents Inhalation anesthetic areas Process facilities manufacturing or using nitro-cellulose (class II as well). Aircraft hangars and fuel servicing areas. Gas stations. Typical Customer Applications That Are In Class II Environments (Combustible Dust) Include: Flour mills. Feed mills. Grain elevators and grain handling facilities. Fire work plants and storage areas. Aluminum manufacturing and storage areas. Magnesium manufacturing and storage areas. Coal preparation and handling facilities. Starch manufacturing and storage areas. Confectionary plants. Pulverized sugar and cocoa manufacturing plants. Packaging and storage plants. Spice grinding and storage plants. These explosion proof XP rotary vane vacuum pumps include an electrically sealed explosion proof motor. These explosion-proof motors are designed to limit the chance a spark from inside the motor could travel outward to ignite air born flammable vapors or materials in the laboratory where the pump is operating. Explosion proof vacuum pumps are typically needed in applications where flammable materials may accidentally leak into the room air where these pumps are used. Explosion Proof vacuum pumps are NOT designed to evacuate vapors and gas mixtures which are explosive if ignited. When the vacuum pump is used to pump flammable gases you must keep a closed air tight system by: Not opening the gas ballast, opening the gas ballast could cause air (O2) to enter the pump. Ensuring the foreline inlet and exhaust outlet are leak tight to avoid flammable gas leakage into the atmosphere or air (O2) from entering the pump housing. Using only an inert gas like Nitrogen (N2) at the gas ballast to purge or dilute harmful gases being pumped.

Condition: New



Part Number: P104272



Price: NZ$8,086.56


Regular Price: NZ$8,512.16




Currency: New Zealand Dollar (NZD)

Pfeiffer 2010SD XP Explosion Proof Motor Rotary Vane Vacuum Pump - 1-Phase 115/220 VAC - Alcatel Adixen & Pascal
Out of Stock


Pfeiffer 2010SD XP, Explosion Proof Motor, Rotary Vane Vacuum PumpPrepared for hydrocarbon Oil, set to 115 VAC, Class I, Group D, Class II, Group F & G, Division I, 210SDMLAM-XP, NEMA.These Pfeiffer 2010SD XP Explosion Proof Standard Pascal vacuum pumps include an explosion proof motor and are specially prepared for operation with standard hydrocarbon vacuum pump oil. These vacuum pumps are recommended when pumping air, nitrogen, water vapor or other inert or non reactive gasses. These Adixen Alcatel 2010SD XP hydrocarbon oil prepared rotary vane vacuum pumps have an excellent ultimate pressure down to 1x10-3 Torr and are commonly used for, backing turbomolecular pumps, backing diffusion pumps, backing roots pumps, refrigeration system evacuation, epoxy degassing, backing mass spectrometers, freeze drying, vacuum centrifugal applications, space research, and other vacuum processes. These Adixen Alcatel 2010 XP standard series vacuum pumps have a high pumping speed displacement of 6.8 CFM and require 1-Phase 110/230 VAC 60 Hz input power. These Adixen Alcatel 2010SD XP Pascal vacuum pumps can be fitted with a variety of optional accessories. These include Oil Mist Filters and Traps. These SD XP vacuum pumps are new, typically stocked in inventory, and ship with manufacturers 1-year factory direct warranty. Parts, oil, and all optional accessories for these pumps are located for easy purchase on this website. The complete operating and instructions manual can be downloaded in PDF format below. Explosion Proof Motor Specifications (XP Class, Group, & Division) Class I, Group D Class II, Group F & G Division I Typical Customer Applications That Are In Class I Environments (Flammable Gases & Vapors) Include: Spray painting and finishing areas Utility gas plants Petroleum refining plants Petroleum dispensing locations Dry cleaning facilities Dip tanks containing combustible or flammable fluids Plant facilities extracting solvents Inhalation anesthetic areas Process facilities manufacturing or using nitro-cellulose (class II as well). Aircraft hangars and fuel servicing areas. Gas stations. Typical Customer Applications That Are In Class II Environments (Combustible Dust) Include: Flour mills. Feed mills. Grain elevators and grain handling facilities. Fire work plants and storage areas. Aluminum manufacturing and storage areas. Magnesium manufacturing and storage areas. Coal preparation and handling facilities. Starch manufacturing and storage areas. Confectionary plants. Pulverized sugar and cocoa manufacturing plants. Packaging and storage plants. Spice grinding and storage plants. These explosion proof XP rotary vane vacuum pumps include an electrically sealed explosion proof motor. These explosion-proof motors are designed to limit the chance a spark from inside the motor could travel outward to ignite air born flammable vapors or materials in the laboratory where the pump is operating. Explosion proof vacuum pumps are typically needed in applications where flammable materials may accidentally leak into the room air where these pumps are used. Explosion Proof vacuum pumps are NOT designed to evacuate vapors and gas mixtures which are explosive if ignited. When the vacuum pump is used to pump flammable gases you must keep a closed air tight system by: Not opening the gas ballast, opening the gas ballast could cause air (O2) to enter the pump. Ensuring the foreline inlet and exhaust outlet are leak tight to avoid flammable gas leakage into the atmosphere or air (O2) from entering the pump housing. Using only an inert gas like Nitrogen (N2) at the gas ballast to purge or dilute harmful gases being pumped.

