Skip to main content
× Home Services Products Catalogs Downloads TechSupport About Contact Careers (505) 872-0037

(505) 872-0037

Shopping Cart Icon
Cart
 
Login Icon
Login
Language Selector
en-tu
×
Americas
Europe
Middle East & Africa
Asia Pacific & Japan
Ideal Vacuum XG-120 Digital Thermocouple Gauges On Sale Ideal Vacuum XGC-320 Portable Digital Thermocouple Controllers On Sale Edwards nXR Multi Stage Roots Pumps On Sale Edwards nEXT300D TStations On Sale Agilent IDP-10 Dry Scroll Vacuum Pumps On Sale Agilent Varian Helium Leak Detectors On Sale

Keyword       Part Number:      

× Vacuum Pumps Modular Vacuum Chambers Stainless Steel Vacuum Chambers Aluminum Vacuum Chambers ExploraVAC Unlimited Chambers ExploraVAC Vacuum Chambers Fittings and Flanges Feedthroughs Vacuum Valves Rebuild Kits, Parts, And Motors Vacuum Fluids, Oils, and Greases Turbo Pumps And Controllers Filters Traps and Silencers Convection and Vacuum Ovens Leak Detection and RGA Vacuum Pressure Measurement Recirculating Chillers And Water Baths
×

Load

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-16 Flanges, 110VAC, 60 Hz Solenoid
In Stock
4


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-16 Flanges, 110VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010136



Price: ₺17,174.14




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-25 Flanges, 110VAC, 60 Hz Solenoid
In Stock
10


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-25 Flanges, 110VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010137



Price: ₺18,523.00




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-40 Flanges, 110VAC, 60 Hz Solenoid
In Stock
8


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-40 Flanges, 110VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010138



Price: ₺19,369.14




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-50 Flanges, 110VAC, 60 Hz Solenoid
In Stock
7


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-50 Flanges, 110VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010139



Price: ₺21,306.23




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-16 Flanges, 220VAC, 60 Hz Solenoid
In Stock
7


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-16 Flanges, 220VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010181



Price: ₺17,174.14




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-25 Flanges, 220VAC, 60 Hz Solenoid
In Stock
14


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-25 Flanges, 220VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010182



Price: ₺18,523.00




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-40 Flanges, 220VAC, 60 Hz Solenoid
In Stock
17


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-40 Flanges, 220VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any roughing or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump (turbo) from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Very compact - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Available flange connection sizes: NW KF10, KF16, KF25, KF40, KF50 Non-restrictive flow for flange sizes smaller than KF-50 Solenoid voltage options: 110VAC, 220VAC or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every Valve is leak tested to 1x10-8 atm cc/sec Helium before delivery Use with clean, dry, air only The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet side of the mechanical pump. It is available with either KF-10, KF-16, KF-25, KF-40, or KF-50 vacuum flanges (same flange on both ends) and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. We can supply the DPV in a custom configuration with different flanges on either end to fit your application requirements for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than any other isolation valve available. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air only.

Condition: New



Part Number: P1010183



Price: ₺19,369.14




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-50 Flanges, 220VAC, 60 Hz Solenoid
In Stock
4


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-50 Flanges, 220VAC, 60 Hz Solenoid. The Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010184



Price: ₺21,306.23




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-16 Flanges, 24VDC Solenoid
In Stock
4


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-16 Flanges, 24VDC SolenoidThe Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010186



Price: ₺17,174.14




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-25 Flanges, 24VDC Solenoid
In Stock
7


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-25 Flanges, 24VDC SolenoidThe Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010187



Price: ₺18,523.00




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-40 Flanges, 24VDC Solenoid
In Stock
12


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-40 Flanges, 24VDC SolenoidThe Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010188



Price: ₺19,369.14




Currency: Turkish Lira (TRY)

Ideal Vacuum Delta-P Anti-Suckback System Protection Valve, NW KF-50 Flanges, 24VDC Solenoid
In Stock
15


