Keyword Part Number:
Edwards CTI Cryo-Torr 8 High Vacuum Pump, 6 inch ANSI (11 in. OD) Cryopump, 1500 l/s Air, 4000 l/s Water Vapor. Edwards Part Number: 8033167. The Edwards CTI-Cryogenics Cryo-Torr pump 8, is one of the two major components that make up the Cryo-Torr Pumping System. The second component is the Compressor (also sold on this website). This is the Cryo-Torr CTI 8 Pump, providing fast, clean pumping of all gases in the 10-3 to 10-9 Torr range. Standard applications include, Semiconductor, Aerospace & Vacuum coating as well as R&D. The cryopump operates on the principle that gases can be condensed and held at extremely low vapor pressures, achieving high speeds and throughputs. This Cryo-Torr 8 Pump is a highly-reliable and rugged unit that requires a minimum of servicing. Since the cryopump exposes no moving parts, operating fluids, or backing pumps to the vacuum, the possibility of system or process contamination from the cryopump itself is eliminated. This is the Cryo-Torr 8 Pump ONLY, compressors, cables, roughing pump and other accessories are available on this website. Descripition, Installation, Regeneration, and Maintenance Procedures are totally covered in the User’s Manual .pdf in the downloads section.
Condition: New
Part Number: P109173
Price: TT$90,429.58
Edwards CTI Cryo-Torr Cryopump 10 inch ANSI, (16 in OD) 3000 l/s Air, 9000 l/s Water, 5000 l/s Hydrogen, 2500 l/s Argon. Edwards Part Number: 8116174G001. The Edwards Cryo-Torr pump 10, is one of the two major components that make up the Cryo-Torr Pumping System. The second component is the Compressor (also sold on this website). This is the Cryo-Torr CTI 10 Pump, providing fast, clean pumping of all gases in the 10-3 to 10-9 Torr range. Standard applications include, Semiconductor, Aerospace & Vacuum coating as well as R&D. The cryopump operates on the principle that gases can be condensed and held at extremely low vapor pressures, achieving high speeds and throughputs. This Cryo-Torr 10 Pump is a highly-reliable and rugged unit that requires a minimum of servicing. Since the cryopump exposes no moving parts, operating fluids, or backing pumps to the vacuum, the possibility of system or process contamination from the cryopump itself is eliminated. This is the Cryo-Torr 10 Pump ONLY, compressors, cables, roughing pump and other accessories are available on this website. Descripition, Installation, Regeneration, and Maintenance Procedures are totally covered in the Manual.pdf in the download section.
Condition: New
Part Number: P109174
Price: TT$124,358.91
Edwards Cryo-Torr Cryopump 8200 Helium Compressor, 3 phase, Air Cooled, 208/230 VAC. Edwards Part Number: 8032549G001. For applications, process, maintenance engineers, and scientists who depend on Cryogenic Compressors in fields such as vacuum coating, semiconductor production, particle accelerators, sputter deposition systems and Molecular Beam Epitaxy. The Edwards 8200 compressor is designed to provide optimum performance with On-Board Cryopumps, On-Board Waterpumps and Cryo-Torr Cryopumps. This Edwards 8200 Three Phase Air Cooled Compressor is designed for reliable performance with a variety of Cyro-Pumps up to 8 inches in size including the CTI Cryo-Torr series. The 8200 model compressors can operate on both 50 and 60Hz, easily switchable using the frequency toggle switch, located right on the front. The 8200 can also be toggled between high and low voltage from a frontward located S1 switch; 50hz (180-212VAC), 60Hz (198-250VAC). A Users and Configuration Manual is provided by downloading the pdf. Can be used with the the following Cryo-Pumps On-Board 4, On-Board 8, On-Board 250, Cryo-Torr 8 or Cryo-Torr 250 Cryopump or On-Board Waterpump (350 refrigerator) See configuration manual .pdf below for proper installation.