Condition: New



Part Number: P104271



Price: NZ$8,989.50


Regular Price: NZ$9,462.64




Currency: New Zealand Dollar (NZD)

Pfeiffer 2015SD XP Explosion Proof Motor Rotary Vane Vacuum Pump - 1-Phase 115/220 VAC - Alcatel Adixen & Pascal
Out of Stock


Pfeiffer 2015SD XP, Explosion Proof Motor, Rotary Vane Vacuum PumpPrepared for hydrocarbon Oil, set to 115 VAC, Class I, Group D, Class II, Group F & G, Division I, 215SDMLAM-XP, NEMA.These Pfeiffer 2015SD XP Explosion Proof Standard Pascal vacuum pumps include an explosion proof motor and are specially prepared for operation with standard hydrocarbon vacuum pump oil. These vacuum pumps are recommended when pumping air, nitrogen, water vapor or other inert or non reactive gasses. These Adixen Alcatel 2015SD XP hydrocarbon oil prepared rotary vane vacuum pumps have an excellent ultimate pressure down to 1x10-3 Torr and are commonly used for, backing turbomolecular pumps, backing diffusion pumps, backing roots pumps, refrigeration system evacuation, epoxy degassing, backing mass spectrometers, freeze drying, vacuum centrifugal applications, space research, and other vacuum processes. These Adixen Alcatel 2015 XP standard series vacuum pumps have a high pumping speed displacement of 10.6 CFM and require 1-Phase 110/230 VAC 60 Hz input power. These Adixen Alcatel 2015SD XP Pascal vacuum pumps can be fitted with a variety of optional accessories. These include Oil Mist Filters and Traps. These SD XP vacuum pumps are new, typically stocked in inventory, and ship with manufacturers 1-year factory direct warranty. Parts, oil, and all optional accessories for these pumps are located for easy purchase on this website. The complete operating and instructions manual can be downloaded in PDF format below. Explosion Proof Motor Specifications (XP Class, Group, & Division) Class I, Group D Class II, Group F & G Division I Typical Customer Applications That Are In Class I Environments (Flammable Gases & Vapors) Include: Spray painting and finishing areas Utility gas plants Petroleum refining plants Petroleum dispensing locations Dry cleaning facilities Dip tanks containing combustible or flammable fluids Plant facilities extracting solvents Inhalation anesthetic areas Process facilities manufacturing or using nitro-cellulose (class II as well). Aircraft hangars and fuel servicing areas. Gas stations. Typical Customer Applications That Are In Class II Environments (Combustible Dust) Include: Flour mills. Feed mills. Grain elevators and grain handling facilities. Fire work plants and storage areas. Aluminum manufacturing and storage areas. Magnesium manufacturing and storage areas. Coal preparation and handling facilities. Starch manufacturing and storage areas. Confectionary plants. Pulverized sugar and cocoa manufacturing plants. Packaging and storage plants. Spice grinding and storage plants. These explosion proof XP rotary vane vacuum pumps include an electrically sealed explosion proof motor. These explosion-proof motors are designed to limit the chance a spark from inside the motor could travel outward to ignite air born flammable vapors or materials in the laboratory where the pump is operating. Explosion proof vacuum pumps are typically needed in applications where flammable materials may accidentally leak into the room air where these pumps are used. Explosion Proof vacuum pumps are NOT designed to evacuate vapors and gas mixtures which are explosive if ignited. When the vacuum pump is used to pump flammable gases you must keep a closed air tight system by: Not opening the gas ballast, opening the gas ballast could cause air (O2) to enter the pump. Ensuring the foreline inlet and exhaust outlet are leak tight to avoid flammable gas leakage into the atmosphere or air (O2) from entering the pump housing. Using only an inert gas like Nitrogen (N2) at the gas ballast to purge or dilute harmful gases being pumped.