Ideal Vacuum Delta-P Anti-Suckback System Protection Valve with NW KF-50 Flanges, 24VDC SolenoidThe Delta-P Valve (DPV) is an important component of any rough or high vacuum system. The DPV provides anti-suckback and vacuum system isolation from the mechanical backing pump during a power outage. It prevents backstreaming and the migration of contaminants (e.g., rotary pump oil or scroll pump tip seal particles) into the vacuum system. It also protects a high vacuum pump from damage. FEATURES: Preserves chamber vacuum pressure during power outages Closes automatically (approx. 25 ms) upon power interruption Automatically re-opens when vacuum is restored Requires no additional power source or gasses to operate Operates on differential pressure between ambient atmosphere and roughing pump’s vacuum level Isolates high vacuum pump and/or vacuum chamber system from mechanical pump Prevents backstreaming and migration of oil or particulate contaminants into the vacuum system Mounts directly on the inlet side of the mechanical roughing pump Compact design - 3-inches in diameter and 4-1/4” in length (5” with KF50 flange ends) Works in any orientation: vertical, horizontal, or inverted Four available flange connection sizes: KF16, KF25, KF40, and KF50 Non-restrictive flow for flange sizes smaller than KF-50 Three solenoid voltage options: 110VAC, 220VAC, or 24VDC Constructed entirely of vacuum compatible materials in the U.S.A. Mean Time Between Failure (MTBF) rating of more than 10,000 cycles Every valve is leak tested to 1x10-9 atm cc/sec Helium before delivery Use with clean, dry, air or inert gases. The Delta-P Valve operates on the Differential (Delta) Pressure (P) between ambient atmosphere and the roughing/backing pump’s vacuum level. During a power failure, the mechanical pump is vented to atmosphere from its inlet flange which pushes debris towards the mechanical pump. This stops undesirable material from being swept into the system when the pump restarts. The DPV is a compact, inline unit which mounts directly on the inlet flange of the mechanical pump. It is available with either KF-16, KF-25, KF-40, or KF-50 vacuum flanges, and solenoid voltages of 120 VAC, 220 VAC or 24 VDC. The DPV can be supplied in a custom configuration with different flanges on either end for no additional cost (please inquire). DPV closure speed is approximately 25 ms, faster than other isolation valves. This is due to the reduced moving mass of our advanced piston design. Flow is unrestricted with flange sizes smaller than KF-50. A slight reduction in conductance may be experienced with pumps that have a high pumping speed and KF-50 inlet flange. The DPV can be mounted in any orientation; vertical, horizontal, or inverted. All parts that make up the DPV have been carefully selected for vacuum system compatibility and longevity. To ensure the Delta-P Valve you receive is of the highest quality, all production and assembly is done in our own manufacturing facility in Albuquerque, NM, U.S.A. Furthermore, every Delta-P Valve is helium leak tested and must meet our stringent quality control standards before it leaves our facility. Upon delivery, your Delta-P Valve is ready for immediate installation into a new or existing system. The Delta-P Valve is intended for use with clean, dry air or inert gases. For processes that use or create corrosive or toxic gasses, the valve’s solenoid breather vent must be replaced with an exhaust line that exits to the facility exhaust.

Condition: New



Part Number: P1010189



Price: ₺21,306.23




Currency: Turkish Lira (TRY)

Replacement Solenoid for Ideal Vac Delta-P and Agilent Varian Anti-Suckback Isolation Valves, 110VAC, 60Hz
In Stock
63


Replacement Solenoid for Ideal Vac Delta-P and Agilent Varian Anti-Suckback Isolation Protection Valves, 110VAC, 60Hz. 1/8 inch Female NPT Vacuum Pump Isolation Valves close rapidly when power is interrupted to prevent oil backstreaming or particle migration into your vacuum system. The valve also vents the pump from the inlet side to push any debris towards the outlet, thereby preventing it from being swept into the system when restarting the pump. This solenoid valve has Viton® seals and can withstand temperatures up to 50°C. It replaces a faulty or failed solenoid on all models of the Ideal Vacuum Delta-P and Agilent Varian Anti-Suckback Isolation Protection Valves. Replacement solenoids are available in these voltages: 110VAC (P108430) 220VAC (P108431) 24VDC (P1010132) All solenoid voltage variations fit all Ideal vacuum Delta-P and Agilent Varian Anti-Suckback valve models. So, this replacement solenoid can replace a solenoid with a different voltage should your application requirements change.

Condition: New



Part Number: P108430



Price: ₺12,008.00



Currency: Turkish Lira (TRY)

Replacement Solenoid for Ideal Vac Delta-P and Agilent Varian Anti-Suckback Isolation Valves, 220VAC, 60Hz
In Stock
63


Replacement Solenoid for Ideal Vac Delta-P and Agilent Varian Anti-Suckback Isolation Protection Valves, 220VAC, 60Hz. 1/8 inch Female NPTVacuum Pump Isolation Valves close rapidly when power is interrupted to prevent oil backstreaming or particle migration into your vacuum system. The valve also vents the pump from the inlet side to push any debris towards the outlet, thereby preventing it from being swept into the system when restarting the pump. This solenoid valve has Viton® seals and can withstand temperatures up to 50°C. It replaces a faulty or failed solenoid on all models of the Ideal Vacuum Delta-P and Agilent Varian Anti-Suckback Isolation Protection Valves. Replacement solenoids are available in these voltages: 110VAC (P108430) 220VAC (P108431) 24VDC (P1010132) All solenoid voltage variations fit all Ideal vacuum Delta-P and Agilent Varian Anti-Suckback valve models. So, this replacement solenoid can replace a solenoid with a different voltage should your application requirements change.