Condition: New
Part Number: P108333
Price: TT$104,247.28
Regular Price: TT$122,643.88
Edwards Cryo-Torr Cryopump 8200 Helium Compressor, 1 phase, Water Cooled, 208/230 VAC. Edwards Part Number: 8032550G002. For applications, process, maintenance engineers, and scientists who depend on Cryogenic Compressors in fields such as vacuum coating, semiconductor production, particle accelerators, sputter deposition systems and Molecular Beam Epitaxy. The Edwards 8200 compressor is designed to provide optimum performance with On-Board Cryopumps, On-Board Waterpumps and Cryo-Torr Cryopumps. This Edwards 8200 Single Phase Water Cooled Compressor is designed for reliable performance with a variety of Cyro-Pumps up to 8 inches in size including the CTI Cryo-Torr series. The Edwards 8200 model compressors can operate on both 50 and 60Hz, easily switchable using the frequency toggle switch, located right on the front. The 8200 can also be toggled between high and low voltage from a frontward located S1 switch; 50hz (180-220VAC), 60Hz (198-250VAC). A Users and Configuration Manual is provided by downloading the pdf. Can be used with the the following Cryo-Pumps On-Board 4, On-Board 8, On-Board 250, Cryo-Torr 8 or Cryo-Torr 250 Cryopump or On-Board Waterpump (350 refrigerator) See configuration manual .pdf below for proper installation.
Condition: New
Part Number: P108334
Price: TT$79,548.56
Regular Price: TT$93,586.56
Edwards Cryo-Torr Cryopump 8200 Helium Compressor, 3 phase, Water Cooled, 208/230 VAC. Edwards Part Number: 8032550G001. For applications, process, maintenance engineers, and scientists who depend on Cryogenic Compressors in fields such as vacuum coating, semiconductor production, particle accelerators, sputter deposition systems and Molecular Beam Epitaxy. The Edwards 8200 compressor is designed to provide optimum performance with On-Board Cryopumps, On-Board Waterpumps and Cryo-Torr Cryopumps. This Edwards 8200 Three Phase Water Cooled Compressor is designed for reliable performance with a variety of Cyro-Pumps up to 8 inches in size including the CTI Cryo-Torr series. The 8200 model compressors can operate on both 50 and 60Hz, easily switchable using the frequency toggle switch, located right on the front. The 8200 can also be toggled between high and low voltage from a frontward located S1 switch; 50hz (180-212VAC), 60Hz (198-250VAC). A Users and Configuration Manual is provided by downloading the pdf. Can be used with the the following Cryo-Pumps On-Board 4, On-Board 8, On-Board 250, Cryo-Torr 8 or Cryo-Torr 250 Cryopump or On-Board Waterpump (350 refrigerator) See configuration manual .pdf below for proper installation.
Condition: New
Part Number: P108335
Price: TT$72,332.62
Regular Price: TT$85,097.22
Edwards Cryo-Torr Cryopump 8200 Helium Compressor, 1 phase, Air Cooled, 208/230 VAC. Edwards Part Number: 8032549G002. For applications, process, maintenance engineers, and scientists who depend on Cryogenic Compressors in fields such as vacuum coating, semiconductor production, particle accelerators, sputter deposition systems and Molecular Beam Epitaxy. The Edwards 8200 compressor is designed to provide optimum performance with On-Board Cryopumps, On-Board Waterpumps and Cryo-Torr Cryopumps. This Edwards 8200 Single Phase Air Cooled Compressor is designed for reliable performance with a variety of Cyro-Pumps up to 8 inches in size including the CTI Cryo-Torr series. The Edwards 8200 model compressors can operate on both 50 and 60Hz, easily switchable using the frequency toggle switch, located right on the front. The 8200 can also be toggled between high and low voltage from a frontward located S1 switch; 50hz (180-212VAC), 60Hz (198-250VAC). A Users and Configuration Manual is provided by downloading the pdf. Can be used with the the following Cryo-Pumps On-Board 4, On-Board 8, On-Board 250, Cryo-Torr 8 or Cryo-Torr 250 Cryopump or On-Board Waterpump (350 refrigerator) See configuration manual .pdf below for proper installation.