Condition: New



Part Number: P104273



Price: NZ$9,054.48


Regular Price: NZ$9,531.04




Currency: New Zealand Dollar (NZD)

Pfeiffer 2021SD XP Explosion Proof Motor Rotary Vane Vacuum Pump - 1-Phase 115/220 VAC - Alcatel Adixen & Pascal
Out of Stock


Pfeiffer 2021SD XP, Explosion Proof Motor, Rotary Vane Vacuum PumpPrepared for hydrocarbon Oil, set to 115 VAC, Class I, Group D, Class II, Group F & G, Division I, 221SDMLAM-XP, NEMA.These Pfeiffer 2021SD XP Explosion Proof Standard Pascal vacuum pumps include an explosion proof motor and are specially prepared for operation with standard hydrocarbon vacuum pump oil. These vacuum pumps are recommended when pumping air, nitrogen, water vapor or other inert or non reactive gasses. These Adixen Alcatel 2021SD XP hydrocarbon oil prepared rotary vane vacuum pumps have an excellent ultimate pressure down to 1x10-3 Torr and are commonly used for, backing turbomolecular pumps, backing diffusion pumps, backing roots pumps, refrigeration system evacuation, epoxy degassing, backing mass spectrometers, freeze drying, vacuum centrifugal applications, space research, and other vacuum processes. These Adixen Alcatel 2021 XP standard series vacuum pumps have a high pumping speed displacement of 14.6 CFM and require 1-Phase 110/230 VAC 60 Hz input power. These Adixen Alcatel 2021SD XP Pascal vacuum pumps can be fitted with a variety of optional accessories. These include Oil Mist Filters and Traps. These SD XP vacuum pumps are new, typically stocked in inventory, and ship with manufacturers 1-year factory direct warranty. Parts, oil, and all optional accessories for these pumps are located for easy purchase on this website. The complete operating and instructions manual can be downloaded in PDF format below. Explosion Proof Motor Specifications (XP Class, Group, & Division) Class I, Group D Class II, Group F & G Division I Typical Customer Applications That Are In Class I Environments (Flammable Gases & Vapors) Include: Spray painting and finishing areas Utility gas plants Petroleum refining plants Petroleum dispensing locations Dry cleaning facilities Dip tanks containing combustible or flammable fluids Plant facilities extracting solvents Inhalation anesthetic areas Process facilities manufacturing or using nitro-cellulose (class II as well). Aircraft hangars and fuel servicing areas. Gas stations. Typical Customer Applications That Are In Class II Environments (Combustible Dust) Include: Flour mills. Feed mills. Grain elevators and grain handling facilities. Fire work plants and storage areas. Aluminum manufacturing and storage areas. Magnesium manufacturing and storage areas. Coal preparation and handling facilities. Starch manufacturing and storage areas. Confectionary plants. Pulverized sugar and cocoa manufacturing plants. Packaging and storage plants. Spice grinding and storage plants. These explosion proof XP rotary vane vacuum pumps include an electrically sealed explosion proof motor. These explosion-proof motors are designed to limit the chance a spark from inside the motor could travel outward to ignite air born flammable vapors or materials in the laboratory where the pump is operating. Explosion proof vacuum pumps are typically needed in applications where flammable materials may accidentally leak into the room air where these pumps are used. Explosion Proof vacuum pumps are NOT designed to evacuate vapors and gas mixtures which are explosive if ignited. When the vacuum pump is used to pump flammable gases you must keep a closed air tight system by: Not opening the gas ballast, opening the gas ballast could cause air (O2) to enter the pump. Ensuring the foreline inlet and exhaust outlet are leak tight to avoid flammable gas leakage into the atmosphere or air (O2) from entering the pump housing. Using only an inert gas like Nitrogen (N2) at the gas ballast to purge or dilute harmful gases being pumped.