Condition: New



Part Number: P108431



Price: ₺11,222.21




Currency: Turkish Lira (TRY)

Replacement Solenoid for Ideal Vac Delta-P and Agilent Varian Anti-Suckback Isolation Valves, 24VDC
In Stock
35


Replacement Solenoid for Ideal Vac Delta-P and Agilent Varian Anti-Suckback Isolation Protection Valves, 24VDC. 1/8 inch Female NPTVacuum Pump Isolation Valves close rapidly when power is interrupted to prevent oil backstreaming or particle migration into your vacuum system. The valve also vents the pump from the inlet side to push any debris towards the outlet, thereby preventing it from being swept into the system when restarting the pump. This solenoid valve has Viton® seals and can withstand temperatures up to 50°C. It replaces a faulty or failed solenoid on all models of the Ideal Vacuum Delta-P and Agilent Varian Anti-Suckback Isolation Protection Valves. Replacement solenoids are available in these voltages: 110VAC, 60 Hz (P108430) 220VAC 60 Hz (P108431) 24VDC (P1010132) All solenoid voltage variations fit all Ideal vacuum Delta-P and Agilent Varian Anti-Suckback valve models. So, this replacement solenoid can replace a solenoid with a different voltage should your application requirements change.

Condition: New



Part Number: P1010132



Price: ₺14,929.15




Currency: Turkish Lira (TRY)

O-Ring Seal Replacement Kit, Viton, for all Delta-P System Isolation Protection Valves
In Stock
81


O-Ring Seal Replacement Kit, Viton, for all Delta-P System Isolation Protection Valves This O-ring kit replaces all three O-rings in any Ideal Vacuum Delta-P System Isolation Protection Valve. The two larger O-rings replace the flange end seals, the smaller O-ring replaces the actuator cup seal. All three O-rings are made of Viton for maximum vacuum system compatibility. All three O-rings should be replaced if any one of them requires replacement. The flange end O-rings should be lubricated with vacuum grease prior to reassembly of the Valve. The actuator cup O-ring should not be greased. The Delta-P Valve should be tested after O-ring replacement and Valve reassembly to ensure proper function. Instructions and test procedures are discussed in the downloadable Deltas-P User''s Manual here.

Condition: New



Part Number: P1010156



Price: ₺1,272.31




Currency: Turkish Lira (TRY)

Ideal Vacuum O-Ring Removal Tool, Non Scratch Polycarbonate, Keeps O-Ring Seals and Grooves from Damage
In Stock
53


O-Ring Removal Tool, Non Scratch Polycarbonate, Keeps O-Ring Seals and Grooves from Damage This O-ring removal tool, made of non scratch, tough polycarbonate plastic, allows you to remove O-rings from the groove without damaging either the O-ring seal or the groove. This 5-1/2" long, nearly unbreakable tool has a prying tip on one end, and a hook on the other which allows you to remove even the most stubborn O-rings, even in hard-to-reach places. This tool is a must have in your toolbox! We recommended it for installation, maintenance and service on the Ideal Vacuum Cube modular chamber system, or with any vacuum component. Note: Color may vary.

Condition: New



Part Number: P1010547



Price: ₺191.71




Currency: Turkish Lira (TRY)

Delta-P Valve Maintenance and Service Tool Kit
In Stock
8


Delta-P Valve Maintenance and Service Tool Kit This simple toolkit includes a 7/64 hex key wrench and an O-ring removal tool. It is a perfect little tool kit for maintaining and servicing ALL Ideal Vacuum Delta-P isolation valves, with KF-10 to KF-50 flange size ends. This inexpensive tool kit has just the essential tools used on the Delta-P Valve.