Condition: New
Part Number: P108332
Price: TT$78,526.79
Regular Price: TT$92,384.46
Edwards Cryo-Torr Cryopump 9600 Helium Compressor, 3 phase, Water Cooled, LOW VOLTAGE 180/230 VAC. Edwards Part Number: 8135717G001 replaces obsolete PN: 8135900G001. For applications, process, maintenance engineers, and scientists who depend on Cryogenic Compressors in fields such as vacuum coating, semiconductor production, particle accelerators, sputter deposition systems and Molecular Beam Epitaxy. The 9600 Compressor is designed expressly for a long usable life, very reliable, and is very easy to use. The 9600 compressor provides outstanding performance with all Cryo-Torr Cryopumps, On-Board Cryopumps, On-Board Waterpumps, and On-Board TurboPlus Vacuum Pumps. It is a lightweight design, with large casters for easy handling, and its power, helium, and water hookups are all easily accessible for fast installation. The 9600 requires no maintenance beyond a recommended adsorber change once every three years. Circuit protection is provided by a single row of breakers which are easily accessible at the rear panel. See manual for adsorber replacement. Remote controls are supported, giving you the flexibility of remote compressor location (but not included). Has extreme high capacity and efficient design for improved pump performance and fast regenerations. The unit is fully compatible with new and existing CTI-Cryogenics pumping systems. This unit is LOW VOLTAGE, Water Cooled, Three Phase, Input Voltage 180-230 V, 50/60 Hz, 3 Phase C series On-Board Power. Has On-Board power outputs to drive standard 1-phase(2-phase) motor On-Board and Cryo-Torr and Cryodyne pumps. A Users and Configuration Manual is provided by downloading the pdf. Can be used with the the following Cryo-Pumps Cryo-Torr 100, 7, 8, 8F, 10
Condition: New
Part Number: P108336
Price: TT$108,641.09
Regular Price: TT$127,813.08
Edwards Cryo-Torr Cryopump 9600 Helium Compressor, 3 phase, Water Cooled, HIGH VOLTAGE 380/460 VAC. Edwards Part Number: 8135705G001 replaces Obsolete PN: 8135901G001. For applications, process, maintenance engineers, and scientists who depend on Cryogenic Compressors in fields such as vacuum coating, semiconductor production, particle accelerators, sputter deposition systems and Molecular Beam Epitaxy. The 9600 Compressor is designed expressly for a long usable life, very reliable, and is very easy to use. The 9600 compressor provides outstanding performance with all Cryo-Torr Cryopumps, On-Board Cryopumps, On-Board Waterpumps, and On-Board TurboPlus Vacuum Pumps. Edwards CTI Cryo-Torr Cryopump 9600 Helium Compressor It is a lightweight design, with large casters for easy handling, and its power, helium, and water hookups are all easily accessible for fast installation. The 9600 requires no maintenance beyond a recommended adsorber change once every three years. Circuit protection is provided by a single row of breakers which are easily accessible at the rear panel. See manual for adsorber replacement. Remote controls are supported, giving you the flexibility of remote compressor location (but not included). Has extreme high capacity and efficient design for improved pump performance and fast regenerations. This unit is HIGH VOLTAGE, Water Cooled, Three Phase, Input Voltage 380/415V 50Hz, 380/460V 60Hz C series On-Board Power. Has On-Board power outputs to drive standard 1-phase(2-phase) motor On-Board and Cryo-Torr and Cryodyne pumps. A Users and Configuration Manual is provided by downloading the pdf. Can be used with the the following Cryo-Pumps Cryo-Torr 100, 7, 8, 8F, 10
Condition: New
Part Number: P108337
Price: TT$103,209.09
Regular Price: TT$121,422.44