Condition: New



Part Number: P104274



Price: NZ$10,191.63


Regular Price: NZ$10,728.04




Currency: New Zealand Dollar (NZD)

Pfeiffer Alcatel Adixen A200 Double Distilled Hydrocarbon Vacuum Pump Oil, 1 Liter (~1 Quart) - Adixen, Alcatel, and Pascal. PN: 98201
In Stock
14
Expecting 72
Anticipated Arrival 72 on 2024-10-11


Pfeiffer Alcatel Adixen A200 Double Distilled Hydrocarbon Vacuum Pump Oil, 1 Liter (~1 Quart) - - Adixen, Alcatel, and Pascal. Pfeiffer Part Number: 98201. Pfeiffer Alcatel Adixen A200 Double Distilled Hydrocarbon Vacuum Pump Oil, 1 Liter (~1 Quart) is quality mechanical vacuum pump oil for the ultimate performance of your Alcatel Adixen Rotary Vane pumps. Pfeiffer Alcatel Adixen A200 Double Distilled Hydrocarbon Oil is specially prepared by Pfeiffer to meet the Rotary Vane specifications providing low backstreaming excellent lubrication and strong resistance to oxidation. Recommended for Corrosive Applications. Supplied with chemical series pumps. We recommend that you change your vacuum pump oil at least every 3 months to prolong the life of your vacuum pump. Designed by Pfeiffer for Alcatel, Adixen, Pascal Vacuum Pumps:Rotary Vane Models:2005C1, 2010C1, 2015C1, 2021C1, 2033C1, 2063C1, 2100C1, 2010C2, 2015C2, 2021C2, 2033C2, 2063C2, Vacuum Pumps.

Condition: New



Part Number: P104285



Price: NZ$202.26




Currency: New Zealand Dollar (NZD)

Pfeiffer Vacuum Oil Mist Eliminator OME-25-S for Alcatel Adixen KF25 Outlet Flange Pumps. PN: 104200
In Stock
12
Expecting 4
Anticipated Arrival 4 on 2024-12-20


Pfeiffer Vacuum Oil Mist Eliminator OME25S (OME 25 S) for Alcatel Adixen Rotary Vane Vacuum Pumps KF25 Outlet Flange Pumps. Pfeiffer Vacuum Part Number: 104200. This Pfeiffer Vacuum Oil Mist Filter Eliminator stops oil mist from escaping from the exhaust port, mainly when pumping between atmosphere pressure and 1 mbar (1 mTorr). Oil mist eliminators retain oil mist contained in the exhausted gases with a high level of separation; an internal over pressure valve prevents exceeding the maximum permissible exhaust pressure. Supplied with filter element, one KF25 centering ring, one clamp, and one additional angle port. This OME25S (OME 25 S) Alcatel Adixen Oil Mist Eliminator uses replacement cartridge P102593 located on this website. Pfeiffer Vacuum Oil Mist Filter Eliminator fits Alcatel, Adixen, and Pascal Rotary Vane Pumps:Alcatel Adixen 2005, 2010I, 2015I, 202I, 2004A, 2008A, 2012A, 2020A, 2005SD, 2010SD, 2015SD, 2021SD, 1005SD, 1010SD, 1015SD, 1021SD and other KF25 outlet pumps. Common Dimensions & Specifications:Housing made with Polyamide, filter element made with epoxy glass micro fiber. Approx. weight 12 oz., Height= 5.75 inches. Pfeiffer Part Number 104200.