Condition: New



Part Number: P1010552



Price: ₺547.54



Currency: Turkish Lira (TRY)

Flange End Replacement Kit for Ideal Delta-P System Isolation Protection Valve, NW KF-16 Flange
In Stock
5


Flange End Replacement Kit for Ideal Delta-P System Isolation Protection Valve, NW KF-16 Flange Fits all Ideal Vacuum Delta-P Valves, KF-16 This is a KF-16 Flange End Replacement Kit for the Delta-P™ System Isolation Valve. This kit includes a new Viton® O-ring and 6 stainless steel, hex socket, flat head screws. This flange end, machined out of solid 6061-T6 aluminum, fits either side of the Delta-P Valve. Use it to replace a damaged one, to match ports on a mechanical pump with a different flange size, or to eliminate a flange adapter when connecting the Delta-P inlet flange to your vacuum system line. We offer Delta-P Valve Flange End Replacement Kits in five (5) sizes: KF-10, KF-16, KF-25, KF-40, and KF-50. Installation instructions for this Flange End Replacement Kit are found in the Delta-P User’s Manual downloadable here.

Condition: New



Part Number: P1010193



Price: ₺3,147.68



Currency: Turkish Lira (TRY)

Flange End Replacement Kit for Ideal Delta-P System Isolation Protection Valve, NW KF-25 Flange
In Stock
3


Flange End Replacement Kit for Ideal Delta-P System Isolation Protection Valve, NW KF-25 Flange Fits all Ideal Vacuum Delta-P Valves, KF-25 This is a KF-25 Flange End Replacement Kit for the Delta-P™ System Isolation Valve. This kit includes a new Viton® O-ring and 6 stainless steel, hex socket, flat head screws. This flange end, machined out of solid 6061-T6 aluminum, fits either side of the Delta-P Valve. Use it to replace a damaged one, to match ports on a mechanical pump with a different flange size, or to eliminate a flange adapter when connecting the Delta-P inlet flange to your vacuum system line. We offer Delta-P Valve Flange End Replacement Kits in five (5) sizes: KF-10, KF-16, KF-25, KF-40, and KF-50. Installation instructions for this Flange End Replacement Kit are found in the Delta-P User’s Manual downloadable here.

Condition: New



Part Number: P1010194



Price: ₺3,147.68



Currency: Turkish Lira (TRY)

Flange End Replacement Kit for Ideal Delta-P System Isolation Protection Valve, NW KF-40 Flange
In Stock
5


Flange End for Ideal Delta-P System Isolation Protection Valve, NW KF-40 Flange Fits all Ideal Vacuum Delta-P Valves, KF-40 This is a KF-40 Flange End Replacement Kit for the Delta-P™ System Isolation Valve. This kit includes a new Viton® O-ring and 6 stainless steel, hex socket, flat head screws. This flange end, machined out of solid 6061-T6 aluminum, fits either side of the Delta-P Valve. Use it to replace a damaged one, to match ports on a mechanical pump with a different flange size, or to eliminate a flange adapter when connecting the Delta-P inlet flange to your vacuum system line. We offer Delta-P Valve Flange End Replacement Kits in five (5) sizes: KF-10, KF-16, KF-25, KF-40, and KF-50. Installation instructions for this Flange End Replacement Kit are found in the Delta-P User’s Manual downloadable here.

Condition: New



Part Number: P1010195



Price: ₺3,147.68



Currency: Turkish Lira (TRY)

Flange End Replacement Kit for Ideal Delta-P System Isolation Protection Valve, NW KF-50 Flange
In Stock
5


Flange End Replacement Kit for Ideal Delta-P System Isolation Protection Valve, NW KF-50 Flange Fits all Ideal Vacuum Delta-P Valves, KF-50 This is a KF-50 Flange End Replacement Kit for the Delta-P™ System Isolation Valve. This kit includes a new Viton® O-ring and 6 stainless steel, hex socket head cap screws. This flange end, machined out of solid 6061-T6 aluminum, fits either side of the Delta-P Valve. Use it to replace a damaged one, to match ports on a mechanical pump with a different flange size, or to eliminate a flange adapter when connecting the Delta-P inlet flange to your vacuum system line. We offer Delta-P Valve Flange End Replacement Kits in five (5) sizes: KF-10, KF-16, KF-25, KF-40, and KF-50. Installation instructions for this Flange End Replacement Kit are found in the Delta-P User’s Manual downloadable here.

Condition: New



Part Number: P1010196



Price: ₺3,393.87



Currency: Turkish Lira (TRY)
Marca de agua con el logotipo de Ideal Vacuum
CONTACT US
Ideal Vacuum Products , LLC
5910 Midway Park Blvd NE
Albuquerque, New Mexico 87109-5805 USA

Phone: (505) 872-0037
Fax: (505) 872-9001
info@idealvac.com