Condition: New



Part Number: P102596



Price: NZ$1,268.08




Currency: New Zealand Dollar (NZD)

Replacement Cartridge for Pfeiffer Oil Mist Eliminator OME 25 S, for Alcatel, Adixen, and Pascal Vacuum Pumps.
In Stock
344


Replacement Cartridge for Pfeiffer Oil Mist Eliminator OME 25 S, for Alcatel, Adixen, and Pascal Vacuum Pumps. This is a Replacement Oil Mist Filter Cartridge for Alcatel Adixen Oil Mist Eliminator OME 25 S (OME-25-S) Part Number P102596 located on this website. Common Dimensions & Specifications: Approx. weight 12 oz., Height= 2.5 inches, Diameter= 1.25 inches. Alcatel OME25S (OME-25-S) Replacement Filter Part Number 068304. Fits Alcatel OME25S (OME-25-S) Part Number 104200.

Condition: New



Part Number: P102593



Price: NZ$43.40




Currency: New Zealand Dollar (NZD)

Pfeiffer Oil Mist Eliminator OME 25 HP for Alcatel, Adixen, and Pascal Rotary Vane Vacuum Pumps, KF25 Outlet Flange Pumps. PN: 104199
Out of Stock
Expecting 4
Anticipated Arrival 4 on 2024-11-27


Pfeiffer Oil Mist Eliminator OME25HP (OME 25 HP) for Alcatel, Adixen, and Pascal Rotary Vane Vacuum Pumps, KF25 Outlet Flange Pumps. Pfeiffer Part Number: 10499. This Oil Mist Eliminator is specially designed for applications involving frequent cycling of high pressure operation and is mainly dedicated to 2015 and 2021 Series Alcatel Adixen rotary vane vaccum pumps. This Pfeiffer Alcatel Adixen Oil Mist Filter Eliminator stops oil mist from escaping from the exhaust port, mainly when pumping between atmosphere pressure and 1 mbar (1 mTorr). Oil mist eliminators retain oil mist contained in the exhausted gases with a high level of separation; an internal over pressure valve prevents exceeding the maximum permissible exhaust pressure. Supplied with filter element, one KF25 centering ring, and one clamp. This OME25HP (OME 25 HP) Pfeiffer Alcatel Adixen Oil Mist Eliminator uses replacement cartridge P102593 located on this website. Fits Rotary Vane Pumps:Alcatel Adixen 2005, 2010I, 2015I, 2021I, 2004A, 2008A, 2012A, 2020A, 2005SD, 2010SD, 2015SD, 2021SD, 1005SD, 1010SD, 1015SD, 1021SD and other KF25 outlet pumps.Common Dimensions & Specifications:Housing made with aluminum, filter element made with epoxy glass micro fiber.Approx. weight 2.75 lbs, Height= 8 inches. Alcatel Part Number 104199.

Condition: New



Part Number: P102597



Price: NZ$1,965.97




Currency: New Zealand Dollar (NZD)

Replacement Cartridge for Pfeiffer Oil Mist Eliminator OME-25-HP. PN: 100522
Out of Stock
Expecting 36
Anticipated Arrival 36 on 2024-12-20


Replacement Cartridge for Alcatel Adixen Oil Mist Eliminator OME25HP (OME-25-HP). Pfeiffer Part Number: 100522. This is a Replacement oil mist filter cartridge for Pfeiffer oil mist eliminator OME25HP (OME-25-HP) part number P102597 located on this website. Approx. weight 12 oz., Height= 5 inches, Diameter= 2.25 inches.Material: Glass Microfiber & Epoxy Resin.Pfeiffer Part Number: 100522Fits Alcatel OME-25-HP Oil Mist Filter Part Number P102597 (Vendor PN: 104199)

Condition: New



Part Number: P102594



Price: NZ$88.30




Currency: New Zealand Dollar (NZD)

Pfeiffer Oil Return Kit must be used with OME25HP or OME25HP+Oil Mist Filter. PN: 104360
In Stock
1


Pfeiffer Oil Drain Kit, returns oil from exhaust filter - must be used with OME 25 HP Oil Mist Filter, and Pfeiffer Alcatel Adixen I and SD Series Vacuum Pumps. Pfeiffer Part Number: 104360. This is the Oil Drain Kit and must be used with oil mist eliminator OME 25 HP and Alcatel I and SD Series Vacuum Pumps. It consists of a drain pipe which is connected on one end to the bottom of the OME 25 HP, and on the other end to the inlet of the gas ballast on the Vacuum Pump. When operating the vacuum pump at high pressure, the oil accumulated in the OME HP is re-injected through the gas ballast. NOTE: When using the Oil Drain Kit, the pump is not tight when stopped. This is the Oil Drain Kit ONLY, OME 25 HP Oil Mist Filter and Vacuum Pump sold separately. Fits Rotary Vane Pumps:Pfeiffer Alcatel Adixen Pascal 2005, 2010I, 2015I, 2021I, 2005SD, 2010SD, 2015SD, 2021SD, 1005SD, 1010SD, 1015SD, 1021SD.

Condition: New



Part Number: P104546



Price: NZ$785.08




Currency: New Zealand Dollar (NZD)

Hinge Clamp KF-25 Vacuum Fittings, ISO-KF Flange Size NW-25, Aluminum
In Stock
15257


Hinge Clamp KF-25 Vacuum Fittings, ISO-KF Flange Size NW-25, AluminumThese KF-25 Hinge Clamp vacuum fittings follow ISO-KF standards and have a flange size of NW-25. They are commonly used to build foreline vacuum plumbing and process systems. They are often called quick flange fittings because they are quick to assemble. A circumferential clamp and centering ring form the vacuum seal between the connecting flanges (please see top right figure - click to enlarge). The centering ring contains a rubber elastomer o-ring. The standard sizes for quick flange fittings are KF-10, KF-16, KF-25, KF-40, and KF-50 with flange sizes NW-10, NW-16, NW-25, NW-40, and NW-50, respectively. They are made of Aluminum.KF-25 Hinge ClampISO-KF Flange Size: NW-25Common Dimensions:A=2.85" (72.40mm)B=2.12" (54mm)C=0.649" (16.50mm)

Condition: New



Part Number: P101199



Price: NZ$20.50




Currency: New Zealand Dollar (NZD)

Centering Ring KF-25 Vacuum Fittings, ISO-KF Flange Size NW-25, Stainless Steel & Viton O-ring
In Stock
16674


Centering Ring KF-25 Vacuum Fittings, ISO-KF Flange Size NW-25, Stainless Steel & Viton® O-ringThese KF-25 Centering Ring vacuum fittings follow ISO-KF standards and have a flange size of NW-25. They are commonly used to build foreline vacuum plumbing and process systems. They are often called quick flange fittings because they are quick to assemble. A circumferential clamp and centering ring form the vacuum seal between the connecting flanges (please see top right figure - click to enlarge). The centering ring contains a rubber elastomer o-ring. The standard sizes for quick flange fittings are KF-10, KF-16, KF-25, KF-40, and KF-50 with flange sizes NW-10, NW-16, NW-25, NW-40, and NW-50, respectively. They are made of corrosive resistant stainless steel with Viton® O-Ring. Viton® is well known for its excellent resistance to heat (400°F/200°C) and to aggressive fuels and chemicals. Viton® is a registered trademark of DuPont Performance Elastomers.KF-25 Centering Ring with Viton® O-RingISO-KF Flange Size: NW-25

Condition: New



Part Number: P101243



Price: NZ$16.98




Currency: New Zealand Dollar (NZD)

Ideal Vacuum XactGauge Convection-Enhanced Pirani Gauge Kit, XGC-320 Controller, XGC-321 KF-25 Gauge, 10 ft. Sensor Cable, PS, 2 Set Points
In Stock
41


Ideal Vacuum XactGauge Convection-Enhanced Pirani Gauge Kit, XGC-320 Controller, XGC-321 KF-25 Gauge, 10 ft. Sensor Cable, PS, 2 Set Points Complete Kit Includes: XactGauge XGC-320 Convection-Enhanced Controller, XGC-321 KF-25 Sensor Gauge, 3 m (10 ft.) Sensor Cable & Power Supply. Features: Inexpensive solution for Pirani type thermal conductivity gauges Convection-Enhanced Pirani sensor gauges available in 8 different flange sizes Accurate pressure measurements from 1x10-4 to 1000 Torr Compact 1/8-DIN package fits on bench or in instrument panel cutout Bright, easy to read, 4 digit OLED display Intuitive front panel controls for calibration and parameter adjustments Switch between Torr, mBar and Pa units quickly Serial RS232/RS485 DB9 I/O interface for remote control 2 set points 4 analog outputs Compatible with Granville-Phillips® 275 Convectron® and Inficon PGE050 Pirani Gauge Enhanced sensors and cables. The Ideal Vacuum XactGauge XGC-320 Convection Enhanced Pirani Gauge Controller is an inexpensive solution for simple readout of Pirani type thermal conductivity gauges with added features for ease of use and system integration. Use with any of our eight (8) XactGauge Enhanced Pirani Sensor Gauges to obtain accurate pressure measurements ranging from 1x10-4 to 1000 Torr. Our XactGauge XGC-320 Controller, conveniently housed in a compact 1/8-DIN enclosure, can be used on your benchtop or mounted in an instrument panel cutout. The bright, OLED 4 digit display is easy to read. Intuitive front panel controls allow direct gauge calibration and simple adjustment of vacuum measurement parameters. The XactGauge XGC-320 Convection-Enhanced Pirani Gauge Controller is powered by user supplied 12 to 28 VDC, 2 W, or by our XactGauge Enhanced Pirani Controller power supply. The XGC-320 Controller has a serial RS232/RS485 (DB-9) remote I/O interface, two (2) setpoints, and four (4) analog relay outputs, each rated at 1 A at 30 VDC. This XGC-320 Controller is compatible with other manufacturer’s Pirani type gauges and cables, including the Granville-Phillips® 275 Convectron® and the Inficon PGE050 Pirani Gauge Enhanced. Thermal conductivity gauges measure pressure indirectly by sensing the loss of heat from a sensor to the surrounding gas. The higher the pressure of the gas, the more heat is conducted away from the sensor. Pirani thermal conductivity gauges maintain a sensor (usually a wire) at a constant temperature and measure the current or power required to maintain that temperature. A standard Pirani gauge has a useful measuring range of about 10-4 Torr to 10 Torr. Convection-enhanced Pirani gauges take advantage of the convection current inside the sensor to extend the pressure measurement range to just above atmosphere. The XactGauge is supplied factory calibrated using Nitrogen (N2) gas. When measuring gasses other than Nitrogen/Air, accurate correction must be made for the difference in thermal conductivity between nitrogen and the gas in use, particularly at pressures above 1 Torr. DO NOT USE for explosive, corrosive or toxic gasses.

Condition: New



Part Number: P1010252



Price: NZ$2,079.50


Regular Price: NZ$2,446.46




Currency: New Zealand Dollar (NZD)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com